Filters
total: 4527
-
Catalog
displaying 1000 best results Help
Search results for: COMMERCIAL CHEMICAL SENSORS
-
Functionalized azobenzocrown ethers as sensor materials—The synthesis and ion binding properties
PublicationNew 13- and 16-membered azobenzocrown ethers with aromatic amino, amide, ether–ester or ether–amide residue in para position to an azo moiety were obtained. Acid–base properties and ion binding ability of the colored compounds were studied by spectroscopic methods: UV–vis, fluorimetry and 1H NMR spectroscopy. Selected azobenzocrowns were tested as ionophores in ion-selective membrane electrodes (ISEs) – classic and miniature all...
-
Measurement of sub-nanometer molecular layers with ISFET without a reference electrode dependency
PublicationA new method of detection and measurement with sub-nanometer resolution of layers adsorbed or bonded to the ISFET's gate dielectric was presented. The sensitivity of this method is high enough to detect even partial mono-layer covering. The transconductance measurement of the ISFET provides independence of the output signal from pH changes and the driving electrode electrochemical potential instabilities. The stable reference electrode...
-
A method to monitor urinary carbon dioxide in patients with septic shock
PublicationSevere sepsis and septic shock are life-threatening conditions with mortality rates exceeding 31% (Levy et al., 2012) [1]. Septicemia was the most expensive US hospital condition in 2011 (Torio and Andrews, 2006)[2]. Urinary carbon dioxide may provide rapid, clinically useful information about a patient’s status, empowering physicians to intervene earlier and improve septic shock mortality. The objective of this paper is to validate...
-
Laser patterned platform with PEDOT–graphene composite film for NO2 sensing
PublicationThis work presents a simple and fully electrochemical route used for fabricating of a NO2 gas sensor made of reduced-graphene-oxide-poly(3,4-ethylenedioxythiophene) composite film. The sensing platform was fabricated from alumina substrate and equipped with gold interdigitated electrodes and built-in heater.The temperature distribution on the surface of interdigitated electrodes was investigated by a thermalimaging camera and compared...
-
Fluctuation-enhanced and conductometric gas sensing with nanocrystalline NiO thin films: A comparison
PublicationNanocrystalline thin films of NiO were prepared by advanced reactive gas deposition, and their responses to formaldehyde, ethanol and methane gases were studied via fluctuation-enhanced and conductometric methods Thin films with thicknesses in the 200–1700-nm range were investigated in as-deposited form and after annealing at 400 and 500 °C. Morphological and structural analyses showed porous deposits with NiO nanocrystals having...
-
Tailoring properties of indium tin oxide thin films for their work in both electrochemical and optical label-free sensing systems
PublicationThis work is devoted to the identification properties of indium tin oxide (ITO) thin films responsible for their possible application in combined optical and electrochemical label-free sensing systems offering enhanced functionalities. Since any post-processing would make it difficult to identify direct relation between deposition parameters and properties of the ITO films, especially when deposition on temperature-sensitive substrates...
-
Combined chemoresistive and in situ FTIR spectroscopy study of nanoporous NiO films for light-activated nitrogen dioxide and acetone gas sensing
PublicationThe chemoresistive sensor response of nanoporous NiO films prepared by advanced gas deposition was investigated by combined resistivity and in situ FTIR spectroscopy, with and without simultaneous light illumination, to detect NO2 and acetone gases. The sensitivity towards NO2 increased dramatically under UV irradiation employing 275 nm light. Improved sensitivity was observed at an elevated temperature of 150 °C. In situ FTIR...
-
Electrochemical glucose sensor based on the glucose oxidase entrapped in chitosan immobilized onto laser-processed Au-Ti electrode
PublicationThe study on novel electrode material composed of structured titanium foil with embedded Au nanoparticles and modified with chitosan with entrapped glucose oxidase is presented. To confirm the successful immobilization of glucose oxidase FT-IR analysis was performed. The response of electrodes were tested towards glucose in the presence of different interference compounds and biological fluids. The prepared material exhibits excellent...
-
Macrocyclic derivatives of imidazole as chromoionophores for bismuth(III)/lead(II) pair
Publication18-membered diazomacrocycles with imidazole or 4-methylimidazole residue as a part of macrocycle were used as chromoionophores in bismuth(III) and lead(II) dual selective optodes for the first time. Cellulose triacetate membranes doped with macrocyclic chromoionophores are bismuth(III) and lead(II) selective with color change from orange/red to different shades of blue and violet, respectively. Results obtained for model and real...
