Filters
total: 7335
displaying 1000 best results Help
Search results for: assessment of metrological properties
-
Measurements of the coefficients of current distribution between two generators operating in parallel in a ship power station
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the coefficients...
-
Measurements of apparent power distribution in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing an apparent...
-
Selected results of signal measurements in a ship power station with two generators working in parallel with the use of the Estimator/Analyzer instrument
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/ Analyser (A/E v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering, of Gdynia Maritime University. The instrument performs a set of measurement functions that...
-
Measurements of active power coefficients in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing active...
-
Measurements of the coefficients of active power distribution between two generators operating in parallel in a ship power station
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing coefficients...
-
Measurements of active power distribution in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data expressing an active...
-
Measurements of reactive power distribution in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing a reactive...
-
Jerzy Wtorek prof. dr hab. inż.
PeopleJerzy Wtorek received the M.Sc., the Ph.D. and the D.Sc. degrees in electronics from Gdańsk University of Technology, Gdańsk, Poland, in 1976, 1986, and 2004, respectively. He has been with Electronics, Telecommunication and Informatics Faculty, Gdańsk University of Technology since 1977. He is currently an Associate Professor at Biomedical Engineering Department. His research interests include the developing of noninvasive methods...
-
Application of multivariate statistics in assessment of green analytical chemistry parameters of analytical methodologies
PublicationThe study offers a multivariate statistical analysis of a dataset, including the major metrological, “greenness” and methodological parameters of 43 analytical methodologies applied for aldrin determination (a frequently analyzed organic compound) in water samples. The variables (parameters) chosen were as follows: metrological (LOD, recovery, RSD), describing the “greenness” (amount of the solvent used, amount of waste generated)...
-
Application of Ionic Liquids in Amperometric Gas Sensors
PublicationThis article presents an analysis of available literature data on metrological parameters of the amperometric gas sensors containing ionic liquids as an electrolyte. Four mechanism types of signal generation in amperometric sensors with ionic liquid are described. Moreover, this article describes the influence of selected physico-chemical properties of the ionic liquids on the metrological parameters of these sensors. Some metrological...
-
Wpływ kształtu elektrody woltamperometrycznej na jej właściwości metrologiczne w dziedzinie czasu
PublicationW artykule omówiono właściwości metrologiczne elektrod woltamperometrycznych. Wykazano, że w przypadku oznaczania małych wartości stężeń jonów metali, elektrody te zachowują się tak jak przetworniki pomiarowe I rzędu. Ich właściwości metrologiczne opisuje czułość i stała czasowa. Wartości tych wielkości są uzależnione od mechanizmu transportu jonów do/od powierzchni elektrod oraz od ich kształtu. Wykonano symulacje wpływu kształtu...
-
Zastosowanie metody galwanostatycznej do wyznaczania błędu fazy elektrod woltamperometrycznych
PublicationW pracy przeanalizowano właściwości metrologiczne elektrod woltamperometrycznych w dziedzinie częstotliwości. Wykazano, że w przypadku, gdy reakcja elektrochemiczna kontrolowana jest procesem transportu jonów, elektroda woltamperometryczna zachowuje się tak jak przetwornik pomiarowy I rzędu. Jej właściwości metrologiczne opisane są przez czułość, częstotliwość graniczną, błąd amplitudy i błąd fazy. Przeprowadzona analiza pokazała,...
-
Application of TOPSIS for Selection and Assessment of Analytical Procedures for Ibuprofen Determination in Wastewater
PublicationThis paper describes the possible implementation of the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) as green analytical chemistry metrics tools. TOPSIS is one of the multi-criteria decision analysis (MCDA) tools that is applied in the selection of the best alternative from many possible. In this case we have applied it to assess the nineteen analytical procedures for ibuprofen determination in wastewater...
-
Methodology for determining the elemental composition, as well as energy and ignition properties of the low-sulfur marine fuels
PublicationThe key metrological issue of substance and energy balance in research engines is the precise determination of the elemental composition of the applied fuel and its net calorific value. This makes it possible to calculate the amount of heat brought with the fuel into the combustion chamber, as well as the amount and gas composition of the exhaust. However, to fully assess the energy quality of the fuel used, its ignition properties...
-
A concept of measurement system based on the Z-Wave standard
PublicationIn the paper a new concept of measurement system based on the Z-Wave standard is presented. This standard is dedicated to use mainly in home automation systems, but its properties enable to use it in dispersed measurement systems and support wireless communication between measurement nodes in a mesh-type network. In the paper basic metrological aspects of the Z-Wave standard and an example of impedance measurement system are discussed.
