Filters
total: 3691
filtered: 2881
displaying 1000 best results Help
Search results for: LOW-COHERENCE INTERFEROMETRY
-
Optical low-coherence interferometry for selected technical applications
PublicationW artykule przedstawiono teoretyczne podstawy optycznej interferometrii niskokoherentnej i przedyskutowano jej unikatowe właściwości. Opisano w nim opracowany przez autorów system OCT przeznaczony do badań strukturalnych materiałów technicznych. Badania te obejmują także zmiany stanu polaryzacji promieniowania rozproszonego w badanym obiekcie. W artykule zawarto wyniki badań wybranych materiałów silnie rozpraszających promieniowanie...
-
Fiber-optic temperature sensor using low-coherence interferometry
Publication -
Measurement of complex refractive index of human blood by low-coherence interferometry
PublicationIn this article, the usefulness of the optical technique for measurements of blood complex refractive index has been examined. Measurement of optical properties of human blood is difficult to perform because of its nonuniform nature. However, results of my investigation have shown the usefulness of low-coherencei nterferometry for measurement complex refractive index of human blood. Furthermore, mathematical analysis of spectrum...
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublicationIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Low-coherence method of hematocrit measurement
PublicationDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
Low-coherence method of hematocrit measurement
PublicationW artykule opisano niskokoherencyjna metodę pomiaru hematokrytu krwi.
-
Low-coherence sensors with nanolayers for biomedical sensing
PublicationIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Low-coherence Fiber-Optic Interferometric Sensors
PublicationW artykule porównano parametry metrologiczne zrealizowanych niskokoherencyjnych czujników światłowodowych wykorzystujących interferometr Michelsona oraz Fabry-Perot.
-
Low-Coherence Fibre-Optic Interferometric Sensors
Publication -
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
PublicationOCT to nowa metoda badania wewnętrznych struktur materiałów. Wśród wielu technik detekcji sygnału optycznego wykorzystywanych w OCT najpopularniejszą i najbardziej obiecującą jest OLCR (Opticla-Low Coherence Reflectomerty - reflektometria niskokoherentna). OLCR wykorzystuje szerokopasmowe źródła, których parametry, jak np.: charakterystyka widmowa, charakterystyka szumowa, determinują właściwości metrologiczne systemu OCT. W artykule...
-
Measurement of selected characteristics of low-coherence optical signal sources for optical coherence tomography
Publication -
Low-coherence photonic method of electrochemical processes monitoring
PublicationWe present an advanced multimodality characterization platform for simultaneous optical and electrochemical measurements of ferrocyanides. Specifcally, we combined a fber-optic Fabry– Perot interferometer with a three-electrode electrochemical setup to demonstrate a proof-ofprinciple of this hybrid characterization approach, and obtained feasibility data in its monitoring of electrochemical reactions in a boron-doped diamond flm...
-
The use of low-coherence interferometer for sugar content determination
PublicationIn this article, the implementation of low-coherence interferometer with signal processing in time domain for sugar content determination in aqueous solution is presented. The elaborated measurement set-up was tested with the use of synthesized source made of two low-coherence sources. The use of two sources with dedicated parameters enabled to obtain a proper metrological parameters of the measurement system. The elaborated low-coherence...
-
The low coherence Fabry-Pérot interferometer with diamond and ZnO layers
PublicationThe authors present a fiber-optic Fabry-Pérot interferometer built with the application of diamond and zinc oxide (ZnO) thin layers. Thin ZnO films were deposited on the tip of a standard telecommunication single-mode optical fiber (SMF- 28) while the diamond layer was grown on the plate of silicon substrate. Investigated ZnO layers were fabricated by atomic layer deposition (ALD) and the diamond films were deposited using Microwave...
-
Biophotonic low-coherence sensors with boron-doped diamond thin layer
PublicationLow-coherence sensors using Fabry-Perot interferometers are finding new applications in biophotonic sensing, especially due to the rapid technological advances in the development of new materials. In this paper we discuss the possibility of using boron-doped nanodiamond layers to protect mirror in a Fabry-Perot interferometer. A low-coherence sensor using Fabry-Perot interferometer with a boron-doped nanodiamond (B-NCD) thin protective...
