Search results for: POTENTIAL MEASUREMENT
-
CZYNNIKI DECYDUJĄCE O PRZYDATNOŚCI KOMPUTEROWEGO MODELU PRZEPŁYWÓW W SIECI WODOCIĄGOWEJ
PublicationW pracy poddano analizie wielozadaniowy proces tworzenia komputerowego modelu przepływów. W efekcie zidentyfikowano szereg czynników ograniczających obszar stosowania modelu w praktyce inżynierskiej. W zakresie pozyskiwania danych strukturalnych i operacyjnych wskazano potencjalne źródła błędów, które przyczyniają się do zmniejszenia dokładności odwzorowania stanu rzeczywistego. Specjalną rangę nadano specyfikacji czynników związanych...
-
An Example of Using Low-Cost LiDAR Technology for 3D Modeling and Assessment of Degradation of Heritage Structures and Buildings
PublicationThis article examines the potential of low-cost LiDAR technology for 3D modeling and assessment of the degradation of historic buildings, using a section of the Koszalin city walls in Poland as a case study. Traditional terrestrial laser scanning (TLS) offers high accuracy but is expensive. The study assessed whether more accessible LiDAR options, such as those integrated with mobile devices such as the Apple iPad Pro, can serve...
-
A new method of presosns identification based on comparative analysis of 3D face models
PublicationThe article presents the use of modern close range photogrammetry for possessing highly accurate 3D models of the human face (including the ears). Modern methods used to obtain precise data describing the construction of a human face, and even the whole human body, should allow to get finished measurement material in a very short time. Those features belong to the optical scanning technology. Comparative analysis of models of the...
-
A Comprehensive Analysis of Impedance of the Electrochemical Cell
PublicationA comprehensive impedance characteristics of two electrodes electrochemical cell has been pre sented. In this method a multisinusoidal current excitation signal is used. The change of potential of both the electrodes are all registered as a function of time. The proposed method gives the possibility of determining the impedance of both electrodes individually as well as the impedance of a twoelectrode system. Additional application...
-
Measurement data of cyclic voltammetry and electrochemical impedance measurements of carbon samples synthesized on axes and off axes
Open Research DataThe electrochemical performance of the multielectrode samples were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) using a VMP-300 BioLogic galvanostat potentiostat (France) under the EC-lab software. All electrochemical investigations were carried out in a three-electrode cell system. The carbon multi-electrode,...
-
Potential energy curve, rovibrational energies and nuclear wave functions of 2 singlet Pi state in KLi dimer
Open Research DataThis data sets contains potential energy curve, energy levels and nuclear wave functions of rovibrational states of KLi dimer in 2 singlet Pi electronic state. Potential energy curve (PEC) for the electronic state was calculated in the Born-Oppenheimer approximation by the means of effective core potentials and MRCI method. Nuclear wave functions and...
-
Robust estimation of deformation from observation differences for free control networks
PublicationDeformation measurements have a repeatable nature. This means that deformation measurements are performed often with the same equipment, methods, geometric conditions and in a similar environment in epochs 1 and 2 (e.g., a fully automated, continuous control measurements). It is, therefore, reasonable to assume that the results of deformation measurements can be distorted by both random errors and by some non-random errors, which...
-
Electrocatalytic gas sensor with reference layer
PublicationIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
This dataset contains results of our investigation aiming in determination of antioxidant potential of the propolis extract produced in our laboratory.
Open Research DataThis dataset contains results of our investigation aiming in determination of antioxidant potential of the propolis extract produced in our laboratory. The propolis samples were delivered by Polish beekeepers. DPPH and FREAP methods were used. Moreover, total phenolic contents in the extracts were determined.
-
The potential interaction of environmental pollutants and circadian rhythm regulations that may cause leukemia
PublicationTumor suppressor genes are highly affected during the development of leukemia, including circadian clock genes. Circadian rhythms constitute an evolutionary molecular machinery involving many genes, such as BMAL1, CLOCK, CRY1, CRY2, PER1, PER2, REV-ERBa, and RORA, for tracking time and optimizing daily life during day-night cycles and seasonal changes. For circulating blood cells many of these genes coordinate their proliferation,...
