Filtry
wszystkich: 1958
-
Katalog
- Publikacje 1490 wyników po odfiltrowaniu
- Czasopisma 16 wyników po odfiltrowaniu
- Konferencje 15 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 43 wyników po odfiltrowaniu
- Projekty 18 wyników po odfiltrowaniu
- Laboratoria 2 wyników po odfiltrowaniu
- Zespoły Badawcze 3 wyników po odfiltrowaniu
- Aparatura Badawcza 2 wyników po odfiltrowaniu
- Kursy Online 81 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 285 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: 3d printed sensor
-
Support for Employees with ASD in the Workplace Using a Bluetooth Skin Resistance Sensor–A Preliminary Study
PublikacjaThe application of a Bluetooth skin resistance sensor in assisting people with Autism Spectrum Disorders (ASD), in their day-to-day work, is presented in this paper. The design and construction of the device are discussed. The authors have considered the best placement of the sensor, on the body, to gain the most accurate readings of user stress levels, under various conditions. Trial tests were performed on a group of sixteen...
-
A New Approach to Capacitive Sensor Measurements Based on a Microcontroller and a Three-Gate Stable RC Oscillator
PublikacjaA complete smart capacitive sensor solution basedA complete smart capacitive sensor solution based on a microcontroller was developed. This approach includes the development of both the hardware and software. The hardware part comprises an 8-bit microcontroller equipped with two timers/counters and a three-gate stable RC relaxation oscillator. The software part handles system configuration, measurement control, communication control,...
-
Recent advances in 3D bioprinted tumor models for personalized medicine
PublikacjaCancerous tumors are among the most fatal diseases worldwide, claiming nearly 10 million lives in 2020. Due to their complex and dynamic nature, modeling tumors accurately is a challenging task. Current models suffer from inadequate translation between in vitro and in vivo results, primarily due to the isotropic nature of tumors and their microenvironment's relationship. To address these limitations, hydrogel-based 3D bioprinting...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublikacjaIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
an intelligent image processing sensor - the algorithm and the hardware implementation
PublikacjaW artykule przedstawiono algorytm przeznaczony do rozpoznawania obiektów ruchomych w obrazie do celu analizy ruchu pojazdów. Algorytm został zrealizowany w układzie FPGA.Ang.: This paper describes the idea and theimplementation of the robust algorithm dedicated toextraction of moving vehicles from real-time cameraimages for the evaluation of traffic parameters, suchas the number of vehicles, their direction of movementand their...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublikacjaThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Naturally-derived hydrogels for 3D pancreatic tumor models: A short review
PublikacjaStatistics suggest a high proportion of mortality rate by pancreatic cancer, which is a solid tumor characterized by high heterogeneity and the presence of a complex extracellular matrix. The very low effectiveness of pancreatic cancer treatment roots in the high metastatic potential and drug resistance of this tumor. Therefore, the quest for efficient cellular models enabling precise mimicking in vivo conditions, and anticancer...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublikacjaPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublikacjaMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Electromagnetic Simulations with 3D FEM and Intel Optane Persistent Memory
PublikacjaAbstract—Intel Optane persistent memory has the potential to induce a change in how high-performance calculations requiring a large system memory capacity are conducted. This article presents what this change may look like in the case of factorization of large sparse matrices describing electromagnetic problems arising in the 3D FEM analysis of passive highfrequency components. In numerical tests, the Intel oneAPI MKL PARDISO was...
-
Application of Multiplicative Drift Correction and Component Correction methods on simulated gas sensor array responses
PublikacjaSensor response drift is one of the most challenging problems in gas-analyzing systems. Such systems, commonly called electronic noses, are expected to be reliable and reproducible in the long term. Due to the drift phenomena, electronic noses usability is limited to the relatively short period of time, and frequent recalibrations of device are required. Because it is very hard to fabricate sensors without drift, this phenomenon...
-
Design and Experimental Validation of a Metamaterial-Based Sensor for Microwave Imaging in Breast, Lung, and Brain Cancer Detection
PublikacjaThis study proposes an innovative geometry of a microstrip sensor for high-resolution microwave imaging (MWI). The main intended application of the sensor is early detection of breast, lung, and brain cancer. The proposed design consists of a microstrip patch antenna fed by a coplanar waveguide with a metamaterial layer-based lens implemented on the back side, and an artificial magnetic conductor (AMC) realized on as a separate...
