displaying 1000 best results Help
Search results for: PHASE ANALYSIS
-
Morphology changes in Fe-Cr porous alloys upon high-temperature oxidation quantified by X-ray tomographic microscopy
PublicationThe effect of high-temperature oxidation at 850 C (10 h, 30 h, 100 h) and 900 C (10 h) on porous (30 % porosity) ferritic stainless steel (Fe22Cr) has been investigated using synchrotron tomographic microscopy, which allowed for visualisation, separation and quantitative analysis of the metallic core, closed pores, open pores and oxide scale phase. The same regions within the samples were investigated before and after oxidation...
-
A study on the protection of methionine and the reduction of methionine sulfoxide in methionine-containing analogues of the growth-modeling factor Gly-His-Lys
PublicationThe protection of methionine and the reduction of methionine sulfoxide in methionine-containing analogues of Gly-His-Lys are described. The peptides were synthesized by a solid-phase method using the standard Fmoc procedure. Simultaneous deprotection of the peptide side chain and liberation from the resin were achieved using an appropriate TFA cocktail. The TFA cocktail was selected to minimize oxidation of the methionine residue....
-
Ion Chromatography in Environmental Analysis of Selected Organic Acids
PublicationLow molecular mass carboxylic acids (LCAs) occur in many environmental compartments dueto natural processes and human activity. When volatile and nonvolatile acids are to be monitored then liquidchromatography, including ion chromatography seems a method of choice. At high pH the acids are inionized form and can be separated as carboxylats by means of anion exchange chromatography. LCAs canalso be separated at low pH by ion exclusion...
-
Application of modern sample-preparation techniques to the determination of chloropropanols in food samples
PublicationChloropropanols are heat-induced food toxicants that recently caused concern among industrial and scientific experts. World and European organizations related to food safety asked researchers to investigate mitigation strategies regarding these contaminants. The essential objective of this project was development of fast analytical methods enabling reliable determination and quantification of 3-monochloropropane-1,2-diol, 2-monochloropropane-1,3-diol...
-
JMATRIX - a package for relativistic J-matrix calculations in elastic scattering of electrons from model potentials
PublicationWe present a software package JMATRIX, consisting of two computer codes written in FORTRAN 95 and parallelized with OpenMP, implementing the so-called J-matrix method, applied to elastic scattering of electrons on the radial potential, vanishing faster than Coulomb one. In the J-matrix method, physical scattering problem is replaced by using well-defined model, which is solved analytically. Presented software implements both non-relativistic...
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublicationThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Building damage due to structural pounding during earthquakes
PublicationEarthquake-induced pounding between adjacent buildings has been identified as one of the reasons for substantial damage or even total collapse of colliding structures. A major reason leading to interactions in buildings results from the differences in their dynamic parameters and also from insufficient distance between the structures. Although the research on structural pounding has been much advanced, the studies have mainly been...
-
Analysis of features of stainless steels in dissimilar welded joints in chloride inducted corrosion
PublicationStainless steels of femtic-austenitic microstructure that means the duplex Cr-Ni-Mo steels, in comparison with austenitic steel includes less expensive nickel and has much better mechanical properties with good formability and corrosion resistance, even in environments containing chloride ions. Similar share of high chromium ferrite and austenite, which is characterized by high ductility, determines that the duplex steels have...
-
Nowe rozwiązania metodyczne i techniczne w zakresie techniki mikroekstrakcji do fazy stracjonarnej
PublicationSample preparation has been recognized as a critical step of the analytical process, being even considered as the bottleneck of the overall process. Enrichment of target compounds, transfer of the analytes into a solvent compatible with the analytical instrumentation, minimization of potential interferences, and efficient sample clean-up, are among the main aims of sample preparation techniques. In this regard, liquid-liquid extraction...
-
Tomasz Wąsowicz dr hab.
PeopleTomasz Wąsowicz's research was first related to high-resolution atomic spectroscopy and focused on measurements and analysis of the transition probabilities of the forbidden lines, the hyperfine and isotopic structure of spectral lines of heavy elements, Stark effect in the helium atom. Tomasz Wąsowicz currently studies physicochemical processes occurring during interactions of various forms of radiation with atoms and molecules...
