Wyniki wyszukiwania dla: LOW-VOLTAGE ELECTRICAL INSTALLATIONS
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublikacjaThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Protection against electric shock in electrical installations with low voltage generating sets
PublikacjaW referacie przedstawiono zasady ochrony przeciwporażeniowej, zgodne z wymaganiami międzynarodowymi, w sytuacji kiedy instalacja elektryczna jest zasilana z niskonapięciowych zespołów prądotwórczych. Zwrócono uwagę na dobór zabezpieczeń przeciwporażeniowych oraz na wymiarowanie uziemień.
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Blended Learning in Teaching Safety of Electrical Installations
PublikacjaBlended learning becomes more commonly used in teaching information technology or other subjects, which involve practice in computer laboratories. In case of subjects with no access to computer rooms blended learning supports lecturing and teaching classes e.g. interactive lessons. The article presents the use of blended learning forms in Gdansk University of Technology in teaching the subject of Safety of Electrical Installations....
-
Evaluation of fire hazard in electrical installations due to unfavorable ambient thermal conditions
PublikacjaEvaluation of fire hazard caused by electrical installations is a difficult and important topic, and it limits the possibility of loss of life or health of people, as well as the occurrence of significant property damage. In particular, this hazard was caused by power cables and especially photovoltaic (PV) installations. The authors proved that power cables directly exposed to strong solar radiation are likely to exceed maximum...
-
Modern power-electronics installations in the Polish electrical power network
PublikacjaThe paper discusses the most important areas of application of power electronics arrangements in the Polish electrical power system; especially in the distribution system. The examples presented demonstrate both the need for and the purpose of further research and its applications in these fields, as well as indicating the direction of future research, with special consideration given to the research required in Poland. The proposed...
-
Application of residual current devices in electrical installations with frequency converters
PublikacjaW instalacjach elektrycznych, w których znajdują się przemienniki częstotliwości mogą pojawić się prądy zwarcia doziemnego o różnej częstotliwości lub stałe. Większość wyłączników różnicowoprądowych nie reaguje na tego typu prądy, co powoduje, że ochrona przeciwporażeniowa jest nieskuteczna. W obwodach z przemiennikami częstotliwości mogą pojawiać się przejściowe i ustalone prądy upływowe o znacznych wartościach. Prądy te znacząco...
-
Evaluation of Fire Hazard in Electrical Installations Due to Unfavorable Ambient Thermal Conditions
Publikacja -
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublikacjaThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Critical evaluation of resonaut gc voltage link inventures for electrical drives.
PublikacjaPrzedstawiono wyniki modelowania i symulacji falowników z centralnym obwodem rezonansowym dla zastosowań w napędzie elektrycznym. Porównano struktury ukladów z rezonansowym równoległym obwodem pośredniczącym o ograniczonej wartości szczytowej i uasi-rezonansowych. Dla potrzeb projektowania tych układów, wobec przeciwstawnych funkcji celu dokonano ich wielokrytycznej oceny.
-
Design of hight voltage busbar: trade off between electrical field and stray inductance
PublikacjaArtykuł dotyczy optymalizacji konstrukcji i technologii szyny doprowadzenia zasilania do pojedynczej gałęzi falownika średniego napięcia. Dla szeregowego układu złożonego z trzech modułów elektroizolowanych (6 par tranzystorów i diod) rozważono warianty geometrii szyny zasilania przy uwzględnieniu wypadkowej indukcyjności obwodu komutacyjnego. Wyznaczono główne składniki indukcyjności rozproszenia oraz wykazano jej wpływ na przepięcia...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublikacjaEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Stanisław Galla dr inż.
OsobyUrodził się w 1970 w Gdańsku. Jest absolwentem Technikum Mechaniczno Elektrycznego w Gdańsku (1990). Studiował na Wydziale Elektrotechniki Politechniki Gdańskiej (studia ukończył w 1996). Rozprawę doktorską pt. „Metodyka zwiększania dokładności pomiarów małoczęstotliwościowych wskaźników zaburzeń okresowych występujących w sieciach niskiego napięcia” obronił w 2009 r na Wydziale Elektrotechniki i Automatyki Politechniki Gdańskiej....
