Filters
total: 1489
-
Catalog
- Publications 1145 available results
- Journals 28 available results
- Conferences 14 available results
- People 33 available results
- Projects 14 available results
- Research Teams 2 available results
- Research Equipment 9 available results
- e-Learning Courses 27 available results
- Events 1 available results
- Open Research Data 216 available results
displaying 1000 best results Help
Search results for: dc micro grid
-
Application of commercial supercapacitor modules in autonomic photovoltaic installations
PublicationDynamiczny rozwój technologii i konstrukcji superkondensatorów, napędzany głównie potrzebami przemysłu motoryzacyjnego pozwala na stwierdzenie, że stają się one coraz bardziej realną alternatywą dla konwencjonalnych akumulatorów stosowanych w autonomicznych instalacjach fotowoltaicznych.Za ich stosowaniem przemawiają takie zalety jak: możliwość szybkiego ładowania i rozładowania, wielokrotnie wyższa trwałość, bezobsługowość eksploatacji...
-
Scrutiny of power grids by penetrating PV energy in wind farms: a case study of the wind corridor of Jhampir, Pakistan
PublicationThis study examines the problems caused by intermittent renewable energy sources, especially wind farms, and suggests a different solar energy penetration strategy to improve their loading capacity. The study uses real-time data from a wind farm in Jhampir, Pakistan, to analyse and assess various aspects of grid stations connected to wind farms. Electrical Transient Analyzer Program is used to validate the results by linking...
-
Solving Boundary Value Problems for Second Order Singularly Perturbed Delay Differential Equations by ε-Approximate Fixed-Point Method
PublicationIn this paper, the boundary value problem for second order singularly perturbed delay differential equation is reduced to a fixed-point problem v = Av with a properly chosen (generally nonlinear) operator A. The unknown fixed-point v is approximated by cubic spline vh defined by its values vi = vh(ti) at grid points ti, i = 0, 1, ... ,N. The necessary for construction the cubic spline and missing the first derivatives at the boundary...
-
Scrutiny of power grids by penetrating PV energy in wind farms: a case study of the wind corridor of Jhampir, Pakistan
PublicationThis study examines the problems caused by intermittent renewable energy sources, especially wind farms, and suggests a different solar energy penetration strategy to improve their loading capacity. The study uses real-time data from a wind farm in Jhampir, Pakistan, to analyse and assess various aspects of grid stations connected to wind farms. Electrical Transient Analyzer Program is used to validate the results by linking these...
-
Long-term hindcast simulation of sea ice in the Baltic Sea
Open Research DataThe data set contains the results of numerical modeling of sea ice over a period of 50 years (1958-2007) in the Baltic Sea. A long-term hindcast simulation was performed using a three-dimensional hydrodynamic model PM3D (Kowalewski and Kowalewska-Kalkowska, 2017), a new version of the M3D model (Kowalewski, 1997). A numerical dynamic-thermodynamic model...
-
Hydrodynamic reanalysis of ice conditions in the Baltic Sea using the PM3D model
Open Research DataThe dataset contains the results of numerical modeling of sea ice in the Baltic Sea since 1998. A long-term reanalysis was performed using the three-dimensional hydrodynamic model PM3D (Kowalewski and Kowalewska-Kalkowska, 2017), a new version of the M3D model (Kowalewski, 1997). A numerical dynamic-thermodynamic model of sea ice (Herman et al. 2011)...
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublicationThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Crowdsourcing and Volunteer Computing as Distributed Approach for Problem Solving
PublicationIn this paper, a combination between volunteer computing and crowdsourcing is presented. Two paradigms of the web computing are described, analyzed and compared in detail: grid computing and volunteer computing. Characteristics of BOINC and its contribution to global Internet processing are shown with the stress put onto applications the system can facilitate and problems it can solve. An alternative instance of a grid computing...
-
Dynamic characteristics of the proton exchange membrane fuel cell module
PublicationThe paper describes a fuel cell based system and its performance. The system is based on two fuel cell units, DC/DC converter, DC/AC inverter, microprocessor control unit, load unit, bottled hydrogen supply system and a set of measurement instruments. In the study presented in the paper a dynamic response of the proton exchange membrane (PEM) fuel cell system to unit step change load as well as to periodical load changing cycles...
