Search results for: temperature measurement
-
Experimental data of galvanic electric cells measurements
Open Research DataInternal temperature of an electric cell can be measured and monitored using microsphere-based fiber-optic sensors with thin ALD ZnO coating. Their compact size will allow to integrate them easily and effectively within the electric cells. Utilization of presented sensors allows to detect, in real time, damages to the structure of the sensor head that...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublicationElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Investigation of Weigh-in-Motion Measurement Accuracy on the Basis of Steering Axle Load Spectra
PublicationWeigh-in-motion systems are installed in pavements or on bridges to identify and reduce the number of overloaded vehicles and minimise their adverse eect on road infrastructure. Moreover, the collected trac data are used to obtain axle load characteristics, which are very useful in road infrastructure design. Practical application of data from weigh-in-motion has become more common recently, which calls for adequate attention to...
-
DIAGNOSTIC INFORMATION ANALYSIS OF QUICKLY CHANGING TEMPERATURE OF EXHAUST GAS FROM MARINE DIESEL ENGINE PART I SINGLE FACTOR ANALYSIS
PublicationIn this paper, attention was paid to the problem of low controllability of marine medium- and high-speed engines during operation, which significantly limits the parametric diagnosis. The measurement of quickly changing temperature of engine exhaust gas was proposed, the courses of which can be a source of diagnostic information. The F statistic of the Fisher-Snedecor distribution was chosen as a statistical tool. Laboratory tests...
-
Application of infrared thermoography to non-contact testing of varistors
PublicationTesting of varistors using thermography was carried out in order to assess their protective properties against possible overvoltage phenomena in the form of high-level voltage surges. An advantage of the thermography technique is non-contact temperature measurement. It was proposed to assess the properties of varistors workingin electronic devices as protective elements, on the basis of estimating temperature increments on varist...
-
Leakage Current Measurements of Surge Arresters
PublicationThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
PublicationA unique highly sensitive photonic crystal fiber is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained...
-
Empirical Relationship Describing Total Convective and Radiative Heat Loss in Buildings
PublicationOn the basis of theoretical considerations of convective-radiative heat transfer, a relationship was developed enabling the total convective and radiative heat flux QC+R emitted from any object at tw and its surroundings at t∞ to be calculated from known values of the surface temperature of such an object, i.e., the known temperature difference Δt=tw - t∞ and average air temperature Tav. This relationship is applied to thermal...
-
Experimental research of the stability of steel cylindricalshell subjected to circumferential compression
PublicationAt the Department of Metal Structures Gdańsk University of Technology, experiments have been performed on the stability of shell of steel cylindrical models. The experiments have been carried on a test bench built at the Department. The design based on other test benches which were created in the past by other scientists, where modernized by the courtesy of companies that offer modern solutions. The test bench enables to generate...
-
Measuring radioactive powder samples on the highresolution powder diffraction beamline at the European Synchrotron Radiation Facility
PublicationThis laboratory note describes a new sample preparation technique to enable high-resolution powder diffraction experiments at the European Synchrotron Radiation Facility on radioactive samples. The sample preparation involves setting the active material in resin and several layers of encapsulation suitable for measurement at the beamline. This has allowed low-temperature measurements on very small quantities of samples, providing...
-
Photocatalytic decomposition of acetaldehyde over TiO2 (titanium dioxide) supported on nickel foam and Ni-doped (nickel-doped) TiO2
Open Research DataThis dataset contains chromatograms recorded during the decomposition of acetaldehyde in a high-temperature reaction chamber under UV irradiation using as photocatalytic systems TiO2 (titanium dioxide) supported on nickel foam, TiO2 supported on oxidized nickel foam and TiO2 doped by metallic nickel (Ni) powder. The detailed equipment and measurement...
-
Series resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces area.
-
Changes in heat flow of V2O5 nanorods under oxidizing atmosphere
Open Research DataThe DataSet contains the DSC curves of V2O5 nanorods obtained at 650°C. The information about nanorods synthesis is described in the Journal of Nanomaterials.
-
Calculations of the resistance values of 20 thermistors at 100°C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calculations of the resistance values of 20 thermistors at 50°C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Thermal and technological aspects of double face grinding of Al2O3 ceramic materials
PublicationDouble face grinding with planetary kinematics is a process to manufacture workpieces with plan parallel functional surfaces, such as bearing rings or sealing shims. In order to increase the economic efficiency of this process, it has to be advanced permanently. The temperature in the contact zone of most grinding processes has a huge influence on the process efficiency and the workpiece qualities. In contrast to most grinding...
-
Application of an Electronic Nose Instrument to Fast Classification of Polish Honey Types
PublicationThe paper presents practical utilization of an electronic nose prototype, based on the FIGARO semiconductor sensors, in fast classification of Polish honey types—acacia flower, linden flower, rape, buckwheat and honeydew ones. A set of thermostating modules of the prototype provided gradient temperature characteristics of barbotage-prepared gas mixtures and stable measurement conditions. Three chemometric data analysis methods...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Area specific resistance (at 800 °C - 500 °C) of the Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered Sr0.86Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C, 1000 °C and 1050 °C. The measurement temperature range was between 800 °C and 500 °C in stationary air. Results converted to electrode surfaces...
-
Measurements of Thermal Conductivity of LWC Cement Composites Using Simplified Laboratory Scale Method
PublicationThe implementation of low-energy construction includes aspects related to technological and material research regarding thermal insulation. New solutions are sought, firstly, to reduce heat losses and, secondly, to improve the environment conditions in isolated rooms. The effective heat resistance of insulating materials is inversely proportional to temperature and humidity. Cement composites filled with lightweight artificial...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.50Fe0.50O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.50Fe0.50O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.30Fe0.70O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Series resistance (at 800 °C - 500 °C) of the SrTi0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the ohmic contribution of differently sintered Sr0Ti0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic ari flow (21% O2, 40 ml min-1). Results converted to electrode...
-
Calculations of the resistance values of 20 thermistors at 0°C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Investigation of low-temperature cracks on selected national roads and motorways in Poland 2020
Open Research DataThe dataset contains video investigation and records of 68 road sections in various parts of Poland. Videos were recorded with the use of two cameras: 1) mounted in front of measurement vehicle, which was focused on overall view of road and 2) which was focused on pavement surface. The records are categorized according to the ID of the section given...
-
The applicability of low-cost PM10 sensors for atmospheric air quality monitoring
PublicationDescribed in this work are the results of field tests carried out in the Tricity Agglomeration between 01 April 2018 and 30 June 2018 in order to evaluate the usefulness of low-cost PM10 sensors in atmospheric air quality monitoring. The results were juxtaposed with the results obtained using reference methods. The results were validated based on the measurement uncertainty as described in...
-
Measurements of the Hydraulic Fluids Compressibility
PublicationPerformance of the hydrostatic high-pressure drive systems is affected by the changes of working fluid’s volume. Presence of air bubbles in the fluid cause this problem to be even more serious. To study this phenomenon precise measurements of fluid’s bulk modulus are necessary. Differ-ent measurement methods are applied, but they are either limited to low pressure range or give inaccurate results. To solve the problem the new...
-
Determination of changes in viscosity of pectin gel depending on shear rate (1.7 to 85 s-1).
Open Research DataThe rheological characteristic of pectin gel (with concetration 0,25% m/m, in two independent repetitions) wasmade on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 27 spindle and shear rates from 1.7 to 85 s-1, in temperature of 25 C degee .The data allowed to characterize the used hydrogel preparations and assess...
-
Changes in heat flow of V2O5 nanorods under inert atmosphere
Open Research DataThe DataSet contains the DSC curves of V2O5 nanorods obtained at 650°C. The information about nanorods synthesis is described in the Journal of Nanomaterials.
-
Mobile wireless measurement system for potatoes storage management
PublicationThe paper discusses the idea and the design of a remote control system for a storage management of agricultural products which temperature may rise in a result of biological processes during the storage. Exemplary potatoes storehouse is discussed as an application of the automation system. Because of existing buildings and infrastructure in the farm, wireless data transfer system has been proposed for both sensors to data acquisition...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.50Fe0.50O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.50Fe0.50O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.30Fe0.70O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.65Fe0.35O3 porous oxygen electrodes sintered at different temperatures
Open Research DataIn this dataset are presented results of the polarization resistance of differently sintered SrTi0.65Fe0.35O3 porous oxygen electrodes in symetrical cell. Applied sintering temperatures were 900 °C, 950 °C and 1000 °C. The measurement temperature range was between 800 °C and 500 °C with synthetic air flow (21% O2, 40 ml min-1). Results converted to...
-
Area specific resistance (at 800 °C - 500 °C) of the SrTi0.30Fe0.70O3 porous oxygen electrodes at different oxygen partial pressures
Open Research DataIn this dataset are presented results of the polarization resistance of SrTi0.30Fe0.70O3 porous oxygen electrodes sintered at 800 °C. The measurement temperature range was between 800 °C and 500 °C. Applied different oxygen partial pressure flow was: 1%, 20% and 100% pO2. Results converted to electrode surfaces area and dived by two electrodes. All...
-
Deterioration of masonry structure investigated by a thermal camera with a qualitative assessment of thermal image processing
PublicationThermal imaging is contemporary remote sensing measurement technique, which provides an image of the temperature distribution in the measured object. The method is widely used, due to its mobility as well as the non-destructive character of the measurement. Infrared thermography is especially relevant in the inspection of insulation, what is more, it is a suitable device for detecting thermal bridges and structural changes, which...
-
The electrical conductivity of pristine, La-, and Nb-doped SFM measured in air and hydrogen atmospheres
Open Research DataThis dataset consists of an Excel sheet with the result of DC4W method of electrical measurements. The measurements were conducted on pristine strontium ferrite molubdate as well as ones doped with La and Nb. Additionally two samples co-doped with La and Ni/Co were analyzed. Pellets were prepared by high temperature sintering at 1400 deg. C, then cut...
-
ROSANNE Project: New Procedure for Noise Characterisation of Road Surfaces in Europe
PublicationROSANNE is a collaborative project in the 7th EU Framework Programme which aims at harmonising measurement methods for skid resistance, noise emission and rolling resistance of road pavements as a preparation for standardization. The project started in November 2013 and is developing and improving standards in the field of working group CEN/TC 227/WG 5. Regarding the influence of the pavement on the road traffic noise emission,...
-
Szacowanie estymaty menzurandu temperatury skóry człowieka podczas próby wysiłkowej
PublicationW artykule zaprezentowano wyniki pomiarów temperatury skóry człowieka podczas próby wysiłkowej. Ponieważ uzyskane wyniki nie podlegają rozkładowi normalnemu, wyznaczono wartości pięciu różnych estymatorów menzurandu. Otrzymane rezultaty wykazały, że w rozważanym przypadku najlepszy estymator menzurandu otrzymujemy z metody bootstrap, ponieważ charakteryzuje się on najmniejszym odchyleniem standardowym.
-
Dynamic state assessment of the water turbine with the power of 600 kW
PublicationThe article discusses the results of experimental studies to assess the dynamic state of the turbine set with the Kaplan turbine. The dynamic assessment was made on the basis of appropriate standards, based on the measurement results of selected parameters of vibration, which have been measured for several states of the machine load. In addition, we attempted to identify the causes of the increased vibration levels based on the...
-
Techniques of acquiring additional features of the responses of individual gas sensors
PublicationGas sensors usually exhibit lack of selectivity, require fre quent calibration, exhibit drift of the response and a lot of factors, such as humidity or ambient temperature, influen ce their performance. Different approaches can be used to overcome this shortcomings. Building arrays of different sensors and usage of pattern recognition methods to analyze responses of elements...
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublicationRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
Implant system for treatment of the orbital floor defects of blowout fractures in the maxillofacial region using polypropylene yarn and bioactive bone cement
PublicationFractures in the craniofacial region are a serious problem in terms of treatment. The most reasonable solution is the use of individual implants dedicated to a specific patient. The aim of this study was to develop the implant system specifically for treatment of the orbital floor defects of blowout fractures of maxillofacial region, using polypropylene yarn and bone cement. Three types of bone cement were used to fix the polypropylene...
-
Adoption of the F-statistic of Fisher-Snedecor distribution to analyze importance of impact of modifications of injector opening pressure of a compression ignition engine on specific enthalpy value of exhaust gas flow
PublicationThis article analyzes the effect of modifications of injector opening pressure on the operating values of a compression ignition engine, including the temperature of the fumes. A program of experimental investigation is described, considering the available test stand and measurement capabilities. The structure of the test stand on which the experimental measurements were conducted is presented. The method of introducing real modifications...
-
Determination of binder-aggregate adhesion by contact angle measurement
PublicationThe key factor in asphalt pavement durability, especially in the presence of water, is adhesion of the bituminous binder to mineral aggregates. There are currently no standard laboratory test procedures that can quickly and accurately measure the strength of the interaction (bond) between the binder and aggregate. In this regard, to evaluate the adhesion force measurements based on the contact angle between the binder and the aggregate...
-
Noise and Electro-Ultrasonic Spectroscopy of Conducting PolymerThick Films
PublicationThick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On the conducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting...
-
Water Solubilization Using Nonionic Surfactants from Renewable Sources in Microemulsion Systems
PublicationIn this study the effect of temperature, NaCl andoils (hydrocarbons: C8-C16) on the formation and solubilizationcapacity of the systems of oil/monoacylglycerols(MAG):ethoxylated fatty alcohols (CEO20)/propylene glycol(PG)/water was investigated. The effects of the surfactantmixture on the phase behavior and the concentration ofwater or oil in the systems were studied at three temperatures(50, 55, 60 C) and with varied NaCl solutions...
-
Ferromagnetism in Pr-rich binary Pr7Ru3 intermetallic compound
PublicationWe present the synthesis and experimental characterization of the binary intermetallic compound Pr7Ru3. The polycrystalline sample was prepared by arc melting pure Pr and Ru, followed by homogenization at 500 °C and 600 °C for 48 and 89 h, respectively. Powder x-ray diffraction confirms that Pr7Ru3 crystallizes in an orthorhombic crystal structure (Pnma, space group no. 62) with the lattice parameters: a = 7.3606(7) Å, b = 23.120(1)...
-
Experiments and numerical modeling of meat and bone meal pyrolysis in a rotary kiln
PublicationThe paper presents aspects of modelling the pyrolysis of meat and bone meal (MBM) in a rotary kiln. The pyrolysis of MBM produces a solid fraction which can be used as a fuel, a liquid fraction with potential chemical applications and a low heating value gas. The meat and bone meal pyrolysis was carried out at the temperature of 900 oC. Main features of experiments and numerical model of the pyrolysis were described. The model...
-
Comparisson of area specific resistance of the SrTi1-xFexO3-d porous oxygen electrodes and state-of-the-art LSCF sintered at optimal conditions
Open Research DataIn this dataset are presented results of the polarization resistance of optimaly sintered SrTi1-xFexO3-d porous oxygen electrodes in symetrical cell (1000 °C; 800 °C and 800°C respectively x = 0.35; 0.50 and 0.70). For commparison were selected commercially avilable state-of-the-art LSCF (Europa) sintered at 1050 °C. The measurement temperature range...