-
Behavior of residual current devices at earth fault currents with DC component
PublikacjaLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Time-current tripping characteristics of RCDs for sinusoidal testing current
PublikacjaLow-voltage electrical installations are verified initially – before being put into operation, as well as periodically – during their utilization. According to the IEC standards, the scope of the verification includes measurements of both the tripping current and the disconnection time of residual current devices (RCDs). Experiences in RCDs testing show that disconnection times of two or more similar RCDs can be quite different....
-
Tripping of F-type RCDs for high-frequency residual currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublikacjaRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublikacjaW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
Quality assessment of low voltage surge arresters
PublikacjaUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Dielectric Barrier Discharge Systems with HV Generators and Discharge Chambers for Surface Treatment and Decontamination of Organic Products
PublikacjaThe article presents applications of systems with power electronic converters, high voltage transformers, and discharge chambers used for nonthermal, dielectric barrier discharge plasma treatment of a plastic surface and decontamination of organic loose products. In these installations, the inductance of the high voltage transformers and the capacitances of the electrode sets form resonant circuits that are excited by inverters....
-
Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component
PublikacjaRecent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublikacjaIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
The Influence of a Photovoltaic Micro-Installation on the Low-Frequency Parameters of Electricity at PCC and Its Impact on the Thermal Characteristics of Selected Devices
PublikacjaThis manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking...
-
Low speed permanent magnet synchronous generator for vertical axis wind turbine
PublikacjaThe paper presents design process and tests of a prototype low speed permanent magnet synchronous generator (PMSG) dedicated for the innovative vertical-axis wind turbine. The rated data of the designed generator are following: power - 15 kVA, voltage - 400 V (Y), rotation speed - 93.75 rpm. The design assumptions, chosen results of the design process and experimental tests of the prototype PMSG are presented. The considered PMSG...
-
Assessment of the factors influencing on the formation of energy-oriented modes of electric power consumption by water-drainage installations of the mines
PublikacjaPurpose. Performing the analysis to determine energy-efficient modes and assess the characteristics of the main indicators of electric power consumption by mine water-drainage installations based on the developed research mathematical model. Methods. To achieve the purpose set, a methodology is used to develop the multiple multifactor correlation-regression modeling with respect to the modes of electric power consumption by electrical...
-
Power electronic transformer based on cascaded H-bridge converter
PublikacjaIn this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...
-
Tripping limitations of residual current devices in photovoltaic installations
PublikacjaIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Low-frequency tripping characteristics of residual current devices
PublikacjaFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
AC Motor Voltage and Audible Noise Dataset
PublikacjaThe dataset titled AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters contains the voltage and sound measurement results recorded in a marine frequency controlled AC drive system. The dataset is part of research focussing on the impact of the ship’s electrical drive systems with frequency converters on vibrations and the level of audible noise on ships. The dataset allows the...
-
Electro-optical transducer based on indium-tin-oxide-coated optical fiber for analysis of ionized media
PublikacjaThe paper introduces a concept of an optical fiber based electro-optical transducer for monitoring of ionized media, such as low-temperature plasma. It utilizes optical fiber with a section of a core coated with tailored indium tin oxide (ITO) thin film and thus combines the optical phenomena of lossy-mode resonance (LMR) with the electrostatic probe. ITO is an optically transparent and electrically conductive material and if its...
-
The Possibility of Phase Change Materials (PCM) Usage to Increase Efficiency of the Photovoltaic Modules
PublikacjaSolar energy is widely available, free and inexhaustible. Furthermore this source of energy is the most friendly to the environment. For direct conversion of solar energy into useful forms like of electricity and thermal energy, respectively photovoltaic cells and solar collectors are being used. Forecast indicate that the first one solution will soon have a significant part in meeting the global energy demand. Therefore it is...
