Filters
total: 1963
filtered: 1675
-
Catalog
- Publications 1675 available results
- Journals 17 available results
- Conferences 1 available results
- People 43 available results
- Projects 11 available results
- Laboratories 1 available results
- Research Teams 1 available results
- Research Equipment 1 available results
- e-Learning Courses 80 available results
- Events 3 available results
- Open Research Data 130 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: MONITORING RZEKI BUG
-
Testing and sampling devices for monitoring volatile and semi-volatile organic compounds in indoor air
PublicationAdults spend most of their time in enclosed spaces (e.g., apartment, office and public buildings). According to research conducted by scientists, air quality indoors is much worse than the ambient air quality outdoors. Hazardous chemicals found in air indoors can adversely affect the functioning of the human body and cause many respiratory and circulatory diseases. Harmful chemical compounds (mainly volatile organic compounds and...
-
Investigation of Noise-Induced Instabilities in Quantitative BiologicalSpectroscopy and Its Implications for Noninvasive Glucose Monitoring
PublicationPrzedstawiono sposób oceny błędów jakie pojawiają się przy estymacji poziomu glukozy we krwi za pomocą pomiarów widm Ramana. Zastosowano nieliniowy algorytm regresji według maszyny wektorów nośnych. Określono jak na wyznaczenie stężenia glukozy we krwi wpływają błędy pomiarów widmach Ramana oraz błędów pomiaru referencyjnego stężenia glukozy podczas etapu kalibracji modelu (etapu uczenia algorytmu maszyny wektorów nośnych). Określono...
-
Networked Object Monitor - A distributed system for monitoring, diagnostics and control of complex industrial facilities
PublicationRozwój mobilności i technologii internetowych, a także globalizacji gospodarki światowej, uwzględniający kluczowe aspekty zarządzania przepływem informacji, otworzył zupełnie nowe możliwości opracowywania i konstruowania innowacyjnych rozwiązań technicznych. Z taką myślą powstał prototyp Sieciowego Monitora Obiektu, aplikacji umożliwiającej nie tylko ciągłą kontrolę parametrów obiektów przemysłowych i biznesowych, ale również zarządzanie...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublicationThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...
-
An application of neural network for Structural Health Monitoring of an adaptive wing with an array of FBG sensors
PublicationW pracy przedstwiono możliwości zastoswania sieci czujników FBG i sztucznych sieci neuronowych do detekcji uszkodzeń w poszyciu adaptacyjnego skrzydła.
-
Monitoring. Wybrane problemy związane z oceną stanu cięgien wielosplotowych w mostach
PublicationW referacie przedstawiono wyniki analiz prowadzonych przy opracowaniu architektury monitoringu mostu podwieszonego przez Wisłok w Rzeszowie. Dokonano tam klasyfikacji zmian, jakimi konstrukcja podlega w czasie i wykonano szereg obliczeń pozorujących uszkodzenia w linach podwieszenia. Wnioski opracowane w wyniku analizy mają charakter uniwersalny i mogą być wykorzystane przy opracowaniu systemu monitoringu mostów, w których zastosowano...
-
Novel condition monitoring of induction motor bearings via motor current signature analysis
PublicationThe paper authors are researching the assessment of bearing conditions in induction motors. The methods developed by the authors are based on measurements and analysis of the motor supply current, which is particularly attractive in the absence of access to the engine. The article provides an overview of selected methods of induction motor bearings diagnostic based on Motor Current Signature Analysis (MCSA). However, there is no...
-
Monitoring działania wzmocnienia gruntu pod nasypem drogowym za pomocą sztywnych kolumn
PublicationOpis systemu pomiarowego zainstalowanego w kolumnach betonowych wzmacniających słabe podłoże gruntowe pod nasypem drogowym. Wstępne przedstawienie przykładowych wyników pomiarów. Problematyka niedokładności i odchyleń pomiarowych oraz sposób ich interpretacji.
-
Coda wave interferometry in monitoring the fracture process of concrete beams under bending test
PublicationEarly detection of damage is necessary for the safe and reliable use of civil engineering structures made of concrete. Recently, the identification of micro-cracks in concrete has become an area of growing interest, especially using wave-based techniques. In this paper, a non-destructive testing approach for the characterization of the fracture process was presented. Experimental tests were made on concrete beams subjected to mechanical...
-
Analysis of Modal Parameters Using a Statistical Approach for Condition Monitoring of the Wind Turbine Blade
PublicationThe primary objective of the presented paper is the numerical and experimental investigation related to developing a useful diagnostic method, which can be used for determining the site and size of damage in laminated shells of wind turbine blades. The described detection technique is based on the analysis of low frequencies bending vibrations mode shapes of rotor blades. The authors used the commonly applied statistics methods...
