Filters
total: 659
filtered: 601
-
Catalog
Chosen catalog filters
Search results for: fault trees
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublicationW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Noninvasive method for rotor fault diagnosis in inverter fed induction motor drive
PublicationThis article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Fault detection in the marine engine using a support vector data description method
PublicationFast detection and correct diagnosis of any engine condition changes are essential elements of safety andenvironmental protection. Many diagnostic algorithms significantly improve the detection of malfunctions.Studies on diagnostic methods are rarely reported and even less implemented in the marine engine industry.To fill this gap, this paper presents the Support Vector Data Description (SVDD) method as applied to thefault detection...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublicationStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Diagnosis of fully differential circuits based on a fault dictionary implemented in the microcontroller systems
PublicationPrzedstawiono nową koncepcję testera wbudowanego bist przeznaczonego do diagnostyki w pełni różnicowych układów analogowych implementowanych w mikrosystemach mieszanych sygnałowo. w trakcie testowania mierzona jest amplituda i faza wyjściowego napięcia różnicowego. procedura detekcji i lokalizacji uszkodzeń bazuje na słowniku uszkodzeń przechowywanym w pamięci programu mikrokontrolera. korzystną cechą przestrzeni pomiarowej wyznaczonej...
-
On fault diagnosis of analogue electronic circuits based on transformations in multi-dimensional spaces.
PublicationPrzedstawiono ideę nowej klasy metod diagnostycznych opartej na przekształceniu transformującym zmiany parametru układu na krzywe identyfikacyjne w przestrzeniach wielowymiarowych. Rozszerzono również klasę tych metod na diagnostykę uszkodzeń wielokrotnych. Dla takich metod omówiono algorytm lokalizacji i identyfikacji pojedynczych i wielokrotnych uszkodzeń parametrycznych w liniowych układach elektronicznych. Przedstawiono rezultaty...
-
The measurement and calculation of gas temperature inside a switchgear during fault arc period.
PublicationW artykule przedstawiono metodę obliczania temperatury gazu wewnątrz rozdzielnicy szczelnej z izolacją powietrzną podczas zwarć łukowych w oparciu o równanie przewodnictwa cieplnego. Przedstawiono wyniki badań eksperymentalnych temperatury gazów podczas zwarć z łukiem wędrującym. Opisano model do badań, układ probierczy i warunki badań. Wyniki obliczeń porównano z wynikami badań eksperymentalnych.
-
Analog fault signature based on sigma-delta modulation and oscillation-test methodology.
PublicationW artykule dokonano przeglądu prac z zakresu testowania układów elektronicznych metodą oscylacyjną. Wskazując na niedostatki aktualnie stosowanej techniki testowania oscylacyjnego zaproponowano nową sygnaturę uszkodzeń dla układów analogowych. Proponowany parametr diagnostyczny jest wydobywany z odpowiedzi czasowej oscylatora testującego, w układzie złożonym z detektora szczytowego, modulatora sigma-delta oraz licznika rewersyjnego....
-
Priority-enabled optimization of resource utilization in fault-tolerant optical transport networks.
PublicationW artykule zaproponowano nowe podejście do optymalizacji rozdziału zasobów przeżywalnych sieci rozległych, które uzależnia szybkość przywracania ciągłości połączenia od klasy usługi. Wykazano, iż proponowana metoda nie powoduje wydłużania ścieżek zabezpieczających (w przypadku usług w wymaganej wysokiej jakości obsługi) lub czyni to w sposób minimalny (dla pozostały usług). Ze względu na fakt, że zadanie znalezienia ścieżek aktywnych...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublicationThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
PublicationDynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Five-phase Induction Motor Drive Operation During Stator Phase Fault
PublicationThe article presents the most important advantages of multi-phase electric drives. The construction of a five-phase squirrel cage induction motor together with possible stator winding distribution cases is presented, which affect the properties of such motor. Increased reliability of five-phase drives was indicated. The drive operation properties were confirmed by experimental results.
-
Impact of DC fault blocking capability on the sizing of the DC-DC Modular Multilevel Converter
Publication -
Condition monitoring and fault detection in wind turbines based on cointegration analysis of SCADA data
Publication -
On Cointegration Analysis for Condition Monitoring and Fault Detection of Wind Turbines Using SCADA Data
Publication -
Mechanical response of buried High-Density Polyethylene pipelines under normal fault motions
Publication -
Sensorless algorithm for sustaining controllability of IPMSM drive in electric vehicle after resolver fault
PublicationThis paper presents a sensorless algorithm designated for the emergency control of an interior permanent magnet synchronous motor (IPMSM) drive in electric or hybrid vehicle. The algorithm is based on analysing the derivatives of motor phase currents measured over the duration of particular inverter states. The method is computationally simple and does not require additional hardware since the derivatives are measured indirectly....
