Filtry
wszystkich: 3808
-
Katalog
- Publikacje 3074 wyników po odfiltrowaniu
- Czasopisma 96 wyników po odfiltrowaniu
- Konferencje 13 wyników po odfiltrowaniu
- Osoby 80 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 53 wyników po odfiltrowaniu
- Wydarzenia 3 wyników po odfiltrowaniu
- Dane Badawcze 486 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: quality of supply voltage
-
Static Shunt PE Voltage-Quality Controllers
PublikacjaThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublikacjaThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Quality assessment of low voltage surge arresters
PublikacjaUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
Classification of high-voltage varistors into groups of differentiated quality
PublikacjaThe research was aimed on defining a factor of quality for high-voltage varistors using Non-Destructive Testing (NDT) techniques, which could be applied during the production testing. The newly proposed parameter Q determined on the basis of the lowest resonant frequency fr measured within the preselected frequency range was taken into account. The parameter Q was defined for ZnO structures after firing, without metallized contacts....
-
Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station
PublikacjaThis paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...
-
Analysis of inductive power transfer systems for variable air gap and voltage supply frequency
PublikacjaThe paper describes an IPT system, by which electrical energy may be transmitted through a large air gap between coils without electrical connection. It presents theoretical and simulation analysis of IPT, which allows for supplying a receiver in the conditions of slow, in relation to the dynamics of power supply, changes in dimension of the air gap. The influence of frequency characteristics of the system on the possible selection...
-
Random components influence on the values characterising periodic disturbances in low voltage supply lines.
PublikacjaAnalizowano wpływ składowych losowych na wielkości charakteryzujących zaburzenia okresowe w napięciu zasilania na przykładzie współczynnika zawartości harmonicznych (THD). Zaprezentowano sposób wyznaczania niepewności pomiaru współczynnika THD, uwzględniający występowanie korelacji pomiędzy składową podstawową i kolejnymi harmonicznymi napięcia sieci a także między poszczególnymi harmonicznymi. Przedstawiono analizę wyników z pomiarów...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublikacjaAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Quality assessment of high voltage varistors by third harmonic index
PublikacjaHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublikacjaResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
Method of Estimating Uncertainty as a Way to Evaluate Continuity Quality of Power Supply in Hospital Devices
Publikacja -
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublikacjaThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Piotr Grudowski dr hab. inż.
OsobyDr hab. inż. Piotr Grudowski, profesor w Politechnice Gdańskiej karierę naukową rozpoczynał na Wydziale Mechanicznym Technologicznym Politechniki Gdańskiej w zespole „Inżynierii Jakości i Metrologii”. Stopień doktora nauk technicznych w dyscyplinie budowa i eksploatacja maszyn uzyskał w roku 1993 na Wydziale Mechanicznym PG a stopień doktora habilitowanego nauk ekonomicznych, w dyscyplinie nauk o zarządzaniu, w 2008 roku na Wydziale...
-
Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries
PublikacjaThe paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...
-
Problems of varistor quality assessment during exploitation
PublikacjaVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublikacjaThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
Measurements of power supply system properties of "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Dane BadawczeTests of the power supply system of "SpeedLine magnetic" ultra-fast industrial robot for IML labeling were carried out to analyze the effect of the active power filter (APF) parameters on the power quality. at the target duty cycle. Tests were performed with the target duty cycle. Linear synchronous motors with permanent magnets were used to drive...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials during maneuvering.
-
СИЛОВОЙ ПРЕОБРАЗОВАТЕЛЬ С АКТИВНЫМ ПОДАВЛЕНИЕМ ВЫСШИХ ГАРМОНИК ДЛЯ СИСТЕМ ЭЛЕКТРОСНАБЖЕНИЯ ЛЕТАТЕЛЬНЫХ АППАРАТОВ (Power converter with active suppression of higher harmonics for aircraft power supply systems)
PublikacjaПредставлены два алгоритма активной фильтрации для силового преобразователя с активным подавлением высших гармоник. Первый алгоритм основан на дискретном преобразовании Фурье: посредством синтезированной системы управления инвертированные измеренные высшие гармоники напряжения поступают на вход инвертора. Второй метод управления основан на алгоритме с использованием принципов самообучения, что значительно снижает потребность в...