-
Determination of toxic gases based on the responses of a single electrocatalytic sensor and pattern recognition techniques
PublikacjaA response from an electrocatalytic gas sensor contains fingerprint information about the type of gas and its concentration. As a result, a single gas sensor can be used for the determination of different gases. However, information about the type of gas and its concentration is hidden in the unique shape of the current–voltage response and it is quite difficult to explore. One of the ways to get precise information about the measured...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublikacjaThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
A Method and Device for 3D Recognition of Cutting Edge Micro Geometry
PublikacjaA very useful method was successfully applied in the investigation of tools for machining wood and wood based composites. It allows scanning of the cutting edge micro geometry in three dimensions and reproducing it in a virtual space as a 3D surface. The application of the method opens new possibilities of studying tool wear by scanning, including the calculation of volume loss and other analysis of tool wedge geometry along and...
-
Effect of mesh deformation on the accuracy of 3D FEM electromagnetic analysis
PublikacjaIn this paper, the accuracy of 3D FEM electromagnetic simulations in parametric analysis using mesh deformation techniques is discussed. Mesh deformation techniques allow one to preserve the mesh topology while the geometry is changed. It is shown that the application of mesh deformation can provide accurate simulation results even for very large deformations. On the other hand, it is also shown that the technique has to be used...
-
Scene Segmentation Basing on Color and Depth Images for Kinect Sensor
PublikacjaIn this paper we propose a method for segmenting single images from Kinect sensor by considering both color and depth information. The algorithm is based on a series of edge detection procedures designed for particular features of the scene objects. RGB and HSV color planes are separately analyzed in the first step with Canny edge detector, resulting in overall color edges mask. In depth images both clear boundaries and smooth...
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublikacjaThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Autonomous Perception and Grasp Generation Based on Multiple 3D Sensors and Deep Learning
PublikacjaGrasping objects and manipulating them is the main way the robot interacts with its environment. However, for robots to operate in a dynamic environment, a system for determining the gripping position for objects in the scene is also required. For this purpose, neural networks segmenting the point cloud are usually applied. However, training such networks is very complex and their results are unsatisfactory. Therefore, we propose...
-
Multiple sound sources localization in free field using acoustic vector sensor
PublikacjaMethod and preliminary results of multiple sound sources localization in free field using the acoustic vector sensor were presented in this study. Direction of arrival (DOA) for considered source was determined based on sound intensity method supported by Fourier analysis. Obtained spectrum components for considered signal allowed to determine the DOA value for the particular frequency independently. The accuracy of the developed...
-
Multiple sound sources localization in real time using acoustic vector sensor
PublikacjaMethod and preliminary results of multiple sound sources localization in real time using the acoustic vector sensor were presented in this study. Direction of arrival (DOA) for considered source was determined based on sound intensity method supported by Fourier analysis. Obtained spectrum components for considered signal allowed to determine the DOA value for the particular frequency independently. The accuracy of the developed...
-
1D Model Callibration on the Basis on 3D calculations for Tesla Turbine
PublikacjaThe paper presents the system of equations for axisymmetriclaminar flow, after averaging, through the width of interdisk slit ofTesla turbine. Coefficients were introduced, as a result ofaveraging, that improve the efficiency of 1D model. The minimalnumber of such coefficients was determined. The 1D modelmakes it possible to attain analytical solutions to an accuracylimited by these coefficients. Calibration of 1D model depends...
-
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublikacjaIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
GPU-Accelerated 3D Mesh Deformation for Optimization Based on the Finite Element Method
PublikacjaThis paper discusses a strategy for speeding up the mesh deformation process in the design-byoptimization of high-frequency components involving electromagnetic field simulations using the 3D finite element method (FEM). The mesh deformation is assumed to be described by a linear elasticity model of a rigid body; therefore, each time the shape of the device is changed, an auxiliary elasticity finite-element problem must be solved....
-
Qualitative and Quantitative Analysis of Selected Tonic Waters by Potentiometric Taste Sensor With All-Solid-State Electrodes
PublikacjaTaste sensor with five all-solid-state electrodes (ASSE) III (third version) was used for qualitative and quantitative analysis of selected tonic waters (J.Gasco, Kinley, Jurajski, Jurajski with citrus flavor, Carrefour, Schweppes Indian Tonic, and Schweppes Bitter Lemon). The results obtained by this taste sensor analyzed with principal component analysis, agglomerative hierarchical clustering methods show that this sensor can...
