Filters
total: 3926
filtered: 2595
-
Catalog
- Publications 2595 available results
- Journals 51 available results
- Conferences 7 available results
- People 40 available results
- Inventions 1 available results
- Projects 11 available results
- Research Teams 1 available results
- e-Learning Courses 26 available results
- Open Research Data 1194 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: SEMICONDUCTOR DEVICE MEASUREMENT
-
Operation of an ultra short fuse shunted by a semiconductor device: simulation and experiments.
PublicationW artykule przedstawiono ideę działania i wymagane cechy ultraszybkiego bezpiecznika w ograniczniku hybrydowym z równoległym elementem półprzewodnikowym. Eksperyment i modelowanie działanie bezpiecznika przeprowadzono dla spodziewanego prądu zwarciowego 2 kA. Symulacje wykonano przy użyciu programu polowego FLUX. Jego zastosowanie do modelowania ultrakrótkich bezpieczników zostało również przedstawione.
-
Device-independent quantum key distribution based on measurement inputs
PublicationWe provide an analysis of a family of device-independent quantum key distribution (QKD) protocols that has the following features. (a) The bits used for the secret key do not come from the results of the measurements on an entangled state but from the choices of settings. (b) Instead of a single security parameter (a violation of some Bell inequality) a set of them is used to estimate the level of trust in the secrecy of the key....
-
A Method of Lathe Checks Measurement; SMOF device and its software
Publication -
Low-power device simulator for micro-energy measurement methods testing
PublicationThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Experimental certification of an informationally complete quantum measurement in a device-independent protocol
PublicationMinimal informationally complete positive operator-valued measures (MIC-POVMs) are special kinds of measurement in quantum theory in which the statistics of their d2-outcomes are enough to reconstruct any d-dimensional quantum state. For this reason, MIC-POVMs are referred to as standard measurements for quantum information.Here, we report an experiment with entangled photon pairs that certifies, for what we believe is the first...
-
Automated measurement method for assessing thermal-dependent electronic characteristics of thin boron-doped diamond-graphene nanowall structures
PublicationThis paper investigates the electrical properties of boron-doped diamond-graphene (B:DG) nanostructures, focusing on their semiconductor characteristics. These nanostructures are synthesized on fused silica glass and Si wafer substrates to compare their behaviour on different surfaces. A specialized measurement system, incorporating Python-automated code, was developed for an in-depth analysis of electronic properties under various...
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublicationNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
A method of RTS noise identification in noise signals of semiconductor devices in the time domain
PublicationIn the paper a new method of Random Telegraph Signal (RTS) noise identification is presented. The method is based on a standardized histogram of instantaneous noise values and processing by Gram-Charlier series. To find a device generating RTS noise by the presented method one should count the number of significant coefficients of the Gram-Charlier series. This would allow to recognize the type of noise. There is always one (first)...
-
Horizontally-split-drain MAGFET - a highly sensitive magnetic field sensor
PublicationWe propose a novel magnetic field sensitive semiconductor device, viz., Horizontally-Split-Drain Magnetic-Field Sensitive Field-Effect Transistor (HSDMAGFET) which can be used to measure or detect steady or variable magnetic fields. Operating principle of the transistor is based on one of the galvanomagnetic phenomena and a Gradual Channel Detachment Effect (GCDE) and is very similar to that of Popovic and Baltes's SDMAGFET. The...
-
A current-controlled FET
PublicationA novel semiconductor device, viz., Horizontally-Split-Drain Current-Controlled Field-Effect Transistor (HSDCCFET) with two control electrodes is proposed in this works. For the sake of brevity, the device can be called a CCFET. Operating principle of the proposed transistor is based on one of the galvanomagnetic phenomena, the Biot-Savart-Laplace law and a Gradual Channel Detachment Effect (GCDE). The transistor is dedicated...
-
HARDWARE AND SOFTWARE OF DIAGNOSTIC SYSTEM OF WHEELED TRACTORS = Hardwer i softwer systemu diagnostycznego ciągników kołowych
PublicationPodstawowym elementem systemu diagnostycznego jest komputer pokładowy Fujitsu FUTURO S100 z chłodzeniem pasywnym w wykonaniu odpornym na drgania i wstrząsy, z pamięcią Compact Flesh 16Gb. Do komputera dołączony jest monitor dotykowy NVOX LCD 10" VGA/FVAT. Oprogramowanie komputera obejmujesystem operacyjny Windows XP-2000, driver konwertera USB/DeviceNet oraz opracowany program diagnostyczny. Komputer połączony jest łączem USB z...