-
Green capsule phase microextraction employing hydrophobic monolithic sol-gel octadecyl siloxane platforms for the monitoring of organophosphorus pesticides in environmental water samples
PublicationIn this study, a novel, facile and green capsule phase microextraction (CPME) method is presented for the extraction and preconcentration of organophosphorus pesticides (i.e., chlorpyrifos, disulfoton, ethoprophos, fenchlorphos, prothiofos, and parathion-methyl) from environmental water samples. Monolithic sol-gel octadecyl siloxane (sol-gel C18) sorbent encapsulated within porous polypropylene capsules was synthesized, characterized,...
-
The European Union's Water Framework Directive - A new challenge in monitoring water quality. Ramowa Dyrektywa Wodna Unii Europejskiej - Nowe wyzwanie w monitoringu jakości wody
PublicationMonitoring jakości wody polega zwykle na punktowym pobieraniu próbek z użyciem odpowiednich próbników, po którym następuje etap analizy w celu określenia stężenia zanieczyszczeń. Pomimo wielu zalet, metoda ta ma ograniczenia w zakresie badania rozkładu czasowego i przestrzennego zanieczyszczeń oraz w zakresie oceny biodostępności zanieczyszczeń. Wdrożenie Ramowej Dyrektywy Wodnej (2000/60/EC)w krajach Unii Europejskiej będzie wymagało...
-
Passive sampling techniques in monitoring of BTEX in urban air = Technika dozymetrii pasywnej w monitoringu analitów z grupy BTEX w powietrzu atmosferycznym na obszarach miejskich
PublicationLotna związki organiczne, a wśród nich związki z grupy BTEX, odgrywają istotną rolę w chemii środowiska. Mogą one oddziaływać znacząco na abiotyczną jak i biotyczną część środowiska. Nie bez znaczenia jest również wpływ LZO na organizmy żywe w tym na zdrowie ludzkie. Ponadto posiadają one zdolność do kumulowania się w organizmach żywych zwiększając ryzyko zachorowań. Niektóre z nich mogą również niekorzystnie oddziaływać na organizmy...
-
Passive sampling techniques in monitoring of BTEX in urban air = Technika dozymetrii pasywnej w monitoringu analitów z grupy BTEX w powietrzu atmosferycznym na obszarach miejskich
PublicationLotna związki organiczne, a wśród nich związki z grupy BTEX, odgrywają istotną rolę w chemii środowiska. Mogą one oddziaływać znacząco na abiotyczną jak i biotyczną część środowiska. Nie bez znaczenia jest również wpływ LZO na organizmy żywe w tym na zdrowie ludzkie. Ponadto posiadają one zdolność do kumulowania się w organizmach żywych zwiększając ryzyko zachorowań. Niektóre z nich mogą również niekorzystnie oddziaływać na organizmy...
-
Evaluation of the use of reindeer droppings for monitoring essential and non-essential elements in the polar terrestrial environment
PublicationExcess or toxic metals, non-metals and metalloids can be eliminated from the organism by deposition in inert tissue (e.g. fur) or excretion with body secretions, urine and faeces. Droppings are one of the main routes for the elimination of multiple elements and they can be collected without direct contact with the animal. Contaminant concentration has been examined in non-lethally collected tissues of several species (especially...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
Publication -
The use of terrestrial laser scanning in monitoring and analyses of erosion phenomena in natural and anthropogenically transformed areas
Publication -
Condition monitoring and fault diagnosis of wind turbines based on structural break detection in SCADA data
Publication -
Process Monitoring in Heavy Duty Drilling Rigs—Data Acquisition System and Cycle Identification Algorithms
Publication -
Prediction of NOx Emission Based on Data of LHD On-Board Monitoring System in a Deep Underground Mine
Publication -
Intraoperative monitoring of cerebral NIRS oximetry leads to better postoperative cognitive performance: A pilot study
Publication -
Static renewal and continuous-flow calibration of two types of passive samplers for the monitoring of pharmaceuticals in wastewater
Publication -
Planowanie zintegrowane i monitoring rozwoju zrównoważonego obszarów lokalnych a ich zagospodarowanie dla turystyki
PublicationPrzez planowanie zintegrowane rozumie się planowanie kompleksowe, wieloaspektowe, łączące aspekty społeczno-gospodarcze i ekologiczne z aspektami przestrzennymi. Autorzy prezentują ideę rozwoju zrównoważonego, typy obszarów wiejskich i formy planowania w polskich gminach. Proponują zintegrowane planowanie rozwoju obszaru turystycznego. Formułują postulaty co do monitoringu rozwoju zrównoważonego obszarów lokalnych oraz sposobu...