-
Application of Web-GIS for Dissemination and 3D Visualization of Large-Volume LiDAR Data
PublikacjaThe increasing number of digital data sources, which allow for semi-automatic collection and storage of information regarding various aspects of life has recently granted a considerable rise in popularity to the term “Big data”. As far as geospatial data is concerned, one of the major sources of Big data are Light Detection And Ranging (LiDAR) scanners, which produce high resolution three-dimensional data on a local scale. The...
-
Optical Sensor Based Gestures Inference Using Recurrent Neural Network in Mobile Conditions
PublikacjaIn this paper the implementation of recurrent neural network models for hand gesture recognition on edge devices was performed. The models were trained with 27 hand gestures recorded with the use of a linear optical sensor consisting of 8 photodiodes and 4 LEDs. Different models, trained off-line, were tested in terms of different network topologies (different number of neurons and layers) and different effective sampling frequency...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublikacjaThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublikacjaThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Zirconia-based mixed potential sensor with Pt electrode prepared by spin-coating of polymeric precursor
PublikacjaMany types of yttria-stabilized zirconia (YSZ) based gas sensors have been explored extensively in recent years. Great attention have been directed to mixed-potential-type gas sensors. It is due to growing concerns with environmental issues. Not without a significance is the fact of very attractive performance of this type of sensor allowing to detect low concentration of pollutant gases. In this paper two types of YSZ based mixed-potential...
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublikacjaA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Improving the Accuracy of Automatic Reconstruction of 3D Complex Buildings Models from Airborne Lidar Point Clouds
PublikacjaDue to high requirements of variety of 3D spatial data applications with respect to data amount and quality, automatized, effcient and reliable data acquisition and preprocessing methods are needed. The use of photogrammetry techniques—as well as the light detection and ranging (LiDAR) automatic scanners—are among attractive solutions. However, measurement data are in the form of unorganized point clouds, usually requiring transformation...
-
Fiber optic sensor based on optical frequency domain reflectometry.Optical Fibres and their Applications VIII.
PublikacjaW pracy przedstawiono wyniki modelowania systemu sensorów światłowodowych wykorzystującego reflektometrię optyczną w dziedzinie częstotliwości. Na podstawie tych wyników zrealizowano quasi-rozłożony sensor temperatury. Zaprezentowano i omówiono wyniki pomiarów.
-
3D Hand Shape Modeling for Automatic Assessing Motor Performance in Parkinson's Disease
PublikacjaIn this paper a method for hand pattern processing to create a 3D hand model is presented. By applying a complete hand armature to the model obtained, an interpolation of three motor tests for an individual Parkinson's disease patient can be performed. To obtain the 3D hand model the top view of the hand from a web cam is analyzed. The hand contour is examined to find characteristic points that allows for dividing hand image into...
-
Polyurethanes as a Potential Medical-Grade Filament for Use in Fused Deposition Modeling 3D Printers – a Brief Review
PublikacjaThe possibility of using 3D printing technology (3DP) in medical field is a kind of revolution in health care. This has contributed to a rapid growth in demand for 3D printers, whose systems and materials are adapted to strict medical requirements. In this paper, we report a brief review of polyurethanes as a potential medical-grade filament for use in Fused Deposition Modeling (FDM) 3D printer technology. The advantages of polyurethanes...
-
Locally sculptured modification of the electrochemical response of conductive poly(lactic acid) 3D prints by femtosecond laser processing
PublikacjaThis manuscript presents an approach to sculpture high electrochemical activity of the 3D printed electrodes with poly(lactic acid) (PLA) matrix and carbon black (CB) filler by femtosecond laser (FSL) ablation. CB-PLA utility for electrochemical applications depends on a surface modification aiming to remove the PLA and uncover the conductive CB. We have discussed how laser pulse energy is critical for such an activation process....
-
Evaluation of Body Surface Area Formulae Based on 3D Body Scans
PublikacjaHuman body surface area (BSA) is an established parameter for the calculation of chemotherapy drugs dosage, treatment of chronic hepatitis B, treatment of burns or for establishing a dosing regimen for antimicrobials. Although being a critical parameter, usage of modern 3D scanners, which would measure the exact BSA value, is often impossible in time-sensitive operations or for patients unable to withstand the scanning process....
-
Real-time monitoring of the emission of volatile organic compounds from polylactide 3D printing filaments
PublikacjaEstablishing the emission profile of volatile organic compounds generated during fused deposition modeling 3D printing using polymer filaments is important in terms of both understanding the processes taking place during thermal degradation of thermoplastics, and assessing the user's exposure to potentially harmful volatiles. However, obtaining detailed, real-time qualitative and quantitative results poses a challenge. In this...
-
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
PublikacjaA unique highly sensitive photonic crystal fiber is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained...
-
Medical-Grade PCL Based Polyurethane System for FDM 3D Printing—Characterization and Fabrication
PublikacjaThe widespread use of three-dimensional (3D) printing technologies in medicine has contributed to the increased demand for 3D printing materials. In addition, new printing materials that are appearing in the industry do not provide a detailed material characterization. In this paper, we present the synthesis and characterization of polycaprolactone (PCL) based medical-grade thermoplastic polyurethanes, which are suitable for forming...
-
Using differential pressure sensor to measure nitrous oxide level in a tank
PublikacjaA method for measuring the level of liquid nitrous oxide oxidizer in a hybrid rocket motor oxidizer tank is proposed. Presented approach is more accurate than the most commonly used method of this measurement, which employs weighting of the whole sounding rocket or an oxidizer tank. In our solution we use a differential pressure sensor to measure the change of pressure at the bottom of an oxidizer tank in comparison to the pressure...
-
3D scanning system for railway current collector contact strips
PublikacjaUndisturbed collection of current from a contact wire of the catenary constitutes one of the basic elements in reliable operation of electrified rail transport, particularly when vehicles move at high speed. Quality of current collection is influenced by the construction of catenary and current collectors, as well as by the technical condition and regulation of these two elements. Total contact force of a current collector head...
-
Analysis of unsteady flow forces on the thermowell of steam temperature sensor
PublikacjaIn this paper, 3D numerical analysis of unsteady flow forces acting on the measuring sheath of steam temperature is presented. According to that purpose, the CFD (Computation Fluid Dynamic [1]) approach has been used. The nonstationary of fluid acting on the measuring sheath such as: Strouhal frequency, amplitude of pressure, structure of vortex, peak of pressure, field of pressure, field of velocity etc. are studied analytically...
-
Application of mesh deformation for modeling of conformal RF components with 3D FEM
PublikacjaIn this paper, a method of analysis of conformal RF components has been proposed. In this approach, modeling of a curved structure is based on mesh deformation of planar objects rather than the construction of conformal geometry at CSG level. Since the model is represented as a 3D mesh, the deformation only requires the calculation of nodes position in the bent structure. The results of the proposed algorithm have been validated...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublikacjaThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
INVESTIGATION OF ACIDIC SOLUTIONS BY POTENTIOMETRIC TASTE SENSOR WITH ALL SOLID STATE ELECTRODES
PublikacjaPotentiometric taste sensors with electrodes containing lipophilic compound / polymer membranes were already used to distinguish commercial liquid products. In this paper a new potentiometric taste sensor consisting of six All Solid State Electrodes (ASSEs) has been presented. Each of the membrane contains a selected lipophilic compound. The set-up consists of a reference electrode and six ASSEs. The inner layer made of a conducting...
-
From a Point Cloud to a 3D Model - an Exercise for Users of AutoCAD and Revit
PublikacjaThe paper presents a proposal of the topic of an exercise for students of building faculties as part of classes on 3D modelling. The task consists in creating a three-dimensional model based on the measurement obtained with the Leica P30 laser scanner. Due to the maximum number of points in the cloud in the presented programs, the output files must be properly cleared and reduced. The point cloud was pre-processed in Cyclone software....
-
Stanowisko do skanowania 3D nakładek odbieraków prądu lokomotyw
PublikacjaPrawidłowy odbiór prądu z sieci jezdnej trakcji elektrycznej jest jednym z podstawowych elementów niezawodnego funkcjonowania zelektryfikowanego transportu szynowego, zwłaszcza przy dużych prędkościach jazdy. Na jakość odbioru prądu wpływa konstrukcja sieci jezdnej i odbieraków prądu oraz stan techniczny i regulacja tych dwóch elementów. O jakości współpracy odbieraka prądu z siecią jezdną zasadniczo decydują: nacisk odbieraka...
-
The possibility of the application of a potentiometric sensor with all-solid-state electrodes for the quality control of different natural waters
PublikacjaThe quality of various natural waters was examined by a new potentiometric sensor with six all solid state electrodes containing an appropriate lipophilic compound in a polymer membrane. Physicochemical parameters such as conductivity and acidity of tested waters were also tested. All waters were neutral or slightly alkaline and contained different ions (e.g., Cl–) due to the place of their sampling (a coastal zone and a moraine...