Search results for: PULSE SIGNAL - Bridge of Knowledge

Search

Search results for: PULSE SIGNAL

Filters

total: 283
filtered: 196

clear all filters


Chosen catalog filters

  • Category

  • Year

  • Options

clear Chosen catalog filters disabled

Search results for: PULSE SIGNAL

  • Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors

    This paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...

    Full text available to download

  • Directed electromagnetic pulse dynamics: projecting operators method

    In this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...

    Full text to download in external service

  • Influence of preprocessing techniques on pulse pressure velocity determination

    Publication

    Pulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...

    Full text to download in external service

  • Modular multipulse voltage source inverters with integrating coupled reactors

    Publication

    - Year 2016

    A novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...

    Full text to download in external service

  • The forming and emission of high power electromagnetic pulses

    Publication

    An impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by an...

    Full text to download in external service

  • The Influence of Laser Alloying of Ti13Nb13Zr on Surface Topography and Properties

    The laser alloying is a continually developing surface treatment because of its significant and specific structuration of a surface. In particular, it is applied for Ti alloys, being now the most essential biomaterials` group for load-bearing implants. The present research was performed on the Ti13Nb13Zr alloy subject to laser modification in order to determine the treatment effects on surface topography and its some mechanical...

    Full text available to download

  • The forming and emission of high power electromagnetic pulses

    Publication

    An impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by...

    Full text to download in external service

  • Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter

    Publication

    - Year 2016

    The paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...

    Full text to download in external service

  • A robust 18-pulse diode rectifier with coupled reactors

    The article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...

    Full text available to download

  • A concept of software extension of 3D low-PRF radar systems to 4D semi-medium-PRF radar systems

    Publication

    We present a concept of software modification of three-dimensional (3D) radar systems, designed to work in the low pulse repetition frequency mode, that equips them with the ability to estimate the radial velocity and to properly measure the range of targets that are detected outside the radar’s instrumented range. Despite the fact that the proposed modifications are designed so as to require only minor changes in software, they...

    Full text available to download

  • Can we rely on the pulse transit time - pressure relationship - models comparison

    Publication

    An unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...

    Full text to download in external service

  • Remote Estimation of Video-Based Vital Signs in Emotion Invocation Studies

    Abstract— The goal of this study is to examine the influence of various imitated and video invoked emotions on the vital signs (respiratory and pulse rates). We also perform an analysis of the possibility to extract signals from sequences acquired with cost-effective cameras. The preliminary results show that the respiratory rate allows for better separation of some emotions than the pulse rate, yet this relation highly depends...

    Full text available to download

  • Multi-pulse VSC arrangements with coupled reactors

    Publication

    - Year 2016

    This paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...

    Full text to download in external service

  • Directed pulse dynamics

    Publication

    Introducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.

    Full text to download in external service

  • Propagation of acoustic pulses in some fluids with yield stress

    Publication

    This study is devoted to the derivation of approximate equations governing acoustic pulses in flows with yieldstress, including some time-dependent flows with a slow dependence on time of yield stress and apparent viscosity. Themodeling of yield stress and apparent viscosity in the vicinity of a zero deformation rate allows us to consider a thixotropicfluid as a Bingham plastic with coefficients that are dependent on time. The...

    Full text available to download

  • Ultrashort Opposite Directed Pulses Dynamics with Kerr Effect and Polarization Account

    We present the application of projection operator methods to solving the problem of the propagation and interaction of short optical pulses of different polarizations and directions in a nonlinear dispersive medium. We restrict ourselves by the caseof one-dimensional theory, taking into account material dispersion and Kerr nonlinearity. The construction of operators is delivered in two variants: for the Cauchy problem and for the...

    Full text to download in external service

  • New Architecture of Solid-State High-Voltage Pulse Generators

    Publication

    - ENERGIES - Year 2022

    The application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...

    Full text available to download

  • A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux

    Publication

    - ENERGIES - Year 2020

    In this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...

    Full text available to download

  • Control strategy for the multilevel cascaded H-bridge converter

    Publication

    - Year 2013

    The paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.

    Full text to download in external service

  • A new duty cycles calculation method in pulse width modulation for direct matrix converters based on the shape function concept

    Publication

    - Year 2013

    Paper presents a new approach to duty cycle calculation in pulse width modulation for direct matrix converters. The essence of the proposed method is the use of elementary shape function of finite element. The algorithm for calculating the duty cycles was reduced to simple operations on the coordinates of input and output voltage vectors without trigonometric functions.

    Full text to download in external service

  • Enhanced Remote Control Providing Medical Functionalities

    This paper presents the enhanced remote control and its role in pervasive healthcare in the home. The device was equipped with health-related measurement modules and a message-processing unit. Preliminary results are presented for monitoring of a pulse, hand tremors, grip forces, and for self­ evaluation procedures. The interaction of the device with the smart environment is presented and discussed.

    Full text to download in external service

  • Electrodeposited Biocoatings, Their Properties and Fabrication Technologies: A Review

    Publication

    Coatings deposited under an electric field are applied for the surface modification of biomaterials. This review is aimed to characterize the state-of-art in this area with an emphasis on the advantages and disadvantages of used methods, process determinants, and properties of coatings. Over 170 articles, published mainly during the last ten years, were chosen, and reviewed as the most representative. The most recent developments...

    Full text available to download

  • Studying the Effect of Working Conditions on WEDM Machining Performance of Super Alloy Inconel 617

    Publication

    Wire electrical discharge machining (WEDM) has been for many years a precise and efficient non-conventional manufacturing solution in various industrial applications, mostly involving the use of hard-to machine materials like, among other, the Inconel super alloys. The focus of the present study is on exploring the effect of selected control parameters, including pulse duration, pulse-off time and the dielectric flow pressure on...

    Full text available to download

  • The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard

    Publication

    - Year 2016

    In this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...

    Full text to download in external service

  • Femtosecond Er-doped fiber laser source tunable from 872 to 1075 nm for two-photon vision studies in humans

    Publication
    • D. Stachowiak
    • M. J. Marzejon
    • J. Bogusławski
    • Z. Łaszczych
    • K. Komar
    • M. Wojtkowski
    • G. Soboń

    - Biomedical Optics Express - Year 2022

    We report the development of a widely-tunable femtosecond fiber laser system and its application for two-photon vision studies. The source is based on an Er-doped fiber laser with spectral shift up to 2150 nm, followed by a second harmonic generation module to generate a frequency-doubled beam tunable from 872 to 1075 nm. The source delivers sub-230 fs pulses with nearly-constant duration over the entire tuning range, with output...

    Full text available to download

  • Radar time budget optimization subject to angle accuracy constraint via cognitive approach

    Publication

    - Year 2017

    The problem of minimizing dwell time in multifunction phased array radar is considered. Target of interest is assumed to fluctuate according to a generalization of Swerling family and the parameters of fluctuation model are assumed to be known. The a'priori position of the target is uncertain. Optimization, whose variables include pulse count and array transmit beampattern, is carried out subject to achieving a desired accuracy...

    Full text available to download

  • Gate Driver with Overcurrent Protection Circuit for GaN Transistors

    The improvement of the gate driver for GaN transistor is presented in this paper. The proposed topology contains the overcurrent protectionwith the two-stage turning off and independent control of turn on and off time of the GaN transistor. The operation of driver and its application in thehalf-bridge converter are described using both simulation and prototype measurements. The overcurrent protection was tested in Double Pulse...

    Full text available to download

  • Eksperymentalna analiza modalna stojanów silników indukcyjnych

    Publication

    - Year 2005

    W artykule zaprezentowano technikę pomiarów i wyniki obliczeń postaci drgań własnych badanego stojana silnika indukcyjnego klatkowego. Przedstawiono również teoretyczne podstawy zastosowanej techniki obliczeniowej. Jako narzędzie akwizycji danych wykorzystano pomiarowy system PULSE firmy Brüel&Kjær, a w celu przeprowadzenia koniecznych obliczeń oraz wizualizacji wyników wykorzystano środowisko Matlab.

  • A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model

    A new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...

    Full text available to download

  • A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers

    Publication

    A new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...

    Full text available to download

  • Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions

    Publication

    - Year 2018

    Abstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...

    Full text available to download

  • Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls

    Publication

    - BIOSENSORS & BIOELECTRONICS - Year 2019

    Two different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...

    Full text available to download

  • Compact and Integrated High-Power Pulse Generation and Forming System

    This paper presents comprehensive analytical, numerical and experimental research of the compact and integrated high-power pulse generation and forming system based on the flux compression generator and the electro-explosive forming fuse. The paper includes the analysis of the presented solution, starting from the individual components studies, i.e., the separate flux compression generator tests in field conditions and the forming...

    Full text available to download

  • FFT spectrum based matching algorithm for activedynamic thermography

    Publication

    - QIRT Journal - Year 2010

    In Active Dynamic thermography (ADT) sequences of consecutive temperature distributions are analyzed. In biomedical applications of ADT, the problems of a patient's movements in front of a thermal camera should be eliminated before data analysis. Complete mechanical stabilization of the patients is impossible due to natural voluntary and involuntary moves caused by pulse breathing, etc. This paper presents a simple and efficient...

    Full text to download in external service

  • Application of the laser diode with central wavelength 975 nm for the therapy of neurofibroma and hemangiomas

    Publication

    - JOURNAL OF BIOMEDICAL OPTICS - Year 2017

    This paper presents newly developed dermatological laser (with central wavelength 975 nm) for application in therapies requiring deep penetration of tissue, e.g. cutaneous (dermal) neurofibroma (Recklinghausen disease) and hemangiomas. This laser can work either in pulse or continues wave mode. Laser radiation is transmitted toward the application region by optical fiber with a diameter of 0.6 mm. The compact design of the laser...

    Full text available to download

  • Blood Pressure - Pulse Transit Time Relationships: Comparative Studies

    Publication

    A non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...

    Full text to download in external service

  • DC-link voltage balancing in cascaded H-Bridge converters

    In the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...

    Full text available to download

  • Multipulse inverter structures with low voltage distortion

    Publication

    - Year 2016

    A novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...

    Full text to download in external service

  • A New Three-Dimensional Space Vector Modulation for Multilevel Four-Leg Converters Based on the Shape Functions of Tetrahedral Element

    The paper proposes a new three-dimensional space vector pulse-width modulation (3D-SVPWM) algorithm for multilevel four-leg converters. The proposed PWM duty cycle calculation is based on the shape functions of the threedimensional tetrahedral finite elements. The algorithm ensures synthesis of accurate and undistorted output voltages even under significant imbalance or ripple in the DC-link voltages. At the same time, the algorithm...

  • Evaluation of the fast impedance spectroscopy method in the laboratory measurement system

    Publication

    In this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...

    Full text to download in external service

  • Determination of Antioxidant Activity of Vitamin C by Voltammetric Methods

    Voltammetric methods—cyclic (CV) and differential pulse voltammetry (DPV) are considered the most appropriate way to evaluate antioxidant activity of redox active compounds. They provide information about both mechanism and kinetics of electrochemical oxidation of antioxidants as well as their physical and chemical properties such as the redox potential or the number of electrons transferred. These methods are helpful for understanding...

    Full text available to download

  • Four Level Diode-Clamped Back-To-Back Converter with Active DC Link Voltage Control

    Publication

    - Year 2013

    This article presents the design and control of 4L-DC back-to-back converter. To solve the DC link voltage balancing problem in four-level converter a new three-level double chopper topology based on PO-PWM modulation was designed and successfully tested. Also, the paper describes two phase space vector pulse width modulation 2P-SVPWM based on the shape function of finite elements. The control structure with modified Dead-Beat...

    Full text to download in external service

  • Accuracy of the discrete Green's function computations

    Publication

    - Year 2012

    This paper discusses the accuracy of the discrete Green's function (DGF) computations. Recently closed-form expression of the DGF and its efficient numerical implementation were presented which facilitate the DGF applications in FDTD simulations of radiation and scattering problems. By carefully comparing the DGF results to those of the FDTD simulation, one can make conclusions about the range of the applicability of the DGF for...

  • Low harmonic multipulse voltage converters using coupled reactors

    Publication

    - Year 2016

    This paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...

    Full text to download in external service

  • Long-Term Measurement of Physiological Parameters – Child Dataset

    Publication

    - Year 2022

    The dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...

    Full text available to download

  • Machine learning-based prediction of seismic limit-state capacity of steel moment-resisting frames considering soil-structure interaction

    Publication

    Regarding the unpredictable and complex nature of seismic excitations, there is a need for vulnerability assessment of newly constructed or existing structures. Predicting the seismic limit-state capacity of steel Moment-Resisting Frames (MRFs) can help designers to have a preliminary estimation and improve their views about the seismic performance of the designed structure. This study improved data-driven decision techniques in...

    Full text to download in external service

  • Virtual Space Vector Pulse Width Modulation Algorithm for Three-Level NPC Converters Based on the Final Element Shape Functions

    Publication

    The paper puts forth a novel idea for the computation of Nearest Three Virtual Space Vector Pulse Width Modulation for the three level NPC converters. The computations are based on the concept of final element shape function widely used in the domain of finite element analysis. The proposed approach significantly frees the computations from the use of trigonometric functions, which simplifies the computations and permits easier...

  • Modulacja 3D-SVPWM z kompensacją napięcia niezrównoważenia i balansowaniem napięć DC dla czterogałęziowego falownika 3L-NPC

    Publication

    Przedstawiono realizację algorytmu modulacji napięcia 3D-SVPWM (ang. 3-Dimensional Space Vector Pulse Width Modulation) z kompensacją napięcia niezrównoważenia dla trójpoziomowego czterogałęziowego falownika 3L-NPC (ang. 3-Level Neutral-Point-diode-Clamped Converter). Do wyznaczania współczynników wypełnień w modulacji szerokości impulsów zastosowano liniowe funkcje kształtu czworościennego elementu skończonego z węzłami, których...

  • Modified SPWM Technique with Zero-Sequence Voltage Injection for a Five-Phase, Three-Level NPC Inverter

    Publication

    - ENERGIES - Year 2021

    This article presents a modified sinusoidal pulse-width modulation (SPWM) scheme for a five-phase, three-level neutral-point-clamped inverter. The modulation scheme deploys a modified min–max function to inject the zero-sequence components into the reference modulating signals; hence enabling the effective utilization of the DC-link voltage. Balanced split-input DC-link voltages were achieved through further incorporation of adjustable...

    Full text available to download

  • Modulacja 3D-SVPWM dla przekształtników wielopoziomowych czterogałęziowych na bazie funkcji kształtu

    Publication

    - Przegląd Elektrotechniczny - Year 2011

    Przedstawiono realizację algorytmu modulacji napięcia 3D-SVPWM (ang. 3-Dimensional Space Vector Pulse Width Modulation) dla trójpoziomowego czterogałęziowego przekształtnika 3L-NPC (ang. 3-Level Neutral-Point-diode-Clamped Converter). Do wyznaczania współczynników wypełnień w modulacji szerokości impulsów zastosowano liniowe funkcje kształtu czworościennego elementu skończonego. Proponowany algorytm modulacji nie jest ograniczony...