-
An effective method for studying intermolecular interactions in binary liquids with hydrogen bonds: FTIR spectra and ab initio calculations in the N-methylformamide - methanol system
PublicationMolecular complexes in methanol (MeOH)−N-methylformamide (NMF) mixtures were studied based on their FTIR-ATR spectra, to which two methods of analysis were applied: factor analysis and a quantitative version of the difference-spectra method. The mean composition of a complex between NMF and MeOH molecules over the whole range of mixture compositions was determined. Absorbing species differentiated with regard to the interaction...
-
Transparent thin films of Cu-TiO2 with visible light photocatalytic acitivity
PublicationThin films of Cu–TiO2 with a high level of transparency were prepared by a dip-coating procedure on the glass surface. CuCl2 was used as a copper precursor added during sol – gel synthesis of TiO2. The extension of optical absorption into the visible region of as-prepared thin films was indicated by UV/Vis spectroscopy. Only the anatase phase was detected by X-ray di ffraction analysis (XRD). The presence of copper in the structure...
-
Experimental and Numerical Analysis of Air Trapping in a Porous Medium with Coarse Textured Inclusions
PublicationThe paper presents a 2D upward infiltration experiment performed on a model porous medium consisting of fine sand background with two inclusions made of coarser sands. The purpose of the experiment was to investigate the effects of structural air trapping, which occurs during infiltration as a result of heterogeneous material structure. The experiment shows that a significant amount of air becomes trapped in each of the inclusions. Numerical...
-
Application of magnetic nanoparticles for magnetic solid-phase extraction in preparing biological, environmental and food samples
PublicationThe need to obtain meaningful results as the basis for determining the content of trace amounts of analytes has become the driving force behind the development of modern analytical techniques, including sample-preparation techniques, such as solid-phase extraction (SPE). Recently, great interest was aroused in the use of magnetic nanoparticles (MNPs) in SPE. These materials exhibit high selectivity, and, in small amounts, can provide...
-
Simulation of the Remanence Influence on the Transient States of the Single-Phase Transformer Including Feedback Preisach Model
PublicationThis paper presents the results of the experimental and simulation investigation concerning the influence of remanence in the core of a single-phase transformer at the no-load transient state. Experimental studies consisted of the discharge of the capacitor through the primary winding at several different values of the residual magnetic flux. The paper presents a model of the transformer test system, taking into account the magnetic...
-
Feasibility Study of Three-Phase Modular Converter for Dual-Purpose Application in DC and AC Microgrids
PublicationThe modern concept of a universal converter is intended as a power converter (PC) suitable for application in both dc or ac grids using the same external connectors. This novel family was recently proposed to allow easier integration of renewable energy sources and energy storage systems (ESSs), interfacing with dc/ac grids and/or loads with a minimum redundancy of power switches and passive elements. This kind of solution and...
-
A gap waveguide-based mechanically reconfigurable phase shifter for high-power Ku-band applications
PublicationThis paper presents a novel design of a low-loss, reconfgurable broadband phase shifter based on groove gap waveguide (GGW) technology. The proposed phase shifter consists of a folded GGW and three bends with a few pins forming the GGW and one bend attached to a movable plate. This movable plate allows for adjustments to the folded waveguide length, consequently altering the phase of electromagnetic waves. The advantage of GGW...
-
Structural phase transitions in multicomponent La0.2Nd0.2Sm0.2Gd0.2RE50.2NbO4 (RE5 = Ho, Y, Tb, Eu, Pr) oxides
PublicationIn this work, the influence of compositional complexity on the structural and thermal properties of multicomponent rare-earth ortho-niobates from the La0.2Nd0.2Sm0.2Gd0.2RE50.2NbO4 (RE5 = Ho, Y, Tb, Eu, Pr) series have been investigated. Based on X-ray powder diffraction studies using synchrotron radiation, it was found that all tested materials were pure single-phase compositions and showed stability in the monoclinic I2/c crystal...
-
Development of nanoscale morphology and role of viscoelastic phase separation on the properties of epoxy/recycled polyurethane blends
PublicationA novel and cost-effective approach towards the modification of epoxy matrix has been developed using recycled polyurethane for the first time without sacrificing any of the intrinsic properties of the resin. Polyurethane, recycled from waste foam by glycolysis process (RPU), was found to be very effective in improving the properties of the thermosetting resin based on Diglycidyl ether of bisphenol-A (DGEBA). The effect of the...
