Wyniki wyszukiwania dla: atom probe tomography
-
Silica In Silico: A Molecular Dynamics Characterization of the Early Stages of Protein Embedding for Atom Probe Tomography
PublikacjaA novel procedure for the application of atom probe tomography (APT) to the structural analysis of biological systems, has been recently proposed, whereby the specimen is embedded by a silica matrix and ablated by a pulsed laser source. Such a technique, requires that the silica primer be properly inert and bio-compatible, keeping the native structural features of the system at hand, while condensing into an amorphous, glass-like...
-
Toward Mechanosynthesis of Diamondoid Structures: IX Commercial Capped CNT Scanning Probe Microscopy Tip as Nowadays Available Tool for Silylene Molecule and Silicon Atom Transfer
PublikacjaAccording to K. E. Drexler, advanced mechanosynthesis will employ advanced nanomachines, but advanced nanomachines will themselves be product of advanced mechanosynthesis. This circular relationship must be broken in SPM technology development. In the article, the possibility of use easy available commercial CNT tips to assembly silicon-based intermediate generations of nano-devices is considered. Mechanosynthesis of a target class...
-
Application of the 2-deoxyglucose scaffold as a new chiral probe for elucidation of the absolute configuration of secondary alcohols
PublikacjaHerein, we present the application of 2-deoxy-D-glucose derivatives as chiral probes for elucidation of the absolute configuration of chiral secondary alcohols. The probes are attached to the studied molecules via glycosylation reaction and the resulting products are examined by a set of standard 2D NMR experiments. The absolute configuration of an oxymethine carbon atom binding the probe is established on a basis of a set of diagnostic...
-
Special techniques and future perspectives: Simultaneous macro- and micro-electrode recordings
PublikacjaThere are many approaches to studying the inner workings of the brain and its highly interconnected circuits. One can look at the global activity in different brain structures using non-invasive technologies like positron emission tomography (PET) or functional magnetic resonance imaging (fMRI), which measure physiological changes, e.g. in the glucose uptake or blood flow. These can be very effectively used to localize active patches...
-
New method to monitor changes in the subarachnoid width and pial artery pulsation for physiological and clinical research
PublikacjaThere are several medical conditions associated with brain oedema such as traumatic brain injury, intoxication or tumors. Brain edema and related brain parenchyma expansion may lead to compression and subsequent injury of several brain structures. So far, the only method enabling detection and monitoring of the progress a cerebral oedema in a patient, has been monitoring of intracranial pressure (ICP) with a pressure probe inserted...
-
Molecular dynamics simulations reveal the balance of forces governing the formation of a guanine tetrad—a common structural unit of G-quadruplex DNA
PublikacjaG-quadruplexes (G4) are nucleic acid conformations of guanine-rich sequences, in which guanines are arranged in the square-planar G-tetrads, stacked on one another. G4 motifs form in vivo and are implicated in regulation of such processes as gene expression and chromosome maintenance. The structure and stability of various G4 topologies were determined experimentally; however, the driving forces for their formation are not fully...
-
Jednoelektronowy atom Diraca w słabym polu magnetycznym
PublikacjaW rozprawie przedstawiono opis wpływu zewnętrznego stałego, słabego, jednorodnego pola magnetycznego na jednoelektronowy atom Diraca. Wykorzystując funkcje gęstości ładunku elektrycznego oraz gęstości prądu elektrycznego, rozważono procesy indukowania się w atomie dodatkowych elektromagnetycznych momentów multipolowych. Dokonano analizy indukowanego momentu dipolowego, w wyniku której uzyskano wyrażenie dla magnetyzowalności atomu....
-
Tomography
Czasopisma -
ATOM INDONESIA
Czasopisma -
Optical properties of polyazomethine with oxygen atom in the backbon
PublikacjaPurpose: The aim of this paper is to show results of optical measurement performed on poly –(1-(4-methylenephenoxy-1)phenylene-4-methylene-1.4-phenylnenitrylomethylene) (PPI2) polyazomethine thinfilms and to compare with poly - (1.4-phenylenemethylenenitrilo-1.4 phenylenenitrilomethylene) (PPI).Design/methodology/approach: Influence of oxygen atom in the polymer chain on optical properties ofpolyazomethine was investigated....
-
3D Acoustic Field Intensity Probe Design and Measurements
PublikacjaThe aim of this paper is two-fold. First, some basic notions on acoustic field intensity and its measurement are shortly recalled. Then, the equipment and the measurement procedure used in the sound intensity in the performed research study are described. The second goal is to present details of the design of the engineered 3D intensity probe, as well as the algorithms developed and applied for that purpose. Results of the intensity...
