Filters
total: 5565
filtered: 3940
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: LEAKAGE CURRENT MEASUREMENT
-
Analysis of Measurement Errors in Rail Vehicles’ Pantograph Inspection System
PublicationThe paper presents an approach to evaluation of height measurement errors in laser scanning inspection system. The system, consisting of a laser line generator and a specialized camera, is dedicated to diagnosing carbon contact strips of railway vehicles’ pantographs. While height measurement resolution is easily computable based on system parameters, determining the measurement error is troublesome due to numerous impacts. As...
-
Current advances in membrane processing of wines: A comprehensive review
PublicationBackground Membrane-based operations, especially pressure-driven membrane operations, are today well-established procedures for various applications in the wine industry thanks to their intrinsic properties and undoubted advantages over traditional methods. Emerging membrane processes, such as pervaporation, electrodialysis and osmotic distillation, forward osmosis, membrane contactors, offer new and interesting perspectives to...
-
Spectral measurement of birefringence using particle swarm optimization analysis
PublicationThe measurement of birefringence is useful for the examination of both technical and biological objects. One of the main problems is that the polarization state of light in birefringent media changes periodically. Without the knowledge of the period number, the birefringence of a given medium cannot be determined reliably. We propose to analyse the spectrum of light in order to determine the birefringence. We use a Particle Swarm...
-
3D Monitoring - Identification of measurement problems at larger movements of the tracked points
PublicationAuthors identified the problems associated with the determination of the controlled points coordinates by use of automated Total Station placed behind transparent barrier. Important thing in the mentioned analysis was a large change of controlled points position and not stable Total Station’s stand (because of stand’s thermal drift). This two elements, combined with measurement made through glass plate determine the need for impact...
-
The evaluation of the vibration measurement usability of electronic indicator lemag "premet C"
PublicationThe measuring possibilities of modern compression and combustion pressure analyzers are extended with additional functions. One of them is parallel to the pressure measurement, the measurement of vibrations in the region of the cylinder head. The paper presents a general assessment of the vibration measurement function of the electronic indicator LEMAG "PREMET C". This feature is very rarely offered by manufacturers of these devices....
-
Spirometry measurement model - the diagnostic purpose support
Publicationthe paper presents a new model of respiratory mechanism based on the spirometry measurements. the spirometry test assesses the efficiency of the lung ventilation. the respiratory system functioning is based on the ventilation mechanism. thus the quality of the lung depends on the quality of lung ventilation. modelling of the respiratory system supports a diagnostic process. the model parameter estimates are obtained on the basis...
-
Analysis of Vibration and Acoustic Signals for Noncontact Measurement of Engine Rotation Speed
PublicationThe non-contact measurement of engine speed can be realized by analyzing engine vibration frequency. However, the vibration signal is distorted by harmonics and noise in the measurement. This paper presents a novel method for the measurement of engine rotation speed by using the cross-correlation of vibration and acoustic signals. This method can enhance the same frequency components in engine vibration and acoustic signal. After...
-
OPTICAL STRAIN MEASUREMENT OF CONCRETE VERSUS MANUAL EXTENSOMETER MEASUREMENT BASED ON THE TEST RC DEEP BEAM IN A COMPLEX STATE OF STRESS
PublicationThe purpose of this study is to compare the strain measurement techniques of concrete in R-C element subjected to the monotonic load up to the failure. In the analysis manual extensometer methods of measurements and the optical system ARAMIS for non-contact three-dimensional measurements of deformation was used. The test sample was a cantilever deep beam loaded throughout the depth which was a part of the reinforced concrete deep...
-
Requirements for Residual Current Devices Intended for Electric Vehicle Charging Systems
PublicationThe properties of residual current devices have been presented from the point of view of their ability to detect a specific shape of the residual current waveform. Moreover, the standard requirements relating to residual current protection used in electric vehicle charging installations have been pointed out. The operating characteristics of the IC-CPD and RDC-DD protections, which are intended for charging electric vehicles in...
