Real-time working gas recognition system based on the array of semiconductor gas sensors and portable computer Raspberry PI
PublikacjaThe gas-analyzing systems based on the array of partially selective gas sensors and pattern-recognition techniques are potentially fast and low-cost alternative for other devices, like gas analysers. They give the possibility of recognition the type and the concentration of measured volatile compounds in their working environment. In this work we present the implementation of gas recognition system, in which the signals from an...
-
Gas mixtures recognition using an array of amperometric gas sensors with drifting or faulty sensors
PublikacjaIn this study, the possibility of using selected methods for diagnostics of performance of matrix composed with six amperometric electrochemical gas sensors is investigated. Measurements of sensor responses in selected concentrations of single toxic gases or gas mixtures were performed and were repeated over time to show sensor drift. Additionally, the studies on the sensors’ drift were performed. The drift has been recognized...
-
An electronic nose for quantitative determination of gas concentrations
PublikacjaThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequen tly, there is considerable need for an instrument that can be a substitution of the human sense of smell. Electronic nose devices from the mid 1980s are used in growing number of applications. They comprise an array of several electrochemical gas sensors...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublikacjaMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Features extraction from the electrocatalytic gas sensor responses
PublikacjaOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Voice command recognition using hybrid genetic algorithm
PublikacjaAbstract: Speech recognition is a process of converting the acoustic signal into a set of words, whereas voice command recognition consists in the correct identification of voice commands, usually single words. Voice command recognition systems are widely used in the military, control systems, electronic devices, such as cellular phones, or by people with disabilities (e.g., for controlling a wheelchair or operating a computer...
-
Pracujący w czasie rzeczywistym system detekcji gazów wykorzystujący przenośny komputer Raspberry PI oraz matrycę półprzewodnikowych czujników gazu
PublikacjaThe gas-analyzing systems based on the array of partially selective gas sensors and pattern-recognition techniques are potentially fast and lowcost alternative for other devices, like gas‑analysers. They give the possibility of recognition the type and the concentration of measured volatile compounds in their working environment. In this work we present the implementation of gas recognition system, in which the signals from an...
-
An electronic nose based on the semiconducting and electrochemical gas sensors
PublikacjaThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequently, there is a significant need for an instrument that can be a substitution of the human sense of smell. Development of an electronic nose devices is an active area of research starting from pioneering research of Dodd and Persuad in the mid-1980s. Such systems...
-
Determination of toxic gases based on the responses of a single electrocatalytic sensor and pattern recognition techniques
PublikacjaA response from an electrocatalytic gas sensor contains fingerprint information about the type of gas and its concentration. As a result, a single gas sensor can be used for the determination of different gases. However, information about the type of gas and its concentration is hidden in the unique shape of the current–voltage response and it is quite difficult to explore. One of the ways to get precise information about the measured...
-
Extraction and evaluation of gas-flow-dependent features from dynamic measurements of gas sensors array
PublikacjaGas analyzers based on gas sensors are the devices which enable recognition of various kinds of volatile compounds. They have continuously been developed and investigated for over three decades, however there are still limitations which slow down the implementation of those devices in many applications. For example, the main drawbacks are the lack of selectivity, sensitivity...
-
Piotr Jasiński prof. dr hab. inż.
OsobyPiotr Jasinski obtained MSc in electronics in 1992 from the Gdansk University of Technology (GUT), Poland. Working at GUT, he received PhD in 2000 and DSc in 2009. Between 2001 and 2004 Post Doctoral Fellow at Missouri University of Science and Technology, while between 2008 and 2010 an Assistant Research Professor. Currently is an Associate Professor at Gdansk University of Technology working in the field of electronics, biomedical...
-
A calibration model for gas sensor array in varying environmental conditions
PublikacjaAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A calibration model for gas sensor array in varying environmental conditions
PublikacjaAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublikacjaElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Techniques of acquiring additional features of the responses of individual gas sensors
PublikacjaGas sensors usually exhibit lack of selectivity, require fre quent calibration, exhibit drift of the response and a lot of factors, such as humidity or ambient temperature, influen ce their performance. Different approaches can be used to overcome this shortcomings. Building arrays of different sensors and usage of pattern recognition methods to analyze responses of elements...