-
The use of thin diamond films in fiber optic low-coherence interferometers”
PublicationIn this paper we present the use of thin diamond films in fiber-optic low-coherence interferometers. Two kinds of diamond surfaces were used: undoped diamond film and boron-doped diamond film. They were deposited on glass plates as well as silicon layers. A conventionally used mirror was used as a reference layer. Diamond films were deposited using Microwave Plasma Enhanced Chemical Vapour Deposition (μPE CVD) system. Measurements...
-
Shaping coherence function of sources used in low-coherent measurement techniques
Publication -
Shaping of coherence function of sources used in low-coherent measurement techniques
PublicationW artykule przedstawiono zależność pomiędzy charakterystyką widmową źródła i ekwiwalentną długością drogi koherencji źródła. Wyniki analizy teoretycznej i symulacji komputerowych wykazały, że użycie źródła syntezowanego wpływa na zmniejszenie wartości ekwiwalentnej długości drogi koherencji. Dodatkowo wykazano, że zmniejszenie ekwiwalentnej długości drogi koherencji można otrzymać poprzez odpowiednie kształtowanie funkcji koherencji...
-
Shaping coherence function of sources used in low-coherent measurement techniques
PublicationW niskokoherencyjnych technikach pomiarowych kształt funkcji koherencji wykorzystywanego źródła ma bezpośredni wpływ na parametry metrologiczne układu pomiarowego. Z tego względu, w wielu aplikacjach niezbędne jest użycie metod pozwalających na zmianę kształtu tej funkcji. W artykule przeanalizowano możliwości kształtowania funkcji koherencji, a przedstawione analizy teoretyczne i wyniki symulacji komputerowych wskazują, że kształtowanie...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
Low-Coherence Interferometric Fiber-Optic Sensors with Potential Applications as Biosensors
PublicationFiber-optic Fabry-Pérot interferometers (FPI) can be applied as optical sensors, and excellent measurement sensitivity can be obtained by fine-tuning the interferometer design. In this work, we evaluate the ability of selected dielectric thin films to optimize the reflectivity of the Fabry-Pérot cavity. The spectral reflectance and transmittance of dielectric films made of titanium dioxide (TiO2) and aluminum oxide (Al2O3) with...
-
An Optical Low-Coherence System for 2-Dimensional Visualization of Thin Polymer Layers
PublicationW artykule omówiono zasadę działania i przedstawiono podstawowe właściwości systemu OCT (Optical Coherence Tomography). Na przykładzie folii polietylenowej przedyskutowano możliwości wykorzystania systemu do badanie wewnętrznej struktury warstwowej obiektów niebiologicznych. Przedstawiono i omówiono wyniki przeprowadzonych badań nad warstwowymi materiałami przeźroczystymi.
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Enhancement of fiber-optic low-coherence Fabry-Pérot interferometer with ZnO ALD films
PublicationIn this paper investigation of the enhanced fiber-optic low coherence Fabry-Pérot interferometer with zinc oxide (ZnO) film deposited by atomic layer deposition (ALD) was presented. Model of the interferometer, which was constructed of single-mode optical fiber with applied ZnO ALD films, was built. The interferometer was also examined by means of experiment. Measurements were performed for both reflective and transmission modes,...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
Publication -
Fiber - optic low-coherence tomography system for visualization of internal structure of ceramic materials
PublicationW artykule przedstawiono światłowodowy system dwuwymiarowej wizualizacji niejednorodnych struktur warstw ceramicznych. Omówiono projekt i fizyczną realizację układu wykorzystującego optyczną, niskokoherentną reflektometrię optyczną, która umożliwia niedestrukcyjne obrazowanie wewnętrznych struktur różnych materiałów. W pracy przedstawiono przykładowe wyniki pomiarów wewnętrznych warstw LSFO.