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Novel Fault Identification for Electromechanical Systems via Spectral Technique and Electrical Data Processing
PublicationIt is proposed, developed, investigated, and validated by experiments and modelling for the first time in worldwide terms new data processing technologies, higher order spectral multiple correlation technologies for fault identification for electromechanical systems via electrical data processing. Investigation of the higher order spectral triple correlation technology via modelling has shown that the proposed data processing technology...
-
Energy quality improvement by ultra rapid L. V. fault current limiting andinterrupting.
PublicationPrzedstawiono możliwość ograniczania rozprzestrzeniania się zapadów napięcia w sieciach elektroenergetycznych przy zwarciach przez zastosowanie łączników hybrydowych do ultra szybkiego ograniczania i wyłączania prądów zwarciowych. Referat ma na celu przedstawienie dotychczasowych osiągnięć prac badawczych w dziedzinie łączników ultra szybkich, a także poznanie opinii elektroenergetyki i odbiorców na temat celowości wprowadzenia...
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Using an IEEE1149.1 Test Bus for Fault Diagnosis of Analog Parts of Electronic Embedded Systems
PublicationThe new solution of a BIST called the JTAG BIST for self-testing of analog parts of electronic embedded systems is presented in the paper. The JTAG BIST consists of the BCT8244A and SCANSTA476 integrated circuits of Texas Instruments controlled via the IEEE 1149.1 bus. The BCT8244A is a scan test device with octal buffers, and the SCANSTA476 is a 12-bit ADC with 8 analog input channels. Self-testing approach is based on the fault...
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Redukcja czasu analizy MZP przez ograniczenie rozmiaru rozwiązania
PublicationAnaliza drzew niezdatności jest uznaną metodą analizy bezpieczeństwa systemów. Notacja ECSDM pozwala definiować zależności czasowe między zdarzeniami drzewa oraz przeanalizować je w celu określenia zależności pomiędzy zdarzeniami z Minimalnych Zbiorów Przyczyn (MZP). Dzięki wprowadzeniu klasyfikacji zdarzeń z MZP można wyodrębnić zależności czasowe istotne dla zapobiegania wywoływania hazardu przez konkretny MZP. Pozostałe zależności...
-
Dynamic Research of Masonry Vault in a Technical Scale
PublicationThe paper presents preliminary results of dynamic tests of the masonry barrel vault in a technical scale. Experimental studies are intended to identify material properties of homogenized masonry vaults under dynamic loads. The aim of the work is to create numerical models to analyse vault’s dynamic response to dynamic loads in a simplest and accurate way. The process of building the vault in a technical scale is presented in the...
-
An implementation of deterministic tree automata minimization
PublicationWstępujący, deterministyczny, skończony automat drzewiasty (DTA) może być używany jako struktura danych do przechowywania zbiorów nieuporządkowanych drzew bez narzuconej liczby poddrzew. Takie automaty są zwykle rzadsze niż automaty działające na napisach i dlatego należy zwrócić szczególną uwagę na ich wydajną minimalizację. W dostępnej literaturze jest jednak ciężko znaleźć proste i szczegółowe opisy procedury minimalizacji....
-
Lower bound on the domination number of a tree.
PublicationW pracy przedstawiono dolne ograniczenie na liczbę dominowania w drzewach oraz przedstawiono pełną charakterystykę grafów ekstremalnych.
-
Analysis of loading history influence on fatigue and fracture surface parameters using the method of induction trees
Publication -
The Risk Indicators of Construction Projects’ Cost Overruns Assessed with PCA, Decision Trees, and Pearson’s Correlations
Publication -
Water Needs of Sweet Cherry Trees in the Light of Predicted Climate Warming in the Bydgoszcz Region, Poland
Publication -
Analyzing sets of phylogenetic trees obtained from bayesian MCMC process using topology metrics
PublicationThe reconstruction of evolutionary trees is one of the primary objectives in phylogenetics. Such a tree represents historical evolutionary relationship between different species or organisms. Tree comparisons are used for multiple purposes, from unveiling the history of species to deciphering evolutionary associations amongorganisms and geographical areas.In the paper, we describe a general method for comparing hylogenetic trees....