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021247401]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021242361]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021241571]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021243311]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021246131]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021245961]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021242491]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021246271]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021248921]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021247121]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021243701]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021246111]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021241011]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021246081]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021244491]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Smooth muscle tumor of uncertain malignant potential - Female, 10 - Tissue image [5170730021245751]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The absorption and fluorescence spectra of C-1305 derivatives (IKE1-IKE8), potential antifungal agents
Open Research DataOptical measurements of C-1305 derivatives (IKE1-IKE8). The absorption spectra were recorded at 300 - 800 nm for solutions with 16 μg / mL derivative concentration. The fluorescence emission spectra were determined at 420-800 nm with the excitation wavelengths 360 or 415 nm for solutions with 1 μg / mL derivative concentration. All measurements were...
-
Electrical and noise responses of the ink-printed MoS2-based gas sensor for sensing of NO2, NH3 and C3H6O under UV light (275 nm)
Open Research DataThis data set consists of DC data, low-frequency noise spectra data and UV-vis spectroscopy data collected for ink-printed MoS2-based resistive sensors (2D MoS2 overlapping flakes creating a continuous layer on the ceramic substrate). The sensors were investigated toward three target gases - nitrogen dioxide (1-10 ppm), ammonia (2-12 ppm) and acetone...
-
DataSet Investigations into the quality of urban stormwater outflow as an alternative water source: potential for landscape irrigation reuse
Open Research DataInvestigations into the quality of urban stormwater outflow as an alternative water source: potential for landscape irrigation reuse
-
Raman miniaturised system for field applications
PublicationRaman spectroscopy is a powerful and versatile research technique with a broad range of potential applications, which includes laboratory studies, on-line industrial process monitoring and field measurements. Scope of the field applications includes environment monitoring, detection of dangerous or prohibited materials and rapid identification of unknown samples. It stimulates development of dedicated Raman measurement equipment...
-
3D Machine Vision System for Inspection of Contact Strips in Railway Vehicle Current Collectors
PublicationConstruction and technical condition of current collectors is crucial to reliability and safety of railway transportation. According to the Technical Specifications for Interoperability railway vehicles in the European Union should be equipped with carbon contact strips. Excessive wear or defects of contact strips degrade the capability of undisturbed power transmission, cause faster wear of contact wire, and can even result in...
-
Monitoring Artificial Light Pollution Using a Multispectral Camera
PublicationStudying the adverse effects of artificial light pollution requires systematic monitoring using various methods. One commonly used technique involves assessing the intensity of light reflected from surfaces with different types of digital cameras at various measurement levels. However, this approach does not always fully capture the characteristics of the light source itself. In our study, we focused on the potential application...
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [617073002674451]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026743851]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026749991]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Multilocular cystic renal neoplasm of low malignant potential - Male, 42 - Tissue image [6170730026745981]
Open Research DataThis is the histopathological image of KIDNEY tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
The absorption and fluorescence spectra of novel bisacridines (IKE15-19, IKE21) and IE10, potential antifungal agents
Open Research DataOptical measurements of novel bisacridines (IKE15-19, IKE21) and IE10 were conducted. The absorption spectra were recorded from 300 to 800 nm. The fluorescence emission spectra were determined with excitation and emission wavelengths described in the file. All measurements were recorded using a multiplate reader, Tecan Spark 10M.
-
Electrophoretic deposition and characterization of composite chitosan/Eudragit E 100 or poly(4-vinylpyridine)/mesoporous bioactive glass nanoparticles coatings on pre-treated titanium for implant applications
PublicationTitanium implants are surface-modified to achieve bioactivity and often antibacterial properties. Such surface coatings may increase corrosion degradation and be weakly attached to the substrate. In the present research, biodegradable composite coatings, investigated so far as smart environment-sensitive, slowly releasing silver to the implant neighborhood, were produced as a combination of chitosan (CS) with Eudragit E 100 (EE100)...