-
Low-Coherence Interferometer with Nanocrystalline Diamond Films with Potential Application to Measure Small Biological Samples
PublicationThe study investigates a case of a low-coherence fiber-optic Fabry–Prerot interferometer with a nanocrystalline diamond (NCD) mirror. The method of achieving double density of interference fringes is proposed by the application of birefringent material in the cavity of the interferometer. It can be used to reduce sample volume in comparison to conventional interferometers. The use of a biocompatible diamond mirror makes it specifically...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublicationThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
<title>An optical low-coherence system for 2-dimensional visualization of thin polymer layers</title>
Publication -
<title>Fiber-optic low-coherence tomography system for visualization of internal structure of ceramic materials</title>
Publication -
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublicationWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
Computer-aided analysis of signals from a low-coherence Fabry-Perot interferometer used for measurements of biological samples
PublicationThe aim of the study was to develop an automated computer-aided system for analysis of spectrograms obtained from measurements of biological samples performed with a low-coherence Fabry-Pérot interferometer. Information necessary to determine dispersion characteristics of measured materials can be calculated from the positions of the maxima and minima that are present in their spectra. The main challenge faced during the development...
-
Fiber optic low-coherence Fabry-Pérot interferometer with ZnO layers in transmission and reflective mode: comparative study
PublicationA construction of a low-coherence fiber-optic Fabry-Pérot interferometer using a thin ZnO layer as a reflective surfaces was proposed and examined. In the investigated setup, the ZnO layer of thickness 200 nm were deposited on the face of the standard telecommunication single-mode optical fiber (SMF-28). Measurements of interference signal were performed for the interferometer working in the transmission and reflective mode, as...
-
QUASI-DISTRIBUTED NETWORK OF LOW-COHERENCE FIBER-OPTIC FABRY-PÉROT SENSORS WITH CAVITY LENGTH-BASED ADDRESSING
PublicationDistributed measurement often relies on sensor networks. In this paper, we present the construction of low coherent fiber-optic Fabry-Pérot sensors connected into a quasi-distributed network. We discuss the mechanism of spectrum modulation in this type of sensor and the constraints of assembly of such sensors in the network. Particular attention was paid to separate the signals from individual sensors, which can be achieved by...
-
Application of thin dielectric films in low coherence fiber-optic Fabry-Pérot sensing interferometers: comparative study
Publication -
Reliability and Validity of Optoelectronic Method for Biophotonical Measurements
PublicationReliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate...
-
Application of fiber optic sensors using Machine Learning algorithms for temperature measurement of lithium-ion batteries
PublicationOptical fiber sensorsusing low-coherence interferometry require processing ofthe output spectrum or interferogramto quickly and accurately determine the instantaneous value of the measured quantity, such as temperature.Methods based on machine learning are a good candidate for this application. The application of four such methods in an optical fiber temperature sensoris demonstrated.Using aZnO-coated...
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublicationRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...
-
Niskokoherencyjne czujniki światłowodowe wykorzystujące cienkowarstwowe struktury nanodiamentowe
PublicationZnaczny rozwój technologii wytwarzania czujników światłowodowych spowodował, że są one powszechnie dostępne i stosowane w wielu gałęziach przemysłu, nauki oraz medycyny. Zastosowanie nowych materiałów w konstrukcji takich czujników niesie za sobą duży potencjał. Celem rozprawy jest przedstawienie możliwości wykorzystania cienkowarstwowych struktur nanodiamentowych w niskokoherencyjnych czujnikach światłowodowych, które poprawią...
-
Quantum Coherence as a Resource
PublicationThe coherent superposition of states, in combination with the quantization of observables, represents one of the most fundamental features that mark the departure of quantum mechanics from the classical realm. Quantum coherence in many-body systems embodies the essence of entanglement and is an essential ingredient for a plethora of physical phenomena in quantum optics, quantum information, solid state physics, and nanoscale thermodynamics....
-
Swapping Space for Time: An Alternative to Time-Domain Interferometry
PublicationYoung's double-slit experiment [1] requires two waves produced simultaneously at two different points in space. In quantum mechanics the waves correspond to a single quantum object, even as complex as a big molecule. An interference is present as long as one cannot tell for sure which slit is chosen by the object. The more we know about the path, the worse the interference. In the paper we show that quantum mechanics allows for...
-
Structure of the Resource Theory of Quantum Coherence
PublicationQuantum coherence is an essential feature of quantum mechanics which is responsible for the departure between the classical and quantum world. The recently established resource theory of quantum coherence studies possible quantum technological applications of quantum coherence, and limitations that arise if one is lacking the ability to establish superpositions. An important open problem in this context is a simple characterization...
