Filtry
wszystkich: 1426
wybranych: 811
-
Katalog
- Publikacje 811 wyników po odfiltrowaniu
- Czasopisma 35 wyników po odfiltrowaniu
- Konferencje 4 wyników po odfiltrowaniu
- Osoby 12 wyników po odfiltrowaniu
- Wynalazki 4 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Kursy Online 18 wyników po odfiltrowaniu
- Dane Badawcze 541 wyników po odfiltrowaniu
Filtry wybranego katalogu
Wyniki wyszukiwania dla: BONE-IMPLANT INTERFACE
-
STEADY STATE VISUALLY EVOKED POTENTIALS FOR BRAIN COMPUTER INTERFACE
PublikacjaAn experiment conducted to validate a possibility of use a single active electrode EEG device for detecting Steady State Visually Evoked Potentials (SSVEP) is shown. A LED stimulator was applied to stimulate patients with two different frequencies - 13 Hz and 17 Hz. First, EEG signals were recorded and pre-processed using MATLAB software. In the next step recordings were analysed and classified employing the WEKA software. As indicated...
-
Influence of Different Nanometals Implemented in PMMA Bone Cement on Biological and Mechanical Properties
PublikacjaCemented arthroplasty is a common process to fix prostheses when a patient becomes older and his/her bone quality deteriorates. The applied cements are biocompatible, can transfer loads, and dampen vibrations, but do not provide antibacterial protection. The present work is aimed at the development of cement with antibacterial effectivity achieved with the implementation of nanoparticles of different metals. The powders of Ag,...
-
Shaft friction from the DMT and direct shear interface tests
PublikacjaThe article presents preliminary attempt to create tri-linear transfer curves for describing pile behaviour under axial loading. Transfer curves would use the parameter measured in dilatometer test, particularly a constrained modulus MDMT. The proposed method is based on concrete rough and smooth interface tests performed in a direct shear apparatus. Based on the obtained mobilization curves, relationships were created between...
-
Uniform Model Interface for Assurance Case Integration with System Models
PublikacjaAssurance cases are developed and maintained in parallel with corresponding system models and therefore need to reference each other. Managing the correctness and consistency of interrelated safety argument and system models is essential for system dependability and is a nontrivial task. The model interface presented in this paper enables a uniform process of establishing and managing assurance case references to various types...
-
Modeling the electrical characteristics of P3HT:PCBM bulk heterojunction solar cells: Influence of the interface recombination
PublikacjaThe interface recombination of charge carriers located in the material with lower permittivity (Szmytkowski 2009 Chem.Phys.Lett. 470 123) has been implemented for the first time to calculate the electrical characteristics of the donor-acceptor P3HT:PCBM bulk heterojunction solar cell. In order to estimate the photocurrent density in this system, a simple analytical formula has been derived. We have obtained a very good agreement...
-
Investigation of abdomen surface deformation due to life excitation: implications for implant selection and orientation in laparoscopic ventral hernia repair
PublikacjaVentral hernia is a common medical problem. Statistically there are around 10% recurrences of the sickness. The authors' former investigation proved edges of the hernia orifice displacements to be one of the factors causing recurrence. Thus, experimental investigation of the abdomen surface deformation due to some normal activities of people is studied.The extreme strains, their localization and directions are identified. The acquired...
-
A facile approach to fabricate load-bearing porous polymer scaffolds for bone tissue engineering
PublikacjaBiodegradable porous scaffolds with oriented interconnected pores and high mechanical are load-bearing biomaterials for bone tissue engineering. Herein, we report a simple, non-toxic, and cost-effective method to fabricate high-strength porous biodegradable scaffolds, composed of a polymer matrix of polycaprolactone (PCL) and water-soluble poly (ethylene oxide) (PEO) as a sacrificial material by integrating annealing treatment,...
-
Daily oligofructose-enriched inulin intake impacts bone turnover markers but not the cytokine profile in pediatric patients with celiac disease on a gluten-free diet: Results of a randomised, placebo-controlled pilot study
Publikacja -
The reactions occuring on the implant as a result of contact with human tissue
PublikacjaObecnosc implantu w ciele czlowieka powoduje liczne, czesto nieprzewidywalne skutki. Powodem takiej sytuacji jest duza roznorodnosc interakcji materialu medycznego z kontaktujaca sie z nim tkanka. Stwierdzenie to dotyczy glownie oddzialywan i skutkow zachodzacych na poziomie molekularnym w poszczegolnych komorkach kontaktujacej sie tkanki.
-
Behaviour of Fascia-Implant Structure under the Impulse Pressure
PublikacjaW pracy przedstawiono badania eksperymentalne wykonane dla modeli zaoperowanych przepuklin brzusznych poddanych impulsowemu działaniu ciśnienia, analogicznego do kaszlu pooperacyjnego. Zbudowano 57 modeli zgodnie ze sztuką oparacji laparoskopowej, z użyciem powiezi świńskiej, pięciu typów implantów i pięciu rodzajów łączników. Opisano otrzymane wyniki wskazując na mocniejsze i słabsze rozwiązania operacyjne.
-
Logical Interface for Soft Handover – an effective scheme of handovers in Proxy Mobile IPv6
PublikacjaMultimedia services are currently commonly available on mobile devices. Due to networks' convergence and migration to all-IP networks, mobility management at network layer is required. Moreover, nowadays it is popular to equip mobile devices with more than one wireless interface. Thus, soft handovers can be implemented, which means that an existing connection is removed after a new one is established. Usage of the Logical Interfaces...
-
Connectivity in Multi-Interface Networks
PublikacjaRozważano zagadnienie minimalizacji energii w sieciach bezprzewodowych bez infrastruktury, w których niektóre węzły są wyposażone w więcej, niż jeden interfejs. W przyjętym modelu sieci podano nowe algorytmy przybliżone oraz wyniki dotyczące złożoności obliczeniowej dla problemu najtańszej spójnej podsieci spinającej.
-
Bone healing under different lay‐up configuration of carbon fiber‐reinforced PEEK composite plates
PublikacjaSecondary healing of fractured bones requires an application of an appropriate fixa-tor. In general, steel or titanium devices are used mostly. However, in recent years,composite structures arise as an attractive alternative due to high strength to weightratio and other advantages like, for example, radiolucency. According to Food andDrug Administration (FDA), the only unidirectionally reinforced composite allowed tobe implanted...
-
Deep learning approach on surface EEG based Brain Computer Interface
PublikacjaIn this work we analysed the application of con-volutional neural networks in motor imagery classification for the Brain Computer Interface (BCI) purposes. To increase the accuracy of classification we proposed the solution that combines the Common Spatial Pattern (CSP) with convolutional network (ConvNet). The electroencephalography (EEG) is one of the modalities we try to use for controlling the prosthetic arm. Therefor in this...
-
Porosity and swelling properties of novel polyurethane–ascorbic acid scaffolds prepared by different procedures for potential use in bone tissue engineering
PublikacjaIn this work, a novel polyurethane (PU) system based on poly(ethylene-butylene) adipate diol, 1,6-hexamethylene diisocyanate, 1,4-butanediol, and ascorbic acid was used to prepare scaffolds with potential applications in bone tissue engineering. Two fabrication methods to obtain porous materials were chosen: phase separation (PS)/salt particle leaching (PL) and solvent casting (SC)/salt PL. The calculated porosity demonstrated...
-
Short ultrasonic waves in cancellous bone
Publikacja -
Tribology of bone tissue culture in bioreactor.
PublikacjaOpracowano system tribologiczny powstających sił tarcia w bioreaktorze. Pomimo, że wartości sił tarcia osiągają wartości poniżej 0,1 N to mają one decydujący wpływ na wartość porostu tkanki. Mechanika opływu tkanki cieczą o właściwościach biologicznych nienewtonowskich oraz hydrodynamiczna teoria opływu warstwy przyściennej jest bazą wyznaczania parametrów trybologicznychniniejszej pracy.
-
Mechanical model of fascia-implant structure. Finite element simulation.
PublikacjaPraca dotyczy modelowania i symulacji syntetycznych implantów chirurgicznych stosowanych w leczeniu przepulin brzusznych metodą laparoskowpową. Prponowane są modele matematyczne a ich prawidłowość weryfikowana jest na podstawie badań doświadczalnych zachowania się modeli fizycznych wszczepionych implantów pod wpływem obciążeń wynikających z fizjologii człowieka. Nakreślona jest metodologia oceny trwałości połączenia siatki chirurgicznej...
-
Human-Computer Interface Based on Visual Lip Movement and Gesture Recognition
PublikacjaThe multimodal human-computer interface (HCI) called LipMouse is presented, allowing a user to work on a computer using movements and gestures made with his/her mouth only. Algorithms for lip movement tracking and lip gesture recognition are presented in details. User face images are captured with a standard webcam. Face detection is based on a cascade of boosted classifiers using Haar-like features. A mouth region is located in...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublikacjaA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
The effective elastic properties of human trabecular bone may be approximated using micro-finite element analyses of embedded volume elements.
PublikacjaBoundary conditions (BCs) and sample size affect the measured elastic properties of cancellous bone. Samples too small to be representative appear stiffer under kinematic uniform BCs (KUBCs) than under periodicity-compatible mixed uniform BCs (PMUBCs). To avoid those effects, we propose to determine the effective properties of trabecular bone using an embedded configuration. Cubic samples of various sizes (2.63, 5.29, 7.96, 10.58...
-
User experience and user interface (UX/UI) design of Greencoin mobile application.
PublikacjaThe aim of the Greencoin mobile application is to encourage its users to change their behavior and to act pro-ecologically. The pilot version of the application will operate within the city of Gdańsk. To keep the app’s user base as large as possible, the graphical user interface should be attractive to the broadest possible audience, and the application itself should be easy and fun to use. This work is a continuation of studies...
-
Downlink Capacity-Coverage Trade-off Estimation Based on Measurement of WCDMA/FDD Interface Load
PublikacjaThe method of capacity-coverage trade-off determination by using of universal load characteristics and normalized coverage curves for the WCDMA/FDD radio interface has been presented. The practical applications of discussed method for UMTS radio network planning process and network exploitation has been mentioned.
-
Performance analysis of data transmission in MC-CDMA radio interface with turbo codes
PublikacjaMulti-carrier code division multiple access (MC-CDMA) technique is a combination of two radio access techniques: CDMA and orthogonal frequency division multiplexing and has the advantages of both techniques. The paper presents the design of transmitter and receiver for MC-CDMA radio interface. It also presents encoders and decoders of turbo codes which were used in simulation of the MC-CDMA technique. Two turbo codes with 8-state...
-
Cost-Effective and Sufficiently Precise Integration Method Adapted to the FEM Calculations of Bone Tissue
PublikacjaThe technique of Young’s modulus variation in the finite element is not spread in biomechanics. Our future goal is to adapt this technique to bone tissue strength calculations. The aim of this paper is to present the necessary studies of the element’s integration method that takes into account changes in material properties. For research purposes, a virtual sample with the size and distribution of mechanical properties similar...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublikacjaIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Cost minimisation in multi-interface networks
PublikacjaPraca dotyczy problemu minimalizacji energii poprzez selektywne odłączanie urządzeń komunikacyjnych w wielointerfejsowych sieciach bezprzewodowych w taki sposób, by zapewnić realizację wymaganego grafu połączeń. Sformułowano problem optymalizacyjny, podano wyniki dotyczące jego trudności i zaproponowano algorytmy optymalizacyjne.
-
FE simulations of a soil structure interface.
PublikacjaPrzedstawiono warunki brzegowe do opisu szorstkości ściany konstrukcji w kontakcie z gruntem. Wykonano doświadczenia i symulacje MES na bazie mikropolarnego prawa hipoplastycznego.
-
On the tendency of temperature and electric field dependences of interface recombination in P3HT:PCBM organic bulk heterojunction solar cells
PublikacjaWe demonstrate theoretical explanation of the temperature and electric field dependences of recombination coefficients in an organic P3HT:PCBM bulk heterojunction solar cell. Based onthe model of interface recombination, two analytical formulas describing the relative ratio of the interface (γI ) to the Langevin (γL) recombination coefficients have been derived. Our analysis indicates that the sign of parameters φT and φF determines...