-
Application of dynamic impedance spectroscopy to scanning probe microscopy.
PublikacjaDynamic impedance spectroscopy, designed for measuring nonstationary systems, was used in combination with scanning probe microscopy. Using this approach, impedance mapping could be carried-out simultaneously with topography scanning. Therefore, correlation of electrical properties with particular phases of an examined sample was possible. The sample used in this study was spheroidal graphite cast iron with clearly defined phases...
-
Development of the sound field 3D intensity probe based on miniature microphones
PublikacjaThe engineered measuring probe uses three pairs of miniature microphones coupled. The signals from the microphones after an initial amplification are fed to differential circuits. Due to the required symmetry of the circuit it was necessary to select electronic components very carefully. Moreover, additional digital signal processing techniques were applied to avoid amplitude and phase mismatch. The view of the engineered probe...
-
Assessing Highway Travel Time Reliability using Probe Vehicle Data
PublikacjaProbe vehicle data (also known as “floating car data”) can be used to analyze travel time reliability of an existing road corridor in order to determine where, when, and how often traffic congestion occurs at particular road segments. The aim of the study is to find the best reliability performance measures for assessing congestion frequency and severity based on probe data. Pilot surveys conducted on A2 motorway in Poland confirm...
-
Studying of polyoxadiazole with Si atom in the backbone
PublikacjaPurpose: The aim of this paper is to show properties of spin-coated thin films of new polymer having siliconatom in the backbone. This amorphous polymer has appeared to be applied as active films in organic devices (asOLED).Design/methodology/approach: Thin films of 4-(diphenyl(4-(4-(5-(p-tolyoxy)phenyl)-1,3,4-oxadiazol-2-yl)phenyloamino)methyl)-phenyl)silyl)-1-methylbenzamide (Oxad–Si-B) were obtained by spin-coating method.The...
-
Dual-Energy Computed Tomography in Loosening of Revision Hip Prosthesis
Publikacja -
Jednoelektronowy atom Diraca w słabym polu elektrycznym
PublikacjaW pracy przeanalizowano wpływ słabego, stałego, jednorodnego, zewnętrznego pola elektrycznego na relatywistyczny atom jednoelektronowy, znajdujący się w stanie podstawowym. Wykorzystując rozwinięcie uogólnionej funkcji Greena w bazie funkcji Sturma-Diraca-Coulomba, wyznaczono trzy rodzaje elektromagnetycznych momentów dipolowych (elektryczny, magnetyczny oraz magnetyczny toroidalny), indukowanych w atomie przez zewnętrzne pole...
-
1D portable optical coherence tomography system
Publikacja—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Relativistic two-dimensional hydrogen-like atom in a weak magnetic field
PublikacjaA two-dimensional (2D) hydrogen-like atom with a relativistic Dirac electron, placed in a weak, static, uniform magnetic field perpendicular to the atomic plane, is considered. Closed forms of the first- and second-order Zeeman corrections to energy levels are calculated analytically, within the framework of the Rayleigh–Schrödinger perturbation theory, for an arbitrary electronic bound state. The second-order calculations are...
-
Ultrasonic Tomography of Brick Columns Based on FEM Calculations
PublikacjaUltrasonic tomography is one of the most developed method of non-destructive testing. Despite being used mainly in medicine, it is becoming more and more popular as a method for monitoring of structural elements. It allows to examine the internal structure and technical condition of the tested element. This paper investigates the influence of crosssectional geometry on an obtained tomographic image. Wave propagation signals were...
-
Two-dimensional hydrogen-like atom in a weak magnetic field
PublikacjaWe consider a non-relativistic two-dimensional (2D) hydrogen-like atom in a weak, static, uniform magnetic field perpendicular to the atomic plane. Within the framework of the Rayleigh-Schr¨odinger perturbation theory, using the Sturmian expansion of the generalized radial Coulomb Green function, we derive explicit analytical expressions for corrections to an arbitrary planar hydrogenic bound-state energy level, up to the fourth...
-
Internal imaging of concrete fracture based on elastic waves and ultrasound computed tomography
PublikacjaThe condition assessment of concrete structures belongs to the greatest challenges of non-destructive testing. Monitoring the fracture process of concrete and detecting cracks at the earliest possible stage is a vital aspect to ensure the safety of civil engineering objects. The use of ultrasound tomography enables imaging the internal structure of a tested element. This study aims at the visualization of fracture damage in concrete...
