Wyniki wyszukiwania dla: sensor network
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublikacjaIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Assessment of the Speed Management Impact on Road Traffic Safety on the Sections of Motorways and Expressways Using Simulation Methods
PublikacjaMethods used to evaluate the impact of Intelligent Transport System (ITS) services on road safety are usually based on expert assessments or statistical studies. However, commonly used methods are challenging to apply in the planning process of ITS services. This paper presents the methodology of research using surrogate safety measures calculated and calibrated with the use of simulation techniques and a driving simulator. This...
-
Data Integration from GPS and Inertial Navigation Systems for Pedestrians in Urban Area
PublikacjaThe GPS system is widely used in navigation and the GPS receiver can offer long-term stable absolute positioning information. The overall system performance depends largely on the signal environments. The position obtained from GPS is often degraded due to obstruction and multipath effect caused by buildings, city infrastructure and vegetation, whereas, the current performance achieved by inertial navigation systems (INS) is still...
-
Effect of dendrimer-based interlayers for enzyme immobilization on a model electrochemical sensing system for glutamate
PublikacjaIn this paper, we discuss dendrimer usage in enzyme-based electrochemical biosensors, particularly with respect to biomolecule loading on the sensing surface. A novel approach to design bioactive layers with immobilized enzymes for electrochemical biosensors using the surface plasmon resonance (SPR) method in combination with electrochemical impedance spectroscopy was presented. The gold surface was modified with linear linkers...
-
A novel dual-band rectifier circuit with enhanced bandwidth for RF energy harvesting applications
PublikacjaIn recent years, a rapid development of low-power sensor networks, enabling machine-to-machine communication in applications such as environmental monitoring, has been observed. Contemporary sensors are normally supplied by an external power source, typically in a form of a battery, which limits their lifespan and increases the maintenance costs. This problem can be addressed by harvesting and converting ambient RF energy into...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublikacjaLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
Low-strain sensor based on the flexible boron-doped diamond-polymer structures
PublikacjaA free-standing high boron-doped diamond nanosheet (BDDNS) has been fabricated for the development of a flexible BDDNS strain senor. High boron-doped diamond was initially grown on a tantalum substrate in a microwave plasma-assisted chemical vapor deposition method, and was then transferred to a Kapton polymer substrate to fabricate the flexible BDDNS/Kapton device. Before performing the transfer process, the thin BDDNS’s morphology...
-
Development of Gas Sensor Array for Methane Reforming Process Monitoring
PublikacjaThe article presents a new method of monitoring and assessing the course of the dry methane reforming process with the use of a gas sensor array. Nine commercially available TGS chemical gas sensors were used to construct the array (seven metal oxide sensors and two electrochemical ones). Principal Component Regression (PCR) was used as a calibration method. The developed PCR models were used to determine the quantitative parameters...
-
Usage of parametric echosounder with emphasis on buried object searching.
PublikacjaThe purpose of this article is to present the results of investigation to search for buried objects. The paper will contain echograms and other means of visualization from buried pipe placed between area of W?adys?awowo and gas platform and interesting in terms of the number of small and medium-sized unidentified objects found in the muddy bottom at different depths localized in the Gulf of Puck - results will be presented also...
-
Ordered titanium templates functionalized by gold films for biosensing applications – Towards non-enzymatic glucose detection
PublikacjaRecently, metal nanostructures evoke much interest due to application potential in highly sensitive detectors in biochemistry and medical diagnostics. In this work we report on preparation and characteristics of thin (1–100 nm) Au films deposited onto highly ordered structured titanium templates for SERS (Surface Enhanced Raman Spectroscopy) and electrochemical sensing. The Ti templates are formed by selective removal of TiO2 nanotubes...
-
Hybrid‐mode single‐slope ADC with improved linearity and reduced conversion time for CMOS image sensors
PublikacjaIn the paper, a single‐slope analog‐to‐digital converter (ADC) for integrated CMOS image sensor applications with an improved technique of conversion has been proposed. The proposed hybrid‐mode ADC automatically uses one of the following conversion techniques: time based (i.e. PWM) or voltage based (i.e. single‐slope). During the ADC operation, the clock frequency and reference voltage are modified in order to reduce the conversion...
-
Dynamic mass measurement in checkweighers using a discrete time-variant low-pass filter
PublikacjaConveyor belt type checkweighers are complex mechanical systems consisting of a weighing sensor (strain gauge load cell, electrodynamically compensated load cell), packages (of different shapes, made of different materials) and a transport system (motors, gears, rollers). Disturbances generated by the vibrating parts of such a system are reflected in the signal power spectra in a form of strong spectral peaks, located usually in...