-
Towards Resource Theory of Coherence in Distributed Scenarios
PublicationThe search for a simple description of fundamental physical processes is an important part of quantum theory. One example for such an abstraction can be found in the distance lab paradigm: if two separated parties are connected via a classical channel, it is notoriously difficult to characterize all possible operations these parties can perform. This class of operations is widely known as local operations and classical communication....
-
Coda wave interferometry in monitoring the fracture process of concrete beams under bending test
PublicationEarly detection of damage is necessary for the safe and reliable use of civil engineering structures made of concrete. Recently, the identification of micro-cracks in concrete has become an area of growing interest, especially using wave-based techniques. In this paper, a non-destructive testing approach for the characterization of the fracture process was presented. Experimental tests were made on concrete beams subjected to mechanical...
-
Estimation of Coherence Bandwidth for Underwater Acoustic Communication Channel
PublicationA shallow underwater acoustic communication channel is characterized by strong multipath propagation. The signal reaching the receiver consists of a direct waveform and a number of its delayed and suppressed replica. A significant time dispersion of the transmitted signal and selective fading of its spectrum are observed. Coherence bandwidth defines maximal bandwidth, wherein the channel amplitude characteristic remains constant...
-
Applications of polarization interferometry in optical sensors
PublicationW artykule przedstawiono wybrane realizacje interferometrycznych czujników przesunięcia, wykonanych z elementów optyki objętościowej. Czujniki te, stosowane w technice pomiarowej i mikroskopii, charakteryzują się dużą rozdzielczością i dokładnością pomiaru. Omówiono problemy związane z implementacją tych czujników, wpływające na pogorszenie dokładności pomiaru. Zaprezentowano metody korekcji sygnału wyjściowego, opracowane dla...
-
Measurement of Coherence Bandwidth in UHF Radio Channels for Narrowband Networks
PublicationThis paper presents results of investigation on the coherence bandwidth of narrowband radio channels in 430MHz band. The coherence bandwidth values were estimated froma power delay profile obtained by recording CDMA2000 forward channel signals during real-fieldmeasurements in various environments:mediumcity, flat terrain, and hilly terrain in northern Poland.The results of measurements are compared with characteristic parameters...
-
Detection of petroleum products using optical coherence tomography
PublicationIn this work, we present a novel method developed for the analysis of the properties of thin layers for detecting petroleum products on a water surface using a commercially available optical coherence tomography (OCT) system. The spectral density analysis of the signal from a spectroscopic OCT (S-OCT) enables us to perform the precision calculation of the thin layer thickness and other properties like homogeneity, and dispersion,...
-
1D portable optical coherence tomography system
Publication—Imaging methods are an expanding branch of technology, which involves data acquisition and analysis of images for research and diagnostics. This paper has been devoted to the description of the optical design for a one-dimensional, portable optical coherence tomography (OCT) system. The Mach-Zehnder interferometer has been designed in the presented study. The description of the construction and applied hardware solutions have...
-
Detection system for optical coherence tomography: Czerny-Turner spectrometer
PublicationResearch methods based on spectral analysis have powerful impact on development in many field of science. Signal spectrum can be a source of useful and important data. It enables to obtain information about physical and chemical properties of tested materials. This paper has been devoted to describe optical design for high resolution spectrometer, which is significant element of optical coherence tomography (OCT) systems. Designed...
-
Laser reflectance interferometry system with a 405 nm laser diode for in-situ measurement of CVD diamond thickness
PublicationIn situ monitoring of the thickness of thin diamond films during technological processes is important because it allows better control of deposition time and deeper understanding of deposition kinetics. One of the widely used techniques is laser reflectance interferometry (LRI) which enables non-contact measurement during CVD deposition. The authors have built a novel LRI system with a 405 nm laser diode which achieves better...
-
Gold nanoparticles evaluation using functional optical coherence tomography
PublicationThe main object of this research was to assess the ability to characterize the gold nanoparticles using optical modalities like optical coherence tomography. Since the nanoparticles, especially gold one, have been very attractive for medical diagnosis and treatment the amount of research activities have been growing rapidly. The nanoparticles designed for different applications like contrast agents or drugs delivery change the...
