Filters
total: 2139
filtered: 550
Search results for: determination
-
ThreSpect a program for the determination of the Appearance Energies
Open Research DataDataset presents the “ThreSpect” computer program dedicated to simulating threshold energies of neutral and ionized products generated in the collisions of photons or charged particles with atoms and molecules.
-
Determination of sex hormone concentration in wastewater samples.
Open Research DataConcentration levels of five selected steroid hormones in influent and effluent waters from wastewater treatment plant were determined using SPE(C18)-HPLC-ESI/MS/MS method. Sex hormones like: estradiol, estriol, estrone, 17-α-ethynyloestradiol, progesterone were present in all influent wastwater samples.
-
Assay of Cystathionine-γ-synthase (CaStr2p) activity determination.
Open Research DataThe study aimed to obtain conditions optimal for the activity of Candida albicans cystathionine-γ-synthase (CaStr2p) determination. The selection of appropriate reaction conditions included the identification of the reaction buffer and its pH, substrate, and enzyme concentrations. The activity of Str2p was measured by the detection of decrease of the...
-
Determination of the content of saccharides and ethanol in samples of fermented beverages
Open Research DataThe data set presents the results of measurements of the content of mono- and disaccharides: glucose, maltose, fructose and ethanol in samples of beverages fermented by high performance liquid chromatography (HPLC-RID).
-
Determination of denaturation temperature of connective tissue proteins by viscometric measurements.
Open Research DataViscometric denaturation temperature of connective tissue proteins was determined by measuring viscosity with a Brookfield viscometer, using a LV SC4 - 18, 25 or LV3 spindle and shear rates from 50 to 110 s-1 (Fig.1). Freeze-dried protein samples were dissolved in 0.5 M acetic acid at 4 °C and concentration of 20 mg/mL. The solution was stirred with...
-
Determination of viscosity changes in dietary supplement solutions depending on temperature.
Open Research DataThe rheological characteristics of dietary supplement solutions were made based on viscosity measurement using a Brookfield viscometer, using the LV SC4 - 18 spindle and a shear rate of 53 s-1 (Fig.1).
-
Determination of changes in viscosity of chitosan solutions depending on shear rate.
Open Research DataThe rheological characteristics of chitosan solutions were based on viscosity measurements using a Brookfield viscometer, using LV SC4 - 25 spindles and shear rates from 4 to 53 s-1 (Fig. 1). Chitosan solutions with different molecular weights (low, medium and high) were prepared in concentrations from 1.5 to 3.0% in 0.5M acetic acid. The data allowed...
-
Determination of mechanical properties of human stomach tissues subjected to uniaxial stretching
Open Research DataThe aim of the study was to determine the biomechanical properties of the walls of the human stomach. The samples were fragments of the human stomach obtained after sleeve gastrectomy. Samples cut parallel to the stomach curves and perpendicular to the stomach curves were tested in each series. All samples were subjected to uniaxial stretching. During...
-
Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Determination of viscosity changes of protein hydrolyzate solutions depending on shear rate
Open Research DataRheological characteristics of connective tissue protein solutions were made on the basis of viscosity measurement using a Brookfield viscometer using LV SC4 - 27 spindles and shear rate of 85 s-1 (Fig. 1). Solutions of protein hydrolysates with a concentration of 2% in 0.5M acetic acid were prepared.
-
Determination of changes in viscosity of chitosan cosmetic preparations depending on shear rate.
Open Research DataThe rheological characteristics of chitosan were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindles and shear rates from 0.3 to 32 s-1 (Fig. 1). Chitosan solutions at 1% concentrations in acetic acid were prepared. The samples were subjected to storage tests.
-
SEM and Raman studies B:CNWs and BDD electrode used for electrochemical paraquat determination
Open Research DataThe dataset contains the scanning electron micrographs (SEM) and Raman spectra of B:CNWs and BDD samples deposited by MW-PECVD. SEM was used to characterise the morphology of BDD and B:CNW. In contrast, RAMAN was used to reveal the main differences in the crystalline structure of BDD and B:CNWs.
-
Determination of the effective concentration of ketoprofen against the germination of Sorghum bicolor (sorghum) seeds
Open Research DataResearch data includes an attempt to determine the effective concentration of ketoprofen that inhibits germination of Sorghum bicolor (sorghum) seeds.
-
Determination of the effective concentration of oxyteracycline solutions on the inhibition of bioluminescence of Vibrio fischeri (Microtox)
Open Research DataIn this study an attempt was made to determine the effective concentration for oxytetracycline solutions on the inhibition of bioluminescence of Vibrio fischeri (Microtox).
-
Determination the method of free alcohol fermented beverage production based on roasted raw materials.
Open Research DataData set presents the results of monosaccharides and ethyl alcohol determination in samples of fermented cereal drink with increased health value based on barley malt and roasting of rye, chicory and beetroot, and with the addition of hops. The HPLC method with RID detector was used for determinations
-
Determination of changes in viscosity of hydrogel depending on shear rate (6.6 to 330 s-1).
Open Research DataThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 18 spindle and shear rates from 6.6 to 330 s-1.
-
Determination of changes in viscosity of hydrogel depending on shear rate (1.1 to 55 s-1).
Open Research DataThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindle and shear rates from 1.1 to 55 s-1.
-
Determination of changes in viscosity of refined oil depending on the temperature (19-96 Celsius degrees).
Open Research DataThe rheological characteristics of the refined oil were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 18 spindle and a shear rate of 52.8 s-1 in from temperature 19-96 °C.
-
Determination of changes in viscosity of hydrogel depending on shear rate (1.7 to 34 s-1).
Open Research DataThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 27 spindle and shear rates from 1.7 to 34 s-1.
-
Determination of mechanical properties of Ti13Nb13Zr cubes made with STL technology subjected to uniaxial compression
Open Research DataThe aim of the study was to determine the mechanical properties of Ti13Nb13Zr cubes made with STL technology (3D printing). The experiments were carried out on the Hung Ta universal test machine HT-2402. Cubes with the initial dimensions of 10x10x10 mm were subjected to compression by increasing force to over 80 kN. In various experiments, the angle...
-
Determination of changes in viscosity of poly(acrylic acid) PAA solutions depending on shear rate.
Open Research DataThe rheological characteristics of poly(acrylic acid) PAA solutions were based on viscosity measurements using a Brookfield viscometer, using LV SC4 - 27 spindles and shear rates from 1,7 to 39 s-1 (Fig. 1). PAA solutions with were prepared in water. The data allowed to characterize the used PAA and assess their functional parameters as rheology modifying...
-
Determination of the total number of microorganisms in a model food product preserved by CS-2a and CS-2b.
Open Research DataThe dataset contains the results of determination of the total number of microorganisms in a model food product after the use of the innovative preservatives: CS-2a and CS-2b and control (K) after seven days of refrigerated storage of the product. The test was performed using the surface inoculation method.
-
Determination of the minimum inhibitory concentration of C-1305 derivatives (IKE1-IKE8) against Candida strains
Open Research DataThe datasets contain the results of determining the minimum inhibitory concentration of acridone derivatives against C. albicans ATCC 10231, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019 by the modified M27-A3 specified by the CLSI.
-
Determination of the minimum inhibitory concentration of C-1330 derivatives (IKE9-IKE14) against Candida strains
Open Research DataThe datasets contain the results of determining the minimum inhibitory concentration of C-1330 derivatives (IKE9-IKE14) against C. albicans ATCC 10231, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019 by the modified M27-A3 specified by the CLSI.
-
Determination of changes in viscosity of pectin gel depending on shear rate (1.1 to 55 s-1).
Open Research DataThe rheological characteristic of pectin gel (with concetration 0,45% m/m, in three independent repetition of sample) was made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindle and shear rates from 1.1 to 55 s-1.The data allowed to characterize the used hydrogel preparations and assess their functional...
-
Determination of changes in viscosity of pectin gel depending on shear rate (1.7 to 85 s-1).
Open Research DataThe rheological characteristic of pectin gel (with concetration 0,25% m/m, in two independent repetitions) wasmade on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 27 spindle and shear rates from 1.7 to 85 s-1, in temperature of 25 C degee .The data allowed to characterize the used hydrogel preparations and assess...
-
Determination of the minimum inhibitory concentration of new bisacridines IKE15-19 and IKE21, against yeast strains
Open Research DataThe datasets contain the results of determining the minimum inhibitory concentration of new bisacridines against C. albicans ATCC 10231, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019, S. cerevisiae ATCC 9763 and fluconazole resistant C. albicans strains by the modified M27-A3 specified by the CLSI.
-
This dataset contains results of our investigation aiming in determination of antioxidant potential of the propolis extract produced in our laboratory.
Open Research DataThis dataset contains results of our investigation aiming in determination of antioxidant potential of the propolis extract produced in our laboratory. The propolis samples were delivered by Polish beekeepers. DPPH and FREAP methods were used. Moreover, total phenolic contents in the extracts were determined.
-
The PolarScreen™ Estrogen Receptor Competitor Assays for determination of estradiol equivalent concentrations (EEQs) in sewage and drinking water samples.
Open Research DataMunicipal waste waters are one of the main sources of estrogenic compounds in aquatic environments. Feminization of fish downstream of Waste Water Treatment Plants (WWTPs) discharges has been observed worldwide. Some estrogenic chemicals, particularly steroid estrogens, are known to cause disruption of the endocrine system of fishes and abnormalities...
-
Determination of changes in viscosity of high-fructose syrup stability of pectin hydrogels depending on the temperature (25-96 Celsius degrees).
Open Research DataThe rheological characteristics of the high-fructose syrup modified stability of pectin (added in a concentration 2% m/m) were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 25 spindle and a shear rate of 0,22 s-1 in the temperature range 25-96 ° C. The data allowed selection of optimal conditions for the...
-
Determination of the MIC (minimum inhibitory concentration) of new bisacridines IKE16-19, IKE21 and IE10 against C. glabrata clinical strains
Open Research DataThe datasets contain the results of determining the MIC value (minimum inhibitory concentration) of new bisacridines IKE16-19, IKE21 and IE10 against Candida glabrata clinical strains CZD 310, 373, 377, 513 and collection strain DSM 11226 by the modified M27-A3 specified by the CLSI.
-
Determination of flow properties of a pneumatic hose from changes in air pressure in a tank being emptied or filled by a differently configured pneumatic line
Open Research DataThe aim of the study was to determine the flow properties of various pneumatic hoses. The experiments were to measure the pressure changes in a being filled or emptied tank for a differently configured pneumatic line, including pneumatic hoses of different length and diameter. Three test configurations were used: (1) pressure source -> pneumatic...
-
Minimum inhibitory concentrations (MICs) determination of selected human topoisomerase II alpha and bacterial DNA gyrase inhibitors against fungal strains
Open Research DataThe datasets contain the results of determining the MIC (Minimal Inhibitory Concentration) value of known compounds* (inhibitors of human topoisomerase II alpha and bacterial DNA gyrase) against C. albicans SC5314, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019 and Saccharomyces cerevisiae ATCC 9763 by the modified M27-A3...
-
Determination of the minimum inhibitory concentration of C-1311 derivatives (C-1296, C-1410, Compound 1, Compound 1-R8) against Candida strains
Open Research DataThe datasets contain the results of determining the minimum inhibitory concentration of imidazoacridinone derivatives against C. albicans ATCC 10231, C. glabrata ATCC 90030, C. krusei ATCC 6258 and C. parapsilosis ATCC 22019 and C. albicans clinical strains by the modified M27-A3 specified by the CLSI.
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.7, b=0.32) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.1, b=0.14) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=7.3, b=0.49) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.8, b=0.25) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=5.5, b=0.37) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=6.4, b=0.45) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=6.2, b=0.38) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.4, b=0.26) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve with (C=3.3, b=0.40) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient...
-
Determination of flow properties of a serial connection of a directional control valve with (C=2.0, b=0.11) and a air blow gun from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a air blow gun (with nozzle removed) arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.2, b=0.38) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=3.3, b=0.40) and a silencer (C=3.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=6.4, b=0.45) and a silencer (C=7.0) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.0, b=0.11) and a silencer (C=3.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a directional control valve (C=2.4, b=0.26) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a directional control valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> DCV -> ambient atmosphere, (2) pressure...
-
Determination of flow properties of a serial connection of a pressure relief valve (C=4.4, b=0.42) and a silencer (C=1.4) from changes in air pressure in a tank being emptied
Open Research DataThe aim of the study was to determine the flow properties of serial connection of pneumatic components.The experiments were to measure the pressure changes in a being emptied tank for a pressure relief valve and a silencer arranged in-line. Three test configurations were used: (1) being emptied tank -> PRV -> ambient atmosphere, (2) pressure source...