-
Thermal utilization of meat and bone meals. Performance analysis in terms of drying process, pyrolysis and kinetics of volatiles combustion
PublikacjaA development of technology of thermal utilization requires a thorough knowledge of the physicochemical properties, as well as kinetics of combustion of volatiles and char. Due to waste management regulations the meat and bone meal (MBM) is regarded as biofuel constituting one of the alternatives to fossil fuels in the energy market. MBM is a heterogeneous material that may consist of several different fractions. The extensive...
-
The Staged Combustion of Meat-and-Bone Meal:The Characteristics of Conversion Sub-processes and Large-Scale Process Outputs
Publikacjat Organic waste has been playing an increasingly important role in the energy market as those that may support the economies in pursuing towards decarbonization by increasing the share of renewables in the overall energy balance. In this group of alternative fuels, meat-and-bone meals being a post-production waste of the steadily developing meat industry, constitute a considerable proportion. Though they are rich in minerals, their...
-
Polymer based thick films - material quality and interface resistance evaluation
PublikacjaThe properties of polymer based thick film layers mede using different resistive pastes and dipping silvers have been studied. The composite of carbon and graphite (C/Gr) conducting particles suspended in different polymer vehicles were used for preparation resistive layers. Interface resistance Rc created between dipping silver (DiAg) contact layer and resistive layer was determined from the surface potential distribution measurements...
-
Analisys of the failure of fixator used in bone surgery
PublikacjaThe Gamma nail (fixator) made of stainless steel, which has broken in the body, was subjected to examination. The fixator was removed from the patient femur. The fracture occurred in the area of the nail hole after two months' stay in the organism. The research included chemical composition, hardness of the Gamma nail material and the observation and analysis of the type of fracture. The research showed the fatigue failure of the...
-
Porous materials used as inserted bone implants
PublikacjaArtykul zawiera przegladowa analize literatury dotyczaca scaffoldow
-
Bone status in adolescents with type 1 diabetes
Publikacja -
Hydroxyapatite films as biocompatibile coating for artifical bone
PublikacjaW artykule została szczegółowo opisana budowa kości oraz materiał biokompatybilny hydroksyapatyt (HAp). Autorzy wykazali jak wielkie podobieństwo do budowy kości przejawia sztuczny hydroksyapatyt. opisali syntezy powłoki z HAp.
-
Enzymatic cross-linking of β-lactoglobulin in solution and at air–water interface: Structural constraints
PublikacjaEffective and controlled use of cross-linking enzymes in structure engineering of food systems depends on characterization of the favorable conditions for enzyme-substrate complex and the limiting factors for the desired modification. In this respect, we analyzed the susceptibility of bovine β-lactoglobulin (BLG) to enzymatic cross-linking by Trichoderma reesei tyrosinase (TrTyr) and transglutaminase (TG). Changes in BLG molecular...
-
Electrical Interface Parameters of PEDOT: PSS: Effect of Electrodeposition Charge Evaluated Under Body Conditions for Neural Electrode Applications
PublikacjaThis study explores the influence of the deposition charge of poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) on its electrical interface parameters. For this purpose, PEDOT:PSS was fabricated by electrodeposition on commercial platinum electrodes with the time limited by different charges (1, 3, 6, 9 mC). Further, the electrodes were characterized regarding their electrical interface such as interfacial...
-
How Integration of a Brain-Machine Interface and Obstacle Detection System Can Improve Wheelchair Control via Movement Image
PublikacjaThis study presents a human-computer interaction combined with a brain-machine interface (BMI) and obstacle detection system for remote control of a wheeled robot through movement imagery, providing a potential solution for individuals facing challenges with conventional vehicle operation. The primary focus of this work is the classification of surface EEG signals related to mental activity when envisioning movement and deep relaxation...