-
Hasse diagram as a green analytical metrics tool: ranking of methods for benzo[a]pyrene determination in sediments
PublicationThis study presents an application of the Hasse diagram technique (HDT) as the assessment tool to select the most appropriate analytical procedures according to their greenness or the best analytical performance. The dataset consists of analytical procedures for benzo[a]pyrene determination in sediment samples, which were described by 11 variables concerning their greenness and analytical performance. Two analyses with the HDT...
-
Green analytical chemistry introduction to chloropropanols determination at no economic and analytical performance costs?
PublicationIn this study we perform ranking of analytical procedures for 3-monochloropopane-1,2-diol determination in soy sauces with PROMETHEE method. Multicriteria decision analysis was performed for three different scenarios – metrological, economic and environmental, by application different weights to decision making criteria. All three scenarios indicate capillary electrophoresis – based procedure as the most preferable. Apart from...
-
Application of Complementary Signals in Built-In Self Testers for Mixed-Signal Embedded Electronic Systems
PublicationThis paper concerns the implementation of shape-designed complementary signals (CSs), matched to the frequency characteristic of the circuit under test, in built-in self testers (BISTs), dedicated to mixed-signal embedded electronic systems for testing their analog sections. The essence of the proposed method and solution of CS BIST is low-cost realization on the base of hardware and software resources of microcontrollers used...
-
Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air
PublicationThe paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones....
-
Temperature Fiber-Optic Sensor with ZnO ALD Coating
PublicationThis study presents a microsphere-based fiber-optic sensor with a ZnO Atomic Layer Deposition (ALD) coating thickness of 100 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range of 100 °C to 300 °C, with a 10 °C step. An interferometric signal is used to control whether the microstructure is whole. Spectrum shift of a reflected signal is used to ascertain changes in...
-
An analytical hierarchy process for selection of the optimal procedure for resveratrol determination in wine samples
PublicationThe study shows the application of analytical hierarchy process (AHP) in ranking the analytical procedures, that are applied for resveratrol determination in wine samples. 19 different analytical methodologies are described by metrological, economic and environmental criteria, that are further divided into 10 subcriteria. Before AHP application, the amount of input data is decreased with cluster analysis. The first run of AHP is...
-
Multicriteria decision analysis in ranking of analytical procedures for aldrin determination in water
PublicationThe study presents the possibility of multi-criteria decision analysis (MCDA) application when choosing analytical procedures with low environmental impact. A type of MCDA, Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE), was chosen as versatile tool that meets all the analytical chemists – decision makers requirements. Twenty five analytical procedures for aldrin determination in water samples (as...
-
Emerging strategies for enhancing detection of explosives by artificial olfaction
PublicationExplosives detection systems need to be able to reliably detect a wide range of explosive materials and their vapours. The continued development and improvement of artificial olfaction techniques, including electronic nose (EN), remains important to overcome existing challenges and meet requirements posed by new improvements in the field of explosives. There is an increasingly popular trend aimed at improvement of fundamental metrological...
-
Application of deep eutectic solvents in atomic absorption spectrometry
PublicationAtomic absorption spectrometry (AAS) is a widely applied technique for metal quantification due to its practicality, easy use and low cost. However, to improve the metrological characteristics of AAS, in particular the sensitivity and the detection limit, sample pretreatment is commonly used before the detection step itself. In consideration of the principles of Green Analytical Chemistry, new solvents are being introduced into...
-
Optical-Fiber Microsphere-Based Temperature Sensors with ZnO ALD Coating—Comparative Study
PublicationThis study presents the microsphere-based fiber-optic sensor with the ZnO Atomic Layer Deposition coating thickness of 100 nm and 200 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range from 100 °C to 300 °C, with a 10 °C step. The interferometric signal was used to monitor the integrity of the microsphere and its attachment to the connecting fiber. For the sensor...
-
Optoelectronic device for hematocrit measurements
PublicationAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Warstwowa ocena epidemiologiczna architektury zakładów opiekuńczo-leczniczych i zakładów gieriatycznych = Layer based epidemiological quality assessment of architecture of care security and geriatric wards
PublicationW artykule opisano możliwość wykorzystania autorskiej metody warstwowej oceny epidemiologicznej (WOE) do oceny potencjalnego ryzyka zakażeń w obiektach przeznaczonych dla osób starszych. Materiał i metody: W celu weryfikacji możliwości użycia metody WOE do oceny zagrożeń w zakresie bezpieczeństwa epidemiologicznego środowiska zbudowanego poddano analizie dostępne źródła literatury związane z obowiązującymi w Polsce wymaganiami...
