Search results for: temperature%20measurement
-
Voltage Harmonic Distortion Measurement Issue in Smart-Grid Distribution System
PublicationThis paper presents the investigation results ofvoltage harmonic transfer accuracy problems through voltagetransformers which are widely used in power quality monitoringsystems in medium and high voltage grids. A simplified lumpedparameters circuit model of the voltage transformer is presentedand verified by simulation and experimental investigations. Anumber voltage transformers typically used in medium voltagegrid has been tested...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
Nanocrystalline diamond sheets as protective coatings for fiber-optic measurement head
PublicationFiber-optic sensors find numerous applications in science and industry, but their full potential is limited because of the risk of damaging the measurement head, in particular, due to the vulnerability of unprotected tips of the fiber to mechanical damage and aggressive chemical agents. In this paper, we report the first use of a new nanocrystalline diamond structure in a fiber-optic measurement head as a protective coating of...
-
Analysis of Vibration and Acoustic Signals for Noncontact Measurement of Engine Rotation Speed
PublicationThe non-contact measurement of engine speed can be realized by analyzing engine vibration frequency. However, the vibration signal is distorted by harmonics and noise in the measurement. This paper presents a novel method for the measurement of engine rotation speed by using the cross-correlation of vibration and acoustic signals. This method can enhance the same frequency components in engine vibration and acoustic signal. After...
-
Experimental certification of an informationally complete quantum measurement in a device-independent protocol
PublicationMinimal informationally complete positive operator-valued measures (MIC-POVMs) are special kinds of measurement in quantum theory in which the statistics of their d2-outcomes are enough to reconstruct any d-dimensional quantum state. For this reason, MIC-POVMs are referred to as standard measurements for quantum information.Here, we report an experiment with entangled photon pairs that certifies, for what we believe is the first...
-
Measurement and visualization of sound intensity vector distribution in proximity of acoustic diffusers
PublicationIn this work, we would like to present analyses and visualizations of sound intensity distribution measured in proximity of an acoustic diffuser. Such distribution may be used for estimation of basic acoustic parameters of a diffuser. Measurement is performed with the use of a logarithmic sine sweep which allows for the analysis of waves scattered by the diffuser and rejecting the direct sound signal component. Pressure and sound...
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublicationThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
A review of design approaches for the implementation of low-frequency noise measurement systems
PublicationElectronic noise has its roots in the fundamental physical interactions between matter and charged particles, carrying information about the phenomena that occur at the microscopic level. Therefore, Low-Frequency Noise Measurements (LFNM) are a well-established technique for the characterization of electron devices and materials and, compared to other techniques, they offer the advantage of being non-destructive and of providing...
-
Installation of GNSS receivers on a mobile railway platform – methodology and measurement aspects
PublicationDetermining the course of a railway track axis using satellite methods relies on ensuring the precise assembly of GNSS receivers in dedicated measuring devices. Depending on the number of receivers, solutions that are based on placing the apparatus directly above the railway track axis (as well as in eccentric positions) are used to indirectly obtain data to form the basis of the desired results. This publication describes the...
-
P-674 Automatizing ovarian follicle counting and measurement with artificial intelligence
Publication -
Measurement of complex refractive index of human blood by low-coherence interferometry
PublicationIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Polarization interferometer using a Liquid Crystalline Polymer waveplate for wavelength measurement
PublicationA two-beam polarization interferometer for measuring wavelength changes of a tunable semiconductor laser was designed, built and tested. This interferometer uses a λ/8 waveplate made from Liquid Crystalline Polymer in order to generate two output signals in quadrature. The λ/8 waveplate can be manufactured either on a beamsplitter face or on the mirror surface, reducing the cost and complexity of the optomechnical assembly. Experiment...
-
Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants
PublicationThe study presents information about the measurement techniques used for the assessment of air quality in terms of the olfactory intensity resulting from the operation of municipal sewage treatment plants. Advantages and disadvantages of the measurement techniques used are presented. Sources of malodourous substance emission from sewage treatment plants were described, and the malodourous substances emitted were characterised....
-
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublicationIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
2015. Motion analysis of a kitesurfer employing a vision-based measurement system
PublicationAbstract. Kitesurfing is a relatively new phenomenon with rising popularity worldwide – a recently developed extreme watersport considered a high-risk injury sport. It combines elements of several other sports, in particular, sailing, surfing, windsurfing, wakeboarding, and snowboarding. The main purpose of authors’ research in the present paper is to use a vision-based system for measuring a kitesurfer’s body movements in order...