-
A new nethod for RTS noise of semiconductor devices identification
PublicationIn the paper, a new method, called the noise scatterin pattern method (NSP method), for random telegraph signal noise identyfication in the inherent noise of semiconductor devices is described. A block diagram of a noise measurement system based on the NSP method is presented. Examples of patterns of the NSP method are presented.
-
Application of the Electronic Nose Technique to Differentiation between Model Mixtures with COPD Markers
PublicationABSTRACT The paper presents the potential of an electronic nose technique in the field of fast diagnostics of patients suspected of Chronic Obstructive Pulmonary Disease (COPD). The investigations were performed using a simple electronic nose prototype equipped with a set of six semiconductor sensors manufactured by FIGARO Co. They were aimed at verification of a possibility of differentiation between model reference mixtures with...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublicationW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
Gas sampling system for matrix of semiconductor gas sensors
PublicationSemiconductor gas sensors are popular commercial sensors applied in numerous gas detection systems. They are reliable, small, rugged and inexpensive. However, there are a few problem limiting the wider use of such sensors. Semiconductor gas sensor usually exhibits a low selectivity, low repeatability, drift of response, strong temperature and moisture influence on sensor properties. Sample flow rate is one of the parameters that...
-
Metody usuwania zakłóceń podczas pomiarów polowych widm Ramana
PublicationW pracy zostały scharakteryzowane źródła zakłóceń występujące podczas pomiarów widm Ramana w warunkach polowych oraz sposoby redukcji ich wpływu na jakość rejestrowanych widm. Zaprezentowano wpływ czasu integracji na jakość rejestrowanych widm w przypadkach, gdy szumy własne spektrometru mają składową typu 1/f, dominującą w zakresie małych częstotliwości. Przedstawiono także wyniki uzyskane podczas pomiarów z detekcją synchroniczną,...
-
Optoelectronic device for hematocrit measurements
PublicationAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Auto adaptation of mobile device characteristics to various acoustic conditions
PublicationThe proposed methodology of auto adaptation of the mobile device characteristics to various acoustic conditions is presented in the paper. The first goal of this study was to determine the parameters of the acoustic path of the mobile device, for both transmitting (speaker) and receiver (microphone). Results of the measurement of characteristics of mobile devices were presented. Information about characteristics of individual parts...
-
Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application
PublicationTechnical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...
-
Identification of inherent noise components of semiconductor devices on an example of optocouplers
PublicationIn the paper, a method of estimation of parameters of Gaussian and non-Gaussian components in the noise signal of semiconductor devices in a frequency domain is proposed. The method is based on composing estimators of two spectra, corresponding to noise (Gaussian component) and two-level RTS noise (non-Gaussian component). The proposed method can be applied for precise evaluation of the corner RTS frequency fRTS in the noise...
-
MEASUREMENT OF NOISE IN SUPERCAPACITORS
PublicationA developed method and measurement setup for measurement of noise generated in a supercapacitor is presented. The requirements for noise data recording are considered and correlated with working modes of supercapacitors. An example of results of low-frequency noise measurements in commercially available supercapacitors are presented. The ability of flicker noise measurements suggests that they can be used to assess quality of tested supercapacitors.
-
Noise in semiconductor devices
PublicationOmówiono typowe źródła szumów występujące w przyrządach pólprzewodnikowych, a mianowicie: cieplne, śrutowe, generacyjno-rekombinacyjne, 1/f, 1/f2, wybuchowe (RTS), lawinowe. Przedstawiono szumowe schematy zastępcze tranzystora bipolarnego, JFET i MOSFET oraz opisano wydajności poszczególnych źródeł szumów. Zasugerowano jak dobierać przyrządy półprzewodnikowe do małoszumowych układów w zakresie małych częstotliwości.
-
Device for spoofing in global positioning system
PublicationThis article describes the device which may be used to generate false GPS signals and emit them into radio communication channel. Such attack is called GPS spoofing. Each GPS receiver which remains in the range of a spoofing device (called spoofer) indicates time and position coordinates which are predetermined by the spoofer’s operator. Spoofing may be used e.g. in order to disable the terrorist group from obtaining correct navigation...