-
Comparison of Absorbed and Intercepted Fractions of PAR for Individual Trees Based on Radiative Transfer Model Simulations
PublicationThe fraction of absorbed photosynthetically active radiation (fAPAR) is a key parameter for estimating the gross primary production (GPP) of trees. For continuous, dense forest canopies, fAPAR, is often equated with the intercepted fraction, fIPAR. This assumption is not valid for individual trees in urban environments or parkland settings where the canopy is sparse and there are well-defined tree crown boundaries. Here, the distinction...
-
On trees with double domination number equal to 2-outer-independent domination number plus one
PublicationA vertex of a graph is said to dominate itself and all of its neighbors. A double dominating set of a graph G is a set D of vertices of G such that every vertex of G is dominated by at least two vertices of D. The double domination number of a graph G is the minimum cardinality of a double dominating set of G. For a graph G=(V,E), a subset D subseteq V(G) is a 2-dominating set if every vertex of V(G)D has at least two neighbors...
-
Condition monitoring and fault diagnosis of wind turbines based on structural break detection in SCADA data
Publication -
Elimination of the negative effect of earth fault current higher frequency on tripping of residual current devices
PublicationCzęstotliwość prądu różnicowego większa niż 50/60 Hz ma niekorzystny wpływ na wyzwalanie wyłączników różnicowoprądowych. Przy zwiększonej częstotliwości prądu różnicowego rzeczywisty prąd zadziałania wyłączników zwiększa się, a niektóre z nich w ogóle nie wyzwalają. W artykule omówiono główne przyczyny zwiększenia się prądu zadziałania wyłączników różnicowoprądowych oraz przedstawiono sposób eliminacji niekorzystnego wpływu zwiększonej...
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Novel Investigation of Higher Order Spectral Technologies for Fault Diagnosis of Motor-Based Rotating Machinery
PublicationIn the last decade, research centered around the fault diagnosis of rotating machinery using non-contact techniques has been significantly on the rise. For the first time worldwide, innovative techniques for the diagnosis of rotating machinery, based on electrical motors, including generic, nonlinear, higher-order cross-correlations of spectral moduli of the third and fourth order (CCSM3 and CCSM4, respectively), have been comprehensively...
-
Fault diagnosis in electronic circuits based on bilinear transformation in 3-D and 4-D spaces
PublicationPrzedstawiono ideę nowych metod diagnostycznych 3-D i 4-D opartych na przek-ształceniu biliniowym. Metody te bazują na transformacjach operujących odpo-wiednio w trzy i czterowymiarowych przestrzeniach funkcji układowych. Dlatych metod omówiono algorytm lokalizacji i identyfikacji pojedynczych uszko-dzeń parametrycznych w liniowych układach elektronicznych oraz algorytm lo-kalizacji i identyfikacji pojedynczych uszkodzeń...
-
Fast Real-Time RDFT- and GDFT-Based Direct Fault Diagnosis of Induction Motor Drive
PublicationThis paper presents the theoretical analysis and experimental verification of a direct fault harmonic identification approach in a converter-fed electric drive for automated diagnosis purposes. On the basis of the analytical model of the proposed real-time direct fault diagnosis, the fault-related harmonic component is calculated using recursive DFT (RDFT) and Goertzel DFT (GDFT), applied instead of the full spectrum calculations...
-
On extremal sizes of locally k-tree graphs
PublicationA graph G is a locally k-tree graph if for any vertex v the subgraph induced by the neighbours of v is a k-tree, k>=0, where 0-tree is an edgeless graph, 1-tree is a tree. We characterize the minimum-size locally k-trees with n vertices. The minimum-size connected locally k-trees are simply (k + 1)-trees. For k >= 1, we construct locally k-trees which are maximal with respect to the spanning subgraph relation. Consequently, the...
-
Incremental construction of Minimal Tree Automata [online]
PublicationWe describe an algorithm that allows the incremental addition or removal of unranked ordered trees to minimal frontier-to-root deterministic tree automaton (DTA). The algorithm takes a tree t and a minimal DTA A as input; it outputs a minimal DTA A' which accepts the language L(A) accepted by A incremented (or decremented) with the tree t. The algorithm can be used to efficiently maintain dictionaries which store large collections...