-
Microcrystalline diamond film evaluation by spectroscopic optical coherence tomography
PublicationThis study has focused on the microcrystalline diamond film (MCD) thickness evaluation. For this purpose, optical coherence tomography (OCT) enhanced by spectroscopic analysis has been used as a method of choice. The average thickness of the tested layer was about 1.5 µm, which is below the standard 2-point OCT resolution. In this case, the usefulness of the spectroscopic analysis was confirmed for the evaluation of the thickness...
-
Efficient signal processing in spectroscopic optical coherence tomography
PublicationSpectroscopic optical coherence tomography (SOCT) is an extension of a standard OCT technique, which allows to obtain depth-resolved, spectroscopic information on the examined sample. It can be used as a source of additional contrast in OCT images e.g. by encoding certain features of the light spectrum into the hue of the image pixels. However, SOCT require computation of time-frequency distributions of each OCT A-scan, what is...
-
Nanoparticles displacement analysis using optical coherence tomography
PublicationOptical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits...
-
Parallel multithread computing for spectroscopic analysis in optical coherence tomography
PublicationSpectroscopic Optical Coherence Tomography (SOCT) is an extension of Optical Coherence Tomography (OCT). It allows gathering spectroscopic information from individual scattering points inside the sample. It is based on time-frequency analysis of interferometric signals. Such analysis requires calculating hundreds of Fourier transforms while performing a single A-scan. Additionally, further processing of acquired spectroscopic information...
-
Polarization-sensitive optical coherence tomography for ceramic materials inspection
PublicationCeramics production is looking for a fast, reliable and non-destructive method that can be implemented on site for defect detection and analysis. In this paper we present polarization-sensitive optical coherence tomography (PS-OCT) as a method for defect inspection. Proposed extensions to standard OCT provide additional information for complete characterization of tested object. We compare OCT and microscope imaging that can easily...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublicationThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Latent fingerprint imaging by spectroscopic optical coherence tomography
PublicationOptical coherence tomography (OCT) is a non-contact and non-invasive optical method for evaluating semitransparent and scattering objects. Its unique features, such as non-destructive 3D measurements of tested objects with a fast scanning rate, make this technique interesting for latent fingerprint reading, which is the subject of this paper. So far, OCT has not found widespread use for reading fingerprints directly from surfaces...
-
Measuring the density of DNA films using ultraviolet-visible interferometry
PublicationIn order to determine a proper value for the density of dry DNA films we have used a method based upon the measurement of interference effects in transmission spectra of thin DNA layers. Our results show that the methodology is effective and the density of DNA in this state, 1.407 g/cm3, is much lower than the commonly used 1.7 g/cm3. Obtaining accurate values for the DNA film density will allow the optical constants for DNA to...
-
Advanced Monte Carlo simulator of the polarization-sensitive optical coherence tomography systems
PublicationSimulations of the optical coherence tomography (OCT) systems using the Monte Carlo method is a widely explored research area. However, there are several difficulties that need to be overcome in order to properly model the OCT imaging with the Monte Carlo algorithm. First of all, the temporal and the spatial coherence of the scattered light need to be considered, since OCT is based on the interference phenomenon. For the same reason,...
-
Advanced polarization sensitive analysis in optical coherence tomography
PublicationThe optical coherence tomography (OCT) is an optical imaging method, which is widely applied in variety applications. This technology is used to cross-sectional or surface imaging with high resolution in non-contact and non-destructive way. OCT is very useful in medical applications like ophthalmology, dermatology or dentistry, as well as beyond biomedical fields like stress mapping in polymers or protective coatings defects detection....
-
Monitoring the fracture process of concrete during splitting using integrated ultrasonic coda wave interferometry, digital image correlation and X-ray micro-computed tomography
PublicationThe paper deals with the continuous-time monitoring of mechanical degradation in concrete cubes under splitting. A series of experiments performed with integrated coda wave interferometry (CWI) and digital image correlation (DIC), supported with X-ray micro-computed tomography (micro-CT) is reported. DIC and micro-CT techniques were used to characterize the fracture process in detail. CWI method was proved to be effective in the...