-
3D Monitoring - Identification of measurement problems at larger movements of the tracked points
PublicationAuthors identified the problems associated with the determination of the controlled points coordinates by use of automated Total Station placed behind transparent barrier. Important thing in the mentioned analysis was a large change of controlled points position and not stable Total Station’s stand (because of stand’s thermal drift). This two elements, combined with measurement made through glass plate determine the need for impact...
-
Low-power device simulator for micro-energy measurement methods testing
PublicationThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Distributed measurement system with data transmission secured using XXTEA algorithm
PublicationThe paper deals with wireless data transmission security in the distributed measurement and control system. An overview of cryptographic algorithms was presented paying special attention to the algorithm dedicated to units with low processing power, which is important due to minimization of energy consumption. Measurement modules equipped with simple microcontrollers send data wirelessly to the central unit. The transmission was...
-
Power and energy measurement problems in transmission line between Poland-Lithuania
PublicationThe paper discusses problem of power and energy metering in double circuit overhead transmission line. Considerations are based on example of transmission line connecting Polish substation Bis Elk and Lithuanian substation Alytus.
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublicationThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Measurement of luminance and color uniformity of displays using the large-format scanner
PublicationUniformity of display luminance and color is important for comfort and good perception of the information presented on the display. Although display technology has developed and improved a lot over the past years, different types of displays still present a challenge in selected applications, e.g. in medical use or in case of multi-screen installations. A simplified 9-point method of determining uniformity does not always produce...
-
Measurement of Impulse Response of Shallow Water Communication Channel by Correlation Method
PublicationPerformances of underwater acoustic communication (UAC) systems are strongly related to specific propagation conditions of the underwater channel; conditions that can additionally change in time due to the movement of the acoustic system transmitter and receiver or to reflection by underwater objects of the transmitted signal. The time-varying impulse response is a comprehensive description of dynamically changing transmission...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublicationThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Installation of GNSS receivers on a mobile railway platform – methodology and measurement aspects
Publication -
The evaluation of the vibration measurement usability of electronic indicator lemag "premet C"
PublicationThe measuring possibilities of modern compression and combustion pressure analyzers are extended with additional functions. One of them is parallel to the pressure measurement, the measurement of vibrations in the region of the cylinder head. The paper presents a general assessment of the vibration measurement function of the electronic indicator LEMAG "PREMET C". This feature is very rarely offered by manufacturers of these devices....
-
Analytical progress on symmetric geometric discord: Measurement-based upper bounds
PublicationQuantum correlations may be measured by means of the distance of the state to the subclass ofstates having well defined classical properties. In particular, a geometric measure of asymmetricdiscord [Daki´c et al., Phys. Rev. Lett. 105, 190502 (2010)] was recently defined as the Hilbert-Schmidt distance of a given two-qubit state to the closest classical-quantum (CQ) correlated state.We analyze a geometric measure of symmetric...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Badanie degradacji powłok organicznych metodą EIS w warunkach podwyższonych temperatur
PublicationPomimo nieustannego rozwoju zaawansowanych technik antykorozyjnych oraz imponująco wysokiej odporności współczesnych warstw i pokryć ochronnych problem zabezpieczenia powierzchni metalicznych jak i niemetalicznych jest nadal aktualny. Wciąż rosnące zapotrzebowanie na nowe metody ochrony antykorozyjnej oraz dążenie do jak najmniejszej degradacji środowiska naturalnego wytyczają współczesne trendy rozwoju przemysłu antykorozyjnego....
-
Badania teoretyczne i doświadczalne rozkładu temperatur w hydrodynamicznym łożysku wzdłużnym
PublicationW referacie zaprezentowano przykładowe wyniki obliczeń uzyskane z wykorzystaniem rozwijanej w Politechnice Gdańskiej nowej metody oceny własności hydrodynamicznych łożysk wzdłużnych. Bazuje ona na wykorzystaniu techniki automatycznej wymiany informacji pomiędzy uwzględnianymi w analizach problemów obliczeń łożyskowych obszarami zadania tj. płynowym i strukturalnym, wykorzystując w tym celu dostępne programy obliczeniowe MES (technika...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 85
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 90 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 70
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a rectangular manifold, condenser temperature 30 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 70 and evaporator temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 95
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Temperature of formation of Au nanostructures
Open Research DataNanostructures were obtained via annealing of thin Au films. In order to determine possible nanoislands formation mechanisms, dependence on initial film thickness was examined. For the surface morphology studies, nanograin structure and chemical composition analysis, SEM, HR TEM and EDS measurements were performed, respectively. Morphology studies shown...
-
Experimental verification of multiband system of non coantact temperature measurements. IV Workshop on Atomic and Molecular Physics.
PublicationW pracy przedstawiono wielopasmowy optoelektroniczny system do bezkontaktowych pomiarów temperatury wykonane za jego pomocą w zakresie od 250 do 390 stopni Celsjusza. Przeprowadzono dyskusję błędów pomiarowych i porównano otrzymane rezultaty z wynikami modelowania komputerowego.
-
NICKEL-BASED LAYERED PEROVSKITE CATHODE MATERIALS FOR APPLICATION IN INTERMEDIATE-TEMPERATURE SOLID OXIDE FUEL CELLS
Publication -
<title>Correction of fiber optic ion sensor readings using a fiber optic temperature sensor</title>
Publication -
Temperature Measurements at Tyre Tread Rubber on Sandpaper Oscillatory Sliding Contacts Using Acicular Grindable Thermocouples
PublicationThe tribological performance of tyre–road contacts depends crucially on the contact temperature. This study investigates the reliability and accuracy of acicular grindable thermocouples possessing an original needle-shaped wearable part as applied to measuring temperature at the oscillatory sliding contact between a rubber tyre tread sample and a sandpaper. A linear oscillatory tribometer is used to imitate the sliding phase of...
-
Hyperbaric Storage at Subzero Temperature – the Effect on the Shelf-Life and Selected Quality Characteristics of Raw Pork Sausages
PublicationThe aim of this study was to determine the microbiological stability and changes occurring in selected physicochemical properties of raw pork sausages during hyperbaric storage at subzero temperature (HS-ST). It was shown that storage at moderate pressures (up to 111 MPa) led to a reduction in microbial populations. After 21 days of storage under these conditions, no microorganisms were detected in the samples. Additionally, the...
-
Biochemical assays of intensified methane content in biogas from low-temperature processing of waste activated sludge
PublicationAnaerobic digestion (AD) is implemented as an important ‘waste to energy’ approach for converting organic-rich byproducts such as sewage sludge into biogas and nutrient-rich digestate. Sewage sludge consists of primary sludge and waste activated sludge (WAS), and low biodegradability of WAS limits methane production. This study presents the influence of the low-temperature pretreatment (LT-PT) of WAS on the efficiency of AD. Different...
-
High-Temperature Tensile Behaviour of GTAW Joints of P92 Steel and Alloy 617 for Two Different Fillers
PublicationThis study explores the high-temperature (HT) tensile rupture characteristics of a dissimilar gas-tungsten-arc-welded (GTAW) joint between P92 steel and Alloy 617, fabricated using ER62SB9 and ERNiCrCoMo-1 fillers. The high-temperature tensile tests were performed at elevated temperatures of 550 ◦C and 650 ◦C. An optical microscope (OM) and a field emission scanning electron microscope (FESEM) were utilized to characterize the...
-
On the tendency of temperature and electric field dependences of interface recombination in P3HT:PCBM organic bulk heterojunction solar cells
PublicationWe demonstrate theoretical explanation of the temperature and electric field dependences of recombination coefficients in an organic P3HT:PCBM bulk heterojunction solar cell. Based onthe model of interface recombination, two analytical formulas describing the relative ratio of the interface (γI ) to the Langevin (γL) recombination coefficients have been derived. Our analysis indicates that the sign of parameters φT and φF determines...
-
Experiments and Numerical Simulations of the Annealing Temperature Influence on the Residual Stresses Level in S700MC Steel Welded Elements
Publication -
Application possibilities of the low-temperature repairs on creep-resistance turbine components from material GX23CrMoV12-1
Publication -
Temperature-Based Prediction of Joint Hardness in TIG Welding of Inconel 600, 625 and 718 Nickel Superalloys
Publication -
New devices to capture the temperature effect under dynamic compression and impact perforation of polymers, application to PMMA
Publication -
MITOGEN-ACTIVATED PROTEIN KINASE 4 impacts leaf development, temperature, and stomatal movement in hybrid aspen