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublikacjaThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Quality assessment of ZnO-based varistors by 1/f noise
PublikacjaNoise has been used as a diagnostic tool of surge arrester varistor structures comprising of ZnO grains of various type and size. The physical and electrical properties of the measured samples have been described. In the experimental study, the applied measurement system and the results of noise measurements for the selected structures of varistors designed for the continuous working voltage 280 V, 440 V and 660 V have been presented....
-
Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements
PublikacjaWe proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...
-
Exercise bike powered electric generator for fitness club appliances
PublikacjaA generator powered by a stationary bicycle for the purposes of generating electricity for fitness club appliances is considered. A generator is connected to a stationary bicycle in such a way as the circular rotation of the front wheel rotates the coils of wires inside the generator between the poles of the magnets inside the generator. The resulting Direct Current is channeled to the attached battery bank and converted into different...
-
PV installations and the safety of residential buildings
PublikacjaThe dynamic development of the photovoltaic industry entails threats that have a direct impact on the safety of residential buildings. Appropriate design of a PV installation can be a challenge due to the multifaceted nature of this issue. The designer should take into account issues related to the selection of electrical parameters of the installation, adapting lightning and surge protection in accordance...
-
Metody doboru miejsc zainstalowania zasobników energii w sieciach elektroenergetycznych niskiego napięcia
PublikacjaW związku z rosnącą liczbą źródeł odnawialnych przyłączanych do sieci niskiego napięcia (nn) jakość energii elektrycznej w tej sieci ulega pogorszeniu. Jedną z metod jej poprawiania jest instalowanie zasobników energii, tj. baterii akumulatorów, superkondensatorów czy kół zamachowych. Zasobniki energii są w stanie złagodzić dobową zmienność obciążenia, skompensować moc bierną i wyższe harmoniczne oraz zmniejszyć asymetrię obciążenia...
-
Propagation Characteristics of Partial Discharges in an Oil-Filled Power Transformer
PublikacjaPower transformers are among the most important assets in the power transmission and distribution grid. However, they suffer from degradation and possible faults causing major electrical and financial losses. Partial discharges (PDs) are used to identify the insulation health status and their degradation level. PDs are incipient, low-magnitude faults caused by localized dielectric breakdown. Those activities emit signals in many...
-
Synthesis and Testing of BCZY/LNZ Mixed Proton–electron Conducting Composites for Fuel Cell Applications
PublikacjaA composite of BaCe0.6Zr0.2Y0.2O3–δ and Li2O:NiO:ZnO was investigated for fuel cell applications. The composite was successfully synthesized and its phase stability was confirmed at temperatures up to 900 °C. The influence of sintering and pressing aids on density was also investigated. Electrical properties were measured. DC electrical conductivity was about 8•10-4 S/m at 845 K. Open circuit voltage measurements in wet hydrogen...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublikacjaAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Inception and Propagation of Electrical Trees in the Presence of Space Charge in HVAC Extruded Cables
PublikacjaThis paper presents the space charge impact on the inception and propagation of electrical trees in cross-linked polyethylene (XLPE) insulation via simulations and experimentation. A 3D finite element analysis (FEA)-based modeling is proposed to simulate electrical trees via a needle embedded on the XLPE insulation. The proposed FEA model demonstrates the influence of the space charge magnitude and polarity on the initiation of...
-
Control system for contactless electrical energy transfer with varying air gap
PublikacjaInductive power transfer (IPT) is a system by which electrical energy may be transmitted without electrical connection through a large air gap between coils. Systems usually considered in the literature are the ones with a constant air gap. The paper describes the analysis of IPT, which allows for supplying an electrical load in the conditions of slow, in relation to the dynamics of power supply, changes in the dimensions of the...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublikacjaIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
The effect of current delay angle on tripping of residual current devices
PublikacjaPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublikacjaThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Electromagnetic-based derivation of fractional-order circuit theory
PublikacjaIn this paper, foundations of the fractional-order circuit theory are revisited. Although many papers have been devoted to fractional-order modelling of electrical circuits, there are relatively few foundations for such an approach. Therefore, we derive fractional-order lumped-element equations for capacitors, inductors and resistors, as well as Kirchhoff’s voltage and current laws using quasi-static approximations of fractional-order...