-
Study of probe signal bandwidth influence on estimation of coherence bandwidth for underwater acoustic communication channel
PublicationA signal transmitted in a shallow Underwater Acoustic Communication (UAC) channel suffers from time dispersion due to the multipath propagation and the refraction phenomena. This causes intersymbol interference of the received signal and frequency-selective fading observed in its spectrum. Coherence bandwidth is one of the key transmission parameters used for designing the physical layer of a data transmission system to minimise...
-
Novel approach to modeling spectral-domain optical coherence tomography with Monte Carlo method
PublicationNumerical modeling Optical Coherence Tomography (OCT) systems is needed for optical setup optimization, development of new signal processing methods and assessment of impact of different physical phenomena inside the sample on OCT signal. The Monte Carlo method has been often used for modeling Optical Coherence Tomography, as it is a well established tool for simulating light propagation in scattering media. However, in this method...
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublicationIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublicationThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
The mediational role of future and past time perspectives in the relationship between negative affectivity and sense of coherence
PublicationSense of coherence (SoC) can promote positive coping, and one of its most prominent negative correlates is negative affectivity (NA). In the current study, we hypothesized that future and past time perspectives (TPs) will mediate the relationship between sense of coherence and negative affectivity, and the inverse relationship. The study was questionnaire-based, performed online. N = 719 participants aged 25-45 from...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublicationThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Modeling of selected transducer designs for optical pressure sensors using polarization interferometry
PublicationW artykule przedstawiono wyniki modelowania metodą Elementów Skończonych wybranych konstrukcji membran do zastosowań w interferometrycznych czujnikach ciśnienia. Omówiono zależność prametrów membran od kształtu membrany, jej wymiarów i zastosowanego materiału. Zakres odkształcen badanych membran jest niezbyt duży, co może pogarszać dokładność pomiaru czujników ciśnienia, w których będą one stosowane Omówiono kierunki dalszych...
-
Time-frequency analysis in optical coherence tomography for technical objects examination
PublicationOptical coherence tomography (OCT) is one of the most advanced optical measurement techniques for complex structure visualization. The advantages of OCT have been used for surface and subsurface defect detection in composite materials, polymers, ceramics, non-metallic protective coatings, and many more. Our research activity has been focused on timefrequency spectroscopic analysis in OCT. It is based on time resolved spectral analysis...
-
Dispersion compensation in optical coherence tomography
PublicationDyspersja wprowadzana przez system optycznej tomografii koherentnej (OCT) oraz badane obiekty powoduje zniekształcenia fazowe w zależności od długości fali widma promieniowania zastosowanego źródła optycznego. powoduje to rozmycie obrazów otrzymanych przekrojów badanych materiałów pogarszając właściwości metrologiczne systemu OCT. W artykule przedstawiono metody kompensacji dyspersji w systemie OCT oraz przedyskutowano ich właściwości.
-
Polarization state analysis in optical coherence tomography
PublicationW artykule zaprezentowano metody analizy stanu polaryzacji światła w systemach optycznej tomografii kohererentnej. Przedstawiono różne konfiguracje systemu PS-OCT wraz z ich parametrami oraz właściwościami. Omówiono zasadę pomiaru stanu polaryzacji ściatła przy użyciu systemu PS-OCT oraz przeprowadzono dyskusję nad przydatnością metody do badania struktury materiałów silnie rozpraszających promieniowanie.
-
Polarization sensitive optical coherence tomography system
PublicationW pracy pokazano system OCT czuły na stan polaryzacji do pomiaru właściwości dwójłomnych wybranych ośrodków rozpraszających światło. W systemie zastosowano detekcję zrównoważoną. Pokazano wstępne wyniki pomiarowe.
-
Synthesized light source for optical coherence tomography
PublicationW artykule omówiono wpływ parametrów źródła promieniowania optycznego na właściwości systemu OCT. Szczególną uwagę zwrócono na źródła syntezowane. Omówiono charakterystykę źródła zbudowanego z dwóch różnych diod SLD. Przedstawiono wyniki pomiarów, które wskazują na możliwości znacznego polepszenia czułości i rozdzielczości systemu OCT wykorzystującego takie źródło.