-
Effectiveness of toluene separation from gas phase using supported ammonium ionic liquid membrane
PublicationAmmonium ionic liquids (ILs) are relatively cheap in synthesis and environmentally benign and despite that they have been very rarely used in gas separation. In this research we used several ammonium ILs as liquid membranes for removal of residual toluene from gas phase. Ionic liquids used in this study were composed of bis(trifluoromethylsulfonyl)imide anion [Tf2N] and trimethylbutylammonium [N1114], trietylbutylammonium [N2224],...
-
Sensorless five-phase induction motor drive with third harmonic injection and inverter output filter
PublicationThe paper presents a sensorless control approach for a five-phase induction motor drive with third harmonic injection and inverter output filter. In the case of the third harmonic injection being utilised in the control, the physical machine has to be divided into two virtual machines that are controlled separately and independently. The control system structure is presented in conjunction with speed and rotor flux observers that...
-
Deep eutectic solvents in analytical sample preconcentration Part B: Solid-phase (micro)extraction
PublicationOne of the key challenges of modern analytical chemistry is the monitoring of trace amounts of contaminants using sensitive and selective instrumental techniques. Due to the variety and complexity of some samples, it is often necessary to properly prepare a sample and to perform a preconcentration of trace amounts of analytes. In line with the principles of Green Analytical Chemistry (GAC), it is important for an analytical procedure...
-
Understainding solid-phase microextraction: key factors influencing the extraction process and trends in improving the technique
PublicationAnalytical chemists are faced with the daunting challenges of accurately monitoring the state of the environment and the processes taking place in it and of determining an enormous range of analytes often present in trace and ultratrace amounts in sample matrixes with complex or variable compositions. Further challenges are presented by the need to introduce new methodologies into current analytical practice and equipment to comply...
-
Design of three-phase three-level CIC T-source inverter with maximum boost control
Publication -
Safety and efficacy of lenabasum in a phase 2 randomized, placebo-controlled trial in adults with cystic fibrosis
Publication -
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
Publication -
The application of gradient reversed-phase high-performance liquid chromatography to the pKa and determination of polyprotic analytes
Publication -
The influence of type of dispersed phase on rolling contact fatigue of lubricating greases on mineral base oil
Publication -
Synthesis and structural properties of carbon/alumina composites: Practical application in solid phase extraction of explosives
Publication -
Custom FBGs inscription using modified phase mask method with precise micro- and nano-positioning
Publication -
Phase Transitions and Structural Changes in DPPC Liposomes Induced by a 1-Carba-Alpha-Tocopherol Analogue
Publication -
Application of sublation and two phase titration methods for analytical of surfactants in AFFF fire-fighting foams
PublicationCelem badań była próba opracowania odpowiedniej metody izolacji ze ścieków fluorowanych związków powierzchniowo czynnych FZPC do celów analitycznych, a także metody ich ilościowego oznaczania. W badaniach polegających na oznaczaniu stężenia FZPC w oparciu o miareczkowanie w układzie dwufazowym: woda/chloroform użyto Hyaminy 1622, jako titranta oraz błękitu metylenowego, jako wskaźnika. Kolejnym etapem badań była izolacja ZPC z...
-
Solid phase microextraction combined with chromatography - a powerful tool for determination of warfare agents and related compounds
PublicationOpisano zastosowanie mikroekstrakcji do fazy stacjonarnej do izolacji wzbogacania środków bojowych i produktów ich degradacji w powietrzu, wodzie i glebie oraz próbkach bilogicznych. Na etapie oznaczeń końcowych stosuje się najczęściej chromatografię gazową. Anality można pobierać przez bezpośrednie zanurzenie włókna w próbce ciekłej i gazowej oraz w fazie nadpowierzchniowej. Stosując SPME-GC można osiągnąć niskie granice oznaczalności...
-
A model of liquid film breakdown formed due to impingement of a two-phase jet on a horizontal surface
PublicationThe present work aims to provide an explanation to the phenomenon of breakdown of the thin liquid film created by impinging two-phase, liquid-gas jet. Existing in the literature models describe merely thebreakdown of single phase liquid films. The model presented here is based on examination of mass and energy equations under the applied criterion of the minimum of total energy. That allows to determinethe minimum thickness of...
-
Determination of butyltin stabilizers in PVC using Liquid-Phase microextraction with electrothermal atomic absorption spectrometry
Publication -
The lipophilicity indices of flavonoids estimated by reversed-phase liquid chromatography using different computation methods
PublicationDo oceny właściwości chromatograficznych wybranych flawonoidów zastosowano wyskokosprawną chromatografię cieczową z odwróconym układem faz i kolumnami chromatograficznymi typu C-8 i C-18.Lipofilowość wyrażono za pomocą różnych deskryptów lipofilowości.