-
Performance Evaluation of a 650V E-HEMT GaN Power Switch
PublikacjaGaN power switches have better characteristics compared to the state-of-the-art Si power transistors. These devices offer high operating temperature and current densities, fast switching and low on-resistance. However, currently only a few producers offer technology of high voltage GaN transistors. Immaturity of this technology is the reason why experimental evaluation of GaN parameters must be performed to properly exploit their...
-
The Influence of LED Lighting Sources on the Nature of Power Factor
PublikacjaThis article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...
-
On analog comparators for CMOS digital pixel applications. A comparative study
PublikacjaVoltage comparator is the only – apart from the light-to-voltage converter – analog component in the digital CMOS pixel. In this work, the influence of the analog comparator nonidealities on the performance of the digital pixel has been investigated. In particular, two versions of the digital pixel have been designed in 0.35 μm CMOS technology, each using a different type of analog comparator. The properties of both versions have...
-
Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse
Publikacjahe development of renewable energy, including wind farms, photovoltaic farms as well as prosumer installations, and the development of electromobility pose new challenges for network operators. The results of these changes are, among others, the change of network load profiles and load flows determining greater volatility of voltages. Most of the proposed solutions do not assume a change of the transformer regulator algorithm....
-
Effects of thermal history on the performance of low-temperature solid oxide fuel cells with Sm0.2Ce0.8O2-δ electrolyte and LiNi0.81Co0.15Al0.04O2 electrodes
PublikacjaIn this study, low-temperature solid oxide fuel cells with an ∼560 μm thick Sm0.2Ce0.8O2−δ (SDC) electrolyte and ∼890 μm thick LiNi0.81Co0.15Al0.04O2−δ (NCAL) electrodes are constructed and characterized under three experimental conditions. The cell with an NCAL cathode pre-reduced under an H2 atmosphere at 550 °C presents the best electrochemical performance. This is ascribed to facts that the reduction reaction generating Ni–Co...
-
Multifaceted Analyses of Four Different Prototype Lightweight Photovoltaic Modules of Novel Structure
PublikacjaDynamic growth of photovoltaic capacity in Poland encourages many entities to invest in photovoltaic systems. However, in the case of buildings with low roof-bearing capacity it can be problematic or even impossible to mount conventional PV modules due to their relatively high weight. Hence, the use of lightweight PV modules is a potential solution. In this paper four different prototype silicon lightweight modules of novel structure...
-
Improving voltage levels in low-voltage networks with distributed generation – case study
PublikacjaThe use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...
-
Magnetic field microsensor based on GaAs MESFET
PublikacjaA novel concept of the drain separation design in a horizontally-split-drain GaAs MAGFET sensor, based on epitaxial layer growth, was developed. Proper choice of GaAs/AlAs/GaAs epitaxial layer sequence provided good electrical isolation between the drain regions. The measured leakage current between the drain regions was in the range of nA for up to 2V drain voltage bias difference. Performed analytical and numerical calculations...
-
BPL-PLC Voice Communication System for the Oil and Mining Industry
PublikacjaApplication of a high-efficiency voice communication systems based on broadband over power line-power line communication (BPL-PLC) technology in medium voltage networks, including hazardous areas (like the oil and mining industry), as a redundant mean of wired communication (apart from traditional fiber optics and electrical wires) can be beneficial. Due to the possibility of utilizing existing electrical infrastructure, it can...
-
Assessment of copper surface coverage with corrosion inhibitor using AFM-based local electrical measurements
PublikacjaThe paper presents a new method of assessment of metal surface coverage with corrosion inhibitor and thus of inhibitor protective performance. It is based on the atomic force microscopy measurement performed in a contact mode. Apart from topography images the proposed approach allows acquisition of local DC maps and local electrical impedance spectra via application of DC bias voltage or AC perturbation signal between the conductive...
