Search results for: BLOOD PRESSURE, PULSE TRANSIT TIME, NONINVASIVE MEASUREMENTS, SAMPLING FREQUENCY, LOW PASS FILTER
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublicationNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
RESPONSE TO ORTHOSTATIC STRESS PREDICTS OFFICE‐DAYTIME BLOOD PRESSURE DIFFERENCE, BUT NOT NOCTURNAL BLOOD PRESSURE FALL IN MILD ESSENTIAL HYPERTENSIVES: RESULTS OF THE HARVEST TRIAL
Publication -
FIR Filter Design Using Distributed Maximal Flatness Method
PublicationIn the paper a novel method for filter design based on the distributed maximal flatness method is presented. The proposed approach is based on the method used to design the most common FIR fractional delay filter - the maximally flat filter. The MF filter demonstrates excellent performance but only in a relatively narrow frequency range around zero frequency but its magnitude response is no greater than one. This ,,passiveness”...
-
Differentiating patients with obstructive sleep apnea from healthy controls based on heart rate-blood pressure coupling quantified by entropy-based indices
PublicationWe introduce an entropy-based classification method for pairs of sequences (ECPS) for quantifying mutual dependencies in heart rate and beat-to-beat blood pressure recordings. The purpose of the method is to build a classifier for data in which each item consists of two intertwined data series taken for each subject. The method is based on ordinal patterns and uses entropy-like indices. Machine learning is used to select a subset...
-
Ambulatory blood pressure and long-term risk for atrial fibrillation
Publication -
Take a Blood Pressure Pill or Benefit from Renal Denervation?
Publication -
Association of Office and Ambulatory Blood Pressure With Mortality and Cardiovascular Outcomes
Publication -
Effects of obstructive sleep apnea on endothelin-1 and blood pressure
Publication -
Issues in the development of new combinations of blood pressure lowering drugs
Publication -
Measurements of the Hydraulic Fluids Compressibility
PublicationPerformance of the hydrostatic high-pressure drive systems is affected by the changes of working fluid’s volume. Presence of air bubbles in the fluid cause this problem to be even more serious. To study this phenomenon precise measurements of fluid’s bulk modulus are necessary. Differ-ent measurement methods are applied, but they are either limited to low pressure range or give inaccurate results. To solve the problem the new...
-
Pulse-Modulated Radio-Frequency Alternating-Current-Driven Atmospheric-Pressure Glow Discharge for Continuous-Flow Synthesis of Silver Nanoparticles and Evaluation of Their Cytotoxicity toward Human Melanoma Cells
Publication -
Absorption spectroscopy setup for determination of whole human blood and blood–derived materials spectral characteristics
PublicationA dedicated absorption spectroscopy system was set up using tungsten-halogen broadband source, optical fibers, sample holder, and a commercial spectrometer with CCD array. Analysis of noise present in the setup was carried out. Data processing was applied to the absorption spectra to reduce spectral noise, and improve the quality of the spectra and to remove the baseline level. The absorption spectra were measured for whole blood...
-
Intensive blood pressure lowering prevents mild cognitive impairment and possible dementia and slows development of white matter lesions in brain: the SPRINT Memory and Cognition IN Decreased Hypertension (SPRINT MIND) study
Publication -
Square root RC Nyquist filter of fractional delay
PublicationIn this paper we propose a discrete-time FIR (finite impulse response) filter which couples the role of square root Nyquist filter with fractional delay filter. This filter enables to substitute for a cascade of square root RC (SRRC) Nyquist filter and fractional delay filter in one device/algorithm. The aim is to compensate for transmission delay in communication system. Statistically defined performances, e.g. BER (bit error...
-
Low-temperature high-pressure cryogelation of nanooxides
Publication -
Influence of PWHT Parameters on the Mechanical Properties and Microstructural Behavior of Multi-Pass GTAW Joints of P92 Steel
PublicationThe 9% Cr steels were developed for ultra-supercritical (USC) power plants to meet the requirements of high operating temperature and pressure. These steels are produced to operate at high temperatures where impact toughness is not a concern; however, it becomes important for the welded joints to have good impact toughness at room temperature for manufacturing. The present work investigates the effect of the post-weld heat treatment...
-
Frequency Guided Generalized Adaptive Notch Filtering - Tracking Analysis and Optimization
PublicationGeneralized adaptive notch filters (GANFs) are estimators of coefficients of quasi-periodically time-varying systems, encountered e.g., in RF applications when Doppler effect takes place. Current state of the art GANFs can deliver highly accurate estimates of system variations’ frequency, but underperform in terms of accuracy of system coefficient estimates. The paper proposes a novel multistage GANF with improved coefficient...