-
Polarization sensitive optical coherence tomography with spectroscopic analysis
PublicationOptyczna tomografia koherentna (OCT) jest nieinwazyjną, nieniszczącą i bezkontaktową metodą obrazowania wewnętrznej struktury obiektów i materiałów rozpraszających. Dodatkowo w połączeniu z analizą stanu polaryzacji metoda ta umożliwia badanie lokalnych zmian optycznej anizotropii występującej w badanym obiekcie. W artykule przedstawiono zalety oraz ograniczenia metody oraz przedstawiono propozycję rozszerzenia analizy o badanie...
-
Landscape as the tool of coherence in the land management of rural communes
PublicationEconomic and social transformation of rural areas in Poland after 1990 reveals itself through disintegration of previous spatial order. Building a new pattern requires a vision, which would counteract complex causes of disintegration. The latter belong to institutional domain of planning strategies and the area of common practices. Therefore, agreement on aims and means between spatial policy strategies and tactics of space users...
-
Nano-particle doped hydroxyapatite material evaluation using Spectroscopic Polarization Sensitive Optical Coherence Tomography
PublicationBio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp....
-
Polarization sensitive optical coherence tomography for technical materials investigation
PublicationZaprezentowano system optycznej tomografii koherentnej z analizą stanu polaryzacji światła. System umożliwia nieniszczące i bezkontaktowe badanie wewnętrznej struktury materiałów warstwowych. Przedstawiono zastosowaną metodę analizy stanu polaryzacji promieniowana wstecznie rozproszonego od badanego obiektu.
-
Polarization sensitive optical coherence tomography for technical materials investigation
Publication -
<title>Synthesized light source for optical coherence tomograph</title>
Publication -
Application of sol-gel-developed integrated optic devices to biochemical fiber optic sensors based on polarimetric interferometry.
PublicationW pracy omówiono zasady działania sensorów optycznych wykonanych w technologii optyki zintegrowanej i wykorzystujących interferometrię polaryzacyjną. Zaproponowano konstrukcję jednorazowego przetwornika pomiarowego, wykonanego w technologii sol-żel z materiałów hybrydowych, która umożliwia wykorzystanie nieodwracalnych reakcji chemicznych do pomiarów w medycynie, chemii i ochronie środowiska. Omówiono technologię syntezy materiałów...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
LOW NOISE TIRES FOR HYBRID AND ELECTRIC VEHICLES
PublicationLow Emission Vehicles that are hybrid and electric cars may benefit from specially designed tires that are optimized for driving conditions typical for such vehicles. It is possible that in the future Low Emission Vehicles, especially passenger cars, will substitute conventional vehicles in all applications, however for the time being they are mostly used in urban and suburban areas. Urban traffic has a rather low demand for grip...
-
Multilayered structures examination using polarization sensitive optical coherence tomography
PublicationW artykule przedstawiono wstępne wyniki badań struktur warstwowych z użyciem systemu optycznej tomografii koherentnej z analizą stanu poaryzacji (PS-OCT). Omówiono budowę systemu oraz zakres stosowalności metody do badania złożonych struktur warstwowych.
-
Novel Low-Loss Substrates for 5G Applications
PublicationThis paper presents a feasibility study of a new type of microwave low-loss dielectric substrates for 5G network applications. The new substrate materials are composites of polypropylene and high-dielectric-constant micro-ceramics. This combination is expected to form a very low-loss dielectric material at low fabrication cost. Two substrate samples with different dielectric properties are fabricated and their characteristics at...
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublicationThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Evaluation of Low Temperature Properties of Rubberized Asphalt Mixtures
PublicationThe paper presents low-temperature test results of asphalt mixtures designed with use of bitumen modified by crumb rubber and also SBS polymer. Laboratory tests were conducted on two types of asphalt mixtures for wearing course – stone matrix asphalt (SMA 8) and porous asphalt (PA 8). This paper presents results of the following laboratory tests at low temperatures: TSRST test, three point bending creep test, fracture toughness...
-
Mild poikilocapnic hypoxia increases very low frequency haemoglobin oxygenation oscillations in prefrontal cortex
PublicationBackground: The aim of the study was to investigate the effect of mild cerebral hypoxia on haemoglobin oxygenation(HbO2), cerebrospinal fluid dynamics and cardiovascular physiology. To achieve this goal, four signals were recorded simultaneously: blood pressure, heart rate / electrocardiogram, HbO2 from right hemisphere and changes of subarachnoid space (SAS) width from left hemisphere. Signals were registered from 30 healthy,...