-
A review on analytical models of brushless permanent magnet machines
PublikacjaThis study provides an in-depth investigation of the use of analytical and numerical methods in analyzing electrical machines. Although numerical models such as the finite-element method (FEM) can handle complex geometries and saturation effects, they have significant computational burdens, are time-consuming, and are inflexible when it comes to changing machine geometries or input values. Analytical models based on magnetic equivalent...
-
Organic Vapor Sensing Mechanisms by Large-Area Graphene Back-Gated Field-Effect Transistors under UV Irradiation
PublikacjaThe gas sensing properties of graphene back-gated field-effect transistor (GFET) sensors toward acetonitrile, tetrahydrofuran, and chloroform vapors were investigated with the focus on unfolding possible gas detection mechanisms. The FET configuration of the sensor device enabled gate voltage tuning for enhanced measurements of changes in DC electrical characteristics. Electrical measurements were combined with a fluctuation-enhanced...
-
Fractional Order Circuit Elements Derived from Electromagnetism
PublikacjaIn this paper, derivations of fractional-order (FO) circuit-element equations from electromagnetism are presented. Whilst many papers are devoted to FO modelling of electrical circuits, there are no strong foundations for such an approach. Therefore, we investigate relations between the FO electromagnetism and the FO circuit theory. Our derivations start from quasi-static (QS) approximations of Maxwell's equations in media with...
-
Impact of Tensile and Compressive Stress on Classical and Acoustic Barkhausen Effects in Grain-Oriented Electrical Steel
PublikacjaIn this paper, we present the results of the investigation of impact of tensile and compressive stress on the classical Barkhausen effect, magnetoacoustic emission (MAE) signal properties, and B(H) hysteresis loops for grain-oriented (GO) electrical steel. Samples have been glued to a nonmagnetic steel bar and stressed within elastic range (±800 μdef) by means of four-point bending method. The samples were cut out in two directions...
-
Remote current measurement with FPGA digital processing
PublikacjaThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Electrical equipment and installations [2023/2024]
Kursy Online -
Multipulse inverter structures with low voltage distortion
PublikacjaA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Application of wet powder spraying for anode supported solid oxide fuel cell with a perowskite SrTi0.98Nb0.02O3-d anode
PublikacjaAnode-supported solid oxide fuel cell with SrTi0.98Nb0.02O3–d anode, yttria-stabilized zirconia electrolyte and La(Ni0.6Fe0.4) O3d cathode has been successfully fabricated and evaluated. Process of anode support fabrication has been presented. Wet powder spraying and high temperature sintering method have been studied and applied to deposit the thin electrolyte layer.In order to improve catalytic properties of the anode, it has...
-
Power Electronic Transformer For Smart Grid Application
PublikacjaIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
Practical aspects of testing superconducting electromagnets by the capacitor discharge method taking into account the non-linearity of circuit parameters
PublikacjaThe article presents selected issues related to the development and testing of the diagnostics systems dedicated for superconducting electromagnets. The systems were constructed to assess the production quality of superconducting electromagnets of the SIS100 synchrotron, a new accelerator being built as part of the Facility of Antiproton and Ion Research (FAIR). One of the systems is used for automatic checking of electrical connection...
-
Low harmonic multipulse voltage converters using coupled reactors
PublikacjaThis paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...
-
Detection of inter-turn faults in transformer winding using the capacitor discharge method
PublikacjaThe paper presents results of an analysis of inter-turn fault effects on the voltage and current waveforms of a capacitor discharge through transformer windings. The research was conducted in the frame of the Facility of Antiproton and Ion Research project which goal is to build a new international accelerator facility that utilizes superconducting magnets. For the sake of electrical quality assurance of the superconducting magnet...
