Filters
total: 4625
filtered: 3370
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: OPTICAL STRAIN MEASUREMENT
-
Optical properties of boron-doped nanocrystalline diamond films studied by spectroscopic ellipsometry
PublicationThe optical properties of boron-doped nanocrystalline diamond films, coated using Microwave Plasma Enhanced Chemical Vapour Deposition (μPE CVD) system, were analyzed by spectroscopic ellipsometry. Diamond films were deposited on silicon substrates. The ellipsometry data (refractive index (n(λ)), extinction coefficient (k(λ)) were modeled using dedicated software. Evolution of the optical structure with boron doping was observed...
-
Liquid crystalline optical components for application in optical sensing
PublicationW artykule opisano proces wytwarzania pryzmatów Wollastona na bazie roztworu ciekłokrystalicznego ZLI-1957 i płytek falowych na bazie prekursora polimeru ciekłokrystalicznego RMS03-001. Przedstawiono uzyskane parametry optyczne elementów pod kątem ich potencjalnych aplikacji
-
Photogrammetric and total station's measurement of compressed column's model
PublicationModelling studies continue to play an important role. One of such study is stress determination in the reinforcement bars of reinforced columns and determine column's axis deformation. The article presents measurements results of control points located on the model of reinforced concrete column. The column was compressed in few series till it's destruction. In this studies, photogrammetric method and total station measurements...
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublicationThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublicationIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
New concept of a measurement probe for high impedance spectrocopy
PublicationArtykuł przedstawia nową koncepcję sondy pomiarowej służącej jako obwód wejściowy analizatora do spektroskopii wysokoimpedancyjnej. Dzięki wykorzystaniu przetwornika prąd na napięcie uzyskano najmniejszy możliwy wpływ pojemności kabli dołączających mierzony obiekt na wynik pomiaru. Przeprowadzono analizę sondy biorąc pod uwagę najważniejsze parametry wpływające na dokładność pomiaru: pojemności pasożytnicze oraz rzeczywiste parametry...
-
Noise measurement setups for fluctuations enhanced gas sensing
PublicationObserwacje zjawisk fluktuacyjnych w sensorach gazów pozwala zwiększyć czułość i selektywność detekcji gazów. Problemem jest budowa prostego i taniego systemu do obserwacji tych zjawisk. W artykule przedstawiono dwa systemy pozwalające na obserwacje szumów w rezystancyjnych sensorach gazów dostępnych na rynku i prototypowych, wykonanych z warstwy nanocząstek o zbliżonych wymiarach.
-
Radio Link Measurement Methodology for Location Service Applications
PublicationThe aim of this paper is the methodology of measurements executed in a radio link for the realization of radiolocation services in radiocommunication networks, particularly in cellular networks. The main results of the measurements obtained in the physical layer of the universal mobile telecommunications system (UMTS) are introduced. A new method for the utilization of the multipath propagation phenomenon to improve the estimation...
-
Measurement microsystem for high impedance spectroscopy of anticorrosion coatings
PublicationW artykule przedstawiono mikrosystem do pomiarów bardzo dużych impedancji ukierunkowany na identyfikację parametrów powłok antykorozyjnych metodą spektroskopii impedancyjnej. Do wyznaczania składowych ortogonalnych sygnałów pomiarowych zastosowano w nim technikę cyfrowego przetwarzania sygnałów. Pozwoliła ona na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich, od ćHz, przy zachowaniu prostej konstrukcji...
-
Cost-Efficient Optical Fronthaul Architectures for 5G and Future 6G Networks
PublicationFifth-generation and Beyond (5GB) wireless networks have introduced new centralized architectures such as cloud radio access network (CRAN), which necessitate extremely high-capacity low latency Fronthaul (FH). CRAN has many advantageous features in terms of cost reduction, performance enhancement, ease of deployment, and centralization of network management. Nevertheless, designing and deploying a cost-efficient FH is still a...
-
Structural and optical investigations of sol-gel derived lithium titanate thin films
Publicationin this paper structural and optical studies of lithium titanate (lto) thin films are presented. nanocrystalline thin films with 800 nm thickness were prepared by sol-gel method. to examine the influence of the annealing time on as-prepared films crystallization, the coatings were heated at 550 °c for 10, 20 and 80 h. structure of manufactured thin films was investigated using x-ray diffraction (xrd). the most visible lithium titanate...