-
Photogrammetric and total station's measurement of compressed column's model
PublicationModelling studies continue to play an important role. One of such study is stress determination in the reinforcement bars of reinforced columns and determine column's axis deformation. The article presents measurements results of control points located on the model of reinforced concrete column. The column was compressed in few series till it's destruction. In this studies, photogrammetric method and total station measurements...
-
Current Challenges in Targeting Tumor Desmoplasia to Improve the Efficacy of Immunotherapy
Publication -
The effect of earth fault current harmonics on tripping of residual current devices
PublicationSzerokie zastosowanie przekształtników, a w szczególności przemienników częstotliwości sprawia, że wyłączniki różnicowoprądowe znajdują się w obwodach, w których może płynąć odkształcony prąd ziemnozwarciowy. Prąd ziemnozwarciowy w obwodach z przemiennikami częstotliwości zawiera harmoniczne, których rząd głównie zależy od częstotliwości PWM. Odkształcony prąd wpływa na poprawne wyzwalanie wyłączników różnicowoprądowych. W artykule...
-
New concept of a measurement probe for high impedance spectrocopy
PublicationArtykuł przedstawia nową koncepcję sondy pomiarowej służącej jako obwód wejściowy analizatora do spektroskopii wysokoimpedancyjnej. Dzięki wykorzystaniu przetwornika prąd na napięcie uzyskano najmniejszy możliwy wpływ pojemności kabli dołączających mierzony obiekt na wynik pomiaru. Przeprowadzono analizę sondy biorąc pod uwagę najważniejsze parametry wpływające na dokładność pomiaru: pojemności pasożytnicze oraz rzeczywiste parametry...
-
Radio Link Measurement Methodology for Location Service Applications
PublicationThe aim of this paper is the methodology of measurements executed in a radio link for the realization of radiolocation services in radiocommunication networks, particularly in cellular networks. The main results of the measurements obtained in the physical layer of the universal mobile telecommunications system (UMTS) are introduced. A new method for the utilization of the multipath propagation phenomenon to improve the estimation...
-
Noise measurement setups for fluctuations enhanced gas sensing
PublicationObserwacje zjawisk fluktuacyjnych w sensorach gazów pozwala zwiększyć czułość i selektywność detekcji gazów. Problemem jest budowa prostego i taniego systemu do obserwacji tych zjawisk. W artykule przedstawiono dwa systemy pozwalające na obserwacje szumów w rezystancyjnych sensorach gazów dostępnych na rynku i prototypowych, wykonanych z warstwy nanocząstek o zbliżonych wymiarach.
-
Measurement microsystem for high impedance spectroscopy of anticorrosion coatings
PublicationW artykule przedstawiono mikrosystem do pomiarów bardzo dużych impedancji ukierunkowany na identyfikację parametrów powłok antykorozyjnych metodą spektroskopii impedancyjnej. Do wyznaczania składowych ortogonalnych sygnałów pomiarowych zastosowano w nim technikę cyfrowego przetwarzania sygnałów. Pozwoliła ona na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich, od ćHz, przy zachowaniu prostej konstrukcji...
-
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublicationThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
An Experimental Study of Emission and Combustion Characteristics of Marine Diesel Engine in Case of Cylinder Valves Leakage
Publication -
Measurement system based on USB Z-Wave controller
PublicationA wireless measurement system based on the Z-Wave standard is presented in this paper. The system is composed of a U SB Z-Stick Gen5 controller connected to a Personal Computer and a Fibaro controller FGRGBWM-441. Operation of the system is controlled by software written in C++ using OpenZWave library. Some metrological aspects of the system are evaluated: accuracy, linearity, resolution and frequency of voltage measurements.
-
Automated Diagnostics of Current Pick-Up Disturbances in Electric Traction Networks
PublicationThe present work defines the basic causes of bow disturbances of current pick-up, sets a task of establishing a system of automated control of bow disturbances at feeder zones of electric traction networks, proposes structural variants of the technical system implementation, describes the algorithm of detection of bow disturbances of current pick-up.