-
Spectroscopic and magnetic studies of highly dispersible superparamagnetic silica coated magnetite nanoparticles
PublicationSuperparamagnetic behavior in aqueously well dispersible magnetite core-shell Fe3O4@SiO2 nanoparticles is presented. The magnetic properties of core-shell nanoparticles were measured with use of the DC, AC magnetometry and EPR spectroscopy. Particles were characterized by HR-TEM and Raman spectroscopy, showing a crystalline magnetic core of 11.5 ± 0.12 nm and an amorphous silica shell of 22 ± 1.5 nm in thickness. The DC, AC magnetic...
-
Wpływ konfiguracji elektrod pomiarowych oraz parametrów pomiaru na EDR
PublicationW pracy przebadano wplyw wybranych konfiguracji elektrod na jakość uzyskiwanego sygnału EDR. Analizie poddane zostały również częstotliwość próbkowania sygnału EKG i rozdzielczość przetwornika AC/DC. Optymalną konfiguracją elektrod jest odprowadzenie kończynowe pierwsze. Minimalne parametry układu pomiarowego do uzyskania wysokiej jakości sygnału EDR, to częstotliwość probkowania 2,5kHz oraz 14-bitowy przetwornik AC-DC.
-
SIMULATIONS OF FRACTURE IN CONCRETE BEAMS UNDER BENDING USING A CONTINUUM AND DISCRETE APPROACH
PublicationThe paper describes two-dimensional meso-scale results of fracture in notched concrete beams under bending. Concrete was modelled as a random heterogeneous 4-phase material composed of aggregate particles, cement matrix, interfacial transitional zones and air voids. Within continuum mechanics, the simulations were carried out with the finite element method based on a isotropic damage constitutive model enhanced by a characteristic...
-
Examples of numerical simulations of two-dimensional unsaturated flow with VS2DI code using different interblock conductivity averaging schemes
PublicationFlow in unsaturated porous media is commonly described by the Richards equation. This equation is strongly nonlinear due to interrelationships between water pressure head (negative in unsaturated conditions), water content and hydraulic conductivity. The accuracy of numerical solution of the Richards equation often depends on the method used to estimate average hydraulic conductivity between neighboring nodes or cells of the numerical...
-
Conjugated control of triple active bridge converter with common HFT
PublicationPaper presents synthetic analyses of single input, dual output DC/AC/DC converter with common high frequency transformer. Rise the problem of cross-coupling power flows between secondary terminals, under asymmetrical control operating condition. It also proposes a new approach to converter control, based on conjugated phase shift modulation and defines its limitations. Finally, the developed control technique was verified by simulation...
-
Hybridized PWM Strategy for Three- and Multiphase Three-Level NPC Inverters
PublicationA simple hybridized pulsewidth modulation (PWM) algorithm for three- and multiphase three-level neutral point clamped (NPC) inverters is proposed. The proposed solution is based on classical space vector PWM (SVPWM) algorithms for two-level inverters but can also be based on sinusoidal PWM with min–max injection. An additional level of output voltage is obtained by modifying the resulting switching patterns taking into account...
-
A New Three-Dimensional Space Vector Modulation for Multilevel Four-Leg Converters Based on the Shape Functions of Tetrahedral Element
PublicationThe paper proposes a new three-dimensional space vector pulse-width modulation (3D-SVPWM) algorithm for multilevel four-leg converters. The proposed PWM duty cycle calculation is based on the shape functions of the threedimensional tetrahedral finite elements. The algorithm ensures synthesis of accurate and undistorted output voltages even under significant imbalance or ripple in the DC-link voltages. At the same time, the algorithm...
-
Superconductivity and itinerant ferromagnetism of Y9Co7 probed by ac susceptibility
PublicationThe ac magnetic susceptibility of a single crystal sample of the compound Y9Co7 has been measured in applied dc fields ranging from 0–6.7 kOe by utilizing a tunnel diode resonator circuit. In agreement with previous measurements on this material, a superconducting transition has been observed to occur at TSC ≈ 2.5 K. A broad maximum has been observed in the zero field susceptibility measurements from 2.5 K < T < 8 K and its behavior...
-
Direct shear stress vs strain relation for fiber reinforced composites
PublicationThe majority of fiber reinforced composites exhibit strong non-linear behavior in in-plane shear state. The effect is attributed to the micro-cracks appearing in the matrix and can be modeled on the micro and macro level. In this work the author proposes constitutive laws describing the non-linear in-plane shear response, which can be alternative for the relations commonly considered in the literature. The proposed equations are...
-
Big Data Processing by Volunteer Computing Supported by Intelligent Agents
PublicationIn this paper, volunteer computing systems have been proposed for big data processing. Moreover, intelligent agents have been developed to efficiency improvement of a grid middleware layer. In consequence, an intelligent volunteer grid has been equipped with agents that belong to five sets. The first one consists of some user tasks. Furthermore, two kinds of semi-intelligent tasks have been introduced to implement a middleware...
-
Komputerowe szacowanie zaburzeń elektromagnetycznych
PublicationPrzedstawiono symulacyjne badania porównawcze w zakresie kompatybilności elektromagnetycznej EMC modelu obwodowego przetwornicy DC-DC podwyższającej napięcie. Zbadano wrażliwość uzyskanego modelu na kolejne uproszczenia jego postaci, w ten sposób otrzymując zredukowany, równoważny model do oszacowania charakterystyki widma zaburzeń EMI na sieci sztucznej. Taki model zrealizowano w symulatorze TCad i porównano zgodność wyników symulacji...
-
Hysteresis modelling of a medium frequency single-phase transformer
PublicationThe article describes a feedback Preisach hysteresis model equivalent circuit implementation of a medium frequency single-phase transformer being a part of a high power and high efficiency DC-DC converter. The macroscopic models of magnetic hysteresis are introduced and the feedback Preisach model is selected for further analysis. The hysteresis model is developed for a prototype transformer and the hysteresis loops are compared...
-
Optimisation of cooperation of hybrid renewable energy sources with hydrogen energy storage toward the lowest net present cost
PublicationThe paper presents the results of a technical and economic analysis of the power supply for a model industrial facility based on intermittent renewable energy sources in the form of wind turbines and photovoltaic modules, supplemented with hydrogen energy storage. The adopted power supply strategy assumed the maximisation of self-consumption of self-produced electricity. Six variants were considered, including two with an energy...
-
FDTD Simulations on Disjoint Domains with the Use of Discrete Green's Function Diakoptics
PublicationA discrete Green's function (DGF) approach to couple disjoint domains in the finite-difference time-domain (FDTD) grid is developed. In this method, total-field/scattered-field (TFSF) FDTD domains are associated with simulated objects whereas the interaction between them is modeled with the use of the DGF propagator. Hence, source and scatterer are simulated in separate domains and updating of vacuum cells, being of little interest,...
-
Electrical conductivity of the Sr0.86Ti0.65Fe0.35O3-d pellet at different oxygen partial pressures
Open Research DataThis dataset contains results electrical conductivity measurements of dense Sr0.86Ti0.65Fe0.35O3-d (STF35) pellet. DC electrical conductivity measurements of STF35 were performed by the Van der Pauw method. Studies were performed at different oxygen partial pressures (20%, 1% and 0.1%) under humidified (~4 vol%) gas flow rate of 50 ml min -1.
-
A commercial gas boiler fitted with the ORC module as perspective solution for households
PublicationIn this paper the applicability of the commercial gas boiler (De Dietrich DTG X23N) coupled with the laboratory prototype micro ORC setup was experimentally studied. The main objective was to determine the working fluid capability to obtain required temperatures of vapour prior to the turbine, attainable heat rates and efficiencies of the whole system. The boiler thermal power was 25 kW. Tests were carried out with a single stage...
-
Femtosecond laser ablated trench array for improving performance of commercial solid oxide cell
PublicationThe performance of electrode-supported solid oxide cells (SOCs) is limited adversely by gas diffusion impedance in thick and porous support. This work focuses on the improvement of gas transport properties of commercial Ni-YSZ anode-supported SOFC by femtosecond laser-based micromachining where micro-holes of identical depth but different hole separations pitches with minimal heated affected zones were imposed. The polarization...
-
Application of optical microsphere in fiber optic sensors for measurement of electrochemical processes
Open Research Datainvestigation of the electrochemical processes using micro-sphere fiber-optic sensor with a zinc oxide (ZnO) coating applied by Atomic Layer Deposition method (ALD). The measurements were performed in 1M KNO3 during a decomposition of Bisphenol-A
-
UAV Survey Images - 3D Model - Jastrzebia Gora Cliff 07.2017- MP1
Open Research DataDataset description: Raw images from photogrammetric survey. Object: Cliff in Jastrzebioa GoraLocation: Jastrzebia Gora, Pomerania, PolandDrone type: DJI Mavic Pro 1Flight plan: Single Grid/Free FlightTarget Product: 3D ModelDate: 06.07.2017Direct georeferencing: yesMetadata data: yes/GPSGCP: NOGCP Quality: N/ACamera Name: DJI FC220Model type: PerspectiveImage...
-
UAV Survey Images - 3D Model - Jastrzebia Gora Cliff 11.2017- MP1
Open Research DataDataset description: Raw images from photogrammetric survey. Object: Cliff in Jastrzebioa GoraLocation: Jastrzebia Gora, Pomerania, PolandDrone type: DJI Mavic Pro 1Flight plan: Single Grid/Free FlightTarget Product: 3D ModelDate: 05.11.2017Direct georeferencing: yesMetadata data: yes/GPSGCP: NOGCP Quality: N/ACamera Name: DJI FC220Model type: PerspectiveImage...
-
Mohammad Hossein Ghaemi dr inż.
PeopleMohammad Hossein Ghaemi Mohammad Hossein Ghaemi (1967), is an Assistant Professor at the Faculty of Mechanical Engineering and Ship Technology - WIMiO (till 2020: Faculty of Ocean Engineering and Ship Technology), Department of Automatics and Marine Energy Engineering. He studied first at Tehran University, where was graduated in the field of Mechanical Engineering (Solid Mechanics). Then he received his MSc degree in the area...
-
Różne subpopulacje komórek dendrytycznych oraz sposoby regulowania ich aktywności
PublicationOpisano komórki dendrytyczne (DC), stanowiące złożoną, heterogenną populację leukocytów wywierającą różnorodny efekt na funkcjonowanie systemu odpornościowego.
-
Building a Nest by an Automaton
PublicationA robot modeled as a deterministic finite automaton has to build a structure from material available to it. The robot navigates in the infinite oriented grid $Z x Z$. Some cells of the grid are full (contain a brick) and others are empty. The subgraph of the grid induced by full cells, called the {\em field}, is initially connected. The (Manhattan) distance between the farthest cells of the field is called its {\em span}. The robot...
-
XLS file with the initial data on the dome's geometry outline
Open Research DataThis dataset consists of an XLS file with the initial data on the dome's geometry outline.
-
Autodesk AUTOCAD file with the dome's geometry outline
Open Research DataThis dataset consists of an Autodesk AUTOCAD file with the dome's geometry outline.The studies carried out in the "Miniatura 7" scientific grant were devoted to both experimental and theoretical (numerical) measurements executed on a tensegrity dome model (with a Fuller-type grid) to identify the changes in the state of displacements, induced by the...
-
Impedance Studies of Phosphate-iron Glasses Containing Niobium and Titanium
PublicationThe ac and dc conductivity in phosphate-iron-niobate glasses with addition of titanium oxide was investigated as a function of temperature and frequency with the use of impedance spectroscopy. The topography and microstructure of glasses were investigated by the means of X-ray diffraction (XRD), scanning electron microscopy (SEM), and confocal microscopy methods. The obtained results show that all samples are amorphous but they...
