Filters
total: 3328
filtered: 2190
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: solid contact electrodes
-
Potentiometric sensor with lipid-polymer membranes for quality assessment of French red wines
PublicationThe quality of wines resulting from vineyard management is important for consumers due to the taste and price of wines. In this work, the quality of red wines of three vintages has been investigated by potentiometric sensors with six all-solid-state electrodes. Two series of experiments were carried out. The first involved a qualitative analysis of wine of different vintages from freshly opened bottles. The second consisted of...
-
Badania stabilności chemicznej kompozytowego elektrolitu 3-YSZ-Al2O3 w stosunku do materiałów elektrodowych do zastosowania w średniotemperaturowych ogniwach paliwowych
PublicationJednym z podstawowych wymogów stawianych mate- riałom na elektrolity do średniotemperaturowych ogniw paliwowych IT-SOFC (ang. intermediate-temperature solid oxide fuel cells) jest ich kompatybilność chemiczna z elektrodami w temperaturach zarówno eksploatacji, jak i wytwarzania ogniw. W celu sprawdzenia, czy badany w pracy kompozytowy elektrolit o osnowie z częściowo stabilizowanego ditlenku cyrkonu i z wtrąceniami tlenku glinu...
-
Effect of the welding environment and storage time of electrodes on the diffusible hydrogen content in deposited metal
PublicationIn the study the glycerin displacement method was used for determination of diffusible hydrogen content in deposited metal. Specimens were welded in the air and in the water with covered rutile electrodes. The first part of the specimens was made immediately after opening the package of the electrodes. The electrodes were then stored in opened packages in laboratory conditions that allowed for contact with the air for three years....
-
The Influence of Thin Gold Electrodes on the High-Temperature Impedance of Oxide Glasses
PublicationThe influence of thin gold electrodes on the electrical measurements of glasses at high temperatures was studied using impedance spectroscopy. The impedance was measured several times over a wide frequency range from 10 mHz to 1 MHz and the temperature ranged from 213 to 673 K under air and nitrogen atmospheres. The results showed a drop in the conductivity of more than an order of magnitude at a temperature around 603 K during...
-
Multifrequency Nanoscale Impedance Microscopy (m-NIM): A novel approach towards detection of selective and subtle modifications on the surface of polycrystalline boron-doped diamond electrodes
PublicationIn this paper, we describe the modification of Nanoscale Impedance Microscopy (NIM), namely, a combination of contact-mode atomic force microscopy with local impedance measurements. The postulated approach is based on the application of multifrequency voltage perturbation instead of standard frequency-by-frequency analysis, which among others offers more time-efficient and accurate determination of the resultant impedance spectra...
-
Oznaczanie tlenu – od metody Winklera do czujników enzymatycznych (Determination of oxygen – from Winkler Method to enzymatic sensor)
PublicationMonitoring of dioxygen levels is of utmost importance from the view-point of life processes, medical diagnostics, nutrition and chemical industries. In all these measurements both low and high levels of this element are important. The common methods for the determination of dioxygen are the Winkler method, Clark electrode and pulsoxymeters. A new, already strong field of research can be now recognized – the development of miniaturized...
-
Tuning of the Electrochemical Properties of Transparent Fluorine-doped Tin Oxide Electrodes by Microwave Pulsed-plasma Polymerized Allylamine
PublicationWe report here the dry, one-step, and low-temperature modification of FTO surfaces using pulsed plasma polymerization of allylamine (PPAAm). PPAAm/FTO surfaces were characterized by X-ray photoelectron spectroscopy, spectroscopic ellipsometry, and contact angles to understand the morphological, structural, and optical properties. FTO were coated with a very thin layer of adherent cross-linked, pinhole-, and additive-free allylamine...
-
Electrochemical behavior of a composite material containing 3D-structured diatom biosilica
Publication3D-structured diatom biosilica mixed with conducting carbon black was investigated as an active electrode material for lithium-ion batteries. Diatom biosilica was obtained by cultivation of the selected diatom species under laboratory conditions. Several instrumental techniques (XRD, FTIR, Raman, SEM-EDX, TGA) were used to characterize the physicochemical properties of applied biosilica. It was evidenced that the prepared new composite...