-
The effects of gas exposure on the graphene/AlGaN/GaN heterostructure under UV irradiation
PublicationThis work demonstrates a graphene/AlGaN/GaN sensing device with two-dimensional electron gas (2DEG) toward nitrogen dioxide (NO2), tetrahydrofuran, and acetone detection under UV light irradiation. We propose combining measurements of the DC characteristics with a fluctuation-enhanced sensing method to provide insight into the gas detection mechanisms in the synergistic structure of highly stable GaN and gas-sensitive graphene....
-
Pyrrole bearing diazocrowns: Selective chromoionophores for lead(II) optical sensing
PublicationDiazocrowns of 18-, 21- and 23-membered rings with pyrrole residue as a part of macrocycle were for the first time used as chromoionophores in lead(II) selective optodes. Sensing properties of optodes depend on the type of macrocycle, namely its size and the type of linker: oligoether or hydrocarbon chain. The best results were obtained for optode bearing 18-membered crown with oligoether linker showing linear response range of...
-
Enhanced susceptibility of SARS-CoV-2 spike RBD protein assay targeted by cellular receptors ACE2 and CD147: Multivariate data analysis of multisine impedimetric response
PublicationSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) enters the cells through the binding of spike protein to the host cell surface-expressing angiotensin-converting enzyme 2 (ACE2) or by endocytosis mediated by extracellular matrix metalloproteinase inducer (CD147). We present extended statistical studies of the multisine dynamic electrochemical impedance spectroscopy (DEIS) revealing interactions between Spike RBD and...
-
Multisine impedimetric probing of biocatalytic reactions for label-free detection of DEFB1 gene: How to verify that your dog is not human?
PublicationAlbert is a dog (Canis familiaris), but he does not realize this. Albert loves human food (and beer), watching movies on the internet, sleeping in bed, and more. But he should not do all these things. To convince him that, we have desinged a test procedure. The DEFB1 gene is unique to human species. Detecting its presence from saliva and in short periods may offer an advantage in the field of forensic medicine, and influence Albert’s...
-
TASTE QUALITIES ESTIMATION BY TASTE SENSE AND ELECTROCHEMICAL SENSORS
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiom etric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublicationHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
Jacek Ryl dr hab. inż.
PeopleI have obtained my PhD in chemical technology in 2010. In the same year, I was employed at the Department of Electrochemistry, Corrosion and Materials Engineering at the Faculty of Chemistry. In 2018 I received habilitation at the Faculty of Chemistry GUT in technical sciences in the discipline of chemical technology. From 2021, he was employed at the Institute of Nanotechnology and Materials Science at the Faculty of Technical...
-
Potentiometric taste sensor application for liquid product taste estimation
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiometric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
Monitoring of Odour Nuisance from Landfill Using Electronic Nose
PublicationThe paper presents the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type –HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. Classification of the air samples...
-
Comparison of Quality Evaluation of Agricultural Distillates Using Prototype of Electronic Nose and Fast/Flash GC
PublicationThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. In case of the prototype volatile fraction of the agricultural distillate was prepared via barbotage process. HERACLES II analysed the...
-
Comparison of Evaluation of Air Odour Quality in Vicinity of Petroleum Plant Using a Prototype of Electronic Nose Instrument and Fast GC Technique
PublicationThe paper presents the results of investigation on classification of the ambient air samples collected in a vicinity of the LOTOS Group S.A. petroleum plant with respect to odour. The investigations were carried out with an electronic nose prototype and a commercial electronic nose of Fast GC-type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and a photoionization sensor of PID-type....
-
New approaches for improving selectivity and sensitivity of resistive gas sensors: a review
PublicationPurpose – This paper aims to present the methods of improving selectivity and sensitivity of resistance gas sensors. Design/methodology/approach – This paper compares various methods of improving gas sensing by temperature modulation, UV irradiation or fluctuation-enhanced sensing. The authors analyze low-frequency resistance fluctuations in commercial Taguchi gas sensors and the recently developed tungsten trioxide (WO3) gas-sensing...
-
Gas sampling system for matrix of semiconductor gas sensors
PublicationSemiconductor gas sensors are popular commercial sensors applied in numerous gas detection systems. They are reliable, small, rugged and inexpensive. However, there are a few problem limiting the wider use of such sensors. Semiconductor gas sensor usually exhibits a low selectivity, low repeatability, drift of response, strong temperature and moisture influence on sensor properties. Sample flow rate is one of the parameters that...
-
SENSORS
Journals -
Exhaled breath analysis by resistive gas sensors
PublicationBreath analysis has attracted human beings for centuries. It was one of the simplest methods to detect various diseases by using human smell sense only. Advances in technology enable to use more reliable and standardized methods, based on different gas sensing systems. Breath analysis requires the detection of volatile organic compounds (VOCs) of the concentrations below individual ppm (parts per million). Therefore, advanced detection...
