Search results for: capillary pumped loop
-
Experimental study of pressure rise at the evaporator of capillary pumped loop with acetone and water as working fluids
PublicationIn this work studied is the possibility of fluid pumping using capillary forces in the capillary pumped loop. Experimental and theoretical studies have been performed to understand the phenomena associated with heat transfer in porous structure of the evaporator. The capillary effect was studied during operation of two different capillary porous structures with two different working fluids, namely water and acetone. The results...
-
Capillary pumped loop as a tool for collecting large heat fluxes from electronic devices on warships
PublicationThe combat potential of future warships will be directly related to the use of modern electronic devices being parts of advanced systems, such as, for instance, radar systems, fire aiming systems, fire detection systems, electric drive systems, and even electronic and radio-electronic weaponry, railguns and lasers, installed on these warships. The capacity and functionality of these devices is continually increasing, at decreasing...
-
Investigation of the influence of capilary effect on operation of the loop heat pipe
PublicationIn the paper presented are studies on the inestigation of the capillary forces effect inducted in the porous structure of a loop heat pipe using water and ethanol ad test fluids. The potential application of such effects is for example in the evaporator of the domestic micro-CHP unit, where the reduction of pumping power could be obtained. Preliminary analysis of the results indicates water as having the best potential for developing...
-
The concept of capillary forces supported evaporator for application to domestic ORC unit
PublicationIn the paper presented are studies on the investigation of the capillary forces effect inducted in the porous structure of a loop heat pipe. The potential application of such heat exchanger is for example an evaporator of the domestic micro CHP unit. Preliminary analysis of the results indicates water as having the best potential, however taking into account all issues it can be said that the best effect is obtained using ethanol.
-
The Influence of Loop Heat Pipe Evaporator Porous Structure Parameters and Charge on Its Effectiveness for Ethanol and Water as Working Fluids
PublicationAbstract: This paper presents the results of experiments carried out on a specially designed experimental rig designed for the study of capillary pressure generated in the Loop Heat Pipe (LHP) evaporator. The commercially available porous structure made of sintered stainless steel constitutes the wick. Three different geometries of the porous wicks were tested, featuring the pore radius of 1, 3 and 7 um. Ethanol and water as two...
-
The new concept of capillary forces aided evaporator for application in domestic organic rankine cycle
PublicationThis paper presents studies on the possibility of applying capillary forces induced in the porous structure to a modern design of evaporator. The potential application of such heat exchanger is for example an evaporator of the domestic micro combined heat and power (CHP) unit. One of the problems in the micro-CHP is excessive demand for pumping power. The proposed design helps in overcoming that issue. In the evaporator outlined...
-
The loop impedance measurement
Open Research DataThe loop impedance measurement
-
Pumped-storage power plant Żarnowiec.
PublicationPrzedstawiono historię budowy, główne zadania i parametry techniczne elektrowni szczytowo-pompowej w Żarnowcu
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublicationThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Capillary Electrophoresis in Determination of Low Molecular Mass Organic Acids
PublicationThis paper presents overviews the capabilities of capillary electrophoretic techniques to determine low molecular mass organic acids in a variety of aqueous, gas and solid samples. It mainly focuses on short - chain carboxylic acids containing one or more carboxylic groups and possibly some other functional groups (hydroxyl, keto-, amino- etc.). Finally the procedures applied to the determine the acids in different matrices are...
-
Molecularly imprinted polymers applied in capillary electrochromatography and electrophoresis techniques
PublicationMolecularly imprinted polymers (MIPs) are synthetic materials with predetermined selectivity for a particular analyte or group of structure-linked chemicals which make them an ideal separation component. The process of developing and applying new types of MIPs in the field of environmental analytical chemistry has been broadly discussedi n many scientific studies in recent years. The use of new types of MIP sorbents as unique sorption...
-
Vibrational Quenching of Optically Pumped Carbon Dimer Anions
PublicationCareful control of quantum states is a gateway to research in many areas of science such as quantum information, quantum-controlled chemistry, and astrophysical processes. Precise optical control of molecular ions remains a challenge due to the scarcity of suitable level schemes, and direct laser cooling has not yet been achieved for either positive or negative molecular ions. Using a cryogenic wire trap, we show how the internal...
-
Power Hardware-in-the-Loop Approach In Power System Development
PublicationThe main objective of the research is the verification of the Power Hardware-In-The-Loop (PHIL) approach in power system analysis and design. The premise of the article is that using PHIL approach the performance of the power system in steady and transient state conditions can be analysed in real power system conditions. Models of induction machine were developed and real time simulations were performed. Simulation variables were...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Loop-mediated isothermal amplification (LAMP) as a diagnostic tool in detection of infectious diseases
PublicationLoop-mediated isothermal amplification (LAMP) is a gene amplification method which amplifies DNA with high specificity and efficiency under isothermal conditions. Because of its rapidity and simplicity, it is a valuable diagnostic tool in the early detection and identification of infectious diseases. LAMP method is based on the use of a set of four to six specially designed primers spanning six to eight distinct sequences on the...
-
Multidimensional capillary electrophoresis
Publication -
Closed-loop stimulation of temporal cortex rescues functional networks and improves memory
PublicationMemory failures are frustrating and often the result of ineffective encoding. One approach to improving memory outcomes is through direct modulation of brain activity with electrical stimulation. Previous efforts, however, have reported inconsistent effects when using open-loop stimulation and often target the hippocampus and medial temporal lobes. Here we use a closed-loop system to monitor and decode neural activity from direct...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Flow Boiling in Minigap in the Reversed Two-Phase Thermosiphon Loop
PublicationThe paper presents the results of experimental investigations of a model of a heat exchanger featuring a minigap, which is perceived as an evaporator for an inverted thermosiphon. The system works with a single component test fluid. The tested evaporator generates pumping power in the test loop in a way similar to the mammoth pump. The tests regarded a module of the heat exchanger, consisting of a hot leg and a cold leg with the...
-
Recent Advances in Loop Heat Pipes with Flat Evaporator
PublicationThe focus of this review is to present the current advances in Loop Heat Pipes (LHP) with flat evaporators, which address the current challenges to the wide implementation of the technology. A recent advance in LHP is the design of flat-shaped evaporators, which is better suited to the geometry of discretely mounted electronics components (microprocessors) and therefore negate the need for an additional transfer surface (saddle)...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Vibration surveillance supported by Hardware-In-the-Loop Simulation in milling flexible workpieces
PublicationW artykule przedstawiono nowoczesne podejście do problemu minimalizacji poziomu drgań podczas frezowania szybkościowego elementów podatnych. Do analizy dynamicznej procesu skrawania zastosowano niestacjonarny model opisany we współrzędnych hybrydowych. Na tej podstawie, przy wykorzystaniu energetycznego wskaźnika jakości wyprowadzono opis sygnału sterującego. Sygnał ten jest następnie stosowany do aktywnej redukcji drgań przedmiotu...
-
D-loop sequences retrieved from Canis lupus familiaris mitochondrial genome
Open Research DataCanine mitochondrial genome is built of 16727 bp. Non-coding control region (mtCR), called also D-loop, begins with 15458 nucleotide and ends with 16727 nucleotide. The length of this fragment is 1270 bp (Kim et al., 1998). D-loop region is responsible for replication and transcription of mitochondrial DNA. Mutations that occur within it may cause irregularity...
-
Capillary hemangioma - Female, 58 - Tissue image [6290730011499891]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: VS200 Olympus slide scanner (20x magnification) and saved to DICOM format.
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Influence of Pumped-Storage Power Plant on Physical and Ecological State of Lake Żarnowiec
PublicationOd 1983 roku istnieje elektrownia szczytowo-pompowa w Żarnowcu. Od 1973 roku do chwili obecnej prowadzono badania stanu ekologicznegi, chemicznego i fizicznego wód jeziora Żarnowieckiego. W artykule przedstawiono wyniki tych badań i na ich podstawie oceniono wpływ pracy elektrowni na stan jeziora.
-
A mobile loop order–disorder transition modulates the speed of chaperonin cycling
PublicationMolecular machines order and disorder polypeptides as they form and dissolve large intermolecular interfaces, but the biological significance of coupled ordering and binding has been established in few, if any, macromolecular systems. The ordering and binding of GroES co-chaperonin mobile loops accompany an ATP-dependent conformational change in the GroEL chaperonin that promotes client protein folding. Following ATP hydrolysis,...
-
Capillary Electrophoresis in determination of short - chain carboxylic acids in aqueous samples
PublicationAnalysis of pollution is extremely important especially in areas directly adjacent tothe residential district. Studies show that short- chain carboxylic acids are a group ofcompounds widespread around sewage treatment plants, landfills, livestock farms. The mostcommon techniques for determination of short - chain carboxylic acids are chromatographictechniques, especially gas chromatography, whose main limitation is that only volatilemonocarboxylic...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublicationA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Capillary hemangioma - Female, 35 - Tissue image [630073002825971]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Power Hardware-In-the-Loop Approach for Autonomous Power Generation System Analysis
PublicationThe article presents the Power Hardware-In-the-Loop (PHIL) dynamic model of a synchronous generator of 125 kVA for autonomous power generation system analysis. This type of system is typically composed of electrical energy sources in the form of several diesel generator units with synchronous machines, the main distribution switchboard and different loads. In modern power distribution systems, the proposed power management strategies...
-
Capillary hemangioma - Female, 41 - Tissue image [6200730021576261]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Male, 43 - Tissue image [619073001732461]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Male, 68 - Tissue image [6300730028264591]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Male, 43 - Tissue image [6190730017322071]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Male, 68 - Tissue image [6300730028269891]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current
PublicationThis paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed‐loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model‐based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved...
-
Capillary hemangioma - Male, 59 - Tissue image [6210729587594721]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Female, 32 - Tissue image [81307300030801]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Capillary hemangioma - Female, 56 - Tissue image [6210729587592421]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Isolation of Citrus lemon extracellular vesicles: Development and process control using capillary electrophoresis
PublicationA new and scalable method for the isolation of extracellular vesicles (EV) from Citrus lemon juice samples was developed. The methodology included preliminary preconcentration of the sample using ultrafiltration (UF) followed by size-exclusion chromatography (SEC) purification and final preconcentration of the eluates. Transmission electron microscopy and proteomic analysis showed that isolates contained exosome-like vesicles, exocyst-positive...
-
Capillary Polypropylene Membranes for Membrane Distillation
Publication -
Capillary hemangioma - Male, 64 - Tissue image [6210729587597051]
Open Research DataThis is the histopathological image of SKIN tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Current Trends in Wick Structure Construction in Loop Heat Pipes Applications: A Review
PublicationThermal control systems have been introduced as an important part of electronic devices, enabling thermal management of their electronic components. Loop heat pipe (LHP) is a passive two-phase heat transfer device with significant potential for numerous applications, such as aerospace applications, high-power LEDs, and solar central receivers. Its advantages are high heat transfer capability, low thermal resistance, long-distance...
-
A compartment model of alveolar–capillary oxygen diffusion with ventilation–perfusion gradient and dynamics of air transport through the respiratory tract
PublicationThis paper presents a model of alveolar–capillary oxygen diffusion with dynamics of air transport through the respiratory tract. For this purpose electrical model representing the respiratory tract mechanics and differentia equations representing oxygen membrane diffusion are combined. Relevant thermodynamic relations describing the mass of oxygen transported into the human body are proposed as the connection between these models,...
-
Modelling hydraulic and capillary-driven two-phase fluid flow in unsaturated concretes at the meso-scale with a unique coupled DEM-CFD technique
PublicationThe goal of the research was to demonstrate the impact of thin porous interfacial transition zones (ITZs) between aggregates and cement matrix on fluid flow in unsaturated concrete caused by hydraulic/capillary pressure. To demonstrate this impact, a novel coupled approach to simulate the two-phase (water and moist air) flow of hydraulically and capillary-driven fluid in unsaturated concrete was developed. By merging the discrete...
-
Augmented speed control scheme of dual induction motors with mutual flux angle control loop
PublicationThis paper proposes an augmented speed control scheme of dual induction motors fed by a five-leg voltage source inverter (VSI) with a common/shared-leg. An additional control loop is proposed here and based on the mutual flux angle – the difference between flux angular positions of the IMs. The main purpose of this research is to minimize the energy losses in the common inverter leg by controlling the mutual flux angle, at equal...
-
Miniaturized Dual-Band SIW-Based Bandpass Filters Using Open-Loop Ring Resonators
PublicationThis article presents two novel architectures of dual-band substrate integrated waveguide (SIW) bandpass filters (BPFs). Initially, two identical open-loop ring resonators (OLRRs) are coupled face-to-face on the top of the SIW cavity to realize a dual-band single-pole BPF. To obtain two-pole dual-band characteristics, two OLRRs resonant units are assembled horizontally within the top metal layer of the SIW, which is a technique...
-
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublicationThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
The impackt of polish pumped-storage plants on operation of the national power system on working days and holidays
PublicationPrzedstawiono wpływ polskich elektrowni szczytowo-pompowych na pracę krajowego systemu elektroenergetycznego w cyklu dobowym na przykładzie dni charakterystycznych roboczych i dni wolnych od pracy. Analizę przeprowadzono w oparciu o obliczenia wykonane w dwóch wariantach: system pracuje z istniejącymi elektrowniami pompowymi i system pracuje bez elektrowni pompowych.
-
Mechanical-Level Hardware-In-The-Loop and Simulation in Validation Testing of Prototype Tower Crane Drives
PublicationIn this paper, the static and dynamic simulations, and mechanical-level Hardware-In-the-Loop (MHIL) laboratory testing methodology of prototype drive systems with energy-saving permanent-magnet electric motors, intended for use in modern construction cranes is proposed and described. This research was aimed at designing and constructing a new type of tower crane by Krupiński Cranes Company. The described research stage was necessary...
-
<title>Applications of capillary optical fibers</title>
Publication -
Geometry design in rerfractive capillary optical fibers
Publication -
Characterization of porous materials by capillary rise method
PublicationBadane były kinetyki penetracji ciał porowatych złożonych z cząstek o różnych wymiarach. Na podstawie przeprowadzonych badań okazało się, że kinetyki penetracji i ważność prawa Washburna zależą nie tylko od wielkości cząstek ale także od dystrybucji wielkości porów. Różnica w czasie jaka wynika z przepływu cieczy przez ośrodek porowaty do całkowitego nasycenia cieczą została zaproponowana jako nowy parametr, opisujący rozkład wielkości...
-
Importance of time evaluation in capillary rise method
PublicationBadano zwilżalność układu porowatego przez wodę i węglowodany, mierząc zmianę masy rurki wypełnionej szklanymi kulkami. Wskazano na różny czas i szybkość penetracji cieczy przez złoże.
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Common methods for the chiral determination of amphetamine and related compounds II: Capillary electrophoresis and nuclear magnetic resonance
PublicationAmphetamine group and related ring-substituted substances are generally synthetic compounds, belonging to one of the most heavily abused drug groups in recent years. Some compounds in this class also originate from plants. Analysis of the enantiomers of AM-type compounds and metabolites is extremely important for a number of scientific disciplines. From studies of biological activity or mechanisms through determination of precursor...
-
Challenges in operating and testing loop heat pipes in 500–700 K temperature ranges
PublicationThe potential applications of loop heat pipes (LHPs) are the nuclear power space systems, fuel cell thermal management systems, waste heat recovery systems, medium temperature electronic systems, medium temperature military systems, among others. Such applications usually operate in temperature ranges between 500–700 K, hence it is necessary to develop an LHP system that will meet this requirement. Such a thermal management device...
-
An oscillation-based built-in test scheme with AGC loop.
PublicationPrzedstawiono oscylacyjny tester wbudowany (OBIT) do testowania części analogowej elektronicznego układu mieszanego sygnałowo zmontowanego na pakiecie. W celu zwiększenia współczynnika pokrycia uszkodzeń, w testerze zastosowano pomiary w dziedzinie czasu i częstotliwości. Omówiono wybrane aspekty implementacji testera, w szczególności problem transformacji układu testowanego w oscylator. Przeprowadzono analizę stanu ustalonego...
-
Hardware-in-the-loop simulation of the synchronization process of power generators
PublicationPrzedstawiono nowoczesne urządzenia do badań synchronizatorów automatycznych w warunkach laboratoryjnych. Szczególną uwagę poświęcono systemowi wizualizacji tych urządzeń )przy ich pomocymożliwa jest ciągła kontrola, sterowanie i wizualizacja procesem synchronizacji w systemie elektroenergetycznym.
-
Influence of control loop on torsional vibrations of rotating machinery.
PublicationRozpatrywano wpływ pętli regulacyjnej silnika diesla na dynamikę układu napędowego okrętowego. Porównano obliczenia numeryczne z badaniami eksperymentalnymi. Stwierdzono duży wpływ pętli regulacyjnej silnika diesla na dynamikę układu. W obliczeniach numerycznych skoncentrowano się na drganiach skrętnych układu napędowego okrętowego. Analizowano wpływ sztywności skrętnej sprzęgła elastycznego na amplitudy momentów skrętnych...
-
Quality Control of Bacterial Extracellular Vesicles with Total Protein Content Assay, Nanoparticles Tracking Analysis, and Capillary Electrophoresis
PublicationExtracellular vesicles (EVs) were isolated from Pectobacterium zantedeschiae culturing media using direct ultracentrifugation (UC), iodixanol cushion ultracentrifugation (ICUC), and iodixanol density gradient ultracentrifugation (IDGUC) techniques. The isolates were characterized with total protein content assay (bicinchoninic acid assay, BCA), nanoparticles tracking analysis (NTA), and capillary electrophoresis (CE). A satisfactory...
-
Investigations of a membrane distillation pilot plant with a capillary module
Publication -
Modal structure design in refractive capillary optical fibers
Publication -
Two classes of capillary optical fibers: refractive and photonic
Publication -
Different detection and stacking techniques in capillary electrophoresis for metabolomics
Publication -
Size and mass minimization of capacitor bank in a power converter DC line of DC drive with closed loop control system with PWM and current limitation
PublicationPaper deals with evaluation equations for power filter of AC-DC power converter which allows to provide size and mass minimization of capacitor bank in DC drive closed loop systems with PWM and current limitation. Reliability of provided equations is proved by simulation in MATLAB/Simulink
-
Large scale complementary solar and wind energy sources coupled with pumped-storage hydroelectricity for Lower Silesia (Poland)
Publication -
A closed loop thermosyphon with conventional or minichannel based condenser and evaporator
PublicationPrzedstawiono uogólniony model termosyfonu, który może być rozpatrywany dla szeregu wariantów.Model opiera się na jednowymiarowych równanich masy, pędu i energii. Rozpatrzono dwa przypadki termosyfonu, tj. grzanie strony pionowej i chłodzenie strony pionowej oraz drugi, gdzie termosyfon jest ogrzewany na stronie pionowej a chłodzony na poziomej.
-
Mitochondrial D-loop informative SNPs in identification of dog’s breed
Publication -
Hydrodynamic studies in magnetically assisted external-loop airlift reactor
Publication -
Hardware-in-the-Loop Simutation of the Synchronization Process of Electric Power Units.
PublicationPrzedstawiono nowoczesne urządzenia do badań synchronizatorów automatycznych w warunkach laboratoryjnych. Szczególną uwagę poświęcono systemowi wizualizacji tych urządzeń )przy ich pomocymożliwa jest ciągła kontrola, sterowanie i wizualizacja procesem synchronizacji w systemie elektroenergetycznym.
-
Closed-Loop Control System Design for Wireless Charging of Low-Voltage EV Batteries with Time-Delay Constraints
PublicationThis paper presents an inductive power transfer system on the basis of a double single- phase three-level T-type inverter and two split transmitting coils for constant current and constant voltage wireless charging of low-voltage light electric vehicle batteries with closed-loop control, considering time-delay communication constraints. An optimal control structure and a modified control strategy were chosen and implemented to...
-
The Application of Open Capillary Modules for Sweeping Gas Membrane Distillation
Publication -
Wettability Studies of Capillary PTFE Membranes Applied for Membrane Distillation
Publication -
Wettability of polypropylene capillary membranes during the membrane distillation process
Publication -
Drainage and capillary rise components in water balance of alluvial soils
PublicationPrzepływ wody przez dolny brzeg profilu glebowego stanowi ważny element wielu modeli pracy drenażu. Przeciekanie wody w głąb albo podsiąk kapilarny ku górze mierzone były metodą lizymetryczną w warunkach polowych podczas 4 lat (1972-1975). Podsiąk kapilarny wynosił 40-50% ogólnego zasilania w wodę w glebach typu Histosols, natomiast prawie zero w glebach typu Inceptisols. Pomierzone wartości pozwalaja na ocenę wymiany wody pomiedzy...
-
Capillary electrophoretic separation of cationic constituents of imidazolium ionic liquids
Publication -
Multiple output differential OTA with linearizing bulk-driven active-error feedback loop for continuous-time filter applications
PublicationA CMOS circuit realization of a highly linear multiple-output differential operational transconductance amplifier (OTA) has been proposed. The presented approach exploits a differential pair as an input stage with both the gate and the bulk terminals as signal ports. For the proposed OTA, improved linearity is obtained by means of the active-error feedback loop operating at the bulk terminals of the input stage. SPICE simulations...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublicationThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
EMBOA - affective loop in Socially Assistive Robotics as an intervention tool for children with autism
e-Learning CoursesThe aim of the training course "Intensive programmes for higher education learner" within the EMBOA project is to familiarise participants with the use of social robots as an intervention tool for children with autism, emotion recognition and the combination of both methods. Students will be informed about the guidelines and results of the project.
-
Compact-planar monopole loop antennas for 802.11b/g WLAN systems
PublicationZaproponowano planarne anteny monopolowe dla systemów komunikacji bezprzewodowej WLAN pracujących w pasmach 2.45GHz i 5.25GHz. W strukturze radiatorów zasilanych poprzez linię mikropaskową wykorzystano krzywe fraktalne: pętlę Kocha oraz pętlę Minkowskiego. W obu przypadkach uzyskano dwuzakresową pracę anten dzięki wprowadzeniu nowej konfiguracji zminiaturyzowanych transformatorów impedancji w układzie zasilania.
-
The concept of capillary forces supported evaporator for application to domestic ORC unit
PublicationW pracy przedstawiono koncepcję parownika wspomaganego siłami kapilarnymi do wykorzystania w mikrosiłowni domowej.
-
Application of Capillary Polypropylene Membranes for Microfiltration of Oily Wastewaters: Experiments and Modeling
Publication -
<title>Atom guiding in single mode optical fiber capillary</title>
Publication -
Determination of acetaldehyde and acrolein in raw spirits by capillary isotachophoresis after derivatization
PublicationW publikacji opisano optymalizację i przygotowanie nowej procedury oznaczania acetaldehydu i akroleiny w spirytusach surowych z wykorzystaniem techniki izotachoforezy kapilarnej (ITP). Aldehydy - związki niejonowe poddawane są derywatyzacji wodorosiarczynem sodu. Zaprezentowana metoda analityczna charakteryzuje się granicą oznaczalności na poziomie 0,03 ul/cm3 100% EtOH dla akroleiny oraz 0,54 ul/cm3 100% EtOH dla acetaldehydu....
-
Analysis of different approaches of capillary rise method for characterization of porous materials
PublicationPomiar kąta zwilżania materiałów porowatych metodą wzniesienia kapilarnego został opisany przez wielu badaczy, jakkolwiek problem ten jest wciąż dyskutowany. Niniejsza praca dotyczy oceny wzniesienia kapilarnego za pomocą równania Washburn'a. Wykonano badania oparte na pomiarze masy i wysokości lustra cieczy zwilżającej w funkcji czasu wzniesienia w złożu wykonanym z kulek szklanych. Uzyskane wyniki były analizowane z użyciem równania...
-
Modeling of capillary fluid flow in concrete using a DEM-CFD approach
PublicationSformułowano połączone podejście do modelowania dwufazowego przepływu wody napędzanego hydraulicznie i kapilarnie w nienasyconym betonie. Proces przepływu analizowano numerycznie w mezoskali w warunkach dwuwymiarowych (2D), łącząc metodę elementów dyskretnych (DEM) z obliczeniową dynamiką płynów (CFD) w warunkach izotermicznych. Przeprowadzono w pełni sprzężone hydromechaniczne testy symulacyjne na małych próbkach betonu o uproszczonej...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublicationW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Programowo-sprzętowa platforma symulacyjna - Hardware In the Loop - zaawansowanego układu sterowania poziomem wody w pionowej wytwornicy pary elektrowni jądrowej
PublicationW artykule przedstawiono koncepcję programowo-sprzętowej platformy symulacyjnej wykorzystującej technikę symulacji w pętli sprzętowej HIL (ang. Hardware In The Loop simulation), wykorzystanej dla potrzeb projektowania i weryfikacji w czasie rzeczywistym (ang. Real Time) zaawansowanych algorytmów sterowania poziomem wody w pionowej wytwornicy pary elektrowni jądrowej. Jej głównymi elementami są: środowisko czasu rzeczywistego Matlab/Simulink...
-
Programowo-sprzętowa platforma symulacyjna - Hardware In the Loop - zaawansowanego układu sterowania poziomem wody w pionowej wytwornicy pary elektrowni jądrowej
PublicationW artykule przedstawiono koncepcję programowo-sprzętowej platformy symulacyjnej wykorzystującej technikę symulacji w pętli sprzętowej HIL (ang. Hardware In The Loop simulation), wykorzystanej dla potrzeb projektowania i weryfikacji w czasie rzeczywistym (ang. Real Time) zaawansowanych algorytmów sterowania poziomem wody w pionowej wytwornicy pary elektrowni jądrowej. Jej głównymi elementami sa: środowisko czasu rzeczywistego Matlab/Simulink...
-
Profiling of polar ionogenic metabolites in Polish wines by capillary electrophoresis-mass spectrometry
PublicationThe composition of wine is determined by a complex interaction between environmental factors, genetic factors (i.e., grape varieties), and winemaking practices (including technology and storage). Metabolomics using NMR spec-troscopy, GC-MS, and/or LC-MS has shown to be a useful approach for assessing the origin, authenticity, and quality of various wines. Nonetheless, the use of additional analytical techniques with complementary...
-
The new concept of capillary forces driven evaporator with application to waste heat recovery
PublicationW pracy omówiono koncepcję zastosowania rurki ciepła w nowoczesnej konstrukcji parownika wspomagającego za pomocą sił kapilarnych pompę obiegu termodynamicznego czynnika. Rozwiązanie takie może znaleźć zastosowanie w domowej mikrosiłowni CHP
-
Influence of morphology of PVDF capillary membranes on the performance of direct contact membrane distillation
Publication -
Determination of Urinary Pterins by Capillary Electrophoresis Coupled with LED-Induced Fluorescence Detector
Publication -
Using different types of capillary columns as denudation traps: a comparision of sorption properties
PublicationOpisano badania odcinków kapilarnych kolumn chromatograficznych (WCOT, SCOT,PLOT) jako pułapek denudacyjnych do ilościowego zatrzymywania śladowych ilości lotnych związków organicznych ze strumienia powietrza. W trakcie badań modelowych (z wykorzystaniem gazowych mieszanin wzorcowych) określono wartości współczynników podziału benzenu, toluenu, etylobenzenu, o-ksylenu i chlorobenzenu (Kfs). Stwierdzono, że grubość filmu fazy stacjonarnej...
-
Power Hardware In-the-Loop validation of DC-DC power converter for offshore wind energy
Publication -
The role of the LB structural loop and its interactions with the PDZ domain of the human HtrA3 protease
Publication