-
Application of gamma densitometry and statistical signal analysis to gas phase velocity measurements in pipeline hydrotransport
PublikacjaThe work presents selected methods of signal analysis used in the processing of data obtained from radiometric probes. The used data came from an exemplary study of a two-phase liquid-gas flow at the laboratory installation. In such rigs many possible transport types may be observed, i.e. slug, plug and bubble flow, and each of them gives different signal-to-noise ratio of recorded data. Therefore, available radiometric methods...
-
Application of gamma densitometry and statistical signal analysis to gas phase velocity measurements in pipeline hydrotransport
PublikacjaThe work presents selected methods of signal analysis used in the processing of data obtained from radiometric probes. The used data came from an exemplary study of a two-phase liquid-gas flow at the laboratory installation. In such rigs many possible transport types may be observed, i.e. slug, plug and bubble flow, and each of them gives different signal-to-noise ratio of recorded data. Therefore, available radiometric methods...
-
Application of fuzzy logic to determine the odour intensity of model gas mixtures using electronic nose
PublikacjaThe paper presents the possibility of application of fuzzy logic to determine the odour intensity of model, ternary gas mixtures (α-pinene, toluene and triethylamine) using electronic nose prototype. The results obtained using fuzzy logic algorithms were compared with the values obtained using multiple linear regression (MLR) model and sensory analysis. As the results of the studies, it was found the electronic nose prototype along...
-
Zastosowanie metod eksploracji danych do analizy odpowiedzi czujników gazu
PublikacjaZagadnienia poruszane w niniejszej rozprawie dotyczą zastosowania metod eksploracji danych do analizy odpowiedzi czujników gazu, umożliwiających poprawną identyfikację składu mieszaniny gazowej w elektronicznych systemach rozpoznawania gazu. Elektroniczne systemy rozpoznawania gazu to urządzenia wykorzystujące czujniki gazu oraz odpowiednio dobrane metody analizy danych pomiarowych, zdolne do określenia składu mierzonej mieszaniny...
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublikacjaMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...
-
“Shadow” vs. “Phase 3D” method within endoscopic examinations of marine engines
PublikacjaA visual investigation of surfaces creating internal, working spaces of marine combustion engines by means of specialized view-finders so called endoscopes is at present almost a basic method of technical diag-nostics. The surface structure of constructional material is visible during investigations like through the magnifying glass (usually with a precisely determined magnification), which makes possible a detection, recognition...
-
Molecularly imprinted polymers for the detection of volatile biomarkers
PublikacjaIn the field of cancer detection, the development of affordable, quick, and user-friendly sensors capable of detecting various cancer biomarkers, including those for lung cancer (LC), holds utmost significance. Sensors are expected to play a crucial role in the early-stage diagnosis of various diseases. Among the range of options, sensors emerge as particularly appealing for the diagnosis of various diseases, owing to their cost-effectiveness,...
-
Determination of long-chain aldehydes using a novel quartz crystal microbalance sensor based on a biomimetic peptide
PublikacjaThere is an increasingly popular trend aimed at improvement of fundamental metrological parameters of sensors via implementation of materials mimicking biological olfactory systems. This study presents investigation on usefulness of the peptide mimicking HarmOBP7 region as a receptor element of the piezoelectric sensor for selective analysis of long-chain aldehydes. Identification of odorant binding proteins creates new possibilities...
-
Blood concentrations of a new psychoactive substance 4-chloromethcathinone (4-CMC) determined in 15 forensic cases
PublikacjaPurpose: The 4-chloromethcathinone (4-CMC) is a synthetic derivative of cathinone and belongs to new psychoactive substances. Neither data on the effects of 4-CMC on the human body, nor on nontoxic, toxic and lethal concentrations in biological materials have been published in the literature. This paper describes the results of an analysis of the blood concentrations of 4-CMC determined in 15 forensic cases related to nonfatal...