-
Scanning Probe Microscopy in Electrochemistry and Materials Science
Kursy OnlineProwadzący: Prof. Jacek LIPKOWSKI z University of Guelph, Ontario, Canada. Kurs zorganizowany dla doktorantów Wydziału Chemicznego Politechniki Gdańskiej. Dostęp do kursu po kontakcie z administratorem.
-
Atom-economic thiophosphoroselenenylations of C–H acid esters and amides
PublikacjaThree improved thiophosphoroselenenylation procedures of CHacids, including derivatives of malonic and acetyl-, phosphono-, 4-nitrophenyl- and 3-pyridylacetic acids, have been described and compared to previously reported thiophosphoroselenylation of diethyl malonate using bis(disopropoxyphosphinothioyl)diselenide alone or with the aid of methyl iodide. The use of iodine makes it possible to utilize both equivalents of the selenenylating...
-
Application of the X-ray micro computed tomography to the analysis of the structure of polymeric materials
PublikacjaIn this paper the application of X-ray micro-computed tomography (micro-CT) as a non-destructive testing method of polymeric materials is presented. Increasing applicability of polymers in variedend-use industries such as automotive, building and construction, consumer goods, and packaging is propelling the growth of the global polymer processing market. However, controlling of the polymer structure is one of the most important...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublikacjaThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Probe signal processing for channel estimation in underwater acoustic communication system
PublikacjaUnderwater acoustic communication channels are characterized by a large variety of propagation conditions. Designing a reliable communication system requires knowledge of the transmission parameters of the channel, namely multipath delay spread, Doppler spread, coherence time, and coherence bandwidth. However, the possibilities of its estimation in a realtime underwater communication system are limited, mainly due to the computational...
-
INVESTIGATIONS OF THE LABORATORY FARYMANN DIESEL ENGINE D10 TYPE BY MEANS OF A LANGMUIR PROBE
PublikacjaA precise determination of the crankshaft angular position, at which fuel ignition occurs in the SI engine, enables credible diagnosis of the technical state of its working space as well as of the fuel feed system. An observation of the Langmuir probe signal provides entirely new possibilities for engine diagnostics. The probe is introduced into the working space of a cylinder through its indicator valve. This paper presents the...
-
Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation
PublikacjaIn brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublikacjaThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Quantitative Active Dynamic Thermal IR-Imaging and Thermal Tomography in Medical Diagnostic
PublikacjaPrinciples of Active dynamic thermal (ADT) IR-imaging and Thermal Tomography are described in details. Basic medical applications of this new modality are also discussed.
-
Photoluminescence as a probe of phosphorene properties
PublikacjaHere, we provide a detailed evaluation of photoluminescence (PL) as a comprehensive tool for phosphorene characterization with the emphasis on a prominent quantitative role of PL in providing fingerprint-like features due to its extreme sensitivity to the band structure details, anisotropy, disorder, external fields, etc. Factors such as number of layers, dimensionality, structural and chemical disorder, and environmental factors...
-
Photoluminescence as a probe of phosphorene properties
Publikacja -
Colvolutional calibration of AFM probe
Dane BadawczeAtomic force microscopy is based on the interaction of the examined surface with a probe of a pyramidal shape, tipped with a sharp end with a radius of curvature ranging from single nanometers to hundreds of nanometers. The resolution of the obtained image is of course dependent on the above-mentioned geometric size, and the resulting image is a convolutional...
-
Efficient signal processing in spectroscopic optical coherence tomography
PublikacjaSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Detection of petroleum products using optical coherence tomography
PublikacjaIn this work, we present a novel method developed for the analysis of the properties of thin layers for detecting petroleum products on a water surface using a commercially available optical coherence tomography (OCT) system. The spectral density analysis of the signal from a spectroscopic OCT (S-OCT) enables us to perform the precision calculation of the thin layer thickness and other properties like homogeneity, and dispersion,...
-
Nanoparticles displacement analysis using optical coherence tomography
PublikacjaOptical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits...
-
Non-Destructive Assessment of Masonry Pillars using Ultrasonic Tomography
PublikacjaIn this paper, a condition assessment of masonry pillars is presented. Non-destructive tests were performed on an intact pillar as well as three pillars with internal inclusions in the form of a hole, a steel bar grouted by gypsum mortar, and a steel bar grouted by cement mortar. The inspection utilized ultrasonic stress waves and the reconstruction of the velocity distribution was performed by means of computed tomography. The...