-
Nitrogen-Incorporated Boron-Doped Nanocrystalline Diamond Nanowires for Microplasma Illumination
PublikacjaThe origin of nitrogen-incorporated boron-doped nanocrystalline diamond (NB-NCD) nanowires as a function of substrate temperature (Ts) in H2/CH4/B2H6/N2 reactant gases is systematically addressed. Because of Ts, there is a drastic modification in the dimensional structure and microstructure and hence in the several properties of the NB-NCD films. The NB-NCD films grown at low Ts (400 °C) contain faceted diamond grains. The morphology...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublikacjaLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Use of AMI Meters in the Process of Low Voltage Grid Optimization
PublikacjaThis is a report of a project involving, inter alia, low voltage grid performance optimization with data from AMI meters . The study was supported with a European UPGRID grant, and executed by a consortium of companies from seven European countries, including Poland .
-
NEW SOLUTIONS FOR THE SOLAR CHARGE CONTROLLERS DESIGN FOR OBTAINING TRUE MPP IN PARTLY SHADED PV MODULES
PublikacjaSoft shading sources such as tree limbs, structural elements of buildings and chimneys, scatter and refract sunlight, significantly reducing the amount of radiation reaching the surface of the module. The hard shadings located directly on the surface (i.e. bird droppings, leaves, snow) tend to stop sunlight completely. These phenomena significantly affects the output characteristics of photovoltaic modules and often contribute...
-
Modeling and Evaluation of Electric Treeing Phenomena in Polymeric Cable Insulation
PublikacjaThis paper investigates the treeing phenomenon in polymeric materials such as crosslinked polyethylene (XLPE) that is widely used in medium and high voltage power cables as primary insulation. The modeling of electrical tree growth in the insulation from its initiation to breakdown is significant research work that illustrates the discharge dynamics and its impact on aging process in polymeric insulation. This study utilizes pulse...
-
Performance of acicular grindable thermocouples for temperature measurements at sliding contacts
PublikacjaThe present study investigates the performance of acicular grindable thermocouples based on a constantan wire / steel hollow cylinder construction. The experiments showed that the measuring junction electrical resistance, temperature–voltage characteristic, measuring junction rise time and signal noise standard deviation of the acicular thermocouples are comparable to those of conventional J-type thermocouples with bare wire diameter...
-
Nonlinear and linear impedance of bismuth vanadate ceramics and its relation to structural properties
PublikacjaThe nonlinear and linear electrical properties, topography, and microstructure of bismuth-vanadate ceramics, were studied. The structurewas observed with the use of X-ray diffraction (XRD), scanning electronmicroscopy (SEM), atomic force microscopy (AFM) and confocal microscopy methods. The obtained results showed that ceramic is porous. Two phase transitionswere determinedwith the use of DSC measurements. The linear and nonlinear ac...
-
Medium-Voltage Drives: Challenges and existing technology
PublikacjaThe article presents an overview of state-of-art solutions, advances, and design and research trends in medium-voltage (MV) drive technologies - and also discusses the challenges and requirements associated with the use of such drives. The choice and deployment of MV drives in industries are associated with numerous requirements related to the front-end converter (grid side) and inverter (machine side). The focus is on solutions...
-
Modeling the impact of rotor movement on non-linearity of motor currents waveforms in high-speed PMSM drives
PublikacjaMotor current measurement techniques as well as predictive control algorithms for electric drives rely on an assumption of linear motor currents changes resulting from constant inverter output voltages. Recent research has reported that this assumption does not hold in motors with short electrical time constant, and in drives whose rotor position advances substantially during a control period. This paper proposes a simulation model...
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublikacjaIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Nonlinear Model of Synchronous Generator for Autonomous Electrical Power Systems Analysis
PublikacjaThis paper presents the nonlinear lookup table model for synchronous generator (SG) analysis. The saturation effects of the SG magnetic circuit have been considered. The saturated characteristic of the SG magnetic circuit are based on the open circuit saturation curve for magnetizing inductances. The model has been implemented into the Synopsys/Saber software using the MAST modelling language. To implement the no-load voltage characteristic...
