Filters
total: 4180
-
Catalog
displaying 1000 best results Help
Search results for: active power filter
-
Multiple-channel frequency-adaptive active vibration control using SONIC
PublicationSONIC (self-optimizing narrowband interference canceller) is an acronym of a new approach to rejection of sinusoidal disturbances acting at the output of a discretetime stable linear plant with unknown and possibly timevarying dynamics. The paper presents two frequency-adaptive extensions of the multivariate SONIC algorithm. The efficacy of the proposed solutions is tested using our laboratory-scale active vibration control plant.
-
Modelling of Nuclear Power Plant Steam Turbine
PublicationThe paper describes the approach to a Nuclear Power Plant steam turbine modelling which would enable on-line optimal process control (model based) and diagnosis over wide range of operating conditions caused by changing power demand. Presented model is static, multivariable and nonlinear. Such model enables analyzing the heat cogeneration aspects. Developed model is validated and verified by using archive data gained from researches...
-
Modelling of Nuclear Power Plant Steam Turbine
PublicationThe paper describes the approach to a Nuclear Power Plant steam turbine modelling which would enable on-line optimal process control (model based) and diagnosis over wide range of operating conditions caused by changing power demand. Presented model is static, multivariable and nonlinear. Such model enables analyzing the heat cogeneration aspects. Developed model is validated and verified by using archive data gained from researches...
-
Profitability criteria of partial cogeneration in nuclear power plant.
PublicationIn this paper, profitability criteria and calculation methodology of profitability conditions for partial cogeneration in nuclear power plant (NPP) was presented. Considered NPP supplies electricity to consumers through public power system, whereas heat is expected to be supplied to consumption regions via long-distance heat transport line. First proposed profitability criterion was total annual costs of electricity and heat delivered...
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublicationIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
-
Voltage control in a power system with renewable sources of energy
PublicationIntensive development of distributed generation in power systems, caused by the European Union energy policy, gives possibility for improving safety in power delivery as well as optimizing the costs of the systems functioning. In this context, distributed generation can be used for voltage control in power systems – it can be performed by the control of reactive power of each source of energy or a group of energy sources. This...
-
Evaluation of technical efficiency of heat and electric power generation
PublicationThis paper presents an evaluation of technical efficiency and time-dependent changes in productivity of Polish professional electric power and heat&electric power stations by using Data Envelopment Analysis non-parametric method. The research covered the enterprises whose total available electric power amounted to about 98% of that of all professional thermal electric power stations in this country. The analysis has concerned...
-
Data Integration from GPS and Inertial Navigation Systems for Pedestrians in Urban Area
PublicationThe GPS system is widely used in navigation and the GPS receiver can offer long-term stable absolute positioning information. The overall system performance depends largely on the signal environments. The position obtained from GPS is often degraded due to obstruction and multipath effect caused by buildings, city infrastructure and vegetation, whereas, the current performance achieved by inertial navigation systems (INS) is still...
-
Hierarchical predictive control of integrated wastewater treatment systems
PublicationThe paper proposes an approach to designing the control structure and algorithms for optimising control of integrated wastewater treatment plant-sewer systems (IWWTS) under a full range of disturbance inputs. The optimised control of IWWTS allows for significant cost savings, fulfilling the effluent discharge limits over a long period and maintaining the system in sustainable operation. Due to the specific features of a wastewater...
-
Soil and groundwater contamination as a result of sewage sludge land application
PublicationThe leaching of chemical compounds (N-NO3, N-NH4, Norg, P-PO4, Ptot) and trace elements (Cd, Cu, Cr, Ni, Zn, and Pb) from sewage sludge and their migration through the soil profile was the subject of the study. The column experiments were carried out under atmospheric conditions corresponding to naturally occurring storm events - sewage sludge amended soil was irrigated with high rates of water. The column filter media used in...
-
Maritime traffic situation awareness analysis via high-fidelity ship imaging trajectory
PublicationSituation awareness provides crucial yet instant information to maritime traffic participants, and significant attentions are paid to implement traffic situation awareness task via various maritime data source (e.g., automatic identification system, maritime surveillance video, radar, etc.). The study aims to analyze traffic situation with the support of ship imaging trajectory. First, we employ the dark channel prior model to...
-
The efficiency and technological reliability of biogenic compounds removal during long-term operation of a one-stage subsurface horizontal flow constructed wetland
PublicationThe paper presents the results of a study of the efficiency and technological reliability of total nitrogen and total phosphorus removal during long term operation of a one-stage constructed wetland system with subsurface horizontal wastewater flow. The flow rate of the wastewater treatment plant was 1.2m3/d during the research period. Physical and chemical analyses of raw wastewater and treated effluent were carried out in the...
-
Rapid Microwave Design Optimization in Frequency Domain Using Adaptive Response Scaling
PublicationIn this paper, a novel methodology for cost-efficient microwave design optimization in the frequency domain is proposed. Our technique, referred to as adaptive response scaling (ARS), has been developed for constructing a fast replacement model (surrogate) of the high-fidelity electromagnetic-simulated model of the microwave structure under design using its equivalent circuit (low-fidelity model). The basic principle of ARS is...
-
The Design of Cavity Resonators and Microwave Filters Applying Shape Deformation Techniques
PublicationThis article introduces shape deformation as a new approach to the computer-aided design (CAD) of high-frequency components. We show that geometry deformation opens up new design possibilities and offers additional degrees of freedom in the 3-D modeling of microwave structures. Such design flexibility is highly desirable if the full potential of additive manufacturing (AM) is to be exploited in the fabrication of RF and microwave...
-
Biomass Production and Removal of Nitrogen and Phosphorus from Processed Municipal Wastewater by Salix schwerinii: A Field Trial
PublicationIn many Baltic regions, short-rotation willow (Salix spp.) is used as a vegetation filter for wastewater treatment and recycling of valuable nutrients to upsurge bioeconomy development. In this context, a four-year field trial (2016–2019) was carried out near a wastewater treatment plant in eastern Finland (Outokumpu) to investigate the effect of the processed wastewater (WW) on biomass production as well as the nutrients uptake...
-
Grid-Forming Operation of Energy-Router Based on Model Predictive Control with Improved Dynamic Performance
PublicationThe focus of this study is on the grid-forming operation of the Energy Router (ER) based on Model Predictive Control (MPC). ER is regarded as a key component of microgrids. It is a converter that interfaces the microgrid (s) with the utility grid. The ER has a multiport structure and bidirectional energy flow control. The ER concept can be implemented in Nearly Zero-Energy Buildings (NZEB) to provide flexible energy control. A...
-
Optimizing the parameters of a small standalone hybrid power system
PublicationA hybrid power plant consists of renewable energy resources, an energy storage, a discharge load and an emergency power supply. Power plant parameters are tailored to meet the requirements of continuity of supply, cost minimization, return on investment period and system capacity utilization. The papaer presents the methodology for selecting power plant parameters with a larger number of decision criteria. The task is solved...
-
Power Electronics Building Blocks for implementing Smart MV/LV Distribution Transformers for Smart Grid
PublicationWith an observed increase in the involvement of active consumers in activities aimed at improving energy efficiency and increasing interest in producing energy from renewable sources, there is a need for the development of new technologies enabling the distribution network operators to offer new services and functionalities. Smart MV/LV distribution transformers are characterized by a compact three-stage design, including an...
-
The Large Customer Reactive Power Control Possibilities
Publicationn this paper the authors wish to draw attention to the rationale for, and the possibility of, the use of local reactive power sources by the Transmission Node Master Controller (TNMC). Large Customers (LC) are one of the possible reactive power sources. The paper presents the issues related to the need for coordination between the control systems installed in the LC network, and coordination between control systems of the LC as...
-
Conjugated control of triple active bridge converter with common HFT
PublicationPaper presents synthetic analyses of single input, dual output DC/AC/DC converter with common high frequency transformer. Rise the problem of cross-coupling power flows between secondary terminals, under asymmetrical control operating condition. It also proposes a new approach to converter control, based on conjugated phase shift modulation and defines its limitations. Finally, the developed control technique was verified by simulation...
-
Human factors in nuclear power engineering in Polish conditions
PublicationThe paper “Human factors in nuclear power engineering in polish conditions” focuses on analysis of dynamics of preparing polish society to build first nuclear power plant in XXI century in Poland. Authors compare experience from constructing nuclear power plant Sizewell B (Great Britain) and Sizewell C, which is in preparation phase with polish nuclear power program. Paper includes aspects e.g. of creating nuclear safety culture...
-
Human Factors in Nuclear Power Engineering in Polish Conditions
PublicationThe paper “Human factors in nuclear power engineering in polish conditions” focuses on analysis of dynamics of preparing polish society to build fi rst nuclear power plant in XXI century in Poland. Authors compare experience from constructing nuclear power plant Sizewell B (Great Britain) and Sizewell C, which is in preparation phase with polish nuclear power program. Paper includes aspects e.g. of creating nuclear safety culture and...
-
The Influence of LED Lighting Sources on the Nature of Power Factor
PublicationThis article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...
-
Steam turbines governors in power system restoration process
PublicationThe paper discusses problems related to electric power system restoration process. The turbine controller operating mode influence in small subsystem is analyzed. There are considered abilities, advantages and drawbacks of the controller's two operating modes: power control and speed (frequen-cy) control, to rebuild electric power system from a single generating unit to a few parallel running generators.
-
Journal of Power Technologies
Journals -
Blackout initial disturbances in electric Power System searching
PublicationThe paper contains short survey of the blackouts that took place in the last few years. The sources and initial disturbances are discussed. The typical scenario of the disturbance, leading to blackout in the electrical power system are presented.Next, models of a power system eligible to considered topic are discussed. Finally the algorithm of the blackout initial disturbances in power system searching is presented.The consideration...
-
APPLICATION OF REDUNDANCY IN SHIP POWER PLANTS OF OFFSHORE VESSEL
PublicationPower and propulsion systems of offshore units must be of a very high level of reliability. The loss of ability to perform functions of their components causes generally to very high economic losses, which may be increased by unused the weather window resulting to postponing the planned offshore operations. To ensure carrying out so expensive offshore operations in the most reliable way, various types of redundancies are built-in...
-
Power Converter Solutions for Industrial PV Applications—A Review
Publication: As the use of photovoltaics becomes more widespread, new technologies for more efficient energy generation, transmission, and distribution based on power electronics converters are being developed. The most common applications are grid-on, energy storage, hybrid, and high voltage gain applications. These applications impose several additional requirements in the design of power converters associated with the solar battery’s maximum...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
REDUNDANCY AS A WAY INCREASING RELIABILITY OF SHIP POWER PLANTS
PublicationOne of key ways of assuring a high level of reliability of a ship power plant is to design redundancy of its structural elements, for example redundancy of prime drivers, drivelines etc. This paper deals with issues related to the redundancy as a way increasing dependability of the ship power and propulsion systems. Especially, fundamental characteristics of dependability, major design strategies influencing the reliability, and...
-
Power enhancement of the Brayton cycle by steam utilization
PublicationThe paper presents thermodynamic analysis of the gas-steam unit of the 65 MWe combined heat and power station. Numerical analyses of the station was performed for the nominal operation conditions determining the Brayton and combined cycle. Furthermore, steam utilization for the gas turbine propulsion in the Cheng cycle was analysed. In the considered modernization, steam generated in the heat recovery steam generator unit is directed...
-
Electric motor drive with inverter output filter
PublicationPrzedstawiono zagadnienie sterowania i estymacji w układzie napędowym z silnikiem indukcyjnym i filtrem sinusoidalnym.Filtr użyty jest do wygładzenia prądu i napięcia silnika. Filtr wprowadza spadek napięcia i przesunięcie fazowe prądów i napięć uniemożliwiające stosowane bezczujnikowych metod sterowania wektorowego. Rozwiązaniem jest uwzględnienie filtru w sterowaniu i estymacji. Artykuł pokazuje takie rozwiązanie dla metody sterowania...
-
Bandpass Filter Design Using Multimode Resonator
Publication -
FPGA realization of fir filter in residue arithmetic
Publicationw pracy zaprezentowano realizację fpga przepływowego filtru fir o stałych współczynnikach w arytmetyce resztowej z użyciem 8 5-bitowych modułów o łącznym zakresie liczbowym 37.07 bita. zastosowano formębezpośrednią fir. mnożenia wykonywane są przy użyciu odczytu z pamięci. sumowania w każdym z kanałów są realizowane przy zastosowaniu wielopoziomowej struktury sumatora opartego o 4-operandowe sumatory csa. w stopniu końcowym wykonywane...
-
Tracking analysis of a generalized adaptive notch filter
PublicationUogólniony adaptacyjny filtr wycinający służy do identyfikacji obiektów zmieniających się w sposób pseudookresowy. W pracy przedstawiono analizę własności śledzących takiego filtru a także omówiono zasady jego strojenia.
-
Adaptive filter for reconstruction of stereo audio signals.
PublicationArtykuł poświęcony jest omówieniu metody rekonstrukcji zakłóconych impulsowo sygnałów stereofonicznych. W pracy zdefiniowano model sygnału stereofonicznego i przedstawiono zaprojektowany dla tego modelu filtr Kalmana. Przedstawiono modyfikacje filtru, w wyniku których algorytm dokonuje rekonstrukcji zakłóconego impulsowo sygnału w jednym kanale z wykorzystaniem dodatkowej informacji zawartej w niezakłóconych próbkach sygnału pochodzącego...
-
Nuclear power plant as a source of electrical energy and heat
PublicationIn this paper certain issues concerning usage of nuclear power plants as sources of not only electric power but also thermal energy will be discussed. For such a solution appeals most of all the need to limit harmful emissions of gases (including CO2) and ashes, which come from the process of burning fossil fuels, as well as the raising demand for network heat and chill. Additionally combined heat and power production brings measurable...
-
Active dynamic thermography in cardiosurgery
Publication.
-
Active dynamic thermography in mammography.
PublicationW artykule przedstawiono zaproponowany numeryczny model termiczny piersi z nowotworem umiejscowionym na różnych głębokościach. Przedstawione są wyniki symulacji modelu dla różnych warunków zewnętrznego pobudzenia termicznego powierzchni piersi. Pokazano również wyniki przykładowego badania termograficznego piersi z nowotworem.
-
Active shape models in practice
PublicationAutorzy wykonali uniwersalny system lokalizacji obiektów zawierający implementację aktywnych modeli kształtu, a przeprowadzone z użyciem tego systemu eksperymenty wykazały powżne wady badanej metody. W pracy przedstawiono zaobserwowane w praktyce problemy związane ze stosowaniem metody aktywnych modeli kształtu (ASM).
-
Active Dynamic Thermography imaging of wound healing processes in cardio surgery
PublicationThe surgery is a branch of medicine, that is integrally connected to wounds. Despite using sterile tools and compliance with aseptic rolls, some of the surgery wounds become infected. In clinical practice there is a lack of cheap, objective methods and tools for quantitative definition and estimation of the surgery wound healing progress. This paper presents preliminary results of Active Dynamic Thermography (ADT) parametric imaging...
-
Optimal linear control theory in power system application
PublicationPrzedstawiono syntezę stabilizatora systemowego przy wykorzystaniu metodyki Hinf. Zaprojektowany regulator umożliwia uzyskanie lepszych rezultatów w porównaniu z regulatorem odniesienia w szerokim zakresie zmian punktu pracy.
-
Selected anionic and cationic surface active agents: case study on the Kłodnica sediments
PublicationSurface active agents (surfactants) are a group of chemical compounds, which are used as ingredients of detergents, cleaning products, cosmetics and functional products. After use, wastes containing surfactants or their degradation products are discharged to wastewater treatment plants or directly into surface waters. Due to their specific properties of SAAs, compounds are able to migrate between different environmental compartments...
-
Improvement of Oxygen Electrode Performance of Intermediate Temperature Solid Oxide Cells by Spray Pyrolysis Deposited Active Layers
PublicationIntermediate temperature solid oxide fuel cells oxygen electrodes are modified by active interfacial layers. Spray pyrolysis is used to produce thin (≈500 nm) layers of mixed ionic and electronic conductors: Sm0.5Sr0.5CoO3−δ (SSC), La0.6Sr0.4CoO3−δ (LSC), La0.6Sr0.4Co0.2Fe0.8O3−δ (LSCF), and Pr6O11 (PrOx) on the electrode–electrolyte interface. The influence of the annealing temperature on the electrode polarization (area specific...
-
Dynamic model of nuclear power plant turbine
PublicationThe paper presents the dynamic multivariable model of Nuclear Power Plant steam turbine. Nature of the processes occurring in a steam turbine causes a task of modeling it very difficult, especially when this model is intended to be used for on-line optimal process control (model based) over wide range of operating conditions caused by changing power demand. Particular property of developed model is that it enables calculations...
-
Microbe Power and Diversity: in Health and Society
e-Learning Courses -
Performance of Passive and Active Balancing Systems of Lithium Batteries in Onerous Mine Environment
PublicationTo use lithium-iron-phosphate battery packs in the supply systems of any electric mining equipment and/or machines, the required conditions of work safety must be met. This applies in particular to coal mines endangered by fire and/or explosion. To meet the spark-safety conditions, the cells (together with the battery management system—BMS) must be isolated from the influence of the environment, and therefore placed in special...
-
Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation
PublicationIn this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...
-
Active Dynamic Infrared Thermal Imaging in Burn Depth Evaluation
PublicationThe aim of this study was to find the relationship between active dynamic thermography (ADT) with cold excitation and burn depth. This new modality of evaluation of burns seems to be an attractive proposal for quantitative classification, allowing proper choice of burn wound treatment: conservative or surgical, especially compared with static thermography. The work was an in vivo experiment on domestic pigs, and a small number...
-
Voiceless Stop Consonant Modelling and Synthesis Framework Based on MISO Dynamic System
PublicationA voiceless stop consonant phoneme modelling and synthesis framework based on a phoneme modelling in low-frequency range and high-frequency range separately is proposed. The phoneme signal is decomposed into the sums of simpler basic components and described as the output of a linear multiple-input and single-output (MISO) system. The impulse response of each channel is a third order quasi-polynomial. Using this framework, the...