-
Do Phenyl Substituents Affect the Properties of Azobenzocrown Derivatives?
PublikacjaNew products of photo- and thermal rearrangements of 19-membered azoxybenzocrown with phenyl substituents in benzene rings in the para positions to oligooxyethylene fragments are characterized. The yields of photochemical transformations depend on the solvent. Para-hydroxyazocrown is formed with yields over 50% in propan-2-ol. Ortho-hydroxyazobenzocrown is obtained with yields up to 70% in toluene/acetic acid mixture. Macrocyclic...
-
Privacy-Preserving, Scalable Blockchain-Based Solution for Monitoring Industrial Infrastructure in the Near Real-Time
PublikacjaThis paper proposes an improved monitoring and measuring system dedicated to industrial infrastructure. Our model achieves security of data by incorporating cryptographical methods and near real-time access by the use of virtual tree structure over records. The currently available blockchain networks are not very well adapted to tasks related to the continuous monitoring of the parameters of industrial installations. In the database...
-
Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation
PublikacjaIn brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and...
-
Optical investigations of electrochemical processes using a long-period fiber grating functionalized by indium tin oxide
Publikacjahe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Study on Combined Optical and Electrochemical Analysis Using Indium-tin-oxide-coated Optical Fiber Sensor
PublikacjaThe growing needs for fast and reliable sensing devices stimulate development of new technological solutions. In this work a new multi-domain sensing method is demonstrated where optical sensing device has been applied to enhance amount of data received during electrochemical analysis. Thin, optically transparent, high-refractive-index, and electrically conductive indium tin oxide (ITO) film was deposited using magnetron sputtering...
-
Optical properties of thin TiO2 film deposited on the fiber optic sensor head
PublikacjaThe presented study was focused on investigation of the titanium dioxide (TiO2) thin film deposited on the fiber tip. The intention of this investigation was using TiO2 film in the construction of the optical fiber sensor head. In the demonstrated construction TiO2 thin layer was deposited on the tip of a commonly used telecommunication single mode optical fiber (SMF-28) by means of the Atomic Layer Deposition (ALD). Thickness...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h. High frequency burst recording.
Dane BadawczeWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. High frequency burst recording.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21,...
-
Heart rate PPG signals with acceleration captured at wrist during small and moderate body movements
Dane BadawczeHeart rate PPG signals with acceleration captured at wrist during small and moderate body movements
-
Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Electronic nose algorithm design using classical system identification for odour intensity detection
PublikacjaThe two elements considered crucial for constructing an efficient environmental odour intensity monitoring systems are sensors and algorithms typically addressed to as electronic nose sensor (e-nose). Due to operational complexity of biochemical sensors developed in human bodies algorithms based on computational methods of artificial intelligence are typically considered superior to classical model based approaches in development...
-
Laser-Induced Graphitization of Polydopamine on Titania Nanotubes
PublikacjaSince the discovery of laser-induced graphite/graphene, there has been a notable surge of scientific interest in advancing diverse methodologies for their synthesis and applications. This study focuses on the utilization of a pulsed Nd:YAG laser to achieve graphitization of polydopamine (PDA) deposited on the surface of titania nanotubes. The partial graphitization is corroborated through Raman and XPS spectroscopies and supported...
-
Exploring multi-step glucose oxidation kinetics at GOx-functionalized nanotextured gold surfaces with differential impedimetric technique
PublikacjaFor a few past years, we can observe the enormous growth of investigations related to ultrasensitive electrochemical sensors capable of reliable determination of important body parameters and analytes. Utilized procedures rely on standard electrochemical methods, demanding electrode polarization, and information about the initial characteristics of the working electrode. More and more complex electrode materials are characterized...
-
Axial-Flux Permanent-Magnet Dual-Rotor Generator for a Counter-Rotating Wind Turbine
PublikacjaCoaxial counter-rotating propellers have been widely applied in ships and helicopters for improving the propulsion efficiency and offsetting system reactive torques. Lately, the counter-rotating concept has been introduced into the wind turbine design. Distributed wind power generation systems often require a novel approach in generator design. In this paper, prototype development of axial-flux generator with a counter-rotating...