-
Continuous Monitoring of Thermooxidative Degradation Products of Polystyrene by Membrane Extraction with Sorbent Interface and Gas Chromatography
Publication -
Privacy-Preserving, Scalable Blockchain-Based Solution for Monitoring Industrial Infrastructure in the Near Real-Time
Publication -
Assessment of respiratory responses to emotional virtual reality stimuli with non-contact respiration monitoring system
Publication -
Effect of housing geometry on the performance of Chemcatcher passive sampler for the monitoring of hydrophobic organic pollutants in water
PublicationZaprojektowano nową obudowę próbnika typu Chemcatcher, tzw. próbnik typu Chemcatcher drugiej generacji. Większość badań kalibracyjnych przeprowadzono stosując próbnik typu Chemcatcher pierwszej generacji. Dlatego zbadano wpływ obudowy próbnika typu Chemcatcher na jego działanie.
-
Optoelektroniczny monitoring stanu wzbudzenia plazmy niskotemperaturowej w procesach syntezy optycznych warstw diamentopodobnych
PublicationZrealizowana praca jest jednym z głównych zadań wieloletniego projektu badawczego z zakresu syntezy warstw diamentopodobnych. Celem bezpośrednim pracy było określenie rozkładu wzbudzenia plazmy w komorze technologicznej stanowiska PA ECR CVD. Głównym celem było opracowanie optoelektronicznego systemu pomiarowego, na którego potrzeby zastosowano przestrzennie selektywną optyczną spektroskopię emisyjną dedykowaną do badania procesu...
-
A randomized and controlled study of noninvasive hemodynamic monitoring as a guide to drug treatment of uncontrolled hypertensive patients
Publication -
The impact of an electronic monitoring and reminder device on patient compliance with antihypertensive therapy: a randomized controlled trial
Publication -
Chromatic monitoring technique for thickness measurementof thin transparent films.IV Workshopon Atomic and Molecular Physics.
PublicationW pracy opisano nową technikę monitorowania grubości cienkich warstw podczas procesu ich syntezy. Jest to optyczna metoda oparta na zdegenerowanej analizie widmowej tzw. modulacji chromatycznej. Umożliwia ona precyzyjny ciągły pomiar zmian grubości wzrastających warstw stosowanych w optyce.
-
Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
PublicationOpisano konstrukcję oraz badania laboratoryjne modelu nowego automatycznego analizatora śladowych ilości lotnych związków chlorowco-organicznych w wodzie do celów przemysłowych (o wysokiej czystości). Praca analizatora oparta jest na: - przeciwprądowym ciągłym wypłukiwaniu analitów ze strumienia próbki, - okresowym zatrzymywaniu uwolnionych analitów na złożu sorbenta, - desorpcji termicznej, - oznaczaniu sumy związków chlorowco-organicznych...
-
Conception of on-line lamella´s thickness monitoring system for resawing process on sash-gangs saw
PublicationPrzedstawiono układ do automatycznego pomiaru grubości lameli po cięciu na pilarkach ramowych. Pomiar odbywa się metodą bezstykową za pomocą ultra precyzyjnych laserowych sensorów przemieszczeń. Sygnały z sensorów po obrobieniu za pomocą specjalnego oprogramowania były podstawą do oceny jakości wykonania lameli. Próby cięcia wykonano na pilarce ramowej PRW15M na Politechnice Gdańskiej, a pomiary na Shimane University w Matsue (Japonia)....
-
Monitoring technologicznych ram zabezpieczenia przejść poprzecznych tunelu pod Martwą Wisłą w Gdańsku
PublicationPraca dotyczy systemu pomiarowego zastosowanego podczas monitoringu ram technologicznych wspierających drążenie przejść poprzecznych łączących oba główne korytarze tunelu pod Martwą Wisłą w Gdańsku. W pracy przedstawiono wyniki badań dwóch typów ram, uzyskane podczas wykonywania dwóch przejść. Wyniki pomiarów pozwalają na określenie stanu wytężenia konstrukcji ram w czasie prowadzenia robót oraz na oszacowaniu rzeczywistego stanu...
-
Nadmierne osiadania nawierzchni drogowej w ujęciu geotechnicznym – przyczyny, monitoring, możliwe metody naprawy
PublicationNadmierne osiadania nawierzchni stanowią „wieczny” problem użytkowników dróg. Z odkształceniami nawierzchni łączy się obniżenie komfortu i bezpieczeństwa jazdy (BRD). Jedną z podstawowych przyczyn takiego zjawiska jest zachowanie się podłoża gruntowego. Najczęściej dotyczy to zjawiska osiadania podłoża gruntowego, stanowiącego efekt ściśliwości gruntów w wyniku przyłożenia obciążenia i jest przekroczeniem stanów granicznych użytkowalności...