-
Lipophilicity data for some preservatives estimated by reversed-phase liquid chromatography and different copmutation methods
PublicationW pracy przedstawiono wyniki badań właściwości chromatograficznych wybranych 12 związków z grupy kopnserwantów. Lipofilowy charakter tych związków był oceniany na podtsawie różnych parametrów retencyjnych (log Kw, log K i inne. Zastosowano narzędzie chemometryczne do zbadania korelacji występujących pomiędzy tymi parametrami retencji chromatogfraficznej.
-
Iron and other metal species as phase-composition controllers influencing the photocatalytic activity of TiO2 materials
Publication -
Phase behavior of π-conjugated polymer and non-fullerene acceptor (PTB7-Th:ITIC) solutions and blends
Publication -
Structure of the twist-bend nematic phase with respect to the orientational molecular order of the thioether-linked dimers
Publication -
Biaxial order and a rotation of the minor director in the nematic phase of an organo-siloxane tetrapode by the electric field
Publication -
Distortions in structures of the twist bend nematic phase of a bent-core liquid crystal by the electric field
Publication -
On the critical temperature discontinuity at the theoretical bcc-fcc phase transition in compressed selenium and tellurium superconductors
Publication -
Evaluation of the High-Pressure Gas Transmission Network Impact for Environmental - Construction Phase and Network Operation
Publication -
Impedance spectroscopy of BaTiO3 cubes suspended in lossy liquids as a physical model of two-phase system
PublicationTechniki spektroskopii impedancyjnej zostały wykorzystane do analizy modelu fizycznego w układzie dwufazowym w celu wyznaczanie stałej dielektrycznej dielektryka umieszczonego w cieczy. Badania eksperymentalne przeprowadzono z użyciem BaTiO3 jako materiału dielektrycznego, który został przygotowany jako kostki o jednakowej wielkości 2x2x1 mm3.
-
Evaluation of Three Peptide Immobilization Techniques on a QCM Surface Related to Acetaldehyde Responses in the Gas Phase
PublicationThe quartz-crystal microbalance is a sensitive and universal tool for measuring concentrations of various gases in the air. Biochemical functionalization of the QCM electrode allows a label-free detection of specific molecular interactions with high sensitivity and specificity. In addition, it enables a real-time determination of its kinetic rates and affinity constants. This makes QCM a versatile bioanalytical screening tool for...
-
Possibilities and benefits of a new method of modifying conventional building materials with phase-change materials (PCMs)
PublicationThe paper presents a current study devoted to the optimization of the amount of PCM present within traditional building materials, utilized in this case in hollow-brick walls. Authors focus on proposing an alternative to typical direct addition of PCM to existing building materials: introducing two- and three-component mixtures, based on a porous PCM carrier, which in this case was construction aggregate. Preliminary studies of...
-
Supervisory Control System for Adaptive Phase and Work Cycle Management of Sequencing Wastewater Treatment Plant
PublicationThe paper presents the design of the integrated control system applied to Sequencing Batch Reactor (SBR) in a biological Wastewater Treatment Plant (WWTP) in Swarzewo, which operates under activated sludge technology. Based on the real data records, ASM2d biological processes model and aeration system model, hierarchical control system for dissolved oxygen tracking and cycle management is designed. Internal Model Controller (IMC)...
-
Quasi-discrete modelling of PMSM phase currents in drives with low switching-to-fundamental frequency ratio
PublicationThis study proposes a new quasi-discrete approach to modelling the permanent magnet synchronous motor (PMSM). The quasi-discrete modelling reflects the impact of continuous rotor movement, which takes place during a control cycle, on the shape of motor current waveforms. This provides much improvement in current modelling accuracy under inverter low switching-to-fundamental frequency operation. The proposed approach may be used...
-
The dispersive micro-solid phase extraction method for MS-based lipidomics of human breast milk*
PublicationA simple and rapid microextraction method ensuring high lipidome coverage was developed for liquid chromatography mass spectrometry (LC-MS)-based lipidomics of human breast milk. The dispersive microsolid phase extraction (D-µ-SPE) technique, coupled with the design of experiment (DoE) method, enabled the study of the influence of several conditions (desorption solvent, stationary phase ratio, and sorption and desorption time)...