-
The electrochemical response to glassy carbon electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the glassy carbon GC electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration,...
-
Full CI ground state potential energy curves and one-electron relativistic corrections for hydrogen molecule in various basis sets
Open Research DataThis dataset consists of Full CI ground state Born-Oppenheimer potential energy curves and one-electron relativistic corrections for hydrogen dimer. Nonrelativistic energies, as well as one electron relativistic corrections (treated perturbatively with help of the Cowan-Griffin Hamiltonian) are presented for internuclear distances between 0.8 and 10...
-
Noise and Electro-Ultrasonic Spectroscopy of Conducting PolymerThick Films
PublicationThick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On the conducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting...
-
THE PROTECTIVE MEASURES AGAINST SARS-COV-2 INFECTION IN THE SEAFOOD COMPANY FROM THE PERSPECTIVE OF THE EMPLOYEES
PublicationPurpose: To identify and discuss the protective measures implemented to prevent SARS-CoV-2 infection among employees. Design/methodology/approach: The four-stage course of research. Case study and structured interviews with all employees, directly and indirectly, involved in food processing. Research questions: (R1) What measures have been taken to prevent the risk of infection among employees? (R2) What activities and responsibilities...
-
Influence of selected additives and admixtures on underwater concrete and the environment
PublicationThe intensive civilization development has an influence on searching for new possibilities connected with extension of city agglomerations, both the areas of flat building and the industrial areas. One of the most interesting solution is to use water reservoirs, rivers and sea areas. The extension of buildings has an influence on building materials, especially hydrotechnical, which means development of production of hydrotechnical...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublicationThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublicationThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Potential diagnostic utility of recombinant Toxoplasma gondii proteins for detecting anti-Toxoplasma gondii IgG antibodies in horses serum samples
Open Research DataToxoplasmosis is caused by an intracellular protozoan, Toxoplasma gondii, and is a parasitic disease that occurs in all warm-blooded animals, including humans. Toxoplasmosis is one of the most common parasitic diseases of animals and results in reproductive losses. Diagnosis of toxoplasmosis is currently based on serological assays using native antigens...
-
Potential diagnostic utility of recombinant Toxoplasma gondii proteins for detecting anti-Toxoplasma gondii IgG antibodies in goat serum samples
Open Research DataToxoplasmosis is caused by an intracellular protozoan, Toxoplasma gondii, and is a parasitic disease that occurs in all warm-blooded animals, including humans. Toxoplasmosis is one of the most common parasitic diseases of animals and results in reproductive losses. Diagnosis of toxoplasmosis is currently based on serological assays using native antigens...
-
Potential diagnostic utility of recombinant Toxoplasma gondii proteins for detecting anti-Toxoplasma gondii IgG antibodies in feline serum samples
Open Research DataToxoplasmosis is caused by an intracellular protozoan, Toxoplasma gondii, and is a parasitic disease that occurs in all warm-blooded animals, including humans. Toxoplasmosis is one of the most common parasitic diseases of animals and results in reproductive losses. Diagnosis of toxoplasmosis is currently based on serological assays using native antigens...
-
Flap Monitoring Techniques: A Review
PublicationPostoperative tissue flap vitality monitoring enables early detection of clinical complications, allowing for intervention. Timely re-operation can prevent the need for extensive correction procedures, thus reducing healthcare costs and hospitalisation time. Statistics show that monitoring can increase the success rate of flap survival to 95\% or higher. However, despite the significant progress in monitoring techniques, major...
-
Deep eutectic solvents with solid supports used in microextraction processes applied for endocrine-disrupting chemicals
PublicationThe determination of endocrine-disrupting chemicals (EDCs) has become one of the biggest challenges in Analytical Chemistry. Due to the low concentration of these compounds in different kinds of samples, it becomes necessary to employ efficient sample preparation methods and sensitive measurement techniques to achieve low limits of detection. This issue becomes even more struggling when the principles of the Green Analytical Chemistry...