-
Measurement system based on USB Z-Wave controller
PublicationA wireless measurement system based on the Z-Wave standard is presented in this paper. The system is composed of a U SB Z-Stick Gen5 controller connected to a Personal Computer and a Fibaro controller FGRGBWM-441. Operation of the system is controlled by software written in C++ using OpenZWave library. Some metrological aspects of the system are evaluated: accuracy, linearity, resolution and frequency of voltage measurements.
-
Time Delay Estimation in Two-Phase Flow Investigation Using the γ-Ray Attenuation Technique.
PublicationTime delay estimation is an important research question having many applications in a range of technologies. Measurement of a two-phase flow in a pipeline or an open channel using radioisotopes is an example of such application. For instance, the determination of velocity of dispersed phase in that case is based on estimation of the time delay between two stochastic signals provided by scintillation probes. The proper analysis...
-
Wpływ stopowania laserowego z użyciem nanorurek węglowych stopu Ti13Nb13Zr do zastosowań biomedycznych na jego wybrane własności mechaniczne
PublicationDo eksperymentu użyto stopu tytanu Ti13Nb13Zr, który ze względu na swój skład chemiczny i właściwości mechaniczne stanowi materiał do zastosowań w inżynierii medycznej. Celem pracy była ocena wpływu stopowania laserowego stopu Ti13Nb13Zr z powłoką z wielościennych nanorurek węglowych na jego właściwości mechaniczne (chropowatość, nanotwardość, moduł Younga). Do wytworzenia powłoki węglowej wykorzystano metodę osadzania elektroforetycznego (EDP)....
-
Evaluation of Linkers’ Influence on Peptide-Based Piezoelectric Biosensors’ Sensitivity to Aldehydes in the Gas Phase
PublicationRecent findings qualified aldehydes as potential biomarkers for disease diagnosis. One of the possibilities is to use electrochemical biosensors in point-of-care (PoC), but these need further development to overcome some limitations. Currently, the primary goal is to enhance their metrological parameters in terms of sensitivity and selectivity. Previous findings indicate that peptide OBPP4 (KLLFDSLTDLKKKMSEC-NH2) is a promising...
-
Uncertainty analysis of measuring system for instantaneous power research
PublicationThe paper presents a metrological analysis of the measurement system used for diagnosis of induction motor bearings, based on the analysis of the instantaneous power. This system was implemented as a set of devices with dedicated software installed on a PC. A number of measurements for uncertainty estimation was carried out. The results of the measurements are presented in the paper. The results of the aforementioned analysis helped...
-
Opracowanie technologii naprawy nieciągłości metalicznych w połączeniach spawanych, w konstrukcji podpór przednich pras filtracyjnych położonych na terenie Grupowej Oczyszczalni Ścieków Dębogórze
PublicationCelem niniejszej pracy jest opracowanie wytycznych technologicznych, których wdrożenie pozwoli na usunięcie istniejących pęknięć, co przyczyni się do stabilizacji wymiarowej podpór oraz całej konstrukcji pras. Osiągniecie tego celu wymaga podjęcia następujących działań: - ocenę stanu technicznego naprawianego komponentu- podpór przednich trzech pras filtracyjnych, - określenie własności spawalniczych materiału naprawianego, -...
-
Validation of atmospheric aerosols parallel sampling in a multifold device
PublicationIn this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling...
-
The use of low-coherence interferometer for sugar content determination
PublicationIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
Sharp transitions in low-number quantum dots Bayesian magnetometry
PublicationWe consider Bayesian estimate of static magnetic field, characterized by a prior Gaussian probability distribution, in systems of a few electron quantum dot spins interacting with infinite temperature spin environment via hyperfine interaction. Sudden transitions among optimal states and measurements are observed. Usefulness of measuring occupation levels is shown for all times of the evolution, together with the role of entanglement...
-
Adaptive filtering approach to dynamic weighing: a checkweigher case study
PublicationDynamic weighing, i.e., weighing of objects in motion, with out stopping them on the weighing platform, allows one to increase the rate of operation of automatic weighing systems used in industrial production processes without compromising their accuracy. The paper extends and compares two approaches to dynamic weighing, based on system identification and variable-bandwidth filtering, respectively. Experiments, carried on a conveyor...