-
Analysis of measurement uncertainty for contact-less method used to measure the position of catenary contact wire, performed with the use of Monte Carlo method
PublicationCurrently the majority of main railway lines in Europe are electrified, and electric trains have the biggest share in the entire amount of rail transport. Reliability of electrified railways is closely related to the issue of supplying traction vehicles with energy. The problems connected with diagnostics of energy consumption node, namely the contact line and the current collector, are therefore of fundamental importance for maintaining...
-
New Simple and Robust Method for Determination of Polarity of Deep Eutectic Solvents (DESs) by Means of Contact Angle Measurement
PublicationThe paper presents a new method for evaluating the polarity and hydrophobicity of deep eutectic solvents (DESs) based on the measurement of the DES contact angle on glass. DESs consisting of benzoic acid derivatives and quaternary ammonium chlorides–tetrabutylammonium chloride (TBAC) and benzyldimethylhexadecylammonium chloride (16-BAC)—in selected molar ratios were chosen for the study. To investigate the DESs polarity, an optical...
-
Stress–strain model of lower corroded steel plates of normal strength for fitness-for-purpose analyses
PublicationThis study investigates the mechanical properties of specimens made of normal strength steel subjected to lower marine immersed corrosion degradation levels (below 25 %). The specimens were corroded in laboratory conditions, and only natural factors were controlled to raise the corrosion rate (reaching the level of 1 mm/year). Three different thicknesses of plates made of normal strength of shipbuilding steel are investigated (between...
-
Measurement system based on USB Z-Wave controller
PublicationA wireless measurement system based on the Z-Wave standard is presented in this paper. The system is composed of a U SB Z-Stick Gen5 controller connected to a Personal Computer and a Fibaro controller FGRGBWM-441. Operation of the system is controlled by software written in C++ using OpenZWave library. Some metrological aspects of the system are evaluated: accuracy, linearity, resolution and frequency of voltage measurements.
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
PROGRAMMABLE YANG - BASED INTERFACE IN CONTROL OF OPTICAL TRANSPORT NETWORK
PublicationSince over a decade we observe intensive effort of research institutions and industrial consortia on extending flexibility and automation of the transport network control also known under the term network programmability. Key aspect of each programming interface is ability to evolve but also sensitivity to future modifications. As indicated in the past work in the specific context of optical transport networks an important criterion...
-
How to apply the probabilistic model of measurement processes successfully
PublicationApplicational aspects of probabilistic model of measurement processes, proposed by G.B. Rossi, are considered. The main idea of the model - using of Bayes-Laplace postulate for solution of inverse probability problem, is substituted by Fisher's concept of the likelihood function, expressed in the data translated format. This approach gives a clear-sighted solution of inverse probability. Some recommendations for application of...
-
Automated measurement method for assessing thermal-dependent electronic characteristics of thin boron-doped diamond-graphene nanowall structures
PublicationThis paper investigates the electrical properties of boron-doped diamond-graphene (B:DG) nanostructures, focusing on their semiconductor characteristics. These nanostructures are synthesized on fused silica glass and Si wafer substrates to compare their behaviour on different surfaces. A specialized measurement system, incorporating Python-automated code, was developed for an in-depth analysis of electronic properties under various...
-
INFLUENCE OF WRONGLY ASSUMED PROBABILITY DISTRIBUTION ON THE UNCERTAINTY OF RESISTANCE MEASUREMENT BY TECHNICAL METHOD
PublicationThe paper presents studies on the influence of probability distributions on the expanded uncertainty of the resistance measurement. Choosing the correct probability distribution is very important to estimate of measurement uncertainty. The most commonly used distribution is the rectangular distribution. The paper presents the results of analysis of the resistance measurement uncertainty using the technical method of two resistances:...
-
Model of optical phantoms thermal response upon irradiation with 975 nm dermatological laser
PublicationWe have developed a numerical model describing the optical and thermal behavior of optical tissue phantoms upon laser irradiation. According to our previous studies, the phantoms can be used as substitute of real skin from the optical, as well as thermal point of view. However, the thermal parameters are not entirely similar to those of real tissues thus there is a need to develop mathematical model, describing the thermal and...