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
The harmonic distortion of voltage waveforms in the ship's electrical power system
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the ship's electrical power system's main switchboard in different states of ship exploitation. The attached dataset contains the results of a harmonic distortion analysis expressed by the total harmonic distortion (THD) coefficient of voltage waveforms recorded...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during maneuvering.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a layover at the port
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a layover at the port.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a layover at the port
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a layover at the port.
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a sea voyage.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during maneuvering
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during maneuvering.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.
-
Decentralized control of a different rated parallel UPS systems
PublikacjaThe paper presents the single phase uninterruptible power supply (UPS) system with galvanic separated DC-AC-DC-AC converters operating in parallel. The CAN physical layer based system of communication between converters has been developed and applied, which allow to utilize a decentralized master-slave control providing high availability factor of the whole UPS system. The control system of particular converters has been developed...
-
The Influence of a Photovoltaic Micro-Installation on the Low-Frequency Parameters of Electricity at PCC and Its Impact on the Thermal Characteristics of Selected Devices
PublikacjaThis manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking...
-
Multi-transformer primary-side regulated flyback converter for supplying isolated IGBT and MOSFET drivers
PublikacjaThis paper presents primary-side voltage regulated multi-transformer quasi-resonant flyback converter (MTFC) for supplying isolated power switch drivers. The proposed topology offers distinct advantages over frequently used flyback converter possessing one high frequency transformer with isolated multiple outputs. Particularly, when a large number of separate dc supply units is required, then MTFC enables improved regular distribution...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a bow thruster start-up
Dane BadawczeThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. In ships' electrical power systems, disturbances occurring in voltage waveforms on bus bars of the main switchboard are connected mainly with the processes...
-
Modern Arrangement for Reduction of Voltage Perturbations
PublikacjaThe contents of this chapter encompass general problems and the most important issues of power-supply-quality improvement in AC systems. In the context of the above, consideration is given to evaluation of bilateral interactions of receivers with an electrical power-distribution system and methods of their reduction. Also are discussed the basis of operation of the most important compensation-filtration devices and their applications...
-
Design advantages and analysis of a novel five-phase doubly-fed induction generator
PublikacjaPurpose – The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approach – This paper presents the results of a research work related to fivephase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based...
-
Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response
PublikacjaIn this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...
-
Wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego sterowanego ze sprzężeniem od prądu zasilającego
PublikacjaW artykule przedstawiono wpływ uwarunkowań rzeczywistych na pracę równoległego filtru aktywnego i zdolność kompensacji prądów harmonicznych. Zbadano wpływ opóźnień czasowych wynikających z implementacji cyfrowej sterowania, wpływ impedancji zwarciowej sieci zasilającej oraz błędów generowania napięcia przekształtnika na jakość kompensacji filtru. Badania symulacyjne przeprowadzono dla trzech układów sterowania: otwartego, zamkniętego...
-
WATER SUPPLY AND WASTEWATER DISPOSAL
Kursy OnlineThe course on Water Supply and Wastewater Disposal provides a comprehensive understanding of the principles, practices, and technologies involved in managing water resources effectively. It covers both the supply side, focusing on the provision of clean and safe drinking water, and the disposal side, addressing the treatment and management of wastewater to minimize environmental impact. Key Topics Covered: 1. Introduction to...
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublikacjaIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
The Conceptual Research over Low-Switching Modulation Strategy for Matrix Converters with the Coupled Reactors
PublikacjaIn this paper, different Pulse Width Modulation (PWM) strategies for operating with a low-switching frequency, a topology that combines Conventional Matrix Converters (CMCs), and Coupled Reactors (CRs) are presented and discussed. The principles of the proposed strategies are first discussed by a conceptual analysis and later validated by simulation. The paper shows how the combination of CMCs and CRs could be of special interest...