-
Portable exhaled breath analyzer employing fluctuation-enhanced gas sensing method in resistive gas sensors
PublicationThis paper presents a portable exhaled breath analyser, developed to detect selected diseases. The set-up employs resistive gas sensors: commercial MEMS sensors and prototype gas sensors made of WO3 gas sensing layers doped with various metal ingredients. The set-up can modulate the gas sensors by applying UV light to induce physical changes of the gas sensing layers. The sensors are placed in a tiny gas chamber of a volume...
-
Energy requirements for methods improving gas detection by modulating physical properties of resistive gas sensors
PublicationAbstract. One of the most important disadvantage of resistive gas sensors is their limited gas selectivity. Therefore, various methods modulating their physical properties are used to improve gas detection. These methods are usually limited to temperature modulation or UV light irradiation for the layers exhibiting photocatalytic effect. These methods cause increased energy consumption. In our study we consider how much energy...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Ewa Wagner-Wysiecka dr hab. inż.
PeopleEwa Wagner-Wysiecka is a graduate of the Faculty of Chemistry at Gdańsk University of Technology (specializing in Chemical Technology, with a focus on Inorganic Technology and a sub-specialty in Technical and Industrial Analytics). She completed her master's thesis, entitled "Identification of Contaminants in Pharmacopoeial Sulfaquinoxaline," under the supervision of Professor Jan F. Biernat. After completing her master's degree...
-
Distributed wireless sensor for measuring humidity and temperature
PublicationHumidity and temperature monitoring is often required in industrial halls and laboratories and can be crucial, because many properties of electrical devices deteriorates under influence of these parameters. There are several useful commercial methods for measuring humidity and temperature, such as commercial hygrometers and humidity recorders. However, they do not allow data acquisition simultaneously from multiple sensors. This...
-
Comparative study on the effectiveness of various types of road traffic intensity detectors
PublicationVehicle detection and speed measurements are crucial tasks in traffic monitoring systems. In this work, we focus on several types of electronic sensors, operating on different physical principles in order to compare their effectiveness in real traffic conditions. Commercial solutions are based on road tubes, microwave sensors, LiDARs, and video cameras. Distributed traffic monitoring systems require a high number of monitoring...
-
Advanced operating methods
PublicationSelected operating methods of resistive gas sensors were presented. The methods utilize flicker noise (1/f noise), which gives additional information about ambient gas when compared with the recorded changes of DC resistance only. Methods of flicker noise measurements were outlined. Recently developed prototype gas sensors comprising golden nanoparticle functionalized with organic ligands can generate intense flicker noise induced...
-
Wojciech Chrzanowski dr hab. inż.
PeopleWojciech Chrzanowski was born in 1952 in Toruń. He completed his studies in Chemical Technology in 1975, getting his MSc in Inorganic Technology (specialty: Anti-Corrosion Protection) At the Faculty of Chemistry, Gdańsk University of Technology (with distinction). Later this year he was employed in the Department of Analytical Chemistry of then Institute of Chemical Engineering and Measuring Techniques, initially as a technical...
-
Anna Danuta Dettlaff dr inż.
PeopleShe received her Master of Science degree in engineering with honours in 2013 at the Gdańsk University of Technology at the Department of Analytical Chemistry. In 2013-2017, she was a PhD student in the field of Chemical Technology at Faculty of Chemistry. Her doctoral dissertation was entitled “Nanocomposites based on conducting polymer and carbon materials for supercapacitor application”. In 2015, she was doing a three-month...
-
AUTOMATED SYSTEM FOR FLUCTUATION ENHANCED GAS SENSING
PublicationResistance gas sensors exhibit random phenomena (resistance noise) which can be utilized to improve gas sensitivity and selectivity. That new emerging technique has to be investigated to recognize optimal parameters for gas detection. It means that a measurement system has to have ability of numerous parameters adjustment (e.g., sampling frequency, heater voltage, polarization current, voltage noise amplification). That fact induced...
-
Grzegorz Boczkaj dr hab. inż.
People -
Zirconia-based mixed potential sensor with Pt electrode prepared by spin-coating of polymeric precursor
PublicationMany types of yttria-stabilized zirconia (YSZ) based gas sensors have been explored extensively in recent years. Great attention have been directed to mixed-potential-type gas sensors. It is due to growing concerns with environmental issues. Not without a significance is the fact of very attractive performance of this type of sensor allowing to detect low concentration of pollutant gases. In this paper two types of YSZ based mixed-potential...
-
Comparison of different types of electronic nose instruments for evaluation of odour nuisance from landfill
PublicationThe paper presents and compares the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with six semiconductor sensors of TGS type. Classification of the air...
-
Quality evaluation of agricultural distillates using different types of electronic noses
PublicationThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with TGS type semiconductor sensors. HERACLES II included two chromatographic columns with different polarity of stationary phase and two FID detectors. In case of the prototype volatile fraction...