-
Conditions for increasing the recognition of degradation in thermal-flow diagnostics, taking into account environmental legal aspects
PublikacjaThe ever-increasing demand for electricity and the need for conventional sources to cooperate with renewable ones generates the need to increase the efficiency and safety of the generation sources. Therefore, it is necessary to find a way to operate existing facilities more efficiently with full detection of emerging faults. These are the requirements of Polish, European and International law, which demands that energy facilities...
-
Ethylene photocatalytic decomposition in high temperature reaction chamber
Dane BadawczeData contain data logs of measurements performed on High Temperature Chamber "The Praying Mantis" coupled with SRI 8010 gas chromatograph. Measurement was performed for TiO2 irradiated by UV and under flowing of ethylene gas diluted in air and with the use of elevated temperature.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-Al2O3
Dane BadawczeThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 25-75wt.% NiO-Al2O3
Dane BadawczeThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 25/75 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
Tensile test of 1.4307 / X2CrNi18-9 / AISI 304L grade austenitic steel
Dane BadawczeShip structures and their components are build mainly of steel. Hull steel is used to build the hull structure. Some structural elements, such as RSW (Refrigerated See Water) tanks, or LNG (Liquid Natural Gas) tanks - gas transported at temperatures below -162° C, are build from austenitic steels. Austenitic steels have a different microstructure and...
-
Tensile test of 1.4541 / X6CrNi18-10 / AISI 321 grade austenitic steel
Dane BadawczeShip structures and their components are build mainly of steel. Hull steel is used to build the hull structure. Some structural elements, such as RSW (Refrigerated See Water) tanks, or LNG (Liquid Natural Gas) tanks - gas transported at temperatures below -162° C, are build from austenitic steels. Austenitic steels have a different microstructure and...
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-GDC
Dane BadawczeThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-GDC (Gadolinia Doped Ceria 20mol.%Gd2O3) catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
Tensile test of 1.4571 / X6CrNiMoTi17-12-2 / AISI 316Ti grade austenitic steel
Dane BadawczeShip structures and their components are build mainly of steel. Hull steel is used to build the hull structure. Some structural elements, such as RSW (Refrigerated See Water) tanks, or LNG (Liquid Natural Gas) tanks - gas transported at temperatures below -162° C, are build from austenitic steels. Austenitic steels have a different microstructure and...
-
Methane (CH4) calibration set of FTIR spectra
Dane BadawczeThe calibration spectra for CH4 concentration calibration were supplied with this dataset
-
Carbon (II) oxide (CO) calibration set of FTIR spectra
Dane BadawczeThe calibration spectra for CO concentration calibration were supplied with this dataset
-
Carbon dioxide (CO2) calibration set of FTIR spectra
Dane BadawczeThe calibration spectra for CO2 concentration calibration were supplied with this dataset
-
Electrical and noise responses of carbon nanotube networks enhanced by UV light for nitrogen dioxide sensing
Dane BadawczeNetworks consisting of randomly oriented carbon nanotubes (CNN) were investigated toward nitrogen dioxide detection by means of electrical and low-frequency noise measurements. UV-activation of CNN layers improved gas sensitivity and reduced the limit of detection, especially by employing 275 nm-LED. This data set includes DC resistance measurements...
-
Kinetics of hexane and cyclohexane biodegradation using Candida subhashii in mineral salt medium in the presence of DES solution
Dane BadawczeDataset presents results of investigations on kinetics of biodegradation of hexane and cyclohexane in Candida subhashii.
-
Emotion Recognition from Physiological Channels Using Graph Neural Network
PublikacjaIn recent years, a number of new research papers have emerged on the application of neural networks in affective computing. One of the newest trends observed is the utilization of graph neural networks (GNNs) to recognize emotions. The study presented in the paper follows this trend. Within the work, GraphSleepNet (a GNN for classifying the stages of sleep) was adjusted for emotion recognition and validated for this purpose. The...
-
Limitations of Emotion Recognition from Facial Expressions in e-Learning Context
PublikacjaThe paper concerns technology of automatic emotion recognition applied in e-learning environment. During a study of e-learning process the authors applied facial expressions observation via multiple video cameras. Preliminary analysis of the facial expressions using automatic emotion recognition tools revealed several unexpected results, including unavailability of recognition due to face coverage and significant inconsistency...