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Testing of Software for the Planning of a Linear Object GNSS Measurement Campaign under Simulated Conditions
PublicationThe precision of a linear object measurement using satellite techniques is determined by the number and the relative position of the visible satellites by the receiver. The status of the visible constellation is described by DOP. The obtained geometric coefficient values are dependent on many variables. When determining these values, field obstacles at the receiver location and satellite positions changing with time must be taken...
-
How to apply the probabilistic model of measurement processes successfully
PublicationApplicational aspects of probabilistic model of measurement processes, proposed by G.B. Rossi, are considered. The main idea of the model - using of Bayes-Laplace postulate for solution of inverse probability problem, is substituted by Fisher's concept of the likelihood function, expressed in the data translated format. This approach gives a clear-sighted solution of inverse probability. Some recommendations for application of...
-
INFLUENCE OF WRONGLY ASSUMED PROBABILITY DISTRIBUTION ON THE UNCERTAINTY OF RESISTANCE MEASUREMENT BY TECHNICAL METHOD
PublicationThe paper presents studies on the influence of probability distributions on the expanded uncertainty of the resistance measurement. Choosing the correct probability distribution is very important to estimate of measurement uncertainty. The most commonly used distribution is the rectangular distribution. The paper presents the results of analysis of the resistance measurement uncertainty using the technical method of two resistances:...
-
Nanocrystalline diamond sheets as protective coatings for fiber-optic measurement head
PublicationFiber-optic sensors find numerous applications in science and industry, but their full potential is limited because of the risk of damaging the measurement head, in particular, due to the vulnerability of unprotected tips of the fiber to mechanical damage and aggressive chemical agents. In this paper, we report the first use of a new nanocrystalline diamond structure in a fiber-optic measurement head as a protective coating of...
-
Measurements and Analysis of Motor Supplying Current Waveform for Diagnostic Purposes
PublicationPodano proponowaną metodę diagnostyki łożysk tocznych w silnikach indukcyjnych poprzez pomiar i analizę prądu zasilającego. Przedstawiono opracowany system pomiarowy oraz wyniki badań na łożyskach o specjalnie wprowadzonych uszkodzeniach.
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublicationIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Old-timer Vehicle - Braking Efficiency Measurement at Vehicle Inspection Stations and Roadworthiness Validity Certificate.
PublicationObtaining the Roadworthiness Validity Certificate for an old-timer vehicle involves an appropriate test performance, namely, "Old-timer Vehicle Technical Specification Compliance Test". It seems obvious that this kind of test should include a considerable checklist, however, the current legal regulations connected with this test are not specific enough. One of the certificates issued on this test results is "Old-timer Vehicle Technical...
-
Method of sacrificial anode dual transistor-driving in stray current field
PublicationIn order to control a magnesium anode in a stray current interference field, a dual transistor driving system has been proposed. It consisted of a combination of PNP and NPN transistors. Dual transistor driven system and direct anode to cathode connection were electrochemically tested in 3% NaCl solution. The dual transistor driven system increased the anode efficiency and reduced hydrogen evolution and the risk of embrittlement....
-
Distributed measurement system with data transmission secured using XXTEA algorithm
PublicationThe paper deals with wireless data transmission security in the distributed measurement and control system. An overview of cryptographic algorithms was presented paying special attention to the algorithm dedicated to units with low processing power, which is important due to minimization of energy consumption. Measurement modules equipped with simple microcontrollers send data wirelessly to the central unit. The transmission was...
-
Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants
PublicationThe study presents information about the measurement techniques used for the assessment of air quality in terms of the olfactory intensity resulting from the operation of municipal sewage treatment plants. Advantages and disadvantages of the measurement techniques used are presented. Sources of malodourous substance emission from sewage treatment plants were described, and the malodourous substances emitted were characterised....
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Comparison of Different Measurement Techniques as Methodology for Surveying and Monitoring Stainless Steel Chimneys
PublicationThe measurement of a chimney axis is an engineering geodesy task. These measurements allow to assess the technical condition of chimneys and are usually carried out for reinforced concrete chimneys. When measuring high chimneys, the main problem may be the need to go a long distance to take a measurement. The surface of the chimney can also be problematic because it can absorb so much light from the range finder that total station...
-
Time-current tripping curves of arc fault detection devices
PublicationTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Modular high precision high current source for special applications — Simulation and verification
PublicationThis paper presents selected issues concerning realization of high precision high current source for special applications, where high demands of output parameters of such device are required. A new 80 kW prototype of modular high precision high current source is presented, where output current accuracy reaches 5x10-5. This paper presents also results of operation of the simulation model and of the prototype converter. In order...
-
Comparison of residual current devices tripping characteristics for selected residual current waveforms
PublicationZgodnie z normami międzynarodowymi, w instalacjach o zwiększonym ryzyku porażenia prądem elektrycznym należy stosować wyłączniki różnicowoprądowe wysokoczułe. Dla zapewnienia skutecznej ochrony przeciwporażeniowej zainstalowany wyłącznik różnicowoprądowy powinien prawidłowo wykrywać określony kształt prądu różnicowego. W artykule przedstawiono charakterystyki działania wyłączników różnicowoprądowych przy wybranych przebiegach odkształconego...
-
Measurement of complex refractive index of human blood by low-coherence interferometry
PublicationIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Mobility management solutions for current IP and future networks
PublicationEnormous progress in the design of portable electronic devices allowed them to reach a utility level comparable to desktop computers, while still retaining their mobility advantage. At the same time new multimedia services and applications are available for IP users. Unfortunately, the performance of base IP protocol is not satisfactory in mobile environments, due to lack of handover support and higher layer mobility management...
-
Speed sensorless induction motor drive with predictive current controller
PublicationToday, speed sensorless modes of operation are becoming standard solutions in the area of electric drives. This paper presents a speed sensorless control system of an induction motor with a predictive current controller. A closed-loop estimation system with robustness against motor parameter variation is used for the control approach. The proposed algorithm has been implemented using field-programmable gate arrays (FPGAs) and a...
-
Supply current signal and artificial neural networks in the induction motor bearings diagnostics
PublicationThis paper contains research results of the diagnostics of induction motor bearings based on measurement of the supply current with usage of artificial neural networks. Bearing failure amount is greater than 40% of all engine failures, which makes their damage-free operation crucial. Tests were performed on motors with intentionally made bearings defects. Chapter 2 introduces the concept of artificial neural networks. It presents...
-
The Double Cognitive Bias of Mistakes: A Measurement Method
PublicationThere is no learning without mistakes. However, making mistakes among knowledge workers is s�ll seeing shameful. There is a clash between posi�ve a�tudes and beliefs regarding the power of gaining new (tacit) knowledge by ac�ng in new contexts and nega�ve a�tudes and beliefs toward accompanying mistakes that are sources of learning. These contradictory a�tudes create a bias that is doubled by the other shared solid belief...
-
Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer
PublicationThe discords concerning the measurement uncertainty evaluation in the Guide to the Expressing of Uncertainty in Measurement (GUM) and its Supplement 1 are considered. To overcome these discords, the authors of the paper propose to use the kurtosis method and the law of the propagation of the expanded uncertainty. Using the example of the goniometer calibration, the features of accounting for the distribution laws of input quantities...
-
Revisiting the Measurement of Anomie
Publication -
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Sensorless Control of Induction Machine Supplied by Current Source Inverter
PublicationThe paper describes the voltage control technique of induction machines supplied by a current source inverter. The control system is based on proposed new multi-scalar variables, which are named “r.” The control system contains the output filter capacitor's model. In the sensorless control system the Z type backstepping speed observer was applied. The mathematical dependences are confirmed by simulation and experimental research.