-
Real-time monitoring of the emission of volatile organic compounds from polylactide 3D printing filaments
PublicationEstablishing the emission profile of volatile organic compounds generated during fused deposition modeling 3D printing using polymer filaments is important in terms of both understanding the processes taking place during thermal degradation of thermoplastics, and assessing the user's exposure to potentially harmful volatiles. However, obtaining detailed, real-time qualitative and quantitative results poses a challenge. In this...
-
Real-time monitoring of volatiles and particles emitted from thermoplastic filaments during 3D printing
PublicationPresentation on the use of instrumental analytical techniques for the assessment of emission of volatiles and particulates during fdm 3d printing.
-
Nadmierne osiadania nawierzchni drogowej w ujęciu geotechnicznym - przyczyny, monitoring, możliwe metody naprawy
PublicationNadmierne osiadania nawierzchni stanowią „wieczny” problem użytkowników dróg. Z odkształceniami nawierzchni łączy się obniżenie komfortu i bezpieczeństwa jazdy (BRD). Jedną z podstawowych przyczyn takiego zjawiska jest zachowanie się podłoża gruntowego. Najczęściej dotyczy to zjawiska osiadania podłoża gruntowego, stanowiącego efekt ściśliwości gruntów w wyniku przyłożenia obciążenia i jest przekroczeniem stanów granicznych użytkowalności...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublicationThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Energy consumption optimization in wastewater treatment plants: Machine learning for monitoring incineration of sewage sludge
PublicationBiomass management in terms of energy consumption optimization has become a recent challenge for developed countries. Nevertheless, the multiplicity of materials and operating parameters controlling energy consumption in wastewater treatment plants necessitates the need for sophisticated well-organized disciplines in order to minimize energy consumption and dissipation. Sewage sludge (SS) disposal management is the key stage of...
-
Continuous blood pressure monitoring by photoplethysmography - signal preprocessing requirements based on blood flow modelling
PublicationObjective. The aim of the study is to investigate the effect of the signal sampling frequency and low-pass filtering on the accuracy of the localisation of the fiducial points of the photoplethysmographic signal (PPG), and thus on the estimation of the blood pressure (i.e. the accuracy of the estimation). Approach. Statistical analysis was performed on 3,799 data samples taken from a publicly available database. Four PPGfiducial...
-
Optical sensor of a person sitting on a chair and dressed in multi-layered clothes vital signs monitoring
PublicationAn optoelectronic device enhancing a smart chair functionality is presented in the paper. Its essential purpose is a detection of a sitting person presence on the chair by means of detecting the vital signs. Additionally, it could be used for determining of clothes layer parameters useful in adjusting a system of a capacitive electrocardiography.
-
Meconium analysis as a promising diagnostic tool for monitoring fetal exposure to toxic substances: Recent trends and perspectives
PublicationPrenatal exposure to toxic substances is an important public health problem. Many biological specimens obtained from the fetus or mother are used for biomonitoring. Each material reflects exposure in a specific time period and has different advantages and disadvantages in terms of accuracy, time window of detection and cost/benefit ratio. Recently, meconium has become the matrix of choice in toxicology screening for detecting exposure...
-
Diagnostyka i modernizacja konstrukcji nawierzchni drogowych. Diagnostyka, monitoring i modernizacja eksploatowanych obiektów budowlanych.
PublicationArtykuł przedstawia metody diagnostyki oraz metody modernizacji konstrukcji nawierzchni drogowej w Polsce, w porównaniu do światowych osiągnięć w tej dziedzinie. Artykuł przedstawia kolejno: opis potrzeb modernizacji nawierzchni drogowych oraz jej rolę w Systemie Zarządzania Nawierzchniami (PMS), metody oceny cech funkcjonalnych i strukturalnych nawierzchni, metody modernizacji i remontów nawierzchni. Główny nacisk położono na...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublicationTime-weighted average concentrations of selected volatile compounds were measured in chosen residences in a Tri-City area of Poland by means of passive sampling. The results were compared to those obtained by dynamic technique – sorption tubes filled with Tenax TA sorbent. Results obtained by employing the two techniques were similar. Total volatile organic compound (TVOC) parameters were also determined. An attempt was also...
-
The impedance method of monitoring the degradation of rubber linings in applications where progressive deterioration is the predominant failure mechanism
Publication -
<title>Satellite monitoring of spatial variability in the Baltic Sea ecosystem: possible applications of the DESAMBEM algorithm</title>
Publication -
Model Based Monitoring of Dynamic Loads and Remaining Useful Life Prediction in Rolling Mills and Heavy Machinery
Publication -
PUB073 Lung Cancer Screening with LDCT – Results of a Small Cohort Continual Monitoring (Pilot Silesian Study)
Publication -
The application of isotopically labeled analogues for the determination of small organic compounds by GC/MS with selected ion monitoring
Publication