-
Magnetically sensitive fiber probe with nitrogen-vacancy center nanodiamonds integrated in a suspended core
PublikacjaEfficient collection of photoluminescence arising from spin dynamics of nitrogen vacancy (NV) centers in diamond is important for practical applications involving precise magnetic field or temperature mapping. These goals may be realized by the integration of nanodiamond particles with optical fibers and volumetric doping of the particles alongside the fiber core. That approach combines the advantages of robust axial fixation of...
-
Second-order Stark effect and polarizability of a relativistic two-dimensional hydrogenlike atom in the ground state
PublikacjaThe second-order Stark effect for a planar Dirac one-electron atom in the ground state is analyzed within the framework of the Rayleigh-Schrödinger perturbation theory, with the use of the Sturmian series expansion of the generalized Dirac-Coulomb Green's function. A closed-form analytical expression for the static dipole polarizability of that system is found. The formula involves the generalized hypergeometric function ${}_{3}F_{2}$...
-
Study of probe signal bandwidth influence on estimation of coherence bandwidth for underwater acoustic communication channel
PublikacjaA signal transmitted in a shallow Underwater Acoustic Communication (UAC) channel suffers from time dispersion due to the multipath propagation and the refraction phenomena. This causes intersymbol interference of the received signal and frequency-selective fading observed in its spectrum. Coherence bandwidth is one of the key transmission parameters used for designing the physical layer of a data transmission system to minimise...
-
An Analysis of Probe-Fed Rectangular Patch Antennas With Multilayer and Multipatch Configurations on Cylindrical Surfaces
PublikacjaA multi-patch configuration of probe-fed rectangular microstrip antennas mounted on a cylindrical body, with electrically small radius, with an arbitrary number of substrate and superstrate layers is investigated in this paper. A full-wave analysis and a moment-method calculation are employed. A unified procedure for creating proper matrices for the investigated geometry of the structure is outlined here. Numerical results for...
-
Parallel multithread computing for spectroscopic analysis in optical coherence tomography
PublikacjaSpectroscopic Optical Coherence Tomography (SOCT) is an extension of Optical Coherence Tomography (OCT). It allows gathering spectroscopic information from individual scattering points inside the sample. It is based on time-frequency analysis of interferometric signals. Such analysis requires calculating hundreds of Fourier transforms while performing a single A-scan. Additionally, further processing of acquired spectroscopic information...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublikacjaCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublikacjaThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Adaptive Hounsfield Scale Windowing in Computed Tomography Liver Segmentation
PublikacjaIn computed tomography (CT) imaging, the Hounsfield Unit (HU) scale quantifies radiodensity, but its nonlinear nature across organs and lesions complicates machine learning analysis. This paper introduces an automated method for adaptive HU scale windowing in deep learning-based CT liver segmentation. We propose a new neural network layer that optimizes HU scale window parameters during training. Experiments on the Liver Tumor...
-
Central-force decomposition of spline-based modified embedded atom method potential
PublikacjaCentral-force decompositions are fundamental to the calculation of stress fields in atomic systems by means of Hardy stress. We derive expressions for a central-force decomposition of the spline-based modified embedded atom method (s-MEAM) potential. The expressions are subsequently simplified to a form that can be readily used in molecular-dynamics simulations, enabling the calculation of the spatial distribution of stress in...
-
Integration and verification of meteorological observations and NWP model data for the local GNSS tomography
PublikacjaGNSS meteorology applies the Global Navigation Satellite Systems (GNSS) to derive information about the state of the atmosphere (particularly troposphere). The tomography is one of the methods used in GNSS meteorology. The input data of GNSS tomography are the signal troposphere delays, results of GNSS data processing and additionally meteorological observations and Numerical Weather Prediction (NWP) models data. Different types...
-
Electrical and mechanical characterization of two-phase alloys by means of scanning probe microscopy in dynamic impedance spectroscopy mode
PublikacjaDynamic impedance spectroscopy, evaluated for measuring non-stationary systems, was used in combination with scanning probe microscope. Using this approach, localized impedance measurements in the AFM contact mode could be carried out. Additionally, impedance–force curves were made at each phase of investigated materials to illustrate the relation between impedance and the force applied to a probe. Therefore, correlation of electrical...
-
Imaging of Increasing Damage in Steel Plates Using Lamb Waves and Ultrasound Computed Tomography
PublikacjaThis paper concerns inspection of steel plates, with particular emphasis on the assessment of in-creasing damage. Non-destructive tests were performed on four plates, one of which was un-damaged, while the remaining three had a defects in the form of circular holes with a diameter of 2, 5, and 10 cm. Guided Lamb waves were used in the research, and the image reconstruction was performed using ultrasound computed tomography. The...