-
Investigation of poly(3,4-ethylenedioxythiophene) deposition method influence on properties of ion-selective electrodes based on bis(benzo-15-crown-5) derivatives
PublikacjaGlassy carbon electrodes modified by conductive polymers and membrane with derivatives of bis(benzo-15-crown-5) were tested as solid contact ion selective electrodes for K+ ions concentration determination. PEDOT with PSS, Cl- and ClO4- counter ions was electrochemically deposited onto glassy carbon substrates using four different electrochemical approaches (potentiostatic, galvanostatic, potentiodynamic and potentiostatic pulses)....
-
The Use of Big Data in Regenerative Planning
PublikacjaWith the increasing significance of Big Data sources and their reliability for studying current urban development processes, new possibilities have appeared for analyzing the urban planning of contemporary cities. At the same time, the new urban development paradigm related to regenerative sustainability requires a new approach and hence a better understanding of the processes changing cities today, which will allow more efficient...
-
Calibration of NTC 10k thermistors in temperature of 0 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 100 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 50 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Reconstruction of 3D image of corona discharge streamer
PublikacjaIn this paper, the method of reconstruction of the 3D structure of streamers in DC positive corona discharge in nozzle-to-plate electrode configuration is presented. For reconstructing of 3D image of corona discharge streamer we propose a stereographical method, where streamers are observed from several directions simultaneously. The multi-directional observation enabled to obtain fine positional coordinates of streamers for a...
-
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publikacja.A boron-doped diamond (BDD) sensor is proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Boron-doped diamond thin films, acting as active sensors, were deposited on both silicon wafer and glassy carbon (GC) substrates by microwave plasma assisted chemical vapour deposition. SEM micrographs showed that BDD–Si displays triangle-faceted crystallites ca. 0.5–3 μm in size, while BDD–GC...
-
MnWO4/reduced graphene oxide-based electrochemical sensing platform for simultaneous detection of catechol and resorcinol
Publikacjan this study, a novel electrochemical sensor for accurate and sensitive catechol determination was demonstrated employing a screen-printed graphite electrode (SPGE) modified with MnWO4/reduced graphene oxide (MnWO4/rGO) nanocomposite. The MnWO4/rGO nanocomposite has been successfully prepared by using hydrothermal technique, and it was then characterized using several microscopic and spectroscopic methods (XRD, FE-SEM, and EDS)....
-
The evaluation of eGlasses eye tracking module as an extension for Scratch
PublikacjaIn this paper we present the possibility of using eGlasses eye tracking module as an extension for Scratch programming tool which is a visual programming language supporting computer skills learning. The main concept behind this project is to setup the interface for rapid interaction design. Eye tracking is a powerful tool for hands free communication but for that requires a dedicated software. This software is rarely tailored...
-
Highly selective impedimetric determination of Haemophilus influenzae protein D using maze-like boron-doped carbon nanowall electrodes
PublikacjaThis study reports a novel impedimetric immunosensor for protein D detection in purified and bacterial (Haemophilus influenzae, Hi) samples. The detection was based on antigen recognition by anti-protein D antibodies (apD) immobilised at the maze-like boron-doped carbon nanowall electrodes (B:CNW). The B:CNW electrodes were synthesised, and their surface was characterised by scanning electron microscopy (SEM) and X-ray photoelectron...
-
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
PublikacjaIn this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations....
-
Optimizing Ni–Cr patterned boron-doped diamond band electrodes: Doping effects on electrochemical efficiency and posaconazole sensing performance
PublikacjaThere is growing interest in developing diamond electrodes with defined geometries such as, for example, micrometer-sized electrode arrays to acquire signals for electroanalysis. For electroanalytical sensing applications, it is essential to achieve precise conductive patterns on the insulating surface. This work provides a novel approach to boron-doped diamond patterning using nichrome masking for selective seeding on an oxidized...
-
The effects of gas exposure on the graphene/AlGaN/GaN heterostructure under UV irradiation
PublikacjaThis work demonstrates a graphene/AlGaN/GaN sensing device with two-dimensional electron gas (2DEG) toward nitrogen dioxide (NO2), tetrahydrofuran, and acetone detection under UV light irradiation. We propose combining measurements of the DC characteristics with a fluctuation-enhanced sensing method to provide insight into the gas detection mechanisms in the synergistic structure of highly stable GaN and gas-sensitive graphene....
-
Concept of an Innovative System for Dimensioning and Predicting Changes in the Coastal Zone Topography Using UAVs and USVs (4DBatMap System)
PublikacjaThis publication is aimed at developing a concept of an innovative system for dimensioning and predicting changes in the coastal zone topography using Unmanned Aerial Vehicles (UAVs) and Unmanned Surface Vehicles (USVs). The 4DBatMap system will consist of four components: 1. Measurement data acquisition module. Bathymetric and photogrammetric measurements will be carried out with a specific frequency in the coastal zone using...