-
Measurements of flicker noise in supercapacitor cells
PublicationFlicker noise (1/f-like noise) is often used to assess the quality of various materials and devices. This phenomenon has been observed in different electrochemical devices or reactions (e.g., smart windows, pitting corrosion events). In our exploratory studies we consider how to measure and utilize 1/f noise for the quality assessment of supercapacitors. This task requires special attention because of enormous capacitance of the...
-
Low-Level Aerial Photogrammetry as a Source of Supplementary Data for ALS Measurements
PublicationThe development of laser scanning technology ALS allows to make high-resolution measurements for large areas result-ing in significant reduction of costs. The main stakeholders at heights data received from the airborne laser scanning is mainly state administration. The state institutions appear among projects such as ISOK. Each point is classified in ac-cordance with the standard LAS 1.2, our research focuses on the class 6 -...
-
Accuracy of a low-cost autonomous hexacopter platforms navigation module for a photogrammetric and environmental measurements
PublicationA photogrammetry and environmental measurements from an unmanned aerial vehicle (UAV) are a low-cost alternative for a traditional aerial photogrammetry. A commercial off-the-shelf products (COTS) offers a variety of cheap components that a suitable to be used on board a UAV. In this paper a low-cost navigation module based on Ublox NEO-M8N GPS and Pixhawk flight controller have been described, as a main extrinsic parameters source...
-
A convergence result for mountain pass periodic solutions of perturbed Hamiltonian systems
PublicationIn this work, we study second-order Hamiltonian systems under small perturbations. We assume that the main term of the system has a mountain pass structure, but do not suppose any condition on the perturbation. We prove the existence of a periodic solution. Moreover, we show that periodic solutions of perturbed systems converge to periodic solutions of the unperturbed systems if the perturbation tends to zero. The assumption on...
-
Electromagnetic Field Measurements of Bow Thruster Drive with Frequency Converter
Publication -
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publication -
Evaluation of Facial Pulse Signals Using Deep Neural Net Models
PublicationThe reliable measurement of the pulse rate using remote photoplethysmography (PPG) is very important for many medical applications. In this paper we present how deep neural networks (DNNs) models can be used in the problem of PPG signal classification and pulse rate estimation. In particular, we show that the DNN-based classification results correspond to parameters describing the PPG signals (e.g. peak energy in the frequency...
-
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publication -
Supply system based on the 18-pulse diode rectifier with coupled reactors and integrated with the series active power filter
Publication -
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublicationLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
An update on medium- and low-abundant blood plasma proteome of horse
Publication -
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Raman spectroscopic investigation of blood and related materials
PublicationThis paper reports preliminary studies on use of Raman spectroscopy for investigation of blood. High quality blood spectra were recorded in-vitro with excitation wavelengths of 830 nm. Because of complex composition of the blood as well as by light attenuation and scattering in the tissues, spectra set up from wide, low-intensive Raman bands and intensive optical background. To get information about origin of bands in Raman spectra...
-
The Effect of Herbal Supplements on Blood Pressure: Systematic Review and Meta-Analysis
Publication -
The SPRINT study: Outcome may be driven by difference in diuretic treatment demasking heart failure and study design may support systolic blood pressure target below 140 mmHg rather than below 120 mmHg
Publication -
Augmentation index, pulse pressure amplification and superoxide anion production in patients with coronary artery disease
Publication -
Passive sampling and/or extraction techniques in environmental analysis: a review
PublicationThe current state-of-the-art of passive sampling and/or extraction methods for long-term monitoring of pollutants in different environmental compartments is discussed in this review. Passive dosimeters that have been successfully used to monitor organic and inorganic contaminants in air, water, sediments, and soil are presented. The application of new approaches to the determination of pollutants at the sampling stage is discussed....
-
Dual-Polarized Wideband Bandpass Metasurface-Based Filter
PublicationThis paper presents a novel metasurface-based bandpass filter. The structure is realized by simply patterning a double-sided AD250 substrate, and does not require any vias or insertion of lumped elements. The top layer is an annular- aperture-array with multiple inner conductors, whereas the bottom layer is a first-order Hilbert-curve array. FEM-based simulation results of the filter are obtained using HFSS. The experimental validation...
-
Low-Cost Open-Hardware System for Measurements of Antenna Far-Field Characteristics in Non-Anechoic Environments
PublicationExperimental validation belongs to the most important steps in the development of antenna structures. Measurements are normally performed in expensive, dedicated facilities such as anechoic chambers, or open-test sites. A high cost of their construction might not be justified when the main goal of antenna verification boils down to demonstration of the measurement procedure, or rough validation of the simulation models used for...
-
Discrete-continuous optimisation of an axial flow blood pump
PublicationThis paper presents results of discrete-continuous optimisation of an axial flow blood pump. Evolution Strategies (ES) are used as a global optimisation method in order to localise the optimal solution in relatively short time. The whole optimisation process is fully automated. This also applies to geometry modelling. Numerical simulations of the flow inside the pump is performed by means of the Reynolds-Average Navier-Stokes...