-
Innovative mobile method to determine railway track axis position in global coordinate system using position measurements performed with GNSS and fixed base of the measuring vehicle
PublicationThe shape of the railway track axis and its position in the global coordinate system are essential when defining design parameters of the railway. Correct reconstruction of these quantities is vital for both verifying the compliance of real track parameters with the design and for diagnosing, as all track deformations can also be defined as deviations of real parameters from their design values. The measurements of quantities related...
-
Identyfikacja gatunku stali zastosowanej w obiektach budowlanych
PublicationEksploatacja istniejących metalowych konstrukcji budowlanych często związana jest z zagadnieniem koniecznej szczegółowej identyfikacji rodzaju materiału stalowego pod kątem je go cech wytrzymałościowych i składu chemicznego. Dostępne standardowe metody laboratoryjne zazwyczaj wymagają pobrania z konstrukcji próbek materiału do badań, co nie zawsze jest możliwe. W artykule zaprezentowano alternatywne metody oceny wymienionych cech...
-
Badania eksperymentalne rezonansowego przetwornika piezoelektrycznego typu "unimorph"
PublicationW artykule opisano badania eksperymentalne piezoelektrycznego rezonansowego przetwornika zastosowanego do pomiaru właściwości mechanicznych tkanek miękkich. Po krótkim wstępie w kolejnych punktach przedstawiono opis stanowiska pomiarowego oraz metody pomiaru odkształceń prototypów, przesunięć częstotliwości rezonansowej, impedancji elektromechanicznej i parametrów schematów zastępczych. W dalszej...
-
Właściwości niskotemperaturowe betonów asfaltowych o wysokim module sztywności (AC-WMS) w badaniach trzypunktowego zginania
PublicationArtykuł przedstawia właściwości niskotemperaturowe betonów asfaltowych o wysokim module sztywności. Przedstawione wyniki zostały uzyskane w dwóch badaniach zginania trzypunktowego próbek belkowych: ze stałą prędkością przemieszczenia oraz pod stałym obciążeniem. Obie te metody są od dawna stosowane na Politechnice Gdańskiej do oceny właściwości niskotemperaturowych betonów asfaltowych. Badaniu poddano pięć betonów asfaltowych –...
-
Determination of long-chain aldehydes using a novel quartz crystal microbalance sensor based on a biomimetic peptide
PublicationThere is an increasingly popular trend aimed at improvement of fundamental metrological parameters of sensors via implementation of materials mimicking biological olfactory systems. This study presents investigation on usefulness of the peptide mimicking HarmOBP7 region as a receptor element of the piezoelectric sensor for selective analysis of long-chain aldehydes. Identification of odorant binding proteins creates new possibilities...
-
Miniaturized impedance analyzer using AD5933
PublicationThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Miniaturized impedance analyzer using AD5933
PublicationThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Three-Dimensional Fractography for Conventional and Additive Manufactured Steels After Bending-Torsion Fatigue
PublicationIn this study, fracture surface topography parameters were measured to investigate the effects of multiaxial loading. In order to assess the metrological aspects of fracture for notched specimens made of high-strength steels processed by both conventional and additively manufacturing (AM) techniques, an optical surface profilometer was used. Three bending moment to torsion moment ratios (B/T) were studied, i.e. 2, 1 and 2/3. The...
-
Projektowanie, synteza i charakterystyka fotokatalizatorów nowej generacji na bazie związku Ti3C2Tx do usuwania aktywnych substancji farmaceutycznych
PublicationCelem niniejszej pracy było zastosowanie materiałów nowej generacji na bazie związku Ti3C2Tx w procesach fotokatalitycznej degradacji aktywnych substancji farmaceutycznych: karbamazepiny, acetaminofenu i ibuprofenu. Zakres prac badawczych obejmował syntezę fotokatalizatorów, charakterystykę ich właściwości fizykochemicznych, oraz ocenę aktywności fotokatalitycznej. Przedstawiono możliwość zastosowania węglika tytanu jako kokatalizatora...
-
ENVIRONMENTAL MONITORING AND ASSESSMENT
Journals -
A numerical and experimental analysis of multi-hole orifice in turbulent flow
PublicationIn this research study, the comprehensive metrological analysis is investigated for a 4-hole orifice with module m = 0.25 installed in the pipeline with an internal diameter of 50 mm. A detailed numerical simulation was performed for the turbulence models: k-ε-realizable and k-ω-BSL. The novelties of the research include model validation by comparing the results of numerical studies with the experiment conducted in the area of...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublicationIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...