Filters
total: 2386
filtered: 1706
-
Catalog
- Publications 1706 available results
- Journals 30 available results
- Conferences 11 available results
- Publishing Houses 1 available results
- People 122 available results
- Inventions 4 available results
- Projects 24 available results
- Research Teams 3 available results
- Research Equipment 2 available results
- e-Learning Courses 37 available results
- Events 1 available results
- Open Research Data 445 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: sensory elektrochemiczne
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublicationThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublicationLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
Investigation of sensing mechanism of Nasicon electrocatalytic sensors in nitrogen dioxide and ammonia
PublicationIn this paper a sensing mechanism of Nasicon electrocatalytic sensor in nitrogen dioxide and ammonia is investigated. Both gases are environmentally hazardous and contain nitrogen atom in the molecule. However, it seems that their sensing mechanism in electrocatalytic sensor could be totally different. Namely, the maximum sensitivity for each gas was obtained at different temperatures. Also, different auxiliary layers are formed...
-
Pulsed UV-irradiated Graphene Sensors for Ethanol Detection at Room Temperature
PublicationA graphene-based gas sensor fabricated in a FET (GFET) configuration and its sensitivity towards ethanol and methane is reported. Detection of ethanol at the level of 100 ppm was observed under pulsed UV irradiation and after cleaning by UV light in the N2 ambient. Reduction of the frequency of UV irradiation pulses resulted in increased changes in sensor resistance in the presence of ethanol. Improved sensing behavior was ascribed...
-
Inverse Modeling and Optimization of CSRR-based Microwave Sensors for Industrial Applications
PublicationDesign optimization of multivariable resonators is a challenging topic in the area of microwave sensors for industrial applications. This paper proposes a novel methodology for rapid re-design and parameter tuning of complementary split-ring resonators (CSRRs). Our approach involves inverse surrogate models established using pre-optimized resonator data as well as analytical correction techniques to enable rapid adjustment of geometry...
-
Portable Electronic Nose Based on Electrochemical Sensors for Food Quality Assessment
PublicationThe steady increase in global consumption puts a strain on agriculture and might lead to a decrease in food quality. Currently used techniques of food analysis are often labour-intensive and time-consuming and require extensive sample preparation. For that reason, there is a demand for novel methods that could be used for rapid food quality assessment. A technique based on the use of an array of chemical sensors for holistic analysis...
-
Gas selectivity enhancement by sampling-and-hold method in resistive gas sensors
PublicationCommercial resistive gas sensors exhibit various sensitivity to numerous gases when working at different elevated temperatures. That effect is due to a change in velocity of adsorption and desorption processes which can be modulated by temperature. Thus, to reach better selectivity of gas detection, we propose to apply a known method (called the sampling-and-hold method) of cooling down the gas sensor in the presence of the investigated...
-
New approaches for improving selectivity and sensitivity of resistive gas sensors: a review
PublicationPurpose – This paper aims to present the methods of improving selectivity and sensitivity of resistance gas sensors. Design/methodology/approach – This paper compares various methods of improving gas sensing by temperature modulation, UV irradiation or fluctuation-enhanced sensing. The authors analyze low-frequency resistance fluctuations in commercial Taguchi gas sensors and the recently developed tungsten trioxide (WO3) gas-sensing...
-
SAMPLE-AND-HOLDING METHOD FOR GAS SENSING APPLIED FOR RESISTANCE GAS SENSORS
PublicationThe DC resistance of a Taguchi gas sensor is influenced by the ambient gas. To improve the selectivity and sensitivity of a sensor the fluctuation enhanced sensing (FES) was used. The paper proposes a novel methodology of utilizing FES technique that sample composition of an ambient atmosphere and hold it for further processing (sample-and-holding technique). The method uses the heated gas sensor to sample an ambient atmosphere...
-
New approaches for improving selectivity and sensitivity of resistive gas sensors: A review
PublicationResistive gas sensors are very popular and reliable but suffer from low selectivity and sensitivity. Various methods have been suggested to improve both features without increasing the number of sensors in gas detection systems. Fluctuation enhanced gas sensing was proposed to improve gas detection efficiency by analyzing low-frequency resistance fluctuations, and noise parameters can be more informative than the single DC resistance...
-
Interferometric optical fiber sensors with active stabilization of the operating point using a tunable semiconductor laser. Optical Fibres and Their Applications VIII.
PublicationW pracy przedstawiono wyniki badań światłowodowych interferometrycznych sensorów siły wykonanych w konfiguracji interferometru Michelsona i wykorzystujących aktywną stabilizację punktu pracy przy pomocy zmiany długości fali źródła. Porównano dwie klasy omawianych sensorów a następnie zrealizowano sensor. W konstrukcji sensora zastosowano modulator z pośrednim pomiarem siły. Mierzona siła jest zamieniana na ciśnienie hydrostatyczne,...
-
Highly Reliable Passive RFID-Based Inductor–Capacitor Sensory System Strengthened by Solvatochromism for Fast and Wide-Range Lactate Detection
PublicationA passive radio frequency-identification-based inductor-capacitor (LC) lactate sensory system with a specific dye-containing interdigitated capacitor (IDC) in which the sensing signal is amplified by the solvatochromic effect is proposed. When a lactate solution contacts the IDC of the LC lactate sensor, the capacitance of the IDC changes, changing the resonance frequency of the sensor. This changes the oscillation frequency of...
-
Electrochemical study of lithium insertion into carbon-rich polymer-derived silicon carbonitride ceramics
PublicationW pracy przedstawiono materiał ceramiczny, bogaty w węgiel krzemo azotek węgla (SiCN), otrzymany na drodze pirolizy w zakresie temperatur od 1100 do 1700°C. Badania elektrochemiczne insercji litu wykazały, że materiał elektrodowy na bazie SiCN może być obiecujący jako anoda w bateriach litowych. Próbka otrzymana w 1300°C cechuje się pojemnością 392 mAh/g i jest stabilna aktywna elektrochemicznie w trakcie interkalacji i deinterkalacji...
-
Oscylacje różnicy potencjału elektrochemicznego między fazami oscylatora z membraną ciekłą zawierającego bromek heksadecylotrimetyloamoniowy.Oscyllations of electrochemical potential difference between phases of liquid membrane oscillator containing heksadecyltrimethylammonium bromide.
PublicationBadano zmiany różnicy potencjału elektrochemicznego między fazami wodnymi oscylatora z membraną ciekłą zawierającego bromek heksadecylotrimetyloamoniowy przy zastosowaniu mikroelektrod Ag/AgCl/Cl. Stwierdzono, iż główny udział do różnicy potencjału elektrochemicznego między fazami wodnymi, wnoszą różnice potencjału między odpowiednią faza wodną i membraną ciekłą. Wartości obliczone z poszczególnych składowych są w bardzo dobrej...
-
<title>White-light interferometric temperature sensor for biomedical diagnostic</title>
Publication -
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublicationIn this work amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode will be presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been investigated.
-
Functionalized azobenzocrown ethers as sensor materials—The synthesis and ion binding properties
PublicationNew 13- and 16-membered azobenzocrown ethers with aromatic amino, amide, ether–ester or ether–amide residue in para position to an azo moiety were obtained. Acid–base properties and ion binding ability of the colored compounds were studied by spectroscopic methods: UV–vis, fluorimetry and 1H NMR spectroscopy. Selected azobenzocrowns were tested as ionophores in ion-selective membrane electrodes (ISEs) – classic and miniature all...
-
Investigation of solid polymer electrolyte gas sensor with different electrochemical techniques
PublicationIn this work solid polymer electrolyte (SPE) amperometric sulphur dioxide sensor is investigated. Nafion was used as a membrane electrode and 1M sulphuric acid as an internal electrolyte. Sensor response to sulphur dioxide was measured. Besides traditional constant voltage amperometry also different electrochemical techniques were used. Results obtained by these methods are compared.
-
Construction and investigation of SO2 amperometric sensor with a solid polymer electrolyte membrane
Publicationn this paper a sensor for detection of the sulphur dioxide based on three electrode cell configuration with a liquid electrolyte, a mercury sulphate reference electrode and a solid polymer electrolyte working electrode is presented. Working elec- trode was obtained by using Takenaka-Torikai chemical deposi- tion method by precipitation of Au particles into the pores of the Nafion membrane. Sensors characteristics measurements were...
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublicationIn this work investigation of an amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode properties is presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been studied.
-
Transmission Protocol Simulation Framework For The Resource-Constrained Wireless Sensor Network
PublicationIn this paper a prototype framework for simulation of wireless sensor network and its protocols are presented. The framework simulates operation of a sensor network with data transmission, which enables simultaneous development of the sensor network software, its hardware and the protocols for wireless data transmission. An advantage of using the framework is converging simulation with the real software. Instead of creating...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublicationThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Enhancing Performance of Switched Parasitic Antenna for Localization in Wireless Sensor Networks
PublicationThis paper presents an Electronically Steerable Parasitic Array Radiator (ESPAR) antenna with enhanced performance of estimating the incoming signal direction. Designed antenna is dedicated for 2.4 GHz ISM applications with emphasis on Wireless Sensor Networks (WSN). The limitations of the existing design approach are illustrated, as well as perspectives and challenges of the proposed solution in relation to the localization in...
-
<title>Colorimetric sensor based on two optical fiber couplers</title>
Publication -
<title>Temperature sensor based on double-core optical fiber</title>
Publication -
Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation
PublicationA procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...
-
Road surface roughness estimation employing integrated position and acceleration sensor
PublicationAssessment of a surface quality being an essential task for the authorities supervising the roads provides the subject of the paper. Information about riding quality of a pavement, important for drivers, both in terms of their comfort and safety is collected during experiments employing mobile sensors. The paper describes the use of a miniature position and acceleration sensor for evaluation of the roughness of the road surface....
-
Stability of an optical displacement sensor using a two-beam polarization interferometer
PublicationW artykule przedstawiono wyniki pomiarów stabilności wybranej konfiguracji dwuwiązkowego interferometru polaryzacyjnego. Przedyskutowano źródła występującej niestabilności.
-
Distance magnetic nanoparticle detection using a magnetoelectric sensor for clinical interventions
Publication -
An Implementation of a Compact Smart Resistive Sensor Based on a Microcontroller with an Internal ADC
PublicationIn the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and the resistive sensor connected in parallel with an interference suppression capacitor. The measurement...
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublicationIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
-
Diagnostics of the Peripheral Artery Disease with use of Glucose Sensor - A Proof of Concept
PublicationIt is estimated that 13 % of population over 50 years old suffer from symptomatic or asymptomatic peripheral artery disease (PAD). Ankle-brachial index (ABI) is viewed as a useful parameter in diagnostics of peripheral arterial disease, however screening tests with usage of this method are not advised. Hypoxia causes increase in lactate values and...
-
Investigation of Taste Substances by five Channel Lipid-Polymer Membrane Sensor.
PublicationBadano substancje o różnych stężeniach należące do czterech klas smaku za pomocą pięcio-kanałowego sensora opartego o elektrody jonoselektywne z różnymi membranami polimerowo-lipidowymi. Stwierdzono, że sensor jest czuły na zmiany stężeń chlorowodorku chininy, kawsu cytrynowego i chlorku sodu, przeciwnie jak w przypadku sacharozy. Na podstawie tych wyników można przypuszczać, że sensor może być zastosowany do roztworów składających...
-
Properties of a lithium solid electrolyte gas sensor based on reaction kinetics
PublicationW artykule przedstawiono zasadę działania, budowę i właściwości czujnika gazu na bazie elektrolitu stałego z mobilnymi jonami litu. Czujnik został przygotowany w technologii grubowarstwowej. Przedstawiono wyniki badań czujnika w mieszaninach gazów toksycznych.
-
Properties of a polyethyleneimine-based sensor for measuring medium and high relative humidity
PublicationW artykule przedstawiono metodę przygotowania filmów polimerowych o zwiększonej odporności na działanie wody. Polietylenoimina została usieciowana w podwyższonej temperaturze. Określono optymalną kompozycję polimeru oraz temperaturę sieciowania. Czujniki rezystancyjne przygotowano metodą ''dip-coating''. Otrzymane czujniki charakteryzują się doskonałą trwałością w wysokich wilgotnościach. Elektryczne parametry czujników określono...
-
Diagnostics of the Peripheral Artery Disease with use of Glucose Sensor - A Proof of Concept
PublicationIt is estimated that 13% of population over 50 years old suffer from symptomatic or asymptomatic peripheral artery disease (PAD). Ankle-brachial index (ABI) is viewed as a useful parameter in diagnostics of peripheral arterial disease, however screening tests with usage of this method are not advised. Hypoxia causes increase in lactate values and decrease in blood glucose. We hypothesize that the deficit in blood supply to the...
-
Sounding Mechanism of a Flue Organ Pipe—A Multi-Sensor Measurement Approach
PublicationThis work presents an approach that integrates the results of measuring, analyzing, and modeling air flow phenomena driven by pressurized air in a flue organ pipe. The investigation concerns a Bourdon organ pipe. Measurements are performed in an anechoic chamber using the Cartesian robot equipped with a 3D acoustic vector sensor (AVS) that acquires both acoustic pressure and air particle velocity. Also, a high-speed camera is employed...
-
Development of beltless respiration and heartbeat sensor based on flexible piezoelectric film
PublicationThe main goal of this work is to report initial development on a respiration and heartbeat measurement sensor that can be used in continuous monitoring conditions at a minimal impact on the patient. General description of the sensor, consisting of a PVDF film and the bonding layer, is given. Open-circuit voltage generated by the sensor is estimated by analytical and numerical calculations. Analog and digital interface used to extract...
-
Electrochemically directed biofunctionalization of a lossy-mode resonance optical fiber sensor
PublicationIn this work, we present a direct electrochemical biofunctionalization of an indium-tin-oxide-coated lossy-mode resonance optical fiber sensor. The functionalization using a biotin derivative was performed by cyclic voltammetry in a 10 mM biotin hydrazide solution. All stages of the experiment were simultaneously verified with optical and electrochemical techniques. Performed measurements indicate the presence of a poly-biotin...
-
Sensor Position Estimation Method for IoT Using Mobile Reference Node
PublicationThe paper proposes an innovative method of locating objects for the Internet of Things (IoT). The proposed method allows the position of a fixed measuring sensor (MS) to be estimated using one mobile base station with a known position moving around the MS. The mathematical analysis of the method, and three algorithms — Newton’s (NA), gradient descent (GD) and genetic (GA) — for solving the system of non-linear positional equations...
-
A Highly Sensitive Planar Microwave Sensor for Detecting Direction and Angle of Rotation
PublicationThis article presents a technique based on a modified complementary split-ring resonator (CSRR) to detect angular displacement and direction of rotation with high resolution and sensitivity over a wide dynamic range. The proposed microwave planar sensor takes advantage of the asymmetry of the sensor geometry and measures the angle of rotation in terms of the change in the relative phase of the reflection coefficients. The sensor...
-
Interferometric Sensor of Wavelength Detuning Using a Liquid Crystalline Polymer Waveplate
PublicationOperation of a polarization interferometer for measurement of the wavelength changes of a tunable semiconductor laser was investigated. A lambda/8 waveplate made from liquid crystalline polymer is placed in one of interferometers’ arms in order to generate two output signals in quadrature. Wavelength was measured with resolution of 2 pm in the wavelength range 628–635 nm. Drift of the interferometer, measured in the period of 500...
-
Using differential pressure sensor to measure nitrous oxide level in a tank
PublicationA method for measuring the level of liquid nitrous oxide oxidizer in a hybrid rocket motor oxidizer tank is proposed. Presented approach is more accurate than the most commonly used method of this measurement, which employs weighting of the whole sounding rocket or an oxidizer tank. In our solution we use a differential pressure sensor to measure the change of pressure at the bottom of an oxidizer tank in comparison to the pressure...
-
Simple colorimetric copper(II) sensor – spectral characterization and possible applications
PublicationNew o-hydroxyazocompound L bearing pyrrole residue was obtained in the simple synthetic protocol. The structure of L was confirmed and analyzed by X-ray diffraction. It was found that new chemosensor can be successfully used as copper(II) selective spectrophotometric regent in solution and can be also applied for the preparation of sensing materials generating selective color signal upon interaction with copper(II). Selective colorimetric...
-
The analysis of stationary electrochemical noise.
PublicationSzum elektrochemiczny jest techniką cieszącą się rosnącym zainteresowaniem. Jedną z podstawowych charakterystyk przebiegów otrzymywanych za pomocą omawianej metody jest widmowa gęstość mocy. Prawidłowa estymacja powyższej wielkości wiąże się z koniecznością zachowania wymogu stacjonarności szumu elektrochemicznego. W niniejszej pracy autorzy proponują zastosowanie rozkładu Wignera-Villego do oceny stopnia niestacjonarności przebiegów...
-
Optoelektroniczny czujnik do oznaczania stężenia tlenu rozpuszczonego w roztworach wodnych
PublicationW artykule opisano koncepcję nowej konstrukcji czujnika tlenu rozpuszczonego w wodzie. Czujnik ten składa się z dwóch części : optoelekronicznej i elektrochemicznej. Pomiar tym czujnikiem sprowadza się do pomiaru zmiany natęzenia promieniowania monochromatycznego przechodzącego przez komorę wypełnioną roztworem zawierającym tlen rozpuszczony. Część elekrochemiczna czujnika umożliwa przeprowadzenia jego automatycznej kalibracji...
-
Fatty Acid Profile, Health Lipid Indices, and Sensory Properties of Meat from Pekin Ducks of Different Origins
Publication -
Embedded system using Bluetooth Low Energy sensors for smart farming applications
PublicationThe main goal of this Bachelor of Engineering project titled Embedded system using Bluetooth Low Energy sensors for smart farming applications is to create a prototype of a system consistent with Agriculture 4.0 concept using Bluetooth Low Energy (BLE) technology. Developed solution shall be easy in implementation and its main functionality shall be periodic gathering of data from environmental sensors...
-
Resistance noise in tio2-based thin film gas sensors underultraviolet irradiation
PublicationBadano możliwości wykorzystania fluktuacji rezystancji w cienkich warstwach TiO2 do wykrywania gazów. Pomiary przeprowadzono, gdy próbka była oświetlona promieniowaniem ultrafioletowym o długości 370nm, w obecności gazu H2S. Stwierdzono, że fluktuacje rezystancji są indukowane promieniowaniem ultrafioletowym i pozwalają na wykrycie obecności H2S w stężeniu do 1.5 ppm.