-
Influence of intermixing at the Ta/CoFeB interface on spin Hall angle in Ta/CoFeB/MgO heterostructures
PublikacjaWhen a current is passed through a non-magnetic metal with strong spin-orbit coupling, an orthogonal spin current is generated. This spin current can be used to switch the magnetization of an adjacent ferromagnetic layer or drive its magnetization into continuous precession. The interface, which is not necessarily sharp, and the crystallographic structure of the nonmagnetic metal can both affect the strength of current-induced...
-
Injectable bone cement based on magnesium potassium phosphate and cross-linked alginate hydrogel designed for minimally invasive orthopedic procedures
PublikacjaBone cement based on magnesium phosphate has extremely favorable properties for its application as a bioactive bone substitute. However, further improvement is still expected due to difficult injectability and high brittleness. This paper reported the preparation of novel biocomposite cement, classified as dual-setting, obtained through ceramic hydration reaction and polymer cross-linking. Cement was composed of magnesium potassium...
-
Intelligent thermal imaging camera with network interface
Publikacja -
Cost minimisation in unbounded multi-interface networks
PublikacjaW pracy badano problem odłączania niektórych urządzeń komunikacyjnych w wielointerfejsowych sieciach bezprzewodowych w taki sposób, by zapewnić realizację wymaganego grafu połączeń przy jednoczesnej minimalizacji zużycia energii. Sformułowano problem optymalizacyjny, podano wyniki dotyczące jego trudności i zaproponowano algorytmy optymalizacyjne dla wariantu, w którym liczba interfejsów komunikacyjnych jest potencjalnie nieograniczona...
-
Interoperability analysis of sensor interface in ubiquitous environments
PublikacjaSystemy przetwarzania wszechobecnego pozwalają na integrację różnorodnych sensorów monitorujących i dostarczających informacje dotyczące środowiska oraz jego kontekstu.Fakt, że sensory te implementowane są przez niezależnych dostawców skutkuje problemami integracyjnymi. W artykule przedstawiono wyniki analizy interfejsów sensorów w trzech warstwach: fizycznej, protokołów oraz usług sensorów.Usługa sensora implementuje interfejs...
-
Complex human computer interface for las patient
PublikacjaW pracy zaprezentowano system umożliwiający komunikację osobie sparaliżowanej z komputerem przy pomocy wzroku.
-
Multimedia interface using head movements tracking
PublikacjaThe presented solution supports innovative ways of manipulating computer multimedia content, such as: static images, videos and music clips and others that can be browsed subsequently. The system requires a standard web camera that captures images of the user face. The core of the system is formed by a head movement analyzing algorithm that finds a user face and tracks head movements in real time. Head movements are tracked with...
-
Analysis of the image force effects on the recombination at the donor-acceptor interface in organic bulk heterojunction solar cells
PublikacjaWe consider the influence of image force effects on the recombination at the donor-acceptor interface in organic bulk heterojunction solar cells. The conclusion is that the charge carriers of one sign located in the material with lower permittivity recombine at the boundary between donor and acceptor phases. This process competes with the recombination of opposite sign charge carriers, leading to the reduction of the Langevin-type...
-
Identification of the damage mechanism in orthopaedic implant. Case study including the biomechanical analysis
Publikacja -
Impact of dyes isomerization effect on the charge transfer phenomenon occurring on the dye/nanosemiconductor interface
PublikacjaThe present work aimed to find the answer how does the isomerization of the Ru based dyes affect the overall photon-to-current efficiency of the DSSCs and to explain the charge transfer phenomenon occurring on the dye/ nanosemiconductor interface. Therefore, electronic and optical properties of three bipyridine derivatives anchored on the TiO2 electrode were investigated by computational simulations based on quantum chemistry codes...
-
Human Computer Interface for Tracking Eye Movements Improves Assessment and Diagnosis of Patients With Acquired Brain Injuries
PublikacjaOne of the first clinical signs differentiating the minimally conscious state from the vegetative state is the presence of smooth pursuit eye movements occurring in direct response to moving salient stimuli. Glasgow Coma Scale (GCS) is one of the most commonly used diagnostic tools for acute phase assessment of the level of consciousness, together with a neurological examination. These classic measures are limited to qualitative...