-
Single and Three -Phase PWM AC/AC Converters as Semiconductor Transformers
PublicationAC voltage transformation circuits contain pure or reactance PWM AC/AC converters. These circuits can be treated as AC/AC semiconductor transformers. This paper reviews single-phase and three-phase topologies: both non-isolated and isolated, single as well as two quadrant structure. Additionally, this paper present selected examples of their applications.
-
A Device for Measuring Auditory Brainstem Responses to Audio
PublicationStandard ABR devices use clicks and tone bursts to assess subjects’ hearing in an objective way. A new device was developed that extends the functionality of a standard ABR audiometer by collecting and analyzing auditory brainstem responses (ABR). The developed accessory allows for the use of complex sounds (e.g., speech or music excerpts) as stimuli. Therefore, it is possible to find out how efficiently different types of sounds...
-
STRUCTURE AND ALGORITHMS OF A DIAGNOSTIC DEVICE IN A WHEELED TRACTOR
PublicationDiagnostic device monitors the tractor’s technical condition and identifies the location of damaged components during operation. The diagnostic device detects and identifies the following types of defects: functional defects (uf) which affect performance, exhaust defects (ue) which increase toxic emissions and fuel consumption, defects that jeopardize driving safety (us), defects that affect engine performance (ud). The key component...
-
Investigation of the temperature modulation parameters on semiconductor gas sensor response
PublicationIn this work we present the results of the investigation of the sensing properties of semiconductor gas sensors with a sinusoidally modulated temperature in the presence of synthetic air (SA) and three volatile air pollutants, i.e. NH3, NO2 and SO2. The measurements were performed for different average sensor heater temperatures and the amplitude of the modulation signal. In addition, the extraction of features from the sensor...
-
The novel sterilization device: the prototype testing
PublicationCurrently, there are numerous methods that can be used to neutralize pathogens (i.e., devices, tools, or protective clothing), but the sterilizing agent must be selected so that it does not damage or change the properties of the material to which it is applied. Dry sterilization with hydrogen peroxide gas (VHP) in combination with UV-C radiation is well described and effective method of sterilization. This paper presents the design,...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublicationA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
A Novel Device and System for Fall Detection Under the Shower
PublicationIn this paper, device construction and preliminary results for shower safety assistance are presented. The device allows monitoring of shower-taking persons without violating privacy and intimacy, while it has the ability to detect a persons entering and leaving the shower and detecting fall conditions. It allows better supervision of elders living independently at their locations.
-
Combined environmental testing device for picosatellites
PublicationAs access to space conditions becomes more available, both technically and economically, scientists’ interest in launching finer and more sophisticated experiments grows. To be qualified for launch, such experiments need to be carefully tested prior to the event. The tests should represent actual launch conditions as closely and in a detailed manner. Typical tests for payload include: vibration tests, thermal and vacuum tests,...
-
A New Rehabilitation Device for Balance Impaired Individuals
PublicationIn the paper authors present a device designed to improve the rehabilitation process of people with balance impairment. The discussed device (JStep) utilizes a commercially available static standing frame (stander) modified in order to fit force sensing units under the feet and in the pillows around the hips of a patient. While executing rehabilitation tasks, the patient may compensate his balance deficiency by leaning on the pillows...
-
Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
PublicationA periodic temperature modulation using sinusoidal heater voltage was applied to a commercial SnO2 semiconductor gas sensor. Resulting resistance response of the sensor was analyzed using a feature extraction method based on Fast Fourier Transformation (FFT). The amplitudes of the higher harmonics of the FFT from the dynamic nonlinear responses of measured gas were further utilized as an input for Artificial Neural...
-
Low-frequency noise in ZrS3 van der Waals semiconductor nanoribbons
PublicationWe report the results of the investigation of low-frequency electronic noise in ZrS3 van der Waals semiconductor nanoribbons. The test structures were of the back-gated field-effect-transistor type with a normally off n-channel and an on-to-off ratio of up to four orders of magnitude. The current–voltage transfer characteristics revealed significant hysteresis owing to the presence of deep levels. The noise in ZrS3 nanoribbons...
-
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublicationAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Relationship between semi- and fully-device-independent protocols
PublicationWe study the relation between semi and fully device independent protocols. As a tool, we use the correspondence between Bell inequalities and dimension witnesses. We present a method for converting the former into the latter and vice versa. This relation provides us with interesting results for both scenarios. First, we find new random number generation protocols with higher bit rates for both the semi and fully device independent...
-
Thermomagnetic behavior of a semiconductor material heated by pulsed excitation based on the fourth-order MGT photothermal model
PublicationThis article proposes a photothermal model to reveal the thermo-magneto-mechanical properties of semiconductor materials, including coupled diffusion equations for thermal conductivity, elasticity, and excess carrier density. The proposed model is developed to account for the optical heating that occurs through the semiconductor medium. The Moore–Gibson–Thompson (MGT) equation of the fourth-order serves as the theoretical framework...
-
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublicationA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Validation of atmospheric aerosols parallel sampling in a multifold device
PublicationIn this work, particulate matter was collected using an active sampling system consisting of a PM10 (<10 μm) inlet coupled to a multifold device containing six channels, connected to a vacuum pump. Each channel was equipped with a filter holder fitted with adequately chosen filters. The system was fixed on a metallic structure, which was placed on the roof of the laboratory building, at the Faculty of Sciences, in Lisbon. Sampling...
-
Fluctuation phenomena in semiconductor gas sensors
PublicationCzujniki gazu mogą być wytwarzane z cienkiej warstwy półprzewodnika, która po podgrzaniu do odpowiedniej temperatury staje się czuła na gaz. Zjawisko to jest dobrze znane i szeroko opisane w literaturze. Jako wskaźnik detekcji gazu wykorzystuje się zmianę rezystancji stałoprądowej czujnika. Zwiększenie czułości i, co najważniejsze z praktycznego punktu widzenia, selektywności dyskryminacji można uzyskać jeśli warstwa półprzewodnika...
-
On the selectivity of nanostructured semiconductor gas sensors
Publication.
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the pumping effect of air in the electrohydrodynamic (EHD) device for dust particle collection is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. The asymmetric electric field and generated discharge resulted in a unidirectional airflow through the EHD device. The current-voltage characteristics...
-
Particle Image Velocimetry Measurements of Airflow in Electrohydrodynamic Device for Dust Particle Collection
PublicationIn this paper the electrohydrodynamic (EHD)device for gas pumping and cleaning is presented. To induce an airflow in this EHD device corona discharge was used. The discharge was generated between the one-sided spike electrodes and the plate electrodes. An asymmetric electric field and generated discharge result in unidirectional gas flow through the EHD device. The current-voltage characteristics were measured and the corona discharge...
-
Long-Term Measurement of Physiological Parameters – Child Dataset
PublicationThe dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...
-
Design and material selection for a patient transport device in field hospitals
PublicationACKGROUND: A major cause of patient and hospital worker injuries occurs transferring patients between two planes. The main aim of this paper was to propose a design of patient’s lift and transfer apparatus for use in field hospitals. The assumption was to design lightweight, durable and ergonomic device using innovative material. The authors concentrated on partial elimination of manual lifting in order to device could work both...
-
Design of a continuous intra-oral distraction device for mandibular bone
PublicationIn this paper we present example of a specific device used for distraction osteogenesis. Distraction osteogenesis (also called callus distraction, collotasis or osteodistraction) is a surgical process for reconstructing bone deformities or lengthening bones.
-
Compressible gas density measurement by means of Fourier analysis of interferograms
PublicationThis paper describes a method for nonintrusive compressible gas density measurement by means of automated analysis of interferograms using FFT (Fast Fourier Transform), and its implementation using DFT (Discrete Fourier Transform), that does make this measurement technique a fairly valuable and accessible experimental method. The presented approach makes it possible to use the finite fringe setting of the interferometer, thus reducing...
-
The evaluation of the vibration measurement usability of electronic indicator lemag "premet C"
PublicationThe measuring possibilities of modern compression and combustion pressure analyzers are extended with additional functions. One of them is parallel to the pressure measurement, the measurement of vibrations in the region of the cylinder head. The paper presents a general assessment of the vibration measurement function of the electronic indicator LEMAG "PREMET C". This feature is very rarely offered by manufacturers of these devices....