-
Assessment of copper surface coverage with corrosion inhibitor using AFM-based local electrical measurements
PublicationThe paper presents a new method of assessment of metal surface coverage with corrosion inhibitor and thus of inhibitor protective performance. It is based on the atomic force microscopy measurement performed in a contact mode. Apart from topography images the proposed approach allows acquisition of local DC maps and local electrical impedance spectra via application of DC bias voltage or AC perturbation signal between the conductive...
-
Electrical conductivity of the SrTi1-xFexO3-d pellets at 20% pO2
Open Research DataThis dataset contains results electrical conductivity measurements of dense SrTi1-xFexO3-d (x=0.35, 0.50, 0.70) pellets. DC electrical conductivity measurements were performed by the Van der Pauw method between 900 °C and 200 °C. Studies were performed at 20% of oxygen partial pressure under humidified (~4 vol%) gas flow rate of 50 ml min -1.
-
Low temperature electrical conductivity of the SrFeO3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrFeO3-d (SFO) pellet. DC electrical conductivity measurements of SFO were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas flow rate of 40...
-
Low temperature electrical conductivity of the SrTi0.65Fe0.35O3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.65Fe0.35O3-d (STF35) pellet. DC electrical conductivity measurements of STF35 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.30Fe0.70O3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.30Fe0.70O3-d (STF70) pellet. DC electrical conductivity measurements of STF70 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.50Fe0.50O3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.50Fe0.50O3-d (STF50) pellet. DC electrical conductivity measurements of STF50 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Low temperature electrical conductivity of the SrTi0.10Fe0.90O3-d pellet
Open Research DataThis dataset contains results of low temperature electrical conductivity measurements of dense SrTi0.10Fe0.90O3-d (STF90) pellet. DC electrical conductivity measurements of STF90 were performed by the Van der Pauw method between 400 °C and room temperature with 20 °C step. Studies were performed at Synthetic Air flow under humidified (~4 vol%) gas...
-
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
PublicationZnanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy....
-
Infrastruktura elektroenergetyczna dla transportu elektromobilnego
PublicationW pracy przedstawiono rozwiązania Smart Grid w miejskiej trakcji elektrycznej. W szczególności zwrócono uwagę na infrastrukturę tramwajową i trolejbusową do ładowania autobusów elektrycznych.
-
Harmony Search for Self-configuration of Fault–Tolerant and Intelligent Grids
PublicationIn this paper, harmony search algorithms have been proposed to self-configuration of fault-tolerant grids for big data processing. Self-configuration of computer grids lies in the fact that new computer nodes are automatically configured by software agents and then integrated into the grid. A base node works due to several configuration parameters that define some aspects of data communications and energy power consumption. We...
-
Integration of cloud-based services into distributed workflow systems: challenges and solutions
PublicationThe paper introduces the challenges in modern workflow management in distributed environments spanning multiplecluster, grid and cloud systems. Recent developments in cloud computing infrastructures are presented and are referring howclouds can be incorporated into distributed workflow management, aside from local and grid systems considered so far. Severalchallenges concerning workflow definition, optimisation and execution are...
-
Modified SPWM Technique with Zero-Sequence Voltage Injection for a Five-Phase, Three-Level NPC Inverter
PublicationThis article presents a modified sinusoidal pulse-width modulation (SPWM) scheme for a five-phase, three-level neutral-point-clamped inverter. The modulation scheme deploys a modified min–max function to inject the zero-sequence components into the reference modulating signals; hence enabling the effective utilization of the DC-link voltage. Balanced split-input DC-link voltages were achieved through further incorporation of adjustable...
-
Microstructure and Dielectric Properties of Barium-vanadate Glasses
PublicationThe ac and dc conductivity in barium-vanadate glasses was investigated as a function of temperature and frequency with the use of impedance spectroscopy. The topography and microstructure of glasses were investigated by the means of X-ray diffraction (XRD) and scanning electron microscopy (SEM) methods. The XRD results show that all samples are amorphous but microscopy investigation reveals that glasses with greater amount of V2O5...
-
Decentralized control of a different rated parallel UPS systems
PublicationThe paper presents the single phase uninterruptible power supