Filters
total: 2931
-
Catalog
- Publications 2527 available results
- Journals 28 available results
- People 62 available results
- Inventions 1 available results
- Projects 8 available results
- Laboratories 1 available results
- Research Teams 1 available results
- e-Learning Courses 38 available results
- Events 6 available results
- Open Research Data 259 available results
displaying 1000 best results Help
Search results for: COMPETENCE GAPS
-
Noise measurement setups for fluctuations enhanced gas sensing
PublicationObserwacje zjawisk fluktuacyjnych w sensorach gazów pozwala zwiększyć czułość i selektywność detekcji gazów. Problemem jest budowa prostego i taniego systemu do obserwacji tych zjawisk. W artykule przedstawiono dwa systemy pozwalające na obserwacje szumów w rezystancyjnych sensorach gazów dostępnych na rynku i prototypowych, wykonanych z warstwy nanocząstek o zbliżonych wymiarach.
-
Analogowy regenerator sygnałów systemu nawigacji satelitarnej GPS
PublicationW niniejszym artykule poruszono problem braku możliwości odbioru sygnałów systemu GPS w pomieszczeniach zamkniętych. Opisano środki służące rozwiązaniu tego problemu, w postaci regeneratorów sygnałowych. Przedstawiono rodzaje oraz wybrane zastosowania takich regeneratorów. Zaprezentowano opracowaną realizację analogowego regeneratora sygnałów GPS. Następnie opisano stanowisko pomiarowe oraz metodykę pomiarów wybranych parametrów...
-
Analytical fluctuation enhanced sensing by resistive gas sensors
PublicationResistance fluctuations across polarised resistive gas sensors were studied in detail to evaluate sensor working conditions for detecting methane and ammonia at various concentrations. The 1/f noise component typically dominates other noise sources up to a few kHz and can be utilised to improve gas selectivity when compared with measurements of the sensor DC resistance. The Arrhenius plot was created and the activation energy for...
-
Resistive gas sensors – Perspectives on selectivity and sensitivity improvement
PublicationResistive gas sensors are very popular and relatively inexpensive; they can operate at elevated or room temperature for years on end. The main disadvantage of resistive gas sensors is their limited selectivity and sensitivity, but various methods have been applied to improve their behavior. The composition of the porous gas sensing layer, or changes in the sensor’s operating temperature, can enhance the gas detection ability. Furthermore, emerging...
-
A system of visualization of operational situation on digital maps for mobile units of the Border Guards
PublicationBorder guards have to be equipped with technology enabling a communication, an acquisition, an exchange, and a visualization of data in different operational situations. This also applies to the staff, which is located on mobile units such as ground vehicles, aircrafts and vessels. Within the project realized for the Polish Border Guard and financed by The National Centre for Research and Development, a system was designed and...
-
Standard of living in Poland at regional level - classification with Kohonen self-organizing maps
PublicationThe standard of living is spatially diversified and its analyzes enable shaping regional policy. Therefore, it is crucial to assess the standard of living and to classify regions due to their standard of living, based on a wide set of determinants. The most common research methods are those based on composite indicators, however, they are not ideal. Among the current critiques moved to the use of composite...
-
The exponential law for partial, local and proper maps and its application to otopy theory
Publication -
Minimizing the number of periodic points for smooth maps. Non-simply connected case
PublicationNiech f będzie gładkim odwzorowaniem zamkniętej rozmaitości o wymiarze wiekszym niż 2, a r ustaloną liczbą naturalną. W artykule zdefiniowany został niezmiennik topologiczny równy minimalnej liczbie punktów r-periodycznych w gładkiej klasie homotopii f.
-
The history of Lake Rzecin and its surroundings drawn on maps as a background to palaeoecological reconstruction
Publication -
Assessment of the water quality of Kłodnica River catchment using self-organizing maps
PublicationRisk assessment of industrial areas heavily polluted due to anthropogenic actions is of increasing concern worldwide. So is the case of Polish Silesia region where mostly heavy industry like smelters, mining, chemical industries as well as heat and electricity production facilities are being located. Such situation raises numerous questions about environmental state of local water bodies with special attention paid to the Kłodnica...
-
A Comparison of Ammonia Emission Factors from Light-Duty Vehicles Operating on Gasoline, Liquefied Petroleum Gas (LPG) and Compressed Natural Gas (CNG)
Publication -
Bridging the gap between architectural and environmental engineering education in the context of climate change
PublicationIndicated in this article is the urgent need to adjust architectural education to the challenges triggered by climate change. Although reports on the future scenarios for cities are alarming, documents that set criteria for architectural education do not indicate competencies related to climate change adaptation and mitigation, mainly by avoiding environmental engineering considerations. An immediate answer to this problem could...
-
Justyna Płotka-Wasylka dr hab. inż.
PeopleUrodziła się w Słupsku (24.03.1986).W 2005 roku ukończyła I Liceum Ogólnokształcące im. Jana II Sobieskiego w Wejherowie i rozpoczęła studia na Wydziale Chemicznym Politechniki Gdańskiej. Po ich ukończeniu w 2010 rozpoczęła pracę naukową na tej uczelni, uzyskując w 2014 roku stopień doktora nauk chemicznych. Tematem jej rozprawy doktorskiej, wykonywanej pod kierunkiem prof. Marka Biziuka oraz dr Caluma Morrisona (Uniwersytet w...
-
Journal of Natural Gas Science and Engineering
Journals -
Investigation of the temperature modulation parameters on semiconductor gas sensor response
PublicationIn this work we present the results of the investigation of the sensing properties of semiconductor gas sensors with a sinusoidally modulated temperature in the presence of synthetic air (SA) and three volatile air pollutants, i.e. NH3, NO2 and SO2. The measurements were performed for different average sensor heater temperatures and the amplitude of the modulation signal. In addition, the extraction of features from the sensor...
-
Ammonia Gas Sensors: Comparison of Solid-State and Optical Methods
PublicationHigh precision and fast measurement of gas concentrations is important for both understanding and monitoring various phenomena, from industrial and environmental to medical and scientific applications. This article deals with the recent progress in ammonia detection using in-situ solid-state and optical methods. Due to the continuous progress in material engineering and optoelectronic technologies, these methods are among the most...
-
Monitorowanie regionalnych zmian jonosfery z godzinnych obserwacji GPS
PublicationW nowoczesnych metodach przestrzennego wyznaczania pozycji główną rolę odgrywają globalne systemy satelitarne, pozwalające na wyznaczenie pozycji obiektu niezależnie od czasu i położenia, w najbliższym sąsiedztwie Ziemi. Obecnie znanych jest kilka satelitarnych systemów pozycjonowania o zasięgu globalnym. Wśród nich wymienić należy: GPS, GLONASS, DORIS, PRARE, w niedalekiej przyszłości - GALILEO. Wykorzystanie poszczególnych systemów,...
-
Two-dimensional gas chromatography – principles and application in fruits analysis
PublicationTwo-dimensional gas chromatography is a rapidly developing analytical technique. One of the major uses of this technique is its use for food analysis. The paper presents the principle of operation and history of this analytical technique. The specification of the two-dimensional gas chromatography technique has been discussed. The principles of separation of ingredients and application of the method, particularly in the analysis...
-
Ionospheric scintillations computation using real-time GPS observations
PublicationThe following paper presents the results of quasi-real-time determination of the values of phase scintillations indices at the period of ionospheric disturbances that occurred as a consequence of the Sun flares observed on March 7 and 9, 2012. Double-frequency observations with 1-second measurement interval from the EPN (EUREF Permanent Network) network sites located at high latitudes were used for the analysis. To determine the phase...
-
GPS-derived height changes in diurnal and sub-diurnal timescales
PublicationThis paper describes the research concerning precise short-time GPS solutions conducted in the Centre of Applied Geomatics, Military University of Technology, Warsaw, Poland. The data from ASG-EUPOS (Polish Active Geodetic Network) was processed using Bernese 5.0 software and EPN (EUREF Permanent Network) standards and models. In this study, the adapted 3-hour observation window is shifted every hour for obtaining hourly geocentric...
-
Nonlinear phenomena of small-scale sound in a gas with exponential stratification
PublicationThe nonlinear dynamics of perturbations, quickly varying in space, with comparatively large characteristic wavenumbers k: k>1/H, is considered. H is the scale of density and pressure reduction in unperturbed gas, as the coordinate (H is the so-called height of the uniform equilibrium gas). Coupling nonlinear equations which govern the sound and the entropy mode in a weakly nonlinear flow are derived. They describe the dynamics...
-
Low-energy positron scattering from gas-phase benzene
PublicationIn this paper we are presenting calculations of the elastic cross section of positrons with gas-phase benzene for the energy range from 0.25 eV to 9.0 eV. The calculations are done with the molecular R-matrix method for positron-scattering from poly-atomic molecules using a scaling factor to scale the electron-positron interaction. The scaling factor influences the position of the poles of the R-matrix. We adjust the scaling factor...
-
Inspection of rubber linings operating in flue gas desulphurisation units
Publication -
Methods of preparation and performance of sealed gas photomultipliers for visible light
Publication -
Analysis and interpretation of radiometric signals in a liquid-gas bubble flow
PublicationThe article presents the analysis of signals from a radiometric system consisting of two scintillation probes and two gamma radiation sealed sources. Calculations and interpretation were carried out for the bubble flow of the water-air mixture in the horizontal pipeline. The analysis of the obtained signals was done in time and frequency domain. In the frequency domain, a range of usable frequencies was identified, which were associated...
-
Spinning Fluids Reactor: A new design of a gas – liquid contactor
PublicationCurrent trends in chemical reactor design are based on adapting these to the requirements of a particular chemical process. Processes involving reactions between the gas and liquid phase in particular require precise adjustment of all parameters. The common denominator for most modern design solutions is enhancement of the mass transfer area and the overall volumetric mass transfer coefficient. Gas – liquid contactors evolved from...
-
Experimental investigation of domestic gas boiler fitted with ORC module
PublicationIn the paper the prototype of innovative domestic cogenerative ORC system, consisting of a conventional gas boiler and a small size axial vapour microturbines (in-house designed for ORC and the commercially available for Rankine cycle (RC)), evaporator and condenser were scrutinised. In the course of study the fluid working temperatures, rates of heat, electricity generation and efficiency of the whole system were obtained. The...
-
Classification of Polish wines by application of ultra-fast gas chromatography
PublicationThe potential of ultra-fast gas chromatography (GC) combined with chemometric analysis for classification of wine originating from Poland according to the variety of grape used for production was investigated. A total of 44 Polish wine samples differing in the type of grape (and grape growth region) used for the production as well as parameters of the fermentation process, alcohol content, sweetness, and others which characterize...
-
Wavelet Transform Analysis of Temperature Modulated Gas Sensor Response
PublicationThe aim of the study was to evaluate whether it is possible to extract the information about the gas concentration despite the influence of humidity. Commercial semiconductor sensor response was examined under the application of a periodic temperature change. The data was collected using measurement protocol for different concentrations of ammonia at specified levels of relative humidity. In this work we focused on the evaluation...
-
Chemometric analysis for optimizing derivatization in gas chromatography-based procedures
Publication -
Charge Loss in Gas-Phase Multiply Negatively Charged Oligonucleotides
Publication -
On a Certain Research Gap in Big Data Mining for Customer Insights
Publication -
The Application of Open Capillary Modules for Sweeping Gas Membrane Distillation
Publication -
Irregular variations in GPS time series by probability and noise analysis
Publication -
charakterystyki sygnału w realizacji software'owego odbiornika systemu GPS
PublicationRealizacja odbiornika w postaci aplikacji komputerowej pozwala nie tylko na kilkukrotne obniżenie kosztów jego produkcji, ale również wykorzystanie procesora ogólnego przeznaczenia do zadań związanych z odbiorem sygnału GPS i określaniem pozycji, a tym samym uproszczenie systemu. Analiza procesu przetwarzania sygnału GPS z wykorzystaniem standardowych narzędzi kompilacji i debugging'u, pozwala na poznanie działania odbiornika GPS...
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationWykrywanie zapachów podczas aromaterapii może być przeprowadzone za pomocą pojedynczego sensora gazów. W pracy rozważono efektywność detekcji zapachów olejków eterycznych za pomocą rezystancji DC oraz zjawisk fluktuacyjnych w tych sensorach, typu TGS2600,TGS2602,TGS823. Badania koncentrowały się na praktycznym zastosowaniu w aromaterapii do określania intensywności emitowanego zapachu. Opisano szczegółowo system do emisji zapachów.
-
Sensitivity to nitrogen dioxide of electrocatalytic gas sensor based on NASICON
PublicationW pracy przedstawiono wyniki badań czujnika elektrokatalitycznego na bazie NASICONu.
-
Chiral gas chromatography as a tool for investigation into illicitly manufactured methamphetamine
PublicationW pracy przedstawiono zastosowanie gazowej chromatografii chiralnej do rozdzielania związków ubocznych powstających w trakcie syntezy metylamfetaminy. Opisano rozdzielanie enancjomerów efedryny, pseudoefedryny, chlorowanych związków posrednich i metylamfetaminy stosując do derywatyzacji bezwodniki fluorowanych kwasów. Jako fazę chiralną zastosowano CHIRALDEX B-DM. Do rozdzielenia enancjomerów pseudoefedryny oraz chlorowanych produktów...
-
Wetting of supports by ionic liquids used in gas separation processes
PublicationCiecze jonowe są stosowane w procesach separacji gazów jako selektywne rozpuszczalniki. Są szeroko stosowane w technologii immobilizowanych membran ciekłych, głównie w procesach oczyszczania strumieni gazowych. Praca ta charakteryzuje komercyjnie dostępne membrany porowate używane we wspomnianych procesach. Określenie właściwości nośników i fazy membranowej ma na celu wyznaczenie czynników mających wpływ na stabilności takich układów...
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationScent or aroma sensing during aromatherapy can be carried out by applying only a single resistance gas sensor (TGS - Taguchi Gas Sensors). This paper considers the efficiency of detection of essential oils by DC resistance and its fluctuations observed in TGS sensors. A detailed study has been conducted for scents emitted by five popular essential oils using three sensor types (TGS 2600, TGS 2602, TGS 823). The research was focused...
-
Analysis of diagnostic informativeness of the exhaust temperature of a naval gas turbine
PublicationThe conducted investigations aimed to carry out an analysis of the possibility that the failures identification in the automatic control system of a gas turbine engine could be worked out on the basis of measurements of the exhaust stream temperature behind the gas generator. The exhaust temperature represents a basic control parameter, enabling technical state evaluation of the engine within the operation process, which is observed...
-
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublicationSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
The influence of electrocatalytic toxic gas sensor construction on its performance
PublicationW pracy przedstawiono porównanie właściwości elektrokatalitycznych czujników gazów przygotowanych na bazie różnych elektrolitów stałych oraz wykonanych w różnych technologiach.
-
Gas sensing by thermoelectric voltage fluctuations in SnO2 nanoparticle films
PublicationPrzedstawiono eksperymentalne wyniki wykrywania gazów za pomocą badania fluktuacji napięcia termoelektrycznego w warstwie SnO2 przygotowanej z jednorodnych ziaren o średnicy 20 nm. Obserwowano fluktuacje napięcia bez zewnętrznej polaryzacji warstwy SnO2. Intensywność obserwowanych fluktuacji przekraczała 1000-krotnie intensywność szumów termicznych. Obserwowane zjawisko może byc wykorzystane do zwiększenia czułości wykrywania...
-
Resistance Noise Higher-Order Spectrums in Nanoparticle Gas Sensors.
PublicationPrzedstawiono badania fluktuacji rezystancji sensora gazu wykonanego z nanocząstek WO3. Stwierdzono występowanie składowych o rozkładzie prawdopodobieństwa różnym od rozkładu Gaussa. W celu zwiększenia czułości i selektywności wykrywanych gazów zastosowan do analizy obserwowanych fluktuacji spektra wyższych rzędów.
-
Gas turbine as ship prime mover - specific problems and prospects.
PublicationPrzedstawiono ewentualne możliwości zastosowania turbin gazowych w okrętownictwie. Analizowano aspekty ekologiczne, ekonomiczne i techniczne.
-
Bridging the Gap Between Legitimacy and Neutralisation Strategies in Sustainability Reporting
PublicationAmid global sustainability challenges, such as climate change, companies operating in different industries face increasing demands for accountability and transparency. To meet these demands, sustainability reporting (SR) has become a mainstream business practice in communicating companies’ positive and negative sustainability impacts. This short paper aims to increase our understanding of how companies may release negative information...
-
Selected concentration techniques for gas chromatographic analysis of environmental samples
PublicationThe paper describes the role and tasks of environmental analysis and monitoring. It emphasises the leading role played by gas chromatography, especially when coupled with suitable sample preparation. This is demonstrated by some literature evidence and mainly by the author's original work on the design of sample preparation apparatus and development of GC-based methods of determination of a wide variety of organic pollutants in...
-
Technical and Economic Analysis of the Supercritical Combined Gas-Steam Cycle
PublicationCombined cycle power plants are characterized by high efficiency, now exceeding 60%. The record-breaking power plant listed in the Guinness Book of World Records is the Nishi-Nagoya power plant commissioned in March 2018, located in Japan, and reaching the gross efficiency of 63.08%. Research and development centers, energy companies, and scientific institutions are taking various actions to increase this efficiency. Both the gas...
-
Development of Gas Sensor Array for Methane Reforming Process Monitoring
PublicationThe article presents a new method of monitoring and assessing the course of the dry methane reforming process with the use of a gas sensor array. Nine commercially available TGS chemical gas sensors were used to construct the array (seven metal oxide sensors and two electrochemical ones). Principal Component Regression (PCR) was used as a calibration method. The developed PCR models were used to determine the quantitative parameters...