-
Mining inconsistent emotion recognition results with the multidimensional model
PublikacjaThe paper deals with the challenge of inconsistency in multichannel emotion recognition. The focus of the paper is to explore factors that might influence the inconsistency. The paper reports an experiment that used multi-camera facial expression analysis with multiple recognition systems. The data were analyzed using a multidimensional approach and data mining techniques. The study allowed us to explore camera location, occlusions...
-
Limitations of Emotion Recognition in Software User Experience Evaluation Context
PublikacjaThis paper concerns how an affective-behavioural- cognitive approach applies to the evaluation of the software user experience. Although it may seem that affect recognition solutions are accurate in determining the user experience, there are several challenges in practice. This paper aims to explore the limitations of the automatic affect recognition applied in the usability context as well as...
-
Accelerometer signal pre-processing influence on human activity recognition
PublikacjaA study of data pre-processing influence on accelerometer-based human activity recognition algorithms is presented. The frequency band used to filter-out the accelerometer signals and the number of accelerometers involved were considered in terms of their influence on the recognition accuracy.
-
Emotion Recognition for Affect Aware Video Games
PublikacjaIn this paper the idea of affect aware video games is presented. A brief review of automatic multimodal affect recognition of facial expressions and emotions is given. The first result of emotions recognition using depth data as well as prototype affect aware video game are presented
-
The electrical conductivity of pristine, La-, and Nb-doped SFM measured in air and hydrogen atmospheres
Dane BadawczeThis dataset consists of an Excel sheet with the result of DC4W method of electrical measurements. The measurements were conducted on pristine strontium ferrite molubdate as well as ones doped with La and Nb. Additionally two samples co-doped with La and Ni/Co were analyzed. Pellets were prepared by high temperature sintering at 1400 deg. C, then cut...
-
Language Models in Speech Recognition
PublikacjaThis chapter describes language models used in speech recognition, It starts by indicating the role and the place of language models in speech recognition. Mesures used to compare language models follow. An overview of n-gram, syntactic, semantic, and neural models is given. It is accompanied by a list of popular software.
-
Material for Automatic Phonetic Transcription of Speech Recorded in Various Conditions
PublikacjaAutomatic speech recognition (ASR) is under constant development, especially in cases when speech is casually produced or it is acquired in various environment conditions, or in the presence of background noise. Phonetic transcription is an important step in the process of full speech recognition and is discussed in the presented work as the main focus in this process. ASR is widely implemented in mobile devices technology, but...
-
Interactions with recognized patients using smart glasses
PublikacjaRecently, different smart glasses solutions have been proposed on the market. The rapid development of this wearable technology has led to several research projects related to applications of smart glasses in healthcare. In this paper we propose a general architecture of the system enabling data integration for the recognized person. In the proposed system smart glasses integrates data obtained for the recognized patient from health...
-
Electrical responses of Graphene-Silicon Schottky diodes toward nitrogen dioxide and tetrahydrofuran under irradiation
Dane BadawczeGraphene-Silicon Schottky junctions were utilized as gas sensors toward inorganic (nitrogen dioxide) and organic (tetrahydrofuran) gas qualitative and quantitative detection. The electrical responses of the sensors were collected in the form of current-voltage characteristics and measurements of current in time domain for a selected voltage bias. The...
-
Investigation of educational processes with affective computing methods
PublikacjaThis paper concerns the monitoring of educational processes with the use of new technologies for the recognition of human emotions. This paper summarizes results from three experiments, aimed at the validation of applying emotion recognition to e-learning. An analysis of the experiments’ executions provides an evaluation of the emotion elicitation methods used to monitor learners. The comparison of affect recognition algorithms...
-
Vocalic Segments Classification Assisted by Mouth Motion Capture
PublikacjaVisual features convey important information for automatic speech recognition (ASR), especially in noisy environment. The purpose of this study is to evaluate to what extent visual data (i.e. lip reading) can enhance recognition accuracy in the multi-modal approach. For that purpose motion capture markers were placed on speakers' faces to obtain lips tracking data during speaking. Different parameterizations strategies were tested...