-
FFT analysis of temperature modulated semiconductor gas sensor response for the prediction of ammonia concentration under humidity interference
PublicationThe increasing environmental contamination forces the need to design reliable devices for detecting of the volatile compounds present in the air. For this purpose semiconductor gas sensors, which have been widely used for years, are often utilized. Although they have many advantages such as low price and quite long life time, they still lack of long term stability and selectivity. Namely, environmental conditions have significant...
-
Customization of UWB 3D-RTLS Based on the New Uncertainty Model of the AoA Ranging Technique
PublicationThe increased potential and effectiveness of Real-time Locating Systems (RTLSs) substantially influence their application spectrum. They are widely used, inter alia, in the industrial sector, healthcare, home care, and in logistic and security applications. The research aims to develop an analytical method to customize UWB-based RTLS, in order to improve their localization performance in terms of accuracy and precision. The analytical...
-
Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation
PublicationA procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...
-
Thermal dewetting as a method of surface modification of the gold thin films for surface plasmon resonance based sensor applications
PublicationHere, we report a quick and simple approach with low, optimized production costs to obtain surface plasmon resonance (SPR) based sensors fabricated through a time- and resource-effective method based on thermal dewetting of thin Au films. From the applicative point of view, the method of detection presented here should be easier to implement, since light transmission measurements seem to be much less challenging than light refractive...
-
Challenges associated with development of AUV - unmanned autonomous underwater vehicles to be operated using the AI-based control systems
PublicationThe last decade has been devoted towards further development of the UUV unmanned underwater vehicles which may be of two types. There are the USV unmanned surface vehicles and UUV unmanned underwater vehicles. There is a growing interest to work out and implement the fully advanced AUV autonomous underwater vehicles. The main drivers towards development of such the vehicles are the technologies of autonomous systems, sensors and...
-
JOURNAL OF CHEMICAL PHYSICS
Journals -
Piotr Płotka dr hab. inż.
PeoplePiotr Płotka received the M.Sc. and D.Eng. degrees in electronic engineering from the Gdansk University of Technology, Poland, in 1976 and 1985. In 2008 he received D.Sc. (Dr.Hab.) degree, also in electronic engineering, from the Institute of Electron Technology at Warsaw, Poland. From 1977 he was with Academy of Technology and Agriculture at Bydgoszcz, Poland and from 1981 with the Gdansk University of Technology. In cooperation...
-
INVESTIGATION OF ACIDIC SOLUTIONS BY POTENTIOMETRIC TASTE SENSOR WITH ALL SOLID STATE ELECTRODES
PublicationPotentiometric taste sensors with electrodes containing lipophilic compound / polymer membranes were already used to distinguish commercial liquid products. In this paper a new potentiometric taste sensor consisting of six All Solid State Electrodes (ASSEs) has been presented. Each of the membrane contains a selected lipophilic compound. The set-up consists of a reference electrode and six ASSEs. The inner layer made of a conducting...
-
Sensors and System for Vehicle Navigation
PublicationIn recent years, vehicle navigation, in particular autonomous navigation, has been at the center of several major developments, both in civilian and defense applications. New technologies, such as multisensory data fusion, big data processing, or deep learning, are changing the quality of areas of applications, improving the sensors and systems used. Recently, the influence of artificial intelligence on sensor data processing and...
-
Rengel Cane Sia Doctoral Candidate
PeopleI'm Rengel, born and raised in the Philippines. As an undergraduate I did kinetic modeling on Copper-catalyzed atom transfer radical addition (ATRA). Then I was inspired to do both theoretical and experimental studies, which led me to propose my master's thesis on Synthesis, Computational, Electrochemical, and Photoconductivity Studies on Naphthalene and its derivatives. This led to a master's degree in Chemistry in the Mindanao...
-
Behavior Based Complete Coverage Task of Unknown Area by an Autonomous Mobile Robot SCORPION with Static Obstacles in Environment
PublicationIn the paper the behavior based control system of an autonomous mobile robot SCORPION is presented to execute the one of the most difficult navigation task, which is the complete coverage task of unknown area with static obstacles in the environment. The main principle assumed to design control system was that the robot should cover all area only once, if it possible, to optimize the length of path and energy consumption. All commercial...
-
Accuracy of a low-cost autonomous hexacopter platforms navigation module for a photogrammetric and environmental measurements
PublicationA photogrammetry and environmental measurements from an unmanned aerial vehicle (UAV) are a low-cost alternative for a traditional aerial photogrammetry. A commercial off-the-shelf products (COTS) offers a variety of cheap components that a suitable to be used on board a UAV. In this paper a low-cost navigation module based on Ublox NEO-M8N GPS and Pixhawk flight controller have been described, as a main extrinsic parameters source...