-
An Overview of Bidirectional EV Chargers: Empowering Traction Grid-Powered Chargers
PublikacjaIn recent years, the number of electric vehicles has been at least doubling year after year. As a result, today electric vehicles already account for approximately 10% of the global automotive market, which positively affects environment in urbanized areas. However, to take full advantage of the EV integration it is necessary to use renewable sources for their charging; optimally place charging stations/terminals; optimally manage...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublikacjaLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublikacjaThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublikacjaIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
Sensorless induction motor drive with voltage inverter and sine-wave filter
PublikacjaThis paper presents a speed sensorless control system of an induction motor with an output LC filter. It is known that the parameters design of the filter gives sine wave motor supply voltage but complicates control and estimation process. The reason is that the voltage drop and phase shift between filter input and output signals are imposed, and hence the motor voltages and currents differ from the inverter output waveforms. To...
-
Light-Powered Starter for Micro-Power Boost DC–DC Converter for CMOS Image Sensors
PublikacjaThe design of a starter for a low-voltage, micro-power boost DC–DC converter intended for powering CMOS image sensors is presented. A unique feature of the starter is extremely low current, below 1 nA, supplying its control circuit. Therefore, a high-voltage (1.3 V) configuration of series-connected photovoltaic diodes available in a standard CMOS process or a small external LED working in photovoltaic mode can be used as an auxiliary...
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublikacjaCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
Modeling of Electrified Transportation Systems Featuring Multiple Vehicles and Complex Power Supply Layout
PublikacjaThe paper proposes a novel approach to modeling electrified transportation systems. The proposed solution reflects the mechanical dynamics of vehicles as well as the distribution and losses of electric supply. Moreover, energy conversion losses between the mechanical and electrical subsystems and their bilateral influences are included. Such a complete model makes it possible to replicate, e.g., the impact of voltage drops on vehicle...
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublikacjaThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Resonant Conditions in a Node with an SVC Compensator
PublikacjaThe primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.
-
Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
PublikacjaIn this paper, a tuning method of a resonant circuit suited for wireless powering of miniature endoscopic capsules is presented and discussed. The method allows for an automatic tuning of the resonant frequency and matching impedance of a full wave rectifier loading the resonant circuit. Thereby, the receiver tunes so as to obtain the highest power efficiency under given conditions of transmission. A prototype receiver for wireless...
-
Niskonapięciowy filtr analogowy CMOS oparty o konwerter ujemno-impedancyjny
PublikacjaA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
Niskonapięciowy filtr analogowy CMOS wykorzystujący konwerter ujemnoimpedancyjny
PublikacjaA low-voltage 3-order low-pass CMOS filter based on the novel current inversion type negative impedance converter (CNIC) is presented. It shows a badwidth of 10 MHz at 400 uW power consumption and 2 V supply voltage when realized in a 0.35 um CMOS process.
-
TRANSFER OF ELECTRIC ENERGY [2023/24]
Kursy OnlineCourse content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...
-
TRANSFER OF ELECTRIC ENERGY [2022/23]
Kursy OnlineCourse content: Basic information on the structure of the power system, the major devices (components) for generation, transmission and distribution of electricity. Active and reactive power generation and their sources. Power supply networks. Tasks, structure, parameters. AC and DC transmission of electricity. Equivalent diagrams of the components of the power system. Steady state load flow calculation: currents, voltage,...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
A robust 18-pulse diode rectifier with coupled reactors
PublikacjaThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Five-phase induction motor drive with sine-wave filter
PublikacjaThe paper presents closed loop ac drive with 5 phase induction motor operating with voltage source inverter and sine wave filter. The motor supply voltages and currents have sinusoidal shape. For well known adjustable electric drives the field oriented control method with flux and speed co ntrol can be applied. In the presence of output filter both control and estimation algorithms should be modified due to sine wave filter installation....
-
Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors
PublikacjaIn this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field...
-
Unity-Gain Zero-Offset CMOS Buffer with Improved Feedforward Path
PublikacjaA voltage unity-gain zero-offset CMOS amplifier with reduced gain error and increased PSRR (power supply rejection ratio) is proposed. The amplifier uses two feed mechanisms, negative feedback and supporting positive feedforward, to achieve low deviation from unit gain over the entire input range. The circuit, designed in a standard 180-nanometer 1.8-voltage CMOS process, is compared with two known buffers of similar topology,...
-
Higher harmonics produced by traction substations – computer modelling and experimental verification
PublikacjaVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers, although the rms value of load current does not exceed their current-carrying capacity. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion...
-
Kamila Kokot-Kanikuła mgr
OsobyKamila Kokot-Kanikuła pracuje w Bibliotece Politechniki Gdańskiej w Sekcji Budowy Zbiorów Cyfrowych i Multimedialnych na stanowisku starszego bibliotekarza. Jest absolwentką Instytutu Historycznego oraz Informacji Naukowej i Bibliotekoznawstwa na Uniwersytecie Wrocławskim. Główne kierunki zainteresowań to starodruki, biblioteki cyfrowe, repozytoria instytucjonalne, Otwarte Zasoby Edukacyjne, Open Access i Open Data. W bibliotece...
-
Asymmetrical Modes in Polyphase Motors and Drives
PublikacjaThe effect of power supply and/or motor asymmetry on the phase-load distribution and the ripple of electromagnetic torque in a polyphase drive is studied by the method of symmetrical components. It is shown that the presence of asymmetry causes the mapping of all harmonics in the supply voltage into all planes of symmetrical components and eliminates the possibility of independent control of harmonics. The dynamic model of a five-phase...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Analiza ruchowa pojazdów szynowych z uwzględnieniem zmian napięcia na odbieraku prądu
PublikacjaW artykule zaproponowano metodykę wykonywania analizy ruchowej pojazdów szynowych, która uwzględnia wpływ zmieniającego się napięcia zasilającego pojazd a jego właściwości ruchowe. Wykorzystując model opracowany w programie Simulink wskazano na istotne różnice w czasie przejazdu oraz w wartościach napięcia zasilającego pomiędzy proponowanym sposobem analizy a powszechnie stosowanym podejściem uproszczonym.
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublikacjaW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublikacjaPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
A 1-nS 1-V Sub-1-µW Linear CMOS OTA with Rail-to-Rail Input for Hz-Band Sensory Interfaces
PublikacjaThe paper presents an operational transconductance amplifier (OTA) with low transconductance (0.62–6.28 nS) and low power consumption (28–270 nW) for the low-frequency analog front-ends in biomedical sensor interfaces. The proposed OTA implements an innovative, highly linear voltage-to-current converter based on the channel-length-modulation effect, which can be rail-to-rail driven. At 1-V supply and 1-Vpp asymmetrical input driving,...
-
Computer System for Evaluation of Shock Hazard in Circuits with Non-sinusoidal Earth Currents
PublikacjaEffects of current on people are mainly considered for 50/60 Hz sinusoidal current and smooth direct current. However, modern low voltage circuits are very often equipped with power electronics converters – rectifiers, frequency converters, therefore non-sinusoidal earth currents (touch currents) occur. For non-sinusoidal currents safety criteria should be modified. This paper presents a computer system, based on LabVIEW environment,...
-
LabVIEW-based intelligent system of protection against electric shock for photovoltaic installations
PublikacjaEvaluation of shock hazard in installations with photovoltaic sources of energy is more complicated than in a conventional low voltage system. In case of earth fault in photovoltaic generators, that are connected to the AC power public grid, a composite waveform of earth fault current in the installation may occur. For composite waveforms, the safety criteria should be modified. The paper considers the effect of the composite waveforms...
-
Determining the leakage current resistive component by the orthogonal vector method
PublikacjaThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
Leakage Current Measurements of Surge Arresters
PublikacjaThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
System of protection against electric shock for circuits with power electronics converters
PublikacjaModern low voltage circuits are very often equipped with power electronics converters, therefore in these circuits non-sinusoidal earth currents (touch currents) may occur. For non-sinusoidal currents safety criteria should be modified. This paper presents these modified criteria and a computer system of protection against electric shock which can be implemented in circuits with power electronics converters. The system is based...
-
EMC disturbances in connection of driving system
PublikacjaIt is known the steep voltage changes caused by IGBT frequency inverters may cause some electromagnetic problems in driving system. Special dU/dt type as well as sinusoidal filters are used in order to limit the level of the disturbances. The paper presents investigation results of EMC disturbances in inverter supplied induction motor. Experiments have proved that disturbances in current connection differ essentially. Important...
-
Failure analysis of a high-speed induction machine driven by a SiC-inverter and operating on a common shaft with a high-speed generator
PublikacjaDue to ongoing research work, a prototype test rig for testing high-speed motors/generators has been developed. Its design is quite unique as the two high- speed machines share a single shaft with no support bearings between them. A very high maximum operating speed, up to 80,000 rpm, was required. Because of the need to minimise vibration during operation at very high rotational speeds, rolling bearings were used. To eliminate...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublikacjaThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublikacjaThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Diagnosis of bearing damage in induction motors by instantaneous power analysis
PublikacjaResearch of the machine with simulated bearing damages has been carried out, where variable load torque, simulating bearing damage, was introduced. The results show that components which can be used for bearings diagnosis appear in the spectrum of the product of current and supply voltage instantaneous values. These components are easier to identify than the components of current spectrum, which have been used so far in diagnostic...
-
Remote current measurement with FPGA digital processing
PublikacjaThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Regulacja napięcia w sieci nN z rozproszonymi źródłami energii
PublikacjaPodłączanie rozproszonych źródeł energii do sieci energetycznych niskiego napięcia powoduje powstawanie problemów zmienności i niesymetrii napięcia, zwłaszcza w przypadku dużych odległości od transformatora zasilającego. W skrajnych przypadkach zachodzi konieczność redukcji mocy generowanej przez źródło podczas oddawaniu energii do sieci. Rozwiązaniem tego problemu jest zastosowanie energoelektronicznego regulatora napięcia składającego...
-
Nowoczesne układy przekształtników wielopoziomowych do zasilania statków z lądu
PublikacjaW artykule poruszono tematykę zasilania statków zacumowanych w porcie z lądowej sieci elektroenergetycznej poprzez wykorzystanie nowoczesnych konstrukcji przekształtników energoelektronicznych. W treści pracy zaprezentowano porównanie dwóch topologii wysokonapięciowych przekształtników wielopoziomowych. Porównano konstrukcje przekształtników z klasycznym transformatorem wielouzwojeniowym oraz z transformatorami wysokoczęstotliwościowymi.
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublikacjaLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Pompownie dużej mocy z falownikiem wędrującym średniego napięcia
PublikacjaArtykuł zawiera rys rozwoju napędów przekształtnikowych w stacjach pomp, w szczególności regulacji wydatku kilku pomp, po kolei, przez jeden przemiennik częstotliwości. Omówiono podstawy teoretyczne zjawiska pola niestłumionego i napięcia resztkowego silników, które utrudniają szybkie przełączania silnika pompy pomiędzy zasilaniem regulowanym przez falownik a zasilaniem z sieci. Przedstawiono zasady transferu (przełączania) synchronicznego...
-
Control system for contactless electrical energy transfer with varying air gap
PublikacjaInductive power transfer (IPT) is a system by which electrical energy may be transmitted without electrical connection through a large air gap between coils. Systems usually considered in the literature are the ones with a constant air gap. The paper describes the analysis of IPT, which allows for supplying an electrical load in the conditions of slow, in relation to the dynamics of power supply, changes in the dimensions of the...
-
Ladder-Based Synthesis and Design of Low-Frequency Buffer-Based CMOS Filters
PublikacjaBuffer-based CMOS filters are maximally simplified circuits containing as few transistors as possible. Their applications, among others, include nano to micro watt biomedical sensors that process physiological signals of frequencies from 0.01 Hz to about 3 kHz. The order of a buffer-based filter is not greater than two. Hence, to obtain higher-order filters, a cascade of second-order filters is constructed. In this paper, a more...
-
Badania laboratoryjne wybranych sposobów koordynacji regulatora transformatora blokowego oraz regulatora generatora
PublikacjaWprowadzenie wymogu stosowania transformatorów blokowych z przekładnią regulowaną pod obciążeniem spowodowało konieczność określenia właściwego sposobu podziału kryteriów sterowania pomiędzy regulator generatora a regulator transformatora blokowego. W referacie zwrócono uwagę na aspekt miejsca pomiaru napięć. Ma to istotny wpływ zarówno na algorytm jak i jakość regulacji. Rozważania teoretyczne zilustrowane zostały wynikami prób...
-
Rola i znaczenie zbiornika sieciowego w kształtowaniu hydrauliki i jakości wody w systemie wodociągowym
PublikacjaEksploatacja zbiornika sieciowego powinna zapewniać cykliczną wymianę wody w jego komorach. Koniecznym warunkiem prawidłowej eksploatacji zbiornika jest zgodność założeń projektowych ze stanem faktycznym. Praktyka eksploatacyjna wskazuje na szereg nieprawidłowości w tym względzie. Z powodu lokalizacji zbiornika sieciowego za nisko lub za wysoko albo wskutek błędów popełnionych w ustaleniu jego parametrów obserwuje się niestabilność...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublikacjaMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Analysis of energy efficiency of suburban railway transport network
PublikacjaRising numbers of agglomeration residents cause increased need for people movement on daily basis. Because of congestion of local roads, air pollution and limited parking space, providing mass transit based on electric traction is reasonable. While the electric rail vehicles are considered highly efficient in themselves, they need to be analyzed as a part of a transport network, because energy consumption depends on operating conditions...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublikacjaNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Multiple output CMOS current amplifier
PublikacjaIn this paper the multiple output current amplifier basic cell is proposed. The triple output current mirror and current follower circuit are described in detail. The cell consists of a split nMOS differential pair and accompanying biasing current sources. It is suitable for low voltage operation and exhibits highly linear DC response. Through cell devices scaling, not only unity, but also any current gains are achievable. As...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublikacjaThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
The Influence of LED Lighting Sources on the Nature of Power Factor
PublikacjaThis article presents measurements of electric power absorbed by a newly built facility for office and scientific research activities. These measurements highlighted the need for compensation of capacitive reactive power—not predicted by the designer—due to the vast use of LED lighting in the facility. The article also describes a reactive power compensation system, designed on the basis of the above-mentioned measurements, and...
-
WARUNKI REZONANSOWE W WĘŹLE Z KOMPENSATOREM SVC
PublikacjaInstalowanie kompensatorów statycznych w sieciach rozdzielczych i przesyłowych służy poprawie profili napięciowych. Kompensatory jako źródła mocy biernej zwiększają stabilność napięciową systemu. Pozwalają także na szybszą odbudowę systemu w przypadku awarii napięciowej. W artykule zaprezentowano wpływ struktury i wysterowania układu SVC na zmianę impedancji w układzie zasilania. Ma to bezpośredni wpływ na częstotliwości, przy...
-
Prądy łożyskowe w układach napędowych z silnikami indukcyjnymi
PublikacjaW pracy przedstawiono problemy występujące w układach napędowych z silnikami indukcyjnymi zasilanymi z falownika napięcia. Zwrócono uwagę na rosnącą liczbę uszkodzeń silników w napędach przekształtnikowych. Wskazano przyczyny wynikające z charakteru zasilania przekształtnikowego silnika. Główną uwagę poświęcono prądowi łożyskowemu, który odpowiada za większość awarii maszyn. Przedstawiono rodzaje prądów łożyskowych, wyjaśniając...
-
Raman miniaturised system for field applications
PublikacjaRaman spectroscopy is a powerful and versatile research technique with a broad range of potential applications, which includes laboratory studies, on-line industrial process monitoring and field measurements. Scope of the field applications includes environment monitoring, detection of dangerous or prohibited materials and rapid identification of unknown samples. It stimulates development of dedicated Raman measurement equipment...