-
Nanocrystalline diamond sheets as protective coatings for fiber-optic measurement head
PublicationFiber-optic sensors find numerous applications in science and industry, but their full potential is limited because of the risk of damaging the measurement head, in particular, due to the vulnerability of unprotected tips of the fiber to mechanical damage and aggressive chemical agents. In this paper, we report the first use of a new nanocrystalline diamond structure in a fiber-optic measurement head as a protective coating of...
-
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublicationIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublicationNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublicationMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Distributed measurement system with data transmission secured using XXTEA algorithm
PublicationThe paper deals with wireless data transmission security in the distributed measurement and control system. An overview of cryptographic algorithms was presented paying special attention to the algorithm dedicated to units with low processing power, which is important due to minimization of energy consumption. Measurement modules equipped with simple microcontrollers send data wirelessly to the central unit. The transmission was...
-
Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants
PublicationThe study presents information about the measurement techniques used for the assessment of air quality in terms of the olfactory intensity resulting from the operation of municipal sewage treatment plants. Advantages and disadvantages of the measurement techniques used are presented. Sources of malodourous substance emission from sewage treatment plants were described, and the malodourous substances emitted were characterised....
-
Planning a Cost-Effective Delay-Constrained Passive Optical Network for 5G Fronthaul
PublicationWith the rapid growth in the telecommunications industry moving towards 5G and beyond (5GB) and the emergence of data-hungry and time-sensitive applications, Mobile Network Operators (MNOs) are faced with a considerable challenge to keep up with these new demands. Cloud radio access network (CRAN) has emerged as a cost-effective architecture that improves 5GB performance. The fronthaul segment of the CRAN necessitates a high-capacity...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublicationThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Comparison of Different Measurement Techniques as Methodology for Surveying and Monitoring Stainless Steel Chimneys
PublicationThe measurement of a chimney axis is an engineering geodesy task. These measurements allow to assess the technical condition of chimneys and are usually carried out for reinforced concrete chimneys. When measuring high chimneys, the main problem may be the need to go a long distance to take a measurement. The surface of the chimney can also be problematic because it can absorb so much light from the range finder that total station...
-
Visual measurement system for chosen parameters of current collectors
PublicationA current collector is an element in a traction vehicle, used for movable, contact con-nection between the main circuit of this vehicle and the contact line. Bad technical condi-tion of these important elements in the main circuit of the vehicle result in its incorrect cooperation with contact line. Periodic control of technical condition of current collectors ensures infallible current collection. The pantograph diagnostics consists...
-
Dynamic mass measurement in checkweighers using a discrete time-variant low-pass filter
PublicationConveyor belt type checkweighers are complex mechanical systems consisting of a weighing sensor (strain gauge load cell, electrodynamically compensated load cell), packages (of different shapes, made of different materials) and a transport system (motors, gears, rollers). Disturbances generated by the vibrating parts of such a system are reflected in the signal power spectra in a form of strong spectral peaks, located usually in...
-
Investigation of optical properties of Infitec and Active Stereo stereoscopic techniques for CAVE-type virtual reality systems
PublicationIn recent years, many scientific and industrial centres in the world developed virtual reality systems or laboratories. At present, among the most advanced virtual reality systems are CAVE-type (Cave Automatic Virtual Environment) installations. Such systems usually consist of four, five, or six projection screens arranged in the form of a closed or hemi-closed space. The basic task of such systems is to ensure the effect of user...
-
The Double Cognitive Bias of Mistakes: A Measurement Method
PublicationThere is no learning without mistakes. However, making mistakes among knowledge workers is s�ll seeing shameful. There is a clash between posi�ve a�tudes and beliefs regarding the power of gaining new (tacit) knowledge by ac�ng in new contexts and nega�ve a�tudes and beliefs toward accompanying mistakes that are sources of learning. These contradictory a�tudes create a bias that is doubled by the other shared solid belief...
-
Detection of immunological agent by optical fiber sensor: preliminary study
PublicationThe objective of this study is the application of optical methods for detection of immunological agent concentration. As the agent we used the Cyclaid, produced by Apotex Inc. In this article we investigated different Cyclaid concentrations in water. We used a Fabry-Pérot interferometer working in a reflective mode, the measurements were performed with source with central wavelength λ = 1550 nm. The preliminary investigation have...
-
Electrochemical performance of indium-tin-oxide-coated lossy-mode resonance optical fiber sensor
PublicationAnalysis of liquids performed in multiple domain, e.g., optical and electrochemical (EC), has recently focus significant attention. Our previous works have shown that a simple device based on indium-tin-oxide (ITO) coated optical fiber core may be used for optical monitoring of EC processes. At satisfying optical properties and thickness of ITO a lossy-mode resonance (LMR) effect can be obtained and used for monitoring of optical...
-
Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer
PublicationThe discords concerning the measurement uncertainty evaluation in the Guide to the Expressing of Uncertainty in Measurement (GUM) and its Supplement 1 are considered. To overcome these discords, the authors of the paper propose to use the kurtosis method and the law of the propagation of the expanded uncertainty. Using the example of the goniometer calibration, the features of accounting for the distribution laws of input quantities...
-
Revisiting the Measurement of Anomie
Publication -
Simultaneous optical and electrochemical label-free biosensing with ITO-coated lossy-mode resonance sensor
PublicationIn this work we discuss a new label-free biosensing device based on indium tin oxide (ITO) overlaid section of a multimode optical fiber fused silica core. The sensor has been used to optical measurements also simultaneously interrogated electrochemically (EC). Due to optimized thickness and optical properties of ITO film, a lossy-mode resonance (LMR) could be observed in the optical domain, where electrical properties of the film...
-
Peculiarities of measurement uncertainty evaluation at calibrating a ring gauge
PublicationExample S13 from EA-4/02 M:2013 “Calibration of a ring gauge with a nominal diameter of 90 mm” is analyzed. The report uses the kurtosis method and the law of propagation of expanded uncertainty developed by the authors to the expanded uncertainty evaluation. It is shown that the introduction of a coaxiality correction for the ring gauge and the measuring axis of the comparator leads to the need to estimate its standard measurement...
-
Optoelectronic and non-linear optical properties of Lu-doped AgGaGe3Se8 crystallites
Publication -
Filtering of interference signals of grounding resistance measurement with subharmonic method
PublicationOmówiono metodę filtracji zakłóceń o częstotliwości sieciowej wraz z wyższymi harmonicznymi poprzez zastosowanie metody szczególnego próbkowania z podharmonicznym sygnałem pomiarowym.
-
Optical activity and electro-optic effect of l-arginine doped KDP single crystals
PublicationWe have used the modified polarimetric methods to study optical activity (OA) in the potassium dihydrogenphosphate (KDP) crystals doped with 0.7, 1.4 and 3.8 wt% L-arginine (L-arg) amino acid. Crystals were grown by the temperature reduction method. Small changes of the absolute eigen waves ellipticity and OA values in doped crystals were noted. We have experimentally determined the signs of OA in the [1 00] and [01 0] directions...
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublicationThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...
-
Efficient signal processing in spectroscopic optical coherence tomography
PublicationSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Semi complex navigation with an active optical gesture sensor
PublicationThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
Detection of petroleum products using optical coherence tomography
PublicationIn this work, we present a novel method developed for the analysis of the properties of thin layers for detecting petroleum products on a water surface using a commercially available optical coherence tomography (OCT) system. The spectral density analysis of the signal from a spectroscopic OCT (S-OCT) enables us to perform the precision calculation of the thin layer thickness and other properties like homogeneity, and dispersion,...
-
Design of Cost-Efficient Optical Fronthaul for 5G/6G Networks: An Optimization Perspective
PublicationCurrently, 5G and the forthcoming 6G mobile communication systems are the most promising cellular generations expected to beat the growing hunger for bandwidth and enable the fully connected world presented by the Internet of Everything (IoE). The cloud radio access network (CRAN) has been proposed as a promising architecture for meeting the needs and goals of 5G/6G (5G and beyond) networks. Nevertheless, the provisioning of cost-efficient...
-
Measurement of temperature at sliding polymer surface by grindable thermocouples
PublicationThis paper is devoted to experimental study of capabilities and limitations of grindable thermocouples as applied to polymer materials sliding on metal. Chromel–alumel and chromel–copel grindable thermocouples have been developed and tested for wide ranges of contact pressure and sliding velocity. The background temperature of the sliding surface can be determined as the lower envelope of the signal from the grindable thermocouple....