-
Contextual Knowledge to Enhance Workplace Hazard Recognition and Interpretation in a Cognitive Vision Platform
PublikacjaThe combination of vision and sensor data together with the resulting necessity for formal representations builds a central component of an autonomous Cyber Physical System for detection and tracking of laborers in workplaces environments. This system must be adaptable and perceive the environment as automatically as possible, performing in a variety of plants and scenes without the necessity of recoding the application for each...
-
Non-enzymatic flexible glucose sensing platform based on nanostructured TiO2–Au composite
PublikacjaAll over the world the number of people suffering from diabetes and related complications is drastically growing. Therefore, the need for accurate, reliable and stable sensor for monitoring of glucose in human body fluids is becoming highly desirable. In this work we show that material composed of gold layers deposited onto TiO2 nanotubes (NTs) formed onto the flexible Ti foil exhibits great response toward glucose oxidation and...
-
AUTOMATED SYSTEM FOR FLUCTUATION ENHANCED GAS SENSING
PublikacjaResistance gas sensors exhibit random phenomena (resistance noise) which can be utilized to improve gas sensitivity and selectivity. That new emerging technique has to be investigated to recognize optimal parameters for gas detection. It means that a measurement system has to have ability of numerous parameters adjustment (e.g., sampling frequency, heater voltage, polarization current, voltage noise amplification). That fact induced...
-
Ultrasonic wave propagation and digital image correlation measurements of steel bars under 3-point bending
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a bar under a 3-point bending test. The bar was made of steel and had a cross-section of 5.96 × 5.96 mm2 and a length of 200 mm. The three-point bending test was performed using a Zwick/Roell Z10 universal testing machine (UTM), with a distance between supports of 12 cm. The parameters...
-
Automatic Identification System (AIS) Dynamic Data Integrity Monitoring and Trajectory Tracking Based on the Simultaneous Localization and Mapping (SLAM) Process Model
PublikacjaTo enhance the safety of marine navigation, one needs to consider the involvement of the automatic identification system (AIS), an existing system designed for ship-to-ship and shipto- shore communication. Previous research on the quality of AIS parameters revealed problems that the system experiences with sensor data exchange. In coastal areas, littoral AIS does not meet the expectations of operational continuity and system availability,...
-
Emerging strategies for enhancing detection of explosives by artificial olfaction
PublikacjaExplosives detection systems need to be able to reliably detect a wide range of explosive materials and their vapours. The continued development and improvement of artificial olfaction techniques, including electronic nose (EN), remains important to overcome existing challenges and meet requirements posed by new improvements in the field of explosives. There is an increasingly popular trend aimed at improvement of fundamental metrological...
-
Tailoring properties of indium tin oxide thin films for their work in both electrochemical and optical label-free sensing systems
PublikacjaThis work is devoted to the identification properties of indium tin oxide (ITO) thin films responsible for their possible application in combined optical and electrochemical label-free sensing systems offering enhanced functionalities. Since any post-processing would make it difficult to identify direct relation between deposition parameters and properties of the ITO films, especially when deposition on temperature-sensitive substrates...
-
Portable raman spectrometer for maritime security applications
PublikacjaThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is widely used for fast identification of various chemicals. Continuous progress in the field of photonics has resulted in commercial availability of low-power compact Raman spectrometers which can be integrated into portable systems....
-
Potentiometric sensor with lipid-polymer membranes for quality assessment of French red wines
PublikacjaThe quality of wines resulting from vineyard management is important for consumers due to the taste and price of wines. In this work, the quality of red wines of three vintages has been investigated by potentiometric sensors with six all-solid-state electrodes. Two series of experiments were carried out. The first involved a qualitative analysis of wine of different vintages from freshly opened bottles. The second consisted of...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublikacjaA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
A Highly Selective Biosensor Based on Peptide Directly Derived from the HarmOBP7 Aldehyde Binding Site
PublikacjaThis paper presents the results of research on determining the optimal length of a peptide chain to eectively bind octanal molecules. Peptides that map the aldehyde binding site in HarmOBP7 were immobilized on piezoelectric transducers. Based on computational studies, four Odorant Binding Protein-derived Peptides (OBPPs) with dierent sequences were selected. Molecular modelling results of ligand docking with selected peptides were...