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Influence of the Adsorption Bed Composition on the Low-Pressure Fluidization
Publication -
Time-frequency characteristics of chemical oscillations. Experimental and model studies.
PublicationW publikacji zaprezentowano wykorzystanie czasowo-częstotliwościowych metod analizy sygnałów niestacjonarnych do badania reakcji Biełousowa-Żabotyńskiego. Zastosowanie krótkoczasowej transformaty Fouriera (STFT) pozwoliło na uzyskanie spektrogramów przedstawiających zmiany energii i częstotliwości oscylacji w trakcie trwania reakcji chemicznej. Przedyskutowano podobieństwa i różnice pomiędzy spektrogramami wygenerowanych dla eksperymentalnych...
-
Study on the time-frequency analysis of nonstationary, electrochemical and corrosion processes
PublicationW pracy przedstawiono możliwości zastosowania czasowo-częstotliwościowych metod analizy sygnałów do badania niestacjonarnych procesów elektrochemicznych, chemicznych i korozyjnych. Wnikliwej analizie z wykorzystaniem metod STFT, rozkładu Wignera-Ville'a oraz przekształceń z klasy Cohena poddano rejestry oscylacji chemicznych, elektrochemicznych i rejestry korozji wżerowej.
-
Methods of measurement signal acquisition from the rotational flow meter for frequency analysis
PublicationOne of the simplest and commonly used instruments for measuring the flow of homogeneous substances is the rotational flow meter. The main part of such a device is a rotor (vane or screw) rotating at a speed which is the function of the fluid or gas flow rate. A pulse signal with a frequency proportional to the speed of the rotor is obtained at the sensor output. For measurements in dynamic conditions, a variable interval between...
-
Effects of n-butanol presence, inlet loading, empty bed residence time and starvation periods on the performance of a biotrickling filter removing cyclohexane vapors from air
PublicationThis paper presents the results of investigations on the removal of cyclohexane vapors from air using a peat-perlite packed biotrickling filter. Effects of basic process parameters i.e. IL (inlet loading) and EBRT (empty bed residence time) as well as introduction of n-butanol to the treated air stream and starvation periods on the process performance were evaluated. The results show that the introduction of hydrophilic n-butanol...
-
Sounding rocket vibration mechanical filter and amplifier
PublicationMeasuring accelerations and vibrations of a sounding rocket provides both information for engineers on the launcher vehicle performance as well as environment description for future payload designers. Typically, information on the level of vibration and eigenfrequencies are required to properly design a payload. This paper presents a design of a novel mechanical filter and amplifier for mechanical vibrations. Its key feature is...
-
Directed electromagnetic pulse dynamics: projecting operators method
PublicationIn this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...
-
Discrete-time estimation of nonlinear continuous-time stochastic systems
PublicationIn this paper we consider the problem of state estimation of a dynamic system whose evolution is described by a nonlinear continuous-time stochastic model. We also assume that the system is observed by a sensor in discrete-time moments. To perform state estimation using uncertain discrete-time data, the system model needs to be discretized. We compare two methods of discretization. The first method uses the classical forward Euler...
-
Discrete-time estimation of nonlinear continuous-time stochastic systems
PublicationIn this paper we consider the problem of state estimation of a dynamic system whose evolution is described by a nonlinear continuous-time stochastic model. We also assume that the system is observed by a sensor in discrete-time moments. To perform state estimation using uncertain discrete-time data, the system model needs to be discretized. We compare two methods of discretization. The first method uses the classical forward Euler...
-
Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
PublicationThe aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development...
-
Programmable linearized CMOS OTA for fully differential continuous-time filter design
PublicationW artykule przedstawiono metodę linearyzacji wzmacniacza wykorzystującą sprzężenie w przód. Wzmacniacz składa się z par różnicowych i referencyjnego rezystora. W wyniku uzyskano skuteczną metodę linearyzacji charakterystyk przejściowych wzmacniacza. Programowalność wartości transkonduktancji wzmacniacza realizowana jest poprzez lustro prądowe. Wykonane symulacje komputerowe SPICE z użyciem modeli dla technologii 0.35um AMS CMOS...
-
Continuous-Time Active-RC Filter Model for Computer-Aided Design and Optimization
PublicationW pracy przedstawiono ogólny model filtru aktywnego RC opartego na wzmacniaczach odwracajacych faze. Model analizowany jest przy użyciu równań macierzowych. Podano jawną formułę określającą funkcję przenoszenia filtru w ogólnym przypadku. Przedstawiono rozszerzenia modelu pozwalające uwzgledniać nieidealność wzmacniaczy operacyjnych, w tym skończone wzmocnienie i pasmo przenoszenia oraz niezerową rezystancję wyjściową. Wyprowadzono...