Filters
total: 2082
filtered: 1270
displaying 1000 best results Help
Search results for: ION-SELECTIVE ELECTRODES · MULTISENSOR SYSTEM · POTENCTIOMETRIC MEASUREMENTS · REFERENCE ELECTRODE
-
Tin oxide nanoparticles from laser ablation encapsulated in a carbonaceous matrix – a negative electrode in lithium-ion battery applications
PublicationThis report concerns carbonaceous electrodes doped with tin(II) oxide nanoparticles. Tin nanoparticles are obtained by pulsed laser ablation in water. Crystalline nanoparticles have been encapsulated in a carbonaceous matrix formed after pyrolysis of a mixture consisting of tin/tin(IV) oxide nanoparticles and gelatine. The obtained material is characterized by means of X-ray diffraction, selected area diffraction, scanning electron...
-
Multifrequency Nanoscale Impedance Microscopy (m-NIM): A novel approach towards detection of selective and subtle modifications on the surface of polycrystalline boron-doped diamond electrodes
PublicationIn this paper, we describe the modification of Nanoscale Impedance Microscopy (NIM), namely, a combination of contact-mode atomic force microscopy with local impedance measurements. The postulated approach is based on the application of multifrequency voltage perturbation instead of standard frequency-by-frequency analysis, which among others offers more time-efficient and accurate determination of the resultant impedance spectra...
-
Study of oxygen electrode reactions on symmetrical porous SrTi0.30Fe0.70O3-δ electrodes on Ce0.8Gd0.2O1.9 electrolyte at 800 °C–500 °C
PublicationIron doped strontium titanates (SrTi1-xFexO3-δ) are an interesting mixed ionic-electronic conductor model used to study basic oxygen reduction/oxidation reactions. In this work, we performed an impedance spectroscopy study on symmetrical porous SrTi0.30Fe0.70O3-δ (STF70) electrodes on a ceriabased electrolyte. The sample was measured in varying oxygen concentration: from 0.3% to 100% in 800 °C - 500 °C temperature range. Low polarisation...
-
Ionophores in polymeric membranes for selective ion recognition; impedance studies
PublicationBadania impedancyjne membran zawierających jonofory selektywne na kation Na+ (L1) i Cs+(L2) wykazały, ze stala dielektryczna materiału membrany zależy od typu uzytego plastyfikatora i zmienia się w zakresie od 28 do 60. Rezystancja membran zawierających ligand L1 i L2 wynosi 0.15 -1.4 Mohm w zależności od stężenia elektrolitu zewnnetrznego. Testowona dwa typy elektrod jonoselektywnych: elektrody typu ASS z polimerem przewodzącym...
-
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
PublicationIn this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations....
-
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Highly selective impedimetric determination of Haemophilus influenzae protein D using maze-like boron-doped carbon nanowall electrodes
PublicationThis study reports a novel impedimetric immunosensor for protein D detection in purified and bacterial (Haemophilus influenzae, Hi) samples. The detection was based on antigen recognition by anti-protein D antibodies (apD) immobilised at the maze-like boron-doped carbon nanowall electrodes (B:CNW). The B:CNW electrodes were synthesised, and their surface was characterised by scanning electron microscopy (SEM) and X-ray photoelectron...
-
Digital harmonic analysis of cadmium ion reduction on a dropping mercury electrode
PublicationBadano redukcję jonów kadmu na rtęciowej elektrodzie kroplowej. Jako pobudzenie zastosowano sinusoidalny sygnał napięciowy nałożony na liniowo zmieniający się potencjał dc. Przeprowadzono analizę czasowo-częstotliwościową prądu polarograficznego dla reakcji redukcji jonu kadmu na rtęciowej elektrodzie kroplowej. Klasyczna transformacja Fouriera prowadzi do dekompozycji prądu polarograficznego na składowe harmoniczne. Harmoniczne...
-
Solid-phase microextraction and ion chromatographic analysis of anions based on polypyrrole electrode
Publication -
Transmission Quality Measurements in DAB+ Broadcast System
PublicationIn the age of digital media, delivering broadcast content to customers at an acceptable level of quality is one of the most challenging tasks. The most important factor is the efficient use of available resources, including bandwidth. An appropriate way of managing the digital multiplex is essential for both the economic and technical issues. In this paper we describe transmission quality measurements in the DAB+ broadcast system....
-
Development of the System Assurance Reference Model for Generating Modular Assurance Cases
PublicationAssurance cases are structured arguments used to demonstrate specific system properties such as safety or security. They are used in many industrial sectors including automotive, aviation and medical devices. Larger assurance cases are usually divided into modules to manage the complexity and distribute the work. Each of the modules is developed to address specific goals allocated to the specific objects i.e. components of the...
-
Lower rim substituted tert-Butylcalix[4]arenes. Part 13. Interaction of calix-hydroxamates with Fe(III) and Pb(II); studies in ion-selective membrane electrodes (ISE)
PublicationPrzedmiotem pracy są badania oddziaływań pomiędzy trzema wybranymi hydroksamowymi pochodnymi t-butylo-kaliks[4]arenu i jonami metali z wykorzystaniem membranowych elektrod jonoselektywnych (ISE). Elektrody zawierające jako materiał aktywny wymienione związki jonoforowe charakteryzują się nernstowskim nachyleniem i szerokim zakresem liniowości na jony Pb(II), a także dobrą selektywnością na jony Pb(II)w stosunku do jonów UO2(II),...
-
Pitting corrosion characterization by electrochemical noise measurements on asymmetric electrodes
PublicationKorozja wżerowa stali nierdzewnych może być wykryta za pomocą obserwacji charakterystycznych sygnałów prądowych, jakie płyną między dwiema elektrodami metalowymi. W artykule proponuje się wyznaczanie funkcji bispektrum dla układu dwóch elektrod o istotnie różnej powierzchni narażonej na występowanie korozji. Proponowana metoda została zastosowana do analizy korozji wżerowej stali 0H18N9 powstającej pod wpływem 1M roztworu FeCl3...
-
Lower Rim Substitutedp-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based onp-tert-Butyl-calix[4]arene Thioamides
Publication -
Carbon nanotubes decorated by mesoporous cobalt oxide as electrode material for lithium-ion batteries
Publication -
Selective Synthesis of Magnetite Nanospheres with Controllable Morphologies on CNTs and Application to Lithium‐Ion Batteries
Publication -
Tracking body movement for radio channel measurements in BAN with indoor positioning system
PublicationThis paper presents indoor positioning system based on inertial navigation with additional distance measurements using UWB modems and map matching to increase accuracy and eliminate position drift. Such system may be used to track position of human body during radio channel measurements for body area networks. Performance of proposed system and limitations caused by inertial navigation are briefly described.
-
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based on p-tert-Butyl-calix[4]arene Thioamides.
PublicationTetra podstawione tioamidowe pochodne para-tert-butylokaliks[4]arenu (1-5) zostały zastosowane jako jonofory w membranowych elektrodach jonoselektywnych (EJS) selektywne na kationy Pb(II). Wyznaczono współczynniki selektywności. Czwartorzędowe kaliks[4]aren-tioamidy (1,2) wykazują nadzwyczaj dobrą selektywność na kationy Pb(II) w porównaniu z kaliks[4]aren-amidami. Membrany z tymi ligandami wykazują dużą trwałość, a charakterystyki...
-
System setup and software for cyclic, staircase and square wave voltammetry measurements
PublicationHardware dedicated for electrochemical measurement sometimes does not allow performing certain voltammetry experiments. Staircase and square wave voltammetry, techniques which have many advantages comparing with standard voltammetric techniques, are rarely implemented in software controlling electrochemical measuring equipment. These methods, however, can be relatively easy realized with some addition...
-
Accuracy of marine gravimetric measurements in terms of geodetic coordinates of land reference benchmark
Publication -
Distributed System For Noise Threat Evaluation Based On Psychoacoustic Measurements
PublicationAn innovative system designed for the continuous monitoring of acoustic climate of urban areas was presentedin the paper. The assessment of environmental threats is performed using online data, acquired through a grid ofengineered monitoring stations collecting comprehensive information about the acoustic climate of urban areas.The grid of proposed devices provides valuable data for the purpose of long and short time acoustic climateanalysis....
-
Selectivity of lithium electrodes: correlation with ion-ionophore complexstability constants and with interfacial exchange current densities
PublicationMembranowe elektrody selektywne na jony litu oparte na dwóch różnych dicyk-lohesyloamidowych jonoforach poddane zostały systematycznym badaniom. Potencjometrycznie wyznaczono wartości współczynników selektywności. Wartości stałych trwałości kompleksów z jonami litu, sodu i potasu wyznaczono metodą membran "sandwichowych". Transfer ładunków przez membranę oraz przez granicę faz membrana/roztwór badano metodą spektroskopii impedancyjnej....
-
A Low-Cost System for Far-Field Non-Anechoic Measurements of Antenna Performance Figures
PublicationPrototype measurements are the key step in the development of antenna structures. Typically, their far-field characteristics are validated in expensive, dedicated facilities such as open range sites, or anechoic chambers. Despite being necessary for obtaining high-precision data (e.g., for device qualification), the use of costly infrastructure might not be fully justified when the main goal of measurements includes demonstration...
-
Conventional and solid-contact lithium-selective electrodes based on tris(N,N-dicyclohexylamide) neutral ionophore
PublicationKonstruowano jonoselektywne elektrody litowe (Li-ISEs) z membraną polimerową i obojętnym jonoforem tris(N,N-dicycloheksyloamidem) jako: elektrodę konwencjonalną (z wodnym roztworem elektrolitu wewnętrznego) oraz ze stałym kontaktem (polianilina jako przekaźnik jonowo-elektronowy). Charakterystyki obu elektrod (nachylenie i zakres liniowy) są porównywalne. Badana elektroda ze stałym kontaktem wykazuje dobrą stabilność w czasie....
-
The Positioning Accuracy of BAUV Using Fusion of Data from USBL System and Movement Parameters Measurements
PublicationThe article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base...
-
Hard carbon derived from rice husk as low cost negative electrodes in Na-ion batteries
PublicationHere, we report the synthesis of hard carbon materials (RH) made from natural rice husk through a single pyrolysis process and their application as an anode in sodium-ion batteries. The studies show that the electrochemical properties of RHs are affected by the treatment temperatures, which determine the materials morphology, in particular, their degree of graphitization and extent of continuous channels (nanovoids). The latter...
-
Towards Promotion of Graphene/Titania‐Based Electrode via Ultrafast and Self‐Expansion Reduction for Li‐ion Battery
Publication -
Study on the Positioning Accuracy of the GNSS/INS System Supported by the RTK Receiver for Railway Measurements
PublicationCurrently, the primary method for determining the object coordinates is positioning using Global Navigation Satellite Systems (GNSS) supported by Inertial Navigation Systems (INS). The main goal of this solution is to ensure high positioning availability, particularly when access to satellite signals is limited (in tunnels, areas with densely concentrated buildings and in forest areas). The aim of this article is to determine whether...
-
Method and system for disciplining a local reference oscillator by GPS 1PPS signal
Publication -
Oznaczanie tlenu – od metody Winklera do czujników enzymatycznych (Determination of oxygen – from Winkler Method to enzymatic sensor)
PublicationMonitoring of dioxygen levels is of utmost importance from the view-point of life processes, medical diagnostics, nutrition and chemical industries. In all these measurements both low and high levels of this element are important. The common methods for the determination of dioxygen are the Winkler method, Clark electrode and pulsoxymeters. A new, already strong field of research can be now recognized – the development of miniaturized...
-
Simulating Power Generation from Photovoltaics in the Polish Power System Based on Ground Meteorological Measurements—First Tests Based on Transmission System Operator Data
PublicationThe Polish power system is undergoing a slow process of transformation from coal to one that is renewables dominated. Although coal will remain a fundamental fuel in the coming years, the recent upsurge in installed capacity of photovoltaic (PV) systems should draw significant attention. Owning to the fact that the Polish Transmission System Operator recently published the PV hourly generation time series in this article, we aim...
-
Mobile system for on-road measurements of air pollutants
PublicationW pracy zaprezentowano prototyp mobilnej stacji diagnostycznej do pomiarów stężeń typowych zanieczyszczeń powietrza (C6H6, NO2, NOx, CO i CO2) pochodzących z komunikacji w miastach. Nowością proponowanego systemu jest możliwość przeprowadzania pomiarów emisji zanieczyszczeń wzdłuż ciągów komunikacyjnych i w miejscach, w których nie mogą być zastosowane stacjonarne stacje monitoringowe. W proponowanym rozwiązaniu, urządzenie...
-
The fixed state in impedance measurements of a two-step electrode reaction proceeding with accompanying adsorption of an intermediate product
Publication -
Stability evaluation of the marine propulsion unit mechanical system bymeans of vibrations measurements and their analysis.
PublicationIn paper selected issues concerning vibration diagnosis of the mechanical system within marine propulsion units have been given. The analysis of vibration parameters was carried out on the basis of experimental examinations of a real object in which an exceedance of the allowable vibration's level had been observed. In the beginning, the vibration apparatus being on laboratory equipment of the Department of Ship Power Plants of...
-
Stability evaluation of the marine propulsion unit's mechanical system by means of vibration measurements and their analysis
PublicationIn this paper selected issues concerning vibration diagnosis of the mechanical system within marine propulsion units have been given. The analysis of vibration parameters was carried out on the basis of experimental examinations of a real object in which an exceedance of the allowable vibration's level had been observed. In the beginning, the vibration apparatus being on laboratory equipment of the Department of Ship Power Plants...
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublicationCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
-
Low-Cost Open-Hardware System for Measurements of Antenna Far-Field Characteristics in Non-Anechoic Environments
PublicationExperimental validation belongs to the most important steps in the development of antenna structures. Measurements are normally performed in expensive, dedicated facilities such as anechoic chambers, or open-test sites. A high cost of their construction might not be justified when the main goal of antenna verification boils down to demonstration of the measurement procedure, or rough validation of the simulation models used for...
-
Size-controlled synthesis of gold nanoparticles by a novel atmospheric pressure glow discharge system with a metallic pin electrode and a flowing liquid electrode
Publication -
Model reference method and continuous-time system identification in tuning the PID controllers.
PublicationW pracy opisano zagadnienie doboru nastaw sterowników PID w układach regulacji automatycznej. W rozważaniach wzięto pod uwagę zarówno klasyczną strukturę jednopętlowego układu sterowania z regulatorem PID umieszczonym w torze głównym, jak też odmienną realizację I-PD z członem całkującym występującym w torze głównym i sterownikiem proporcjonalno-różniczkującym ulokowanym w dodatkowej pętli sprzężenia zwrotnego. Ponieważ powszechnie...
-
Polish DGPS System: 1995-2018 – Studies of Reference Station Operating Zones
Publication -
Lower Rim Substituted p-tert-Butyl Calix[4]arenes(V). Synthesis of New 5,11,17,22-tetrakis-p-tert-Butyl-25-27-bis(dialkoxyphosphorylmethoxy)calix[4] arenes and Cation Complexation Studies in Ion Selective Membrane Electrodes.
PublicationZaprezentowano syntezę i właściwości trzech nowych związków (2-4), bis podstawionych na dolnym obrzeżu grupami z resztą fosforylową. Związki te były badane jako jonofory w membranowych elektrodach jonoselektywnych (ISE) wykazując selektywność na kationy Rb+,K+ oraz duży i płaski kation guanidyniowyG+). Badano korelację pomiędzy stereo-strukturą związków a ich selektywnością w ISE. Stałe trwałości kompleksów z kationami metali...
-
Camera-based Automatic System for Tool Measurements and Recognition
Publication -
Verification of multiband system for non-contact emissivity measurements
PublicationW pracy przeprowadzono weryfikację wielopasmowej pasywnej metody pomiaru emisyjności obiektu na drodze eksperymentalnej. W oparciu o zrealizowane stanowisko pomiarowe dokonano pomiarów emisyjności wybranych obiektów. Uzyskano dobrą zgodność wyników pomiarów z wynikami wcześniejszej komputerowej analizy systemu. Potwierdziło to przydatność wielopasmowej metody do pomiaru emisyjności w warunkach roboczych.
-
Pitting corrosion characterization by electrochemical noise measurements on asymmetric electrodes. [DOI 10.1007/s10008-008-0643-y]
PublicationObecność korozji wżerowej może być wykryta na podstawie występowania charakterystycznych przebiegów prądu płynącego między dwiema elektrodami, których wyprowadzenia są zwarte. Autorzy proponują nową metodę, która zachowuje informacje o stałej czasowej tych charakterystycznych dla procesów wżerowania przebiegów. Metoda została zastosowana do analizy szumów występujących podczas korozji stali 0H18N9 pod wpływem 1M roztworu FeCl3...
-
Bacterial strains colonizing the sensor electrodes of a continuous glucose monitoring system in children with diabetes
Publication -
Corporate social responsibility in reference to environmental statements within EMAS system in small and medium enterprises
PublicationAccording to the corporate social responsibility concept, organisations should apply any mechanisms available supporting their business actions contributing i.e. to the improvement of natural environment. Among them is EMAS eco-management and audit scheme. The prove of its implementation is environmental statement and entering the organisation into a national EMAS register. The aim of the statement is informing the society and...
-
Harmonic analysis of the current of an electric system simulating the electrode process in conditions of linearly changing potential
PublicationAnalizowany był prąd elektrycznego modelu symulującego pierwszorzędową reakcję elektrodową zachodzącą w warunkach liniowo zmieniającego się potencjału z nałożonym sygnałem sinusoidalnym. Pokazano, że transformacja Fouriera nie odzwierciedla zmian amplitudy składowych komponentów w funkcji potencjału. Także matematycznie wykazano, że zastosowanie transformacji Gabora do analizy spektralnej pozwala uzyskać poprawną dekompozycję częstotliwościową....
-
The influence of the geographic positioning system error on the quality of ship magnetic signature reproduction based on measurements in sea conditions
PublicationIn previous studies, the authors performed the magnetic signature reconstruction of the marine ship Zodiak as part of the measurement campaign focused on recording magnetic data and the relative position of a ship during its passage over a magnetometer immersed on the testing ground. A high degree of representation of the magnetic signature was obtained. However, the recorded measurement data revealed new patterns of the multidipole model...
-
Electrochemistry from first-principles in the grand canonical ensemble
PublicationProgress in electrochemical technologies, such as automotive batteries, supercapacitors, and fuel cells, depends greatly on developing improved charged interfaces between electrodes and electrolytes. The rational development of such interfaces can benefit from the atomistic understanding of the materials involved by first-principles quantum mechanical simulations with Density Functional Theory (DFT). However, such simulations are...
-
Lower rim substituted tert-butylcalix[4]arenes. Part 10. New Pb(II)-selective electrodes based on tetrasubstituted calix[4]arenes amides
PublicationOpracowano elektrody selektywne na jony Pb(II) oparte na lipofilowych tetrapodstawionych amidowych pochodnych kaliks[4] arenu. Charakterystyki elektrod mają nachylenie nernstowskie w szerokim zakresie stężeń 10 (-1.3) do 10 (-7.2).