-
Low-Cost Surrogate Models for Microwave Filters
PublicationA novel low-cost kriging-based multivariable parametric macromodeling technique for microwave filters is presented. Kriging is used to model both the residues and poles of a microwave filter's reflection coefficient, and the zeros of the transmission coefficient. The proposed residue-pole-zero (RPZ) technique is demonstrated to efficiently model a high dimensional (8D) microwave filter with pseudoelliptic characteristics.
-
Low-energy interactions related to atmospheric and extreme conditions
PublicationThis Topical Issue, entitled “Low-Energy Interactions Related to Atmospheric and Extreme Conditions”, showcases a collection of eighteen articles that reported recent theoretical and experimental findings pertaining to the following topics: – low-energy interactions of charged particles (electrons [1–7], protons [8], positrons [9]), and photons [10] with atoms and molecules of biological [1–4,7,8], astrochemical [10], industrial,...
-
Multipulse inverter structures with low voltage distortion
PublicationA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse three-level...
-
Pedestrian detection in low-resolution thermal images
PublicationOver one million people die in car accidents worldwide each year. A solution that will be able to reduce situations in which pedestrian safety is at risk has been sought for a long time. One of the techniques for detecting pedestrians on the road is the use of artificial intelligence in connection with thermal imaging. The purpose of this work was to design a system to assist the safety of people and car intelligence with the use...
-
Assessment of Supercapacitor’s Quality by Means of Low Frequency Noise
PublicationLow frequency noise is a well-known tool for quality and reliability assessment of electronic devices. This phenomenon is observed in different electrochemical devices as well (e.g., smart windows, electrochemical corrosion processes). Thus, we can assume that the same tool can be used to asses quality of supercapacitors. Their quality is usually determined only by capacitance and/or equivalent series resistance (ESR), or impedance....
-
Corrosion of evaporator tubes in low emission steam boilers
PublicationPurpose of this paper is to reveal the mechanisms of corrosion processes of outer surfaces of low-emission steam boiler evaporator tubes. Examinations were performed to find the reasons of different corrosion susceptibility of tubes situated at combustion chamber on various levels. Examinations were conducted on several segments of 57 x 5.0 mm evaporator tubes made of 16M (16Mo3) steel grade. Segments were taken from level of...
-
Poroelastic Low Noise Road Surfaces
PublicationNoise is one of the most important problems related to road traffic. During the last decades, noise emitted by engine and powertrain of vehicles was greatly reduced and tyres became a clearly dominant noise source. The paper describes the concept of low noise poroelastic road surfaces that are composed with mineral and rubber aggregate bound by polyurethane resin. Those surfaces have a porous structure and are much more flexible...
-
Dedicated power supply subsystem for ultra-low noise preamplifiers
PublicationIn field of electronics there is need for low-noise amplifiers. Noise have the most important influence on analog circuits. Therefore exist necessity to develop new ultra-low noise power supplies, which can cooperate with specified amplifiers and preamplifiers. It is very common that professional power supplies are very expensive and still have disadvantages. This paper proposes simple and inexpensive solution, which fulfill specific...
-
Optical coherence tomography and magnetic resonance imaging visual pathway evaluation in Wolfram syndrome
Publication -
Low Power Baseband Processor for M2M Reconfigurable Radio Test Platform
PublicationSoftware Defined Radio (SDR) is becoming more andmore frequently used technique for wireless communication. Itfacilitates as fast prototyping and is a versatile method fordeveloping new communication systems. SDR can be realizedbased on high computational capacity platform, where powerconsumption is no a primary concern like i.e. DVB or BTStransmitters. Another trend are low power systems, whereavailable power in reduced and more...
-
On the use of a charge balancing method for low energy measurements
PublicationThe paper presents the method for the estimation of the energy consumption of the low-power microcontroller-based devices. Due to high dynamics of the changes of the supply current of the tested devices during the operational cycle, the consumed energy estimation is not easy. In order to avoid disadvantages of known methods, the charge balancing method was employed similarly like in some types of A/D converters.