-
Electrochemical oxidation of landfill leachate using boron-doped diamond anodes: pollution degradation rate, energy efficiency and toxicity assessment
PublicationElectrochemical oxidation (EO), due to high efficiency and small carbon footprint, is regarded as an attractive option for on-site treatment of highly contaminated wastewater. This work shows the effectiveness of EO using three boron-doped diamond electrodes (BDDs) in sustainable management of landfill leachate (LL). The effect of the applied current density (25–100 mA cm−2) and boron doping concentration (B/C ratio: 500 ppm, 10,000...
-
Behavioral state classification in epileptic brain using intracranial electrophysiology
PublicationOBJECTIVE: Automated behavioral state classification can benefit next generation implantable epilepsy devices. In this study we explored the feasibility of automated awake (AW) and slow wave sleep (SWS) classification using wide bandwidth intracranial EEG (iEEG) in patients undergoing evaluation for epilepsy surgery. APPROACH: Data from seven patients (age [Formula: see text], 4 women) who underwent intracranial depth electrode...
-
Assessment of organic coating degradation via local impedance imaging
PublicationThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...
-
A Flexible Nafion Coated Enzyme‐free Glucose Sensor Based on Au‐dimpled Ti Structures
PublicationThe detection of glucose at low concentrations using electrochemical sensors is of great importance due to the possibility of using different human body fluids than blood, such as e.g. urine, saliva, sweat or tears. The interest behind those biofluids is related to their utility in non-invasive sugar determination. In this work, we present flexible, fully biocompatible electrode material based on Au nanoparticles immobilized onto...
-
Non-standard contact conditions in generalized continua: microblock contact model for a Cosserat body
PublicationGeneralized continuum theories involve non-standard boundary conditions that are associated with the additional kinematic variables introduced in those theories, e.g., higher gradients of the displacement field or additional kinematic degrees of freedom. Accordingly, formulation of a contact problem for such a continuum necessarily requires that adequate contact conditions are formulated for the additional kinematic variables and/or...
-
Enhanced photoelectrochemical and photocatalytic performance of iodine-doped titania nanotube arrays
PublicationThe paper discusses the synthesis and performance of iodine doped titania nanotube arrays exhibited under irradiation. The doping procedure was performed as an additional, electrochemical process carried out after formation of nanotube arrays via anodization of Ti substrate. The optical and structural properties were characterized using Raman, UV-vis, photoluminescence and X-ray photoelectron spectroscopy. The surface morphology...
-
The new version of contact-less method for localisation of catenary contact wire – theoretical assumption
PublicationThis article presents the theoretical basic of a new version of contact-less method for localising the catenary contact wires, using the advanced video techniques and image analysis. So far, contact line diagnostic systems exploited nowadays uses the contact measuring methods with special design current collector. This solutions make it impossible to measure the contact line geometry in a static way. The proposed measurement method...
-
Hybrid electrode materials for fast performance devices
PublicationEnergy storage devices such as Electrochemical Double Layer Capacitors and other types of the electrochemical capacitors require chemically stable, non-soluble, electrochemically active electrode materials compatible with appropriate electrolytes. Factors which determine their applicability are derived from so called electrochemical window of electroltes, nature of charge accumulation and their kinetics. On the other hand technological...
-
Estimation of electrode contact in capacitive ECG measurement
PublicationIn the paper a method of electrode’s contact estimation in capacitive electrocardiogram (CECG) is presented. Proposed solution allows estimation of contact quality for each individual electrode. This enables construction of multi-electrode CECG systems, where electrode pairs can be selected on the basis of the individual electrode contact quality.
-
Analysis of Ceramic Elements with Ring-Crack Defects in Lubricated Rolling Contact
PublicationThe properties of ceramics, specifically low density, high hardness, high temperature capability and low coefficient of thermal expansion are of most interest to rolling element manufacturers. Surface ring cracks on lubricating rolling contact fatigue failure has been studied using numerical fracture analysis. Such cracks are very often found on ceramic bearing balls and decrease fatigue life rapidly. The numerical calculations...
-
Performance of lubricated sliding contact in magnetic field
PublicationResults of experimental studies concerning theinfluence of permanent magnetic field on wear of lubricatedsliding contact operating at short stroke and highfrequency are presented. It was found that horizontalmagnetic is affecting performance of the contact. Thejagged delamination regions produced in the presence of amagnetic field can be regarded as easily undergoing oxidisationbecause oxygen is readily adsorbed there. Magneticfield...