-
The effect of boron concentration on the electrical, morphological and optical properties of boron-doped nanocrystalline diamond sheets: Tuning the diamond-on-graphene vertical junction
PublikacjaIn this paper, the effect of boron doping on the electrical, morphological and structural properties of free-standing nanocrystalline diamond sheets (thickness ~ 1 μm) was investigated. For this purpose, we used diamond films delaminated from a mirror-polished tantalum substrate following a microwave plasma-assisted chemical vapor deposition process, each grown with a different [B]/[C] ratio (up to 20,000 ppm) in the gas phase....
-
PARAMETERS OF THE ELECTROPHORETIC DEPOSITION PROCESS AND ITS INFLUENCE ON THE MORPHOLOGY OF HYDROXYAPATITE COATINGS. REVIEW
PublikacjaMetallic materials intended for bone implants should exhibit not only appropriate mechanical properties, but also high biocompatibility. The surface treatment modifications, for example acidic treatment, laser treatment, ion implantation and deposition of highly biocompatible coatings, are practiced. One of the most popular methods of surface modification is to deposit hydroxyapatite (HAp) coatings. HAp naturally occurs in human...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublikacjaAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublikacjaCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response
PublikacjaIn this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublikacjaThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Magnetoelectric effect in (BiFeO3)x–(BaTiO3)1-x solid solutions
PublikacjaThe aim of the present work was to study magnetoelectric effect (ME) in (BiFeO3)x–(BaTiO3)1x solid solutions in terms of technological conditions applied in the samples fabrication process. The rapidly growing interest in these materials is caused by their multiferroic behaviour, i.e. coexistence of both electric and magnetic ordering. It creates possibility for many innovative applications, e.g. in steering the magnetic memory...
-
Investigation of praseodymium and samarium co-doped ceria as an anode catalyst for DIR-SOFC fueled by biogas
PublikacjaThe Pr and Sm co-doped ceria (with up to 20 mol.% of dopants) compounds were examined as catalytic layers on the surface of SOFC anode directly fed by biogas to increase a lifetime and the efficiency of commercially available DIR-SOFC without the usage of an external reformer. The XRD, SEM and EDX methods were used to investigate the structural properties and the composition of fabricated materials. Furthermore, the electrical...
-
The harmonic distortion of voltage waveforms in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the ship's electrical power system's main switchboard in different states of ship exploitation. The attached dataset contains the results of a harmonic distortion analysis expressed by the total harmonic distortion (THD) coefficient of voltage waveforms recorded...
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublikacjaCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Effect of soil moisture on current-carrying capacity of low-voltage power cables
PublikacjaOne of the factors affecting current-carrying capacity of underground power cables is the thermal resistivity of soil. Its value in the close proximity of the cable is the most important, and for this reason, in some cases, the local soil is replaced with an another soil type or with a cement-sand mixture. The thermal resistivity of the soil is strongly affected by moisture, and in the case of a cement-sand mixture – as tested...
-
Low voltage photovoltaic power system
PublikacjaThe use of photovoltaics is growing rapidly in the industry as well as households. Therefore, educating the public will help them understand solar cell technology, which is becoming more common in everyday life. This paper proposes a demonstrational set-up of photovoltaic panel for the purpose of science education. It was used in numerous outreach activities such as science fairs. Moreover, it proved to be a great tool for education...
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublikacjaThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Exploring the interfacial effects at the ETL/perovskite boundary in the semitransparent perovskite solar cells
PublikacjaThe recent focus has been made on the perovskite solar cells (PSCs) with an inverted configuration, where substantial improvements have been already achieved. However, the p–i–n structure needs a buffer layer for most of the configurations to modify the work-function of a deposited electrode. Additionally and very importantly, such a layer can also serve as a protective film that improves a stability of solar cells. Here, we study...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during maneuvering.
-
The scanning electron microscopy (SEM) studies of low voltage copper cables
Dane BadawczeThe dataset contains the scanning electron microscopy (SEM) images of the low voltage copper cables, which were studied in the article discussing the regulatory requirements for checking the electrical resistance of such cables. The cables were cut and studies in cross-section. The full results were published in: