Search results for: measurement and evaluation
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublicationThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Application of the short time Fourier transformation to the continuous frequency method of measurement of electrode impedance
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest liniową funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego. Dokładność otrzymywanych wartości impedancji uwarunkowana jest wielkością okna i zastosowanej funkcji analizującej.
-
The critical rotational speed of circular saw: simple measurement method and its practical implementations.
PublicationProducenci pił tarczowych są zobligowani do podawania ich dopuszczalnych prędkości obrotowych. Jednakże, umieszczane przez nich prędkości na piłach są często bliskie prędkościom krytycznym lub je przewyższają. Przecinanie takimi narzędziami może być więc niebezpieczne dla obsługującego. Praca przedstawia prostą metodologię wyznaczania prędkości obrotowych krytycznych pił tarczowych. Badania były prowadzone z wykorzystaniem technik...
-
Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing
PublicationWe discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance gas sensing by considering its intensity and the slope of power spectral density. The issues of low-frequency noise measurements in resistive gas sensors, specifically in two-dimensional...
-
The Influence of Camera and Optical System Parameters on the Uncertainty of Object Location Measurement in Vision Systems
PublicationThe article presents the influence of the camera and its optical system on the uncertainty of object position measurement in vision systems. The aim of the article is to present the methodology for estimating the combined standard uncertainty of measuring the object position with a vision camera treated as a measuring device. The identification of factors affecting the location measurement uncertainty and the determination of their...
-
Analysis of Transformation Methods of Hydroacoustic and Optoelectronic Data Based on the Tombolo Measurement Campaign in Sopot
PublicationMeasurements in the coastal zone are carried out using various methods, including Global Navigation Satellite Systems (GNSS), hydroacoustic and optoelectronic methods. Therefore, it is necessary to develop coordinate transformation models that will enable the conversion of data from the land and marine parts to one coordinate system. The article presents selected issues related to the integration of geodetic and hydrographic data....
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
MEASUREMENT OF TEMPERATURE-DEPENDENT VISCOSITY AND THERMAL CONDUCTIVITY OF ALUMINA AND TITANIA THERMAL OIL NANOFLUIDS
PublicationIn this study results of simultaneous measurements of dynamic viscosity, thermal conductivity, electrical conductivity and pH of two nanofluids, i.e. thermal oil/Al2O3 and thermal oil/TiO2 are presented. Thermal oil is selected as a base liquid because of possible application in ORC systems as an intermediate heating agent. Nanoparticles were tested at the concentration of 0.1%, 1% and 5% by weight within temperature range from...
-
STUDY OF ARRAY OF MEMS INERTIAL MEASUREMENT UNITS UNDER QUASI-STATIONARY AND DYNAMIC CONDITIONS
PublicationA measurement system includes all components in a chain of hardware and software that leads from a measured variable to processed data. In that context, the type and quality of the sensors or measuring devices are critical to any measurement system. MEMS/IMU sensors lag behind leading technologies in this respect, but the MEMS/IMU performance rapidly changes while is relatively inexpensive. For this reason, the paper proposes...
-
Determination of the uncertainty of mass flow measurement using the orifice for different values of the Reynolds number
PublicationStandard orifice flowmeters are widely used in the chemical and energy industry. Therefore, it is essential to know how accurate the measurements made with these instruments are. The paper presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. The authors will present the influence of ranges of the Reynolds number on the estimated uncertainty, obtained on the basis of simulation and laboratory...
-
A Measurement System for Quasi-Spectral Determination of Absorption and Scattering Parameters of Veterinary Tissue Phantoms
PublicationThis paper describes the construction of a system for the quasi-spectral determination of absorption and scattering parameters of animal tissue phantoms. Several tissue phantoms, including one reference and two modified for examination, were prepared from polydimethylsiloxane (PDMS). The phantoms were measured using a system based on an integrating sphere and the light sources of wavelengths commonly used for the treatment of various...
-
3D Sound Intensity Measurement Around Organ Pipes Using Acoustic Vector Sensors
PublicationThe aim of the presented paper was to obtain and visualize sound intensity distribution of radiated acoustic energy around the organ pipes. The experimental setup consisted of the multichannel acoustic vector sensor and the specialized Cartesian robot. Measurements were performed in free field with spatial resolution of 0.1 [m]. Two organ pipes, i.e. wooden and metal were measured during the ex-periment. The organ pipes were activated...
-
Reduction of measurement data before Digital Terrain Model generation vs. DTM generalisation
PublicationModern data acquisition technologies provide large datasets that are not always necessary in its entirety to properly accomplish the goal of the study. In addition, such datasets are often cumbersome for rational processing, and their processing is time and labour consuming. Therefore, methods that enable to reduce the size of the measurement dataset, such as the generalization of the Digital Terrain Model (DTM) or the reduction...
-
Radioisotope measurement of selected parameters of liquid-gas flow using single detector system
PublicationTo determine the parameters of two-phase flows using radioisotopes, usually two detectors are used. Knowing the distance between them, the velocity of the dispersed phase is calculated based on time delay estimation. Such a measurement system requires the use of two gamma-ray sealed sources. But in some situations it is also possible to determine velocity of dispersed phase using only one scintillation probe and one gamma-ray source....
-
Using On-line Measurement by Electronic Nose and Computer Simulations for Real-time Control at WWTP
PublicationContinuous investigation of wastewater quality can be carried out by a device called an e-nose. One important feature of the proposed real-time control system for WWTP is that using on-line measurements by e-nose together (Figure 1) with technological sets picked on this basis by means of computer models, it is possible to change treatment process parameters, depending on the current quality of wastewater. It can be used for the...
-
The concept of estimation of elevator shaft control measurement results in the local 3D coordinate system.
PublicationGeodetic control measurements play an important part because they provide information about the current state of repair of the construction, which has a direct impact on the safety assessment of its exploitation. Authors in this paper have focused on control measurements of the elevator shaft. The article discusses the problem of determining the deviation of elevator shaft walls from the vertical plane in the local 3D coordinate...
-
Ellipse-fitting algorithm implementation in the impedance measurement system based on DAQ card with FPGA
PublicationThe paper presents an implementation of the ellipse-fitting algorithm in the impedance measurement system based on DAQ card equipped with FPGA chip. The method implementation was tested by simulation means as well as experimentally in the designed and presented measurement system. Finally, the limit values of sampling parameters which assures satisfying accuracy were given.
-
Impedance Measurement and Selection of Electrochemical Equivalent Circuit of a Working PEM Fuel Cell Cathode
PublicationThe dynamic impedance analysis of direct methanolfuel cell (DMFC) cathode supplied with pure oxygen is pre-sented. Presented results were obtained during dynamic chang-es of the current density in working fuel cell. Investigation ofthe occurring processes at cathode was carried with dynamicelectrochemical impedance spectroscopy (DEIS). A discussionwas conducted based on the determined correlation parameterχ2. It was shown that...
-
Application of particle image velocimetry (PIV) for deformation measurement during granular silo flow.
PublicationW artykule przedstawiono wyniki pomiarów tensora odkształceń w materiałach granulowanych podczas przepływu silosowego Pomiary wykonano przy zastosowaniu techniki optoelektronicznej PIV dla silosów z wkładkami i bez wkładek. Wyniki porównano ze zdjęciami rentgenowskimi.
-
Preparation to ball on disk test Initial contact stress evaluation
Open Research DataEvaluation of initial contact stress in tests on wear of Al6061 alloy in ball on disk tribological testing. Research on the reinforcing effect of aluminium alloy injection reinforcement with TiN and WC powders in laser remelted surface layer.
-
Engineering method of tire rolling resistance evaluation
PublicationTire rolling resistance is one of the most difficult tire parameters to measure. The reason is that for modern tires the force of rolling resistance corresponds to 0.5–1% of tire load, thus measurements of very small forces must be performed in a heavily loaded system. This constitutes great problems, especially in road conditions. Laboratory measurements are easier to perform, as the environment may be better controlled, but roadwheel...
-
Wavelet Transform Analysis of Temperature Modulated Gas Sensor Response
PublicationThe aim of the study was to evaluate whether it is possible to extract the information about the gas concentration despite the influence of humidity. Commercial semiconductor sensor response was examined under the application of a periodic temperature change. The data was collected using measurement protocol for different concentrations of ammonia at specified levels of relative humidity. In this work we focused on the evaluation...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublicationThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Evaluation of antimicrobial properties of thermomelt adhesives modified with zinc compounds
Open Research DataThe dataset contains the results of microbiological tests of thermomelt adhesives modified with zinc compounds, whose activity was assessed for their ability to reduce the number of Escherichia coli and Staphylococcus aureus strain, representing the Gram (-) and Gram (+) bacteria, respectively. The evaluation of antimicrobial properties of samples were...
-
Instantaneous Impedance Analysis of Non-Stationary Corrosion Process: a Case Study of Carbon Steel in 1M HCl
PublicationThe paper concerns the problem of evaluation of stationarity of carbon steel corrosion in 1M HCl. Comparison of corrosion rate with addition of corrosion inhibitor to the reference measurement is the most often used way of evaluating inhibitor efficiency. Such an approach is valid only if corrosion rate is a stationary process. Two complementary techniques were used simultaneously: volumetric analysis of evolved hydrogen and instantaneous...
-
Tribological test for evaluation of CF30 Black PEEK
Open Research DataSample numner BL03 and BL04 made of PEEK CF30 (black color) tribologicaly tested with sliding speed up to 1,8 m/s and up to 14 MPa of nominal load under water lubrication.
-
Measures for Evaluation of Structure and Semantics of Ontologies
PublicationArtykuł przedstawia zagadnienie miar jakości ontologii ze szczególnym uwzględnieniem ich podziału na syntaktyczne (strukturalne) i semantyczne. Na tym tle przedstawione jest nowe podejście do pomiaru właściwości semantycznych ontologii bazujące na kartografii wiedzy.
-
An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples
Publication -
Research Protocol of the Polish Adaptation and Validation of HOPE Scale: Qualitative Measurement of Patients' Spiritual Needs
Publication -
Automatic resource identification for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard
Publication -
THE APPLICATION OF BALANCED SCORECARD METHOD FOR THE SELECTION OF FACTORS USED IN THE EFFICIENCY MEASUREMENT OF PUBLIC HOSPITALS IN POLAND
Publication -
Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine
Publication -
Urinary Measurement of 8-OxodG, 8-OxoGua, and 5HMUra: A Noninvasive Assessment of Oxidative Damage to DNA
Publication -
Measurement of idlers rotation speed in belt conveyors based on image data analysis for diagnostic purposes
Publication -
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publication -
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
A measurement system for nonlinear surface spectroscopy with an atomic force microscope during corrosion process monitoring
PublicationIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is espe-cially useful for heterogeneous...
-
Myrosinase activity in different plant samples; optimisation of measurement conditions for spectrophotometric and pH-stat methods
PublicationMyrosinase found in Brassicaceae plants, is the enzyme responsible for hydrolysis of glucosinolates. As a result a variety of biologically active metabolites are liberated, whose importance in crop protection and especially in cancer chemoprevention is rapidly gaining recognition. The growing practical application of glucosinolate degradation products requires that sensitive and reliable methods of myrosinase activity determination...
-
Old-timer Vehicle - Braking Efficiency Measurement at Vehicle Inspection Stations and Roadworthiness Validity Certificate.
PublicationObtaining the Roadworthiness Validity Certificate for an old-timer vehicle involves an appropriate test performance, namely, "Old-timer Vehicle Technical Specification Compliance Test". It seems obvious that this kind of test should include a considerable checklist, however, the current legal regulations connected with this test are not specific enough. One of the certificates issued on this test results is "Old-timer Vehicle Technical...
-
Optoelectronic properties of the metal-tetracene interface investigated by current noise measurement under monochromatic irradiation.
PublicationZaprezentowano badania prądów ograniczonych elektrodowo w warstwach tetracenu. Szczególną uwagę zwrócono na zależność szumów elektrycznych od przyłożonego napięcia i padającego światła.
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublicationDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Investigations of the Methods of Time Delay Measurement of Stochastic Signals Using Cross-correlation with the Hilbert Transform
PublicationThe article presents the results of simulation studies of four methods of estimating time delay for random signals using cross-correlation with the Hilbert Transform. Selected models of mutually delayed stochastic signals were used in the simulations, corresponding to the signals obtained from scintillation detectors in radioisotope measurements of liquid-gas two-phase flow. Standard deviations of the values of the individual functions...
-
Downlink Capacity-Coverage Trade-off Estimation Based on Measurement of WCDMA/FDD Interface Load
PublicationThe method of capacity-coverage trade-off determination by using of universal load characteristics and normalized coverage curves for the WCDMA/FDD radio interface has been presented. The practical applications of discussed method for UMTS radio network planning process and network exploitation has been mentioned.
-
A Computational Analysis of the Aerodynamic and Aeromechanical Behavior of a Thermo-Well for Steam Temperature Measurement in a Steam Turbine
PublicationThe goal of the paper is twofold: firstly, it presents computational fluid dynamics analysis for finding maximum unsteady flow forces (and their frequencies) acting on a thermo-well for measuring steam temperature in a steam turbine control stage and secondly, it presents computational solid dynamics analysis of possibility of entry into resonance of the thermowell structure. There have been analyzed two cases of flow with changing...
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublicationThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublicationAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Measurement of the Temporal and Spatial Temperature Distribution on the Surface of PVCP Tissue Phantom Illuminated by Laser Dataset
PublicationThe dataset entitled Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser was obtained with a laboratory set-up for characterisation of the thermal properties of optical tissue phantoms during laser irradiation. The dataset contains a single image file representing the spatial temperature distribution on the surface of a PVCP tissue phantom. This thermal image...
-
Fatigue life improvement using low transformation temperature weld material with measurement of residual stress
PublicationWelding processes often produce high levels of tensile residual stress. Low transformation temperature (LTT) welding wires utilise phase transformation strains to overcome the thermal contraction of a cooling weld. In this paper, the residual stress within each weld was quantified using the milling/strain gauge method, being the strain change measured as the weldment was milled away. The fatigue tests were conducted under uniaxial...
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublicationThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...