-
3D scanning system for railway current collector contact strips
PublicationUndisturbed collection of current from a contact wire of the catenary constitutes one of the basic elements in reliable operation of electrified rail transport, particularly when vehicles move at high speed. Quality of current collection is influenced by the construction of catenary and current collectors, as well as by the technical condition and regulation of these two elements. Total contact force of a current collector head...
-
Visual method for detecting critical damage in railway contact strips
PublicationEnsuring an uninterrupted supply of power in the electric traction is vital for the safety of this important transport system. For this purpose, monitoring and diagnostics of the technical condition of the vehicle's power supply elements are becoming increasingly common. This paper presents a new visual method for detecting contact strip damage, based on measurement and analysis of the movement of the overhead contact line (OCL)...
-
Electrohydrodynamic secondary flow in the electrostatic precipitator with spiked electrodes
PublicationIn this work, the results of electrohydrodynamic (EHD) secondary flow measurements in an electrostatic precipitator (ESP) with one-sidedspike electrodes are presented. The EHD secondary flow was measured for one-sided spike electrodes with the spike tips directed either upstream or downstream the primary flow. The results showed different flow patterns for different spike tips direction in respect to the primary flow direction....
-
Non-Contact Temperature Measurements Dataset
PublicationThe dataset titled The influence of the distance of the pyrometer from the surface of the radiating object on the accuracy of measurements contains temperature measurements using a selection of four commercially available pyrometers (CHY 314P, TM-F03B, TFA 31.1125 and AB-8855) as a function of the measuring distance. The dataset allows a comparison of the accuracy and measuring precision of the devices, which are very important...
-
Local Structure and Stability of SEI in Graphite and ZFO Electrodes Probed by As K-edge Absorption Spectroscopy
PublicationThe evolution of the solid electrolyte interphase (SEI) during the first Li uptake in advanced Li-ion electrodes is studied by X-ray absorption spectroscopy (XAS). The As atoms present in the electrolyte solution were used as a local probe for monitoring the SEI growth on different electrodes. High-quality As K-edge spectra were collected in fluorescence mode for a set of graphite and carbon-coated ZnFe2O4 electrodes. XAS measurements...
-
Determination of binder-aggregate adhesion by contact angle measurement
PublicationThe key factor in asphalt pavement durability, especially in the presence of water, is adhesion of the bituminous binder to mineral aggregates. There are currently no standard laboratory test procedures that can quickly and accurately measure the strength of the interaction (bond) between the binder and aggregate. In this regard, to evaluate the adhesion force measurements based on the contact angle between the binder and the aggregate...
-
Robustness of contact-less optical method, used for measuring contact wire position in changeable lighting conditions
PublicationThe article presents verification of robustness of contactless method based on 2D image camera, which is used to measure catenary contact wire position in changeable ambient lighting conditions. Robustness in changeable lighting conditions is ensured through the combination of advanced image processing for background information removal and the algorithm of error correction. This algorithm detects incorrect images and substitutes...
-
SEI Growth and Depth Profiling on ZFO Electrodes by Soft X-Ray Absorption Spectroscopy
PublicationZnFe2O4 (ZFO) Li-ion batteries (LIBs) represent a reliable, affordable, and safe energy storage technology for use in portable application. However, current LIB active materials (graphite, lithium/transition metal spinel or layered oxides, olivine structures) can store only limited energy since they rely on insertion storage based on solid-state host-guest interactions. Moreover, performances and durability of the cells are strongly...
-
Comparison of EHD devices with parallel and in series spiked electrodes
PublicationIn this paper two electrohydrodynamic (EHD) devices for gas pumping and cleaning are presented. In both cases to induce an airflow in these EHD devices corona discharge was used. The discharge was generated between the spiked electrodes set parallel (the first case) or in series (the second case) and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device....
-
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublicationThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
Electrodes criticality: the impact of CRMs in the leachate electrochemical oxidation
Publication. Landfill leachate possesses high concentrations of ammonia, micropollutants, and heavy metals, and are characterised for low biodegradability. For this reason, conventional treatment technologies may result ineffective for complete pollutant removal. Electrochemical oxidation allows most of the of recalcitrant pollutants to be oxidised effectively within an easy operational and acceptable retention time, without the need to provide...
-
Is the Solid Electrolyte Interphase an Extra-Charge Reservoir in Li-Ion Batteries?
PublicationAdvanced metal oxide electrodes in Li-ion batteries usually show reversible capacities exceeding the theoretically expected ones. Despite many studies and tentative interpretations, the origin of this extra-capacity is not assessed yet. Lithium storage can be increased through different chemical processes developing in the electrodes during charging cycles. The solid electrolyte interface (SEI), formed already during the first...
-
Experimental verification of visual method for measuring displacements of contact line elements
PublicationThe increase of rail vehicles speed, as well as the increase of their power, puts high demands on the power delivery system for traction vehicles The most critical point in the vehicle's power supply circuit is the contact between the current collector and contact wires. Ensuring a reliable co-operation of the current collector and contact line, requires technical development...
-
Study of Metrological Properties of Voltammetric Electrodes in the Time Domain
PublicationMetrological properties of voltammetric electrodes, in the situation where on their surface an electrochemical reaction of oxidizing/reduction takes place, were analyzed in this chapter. The properties of electrodes on which a reaction controlled by ion transport process takes place were taken into consideration. Also, it was analyzed how the electrode’s shape and the voltage polarizing the electrode influence this electrode’s...
-
Assessment of hydrogenation of deposited metal of P 62 MR covered electrodes
PublicationThe determination of diffusible hydrogen content in deposited metal of P 62 MR covered electrodes for manual metal arc welding by mercury method was carried out. The test results indicate that covered electrodes 62 P MR grade generate a mean of 4.02 ml/100g of diffusible hydrogen in deposited metal, which is consistent with H5 class.
-
Composites of tin oxide and different carbonaceous materials as negative electrodes in lithium-ion batteries
PublicationAbstract Tin and tin oxide have been considered as suitable materials with high theoretical capacity for lithium ion batteries. Their low cost, high safety and other technical benefits placed them as promising replacements for graphite negative electrodes. The problem to overcome with tin oxide, as well as with other metallic materials, is high volume changes during alloying/dealloying, subsequent pulverization, delamination from...
-
N-doped carbon materials as electrodes for highly stable supercapacitors
PublicationThis article reports a strategy to use nitrogen-doped carbon materials as electrodes for supercapacitors. Depending on the carbon precursor, the porous structure is changed with specific surface area reached up to 2270 m2 g−1. The capacitance of carbon materials used as electrodes is related strictly to pore size. The microstructure and nitrogen functionalities enable a high capacitance (327 F g−1) and cycle durability. The nanoporous...
-
Tribological performance of PTFE-metal binary coatings in rolling/sliding contact
PublicationTribological performance of surface coatings with embedded PTFE reservoirs in rolling/sliding contact is reported. Using two different coating materials and two shapes and patterns of PTFE reservoirs test samples in the form of discs were prepared and tested in a four-ball contact configuration under loads corresponding to nominal contact pressure of 0.5 and 1.0 GPa. It was found that one coating, namely aluminium-bronze with embedded...
-
Contact with coupled adhesion and friction: Computational framework, applications, and new insights
PublicationContact involving soft materials often combines dry adhesion, sliding friction, and large deformations. At the local level, these three aspects are rarely captured simultaneously, but included in the theoretical models by Mergel et al., (2019). We here develop a corresponding finite element framework that captures 3D finite-strain contact of two deformable bodies. This framework is suitable to investigate sliding friction even...
-
A chemo-mechano-thermodynamical contact theory for adhesion, friction, and (de)bonding reactions
PublicationThis work presents a self-contained continuum formulation for coupled chemical, mechanical, and thermal contact interactions. The formulation is very general and, hence, admits arbitrary geometry, deformation, and material behavior. All model equations are derived rigorously from the balance laws of mass, momentum, energy, and entropy in the framework of irreversible thermodynamics, thus exposing all the coupling present in the...
-
Development of iron doped strontium titanates as oxygen electrode for solid oxide fuel cells
PublicationProducing efficient solid oxide fuel cells (SOFC) without the use of harmful elements is one of the current challenges. Increasing the safety of people and reducing production costs is possible, among others, thanks to the use of iron doped strontium titanates as porous oxygen electrodes. In this thesis, the results of research on iron doped strontium titanates as potential oxygen electrodes for SOFC are presented. The research...
-
High load capacity spur gears with conchoidal path of contact
PublicationThe present study is devoted to investigation of spur gears with a conchoidal path of contact and a convex-convex contact between teeth. The load capacity and energy efficiency were evaluated using both theoretical and experimental approaches. The theoretical analysis showed that the conchoidal gear pairs are 5–21% stronger in terms of contact stress and have similar energy efficiency as compared to the involute gear pairs of the...
-
Determination of moisture resistance of covered electrodes according to PN-EN ISO 14372
PublicationMoisture present in the electrode covering is one of the sources of diffusible hydrogen in welded joints. In order to study the diffusible hydrogen content in deposited metal, a stand for moisturizing covered electrodes, in accordance with the PN-EN ISO 14372 standard, was built. After the stand was completed, a test of moisturizing the electrodes was carried out and measurements of the diffusible hydrogen content in deposited...
-
Wavelet transform-based approach to defect identification in railway carbon contact strips.
PublicationPantographs of electric rail vehicles are fitted with carbon contact strips, which slide along the contact wire of catenary to provide constant electrical contact. Contact strips are exposed to wear and damages. Using damaged contact strips significantly increases the risk of catenary rupture. Therefore, their technical condition has to be inspected frequently. In previous work a 3D laser scanning system was proposed for recording...
-
On topology optimization of large deformation contact-aided shape morphing compliant mechanisms
PublicationA topology optimization approach for designing large deformation contact-aided shape morphing compliant mechanisms is presented. Such mechanisms can be used in varying operating conditions. Design domains are described by regular hexagonal elements. Negative circular masks are employed to perform dual task, i.e., to decide material states of each element and also, to generate rigid contact surfaces. Each mask is characterized by...
-
INFLUENCE OF SURFACE CURVATURE ON SESSILE DROPLET CONTACT ANGLE OF NANOFLUIDS
PublicationThis paper deals with change in contact angle of droplets of three nanofluids, i.e. water-Al2O3, water-TiO2 and water-Cu. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. Although dispersants were not used to stabilize the suspension, the solutions tested exhibited satisfactory stability. Ultrasonic vibration was used in order to stabilise the dispersion of the nanoparticles. Experimental measurements...
-
Solid Oxide Fuel Cells with Ni infiltrated perovskite anode
PublicationNiobium-doped strontium titanate was used as the anode for a solid oxide fuel cell. Electrolyte-supported cells were prepared with pure perovskite and composite perovskite–yttria–stabilized-zirconia (YSZ) anodes. Fuel cell tests demonstrated significant improvement in power density after infiltration with a small amount of Ni. The obtained values of power densities are comparable with conventional Ni/YSZ cermet anode. In addition,...
-
Perfect thermal contact of hyperbolic conduction semispaces with an interfacial heat source
PublicationThe problem of thermal contact between two bodies with a heat source at their interface presents great scientific and practical interest. On the time scale of a nanosecond or shorter, heat propagation should be considered in the form of thermal waves of finite speeds. This study investigated the thermal behaviour of hyperbolic conduction semispaces in perfect thermal contact subjected to the action of an interfacial heat source....
-
An isogeometric finite element formulation for frictionless contact of Cosserat rods with unconstrained directors
PublicationThis paper presents an isogeometric finite element formulation for nonlinear beams with impenetrability constraints, based on the kinematics of Cosserat rods with unconstrained directors. The beam cross-sectional deformation is represented by director vectors of an arbitrary order. For the frictionless lateral beam-to-beam contact, a surface-to-surface contact algorithm combined with an active set strategy and a penalty method...
-
Mathematical modelling of the overhead contact line for the purpose of diagnostics of pantographs
PublicationThe overhead contact line (OCL) is the most effective way for supplying railway electric vehicles. The increase of the speed of the vehicles increases power consumption and requires ensuring proper cooperation of pantographs with OCL. The paper describes the novel mathematical model of the OCL system and the simulation results. The primary objective is a more accurate analysis to increase the reliability of the evaluation of monitoring...
-
Algorithm for Automatic Wear Estimation of Railway Contact Strips Based on 3D Scanning Results
PublicationElectric rail vehicles use current collection system which consists of overhead contact line and a current collector (pantograph) mounted on the roof of a vehicle. A pantograph is equipped with contact strips, which slide along the contact wire, ensuring steady electric contact. Contact strips are made of carbon layer, fixed to an aluminum carrier. The carbon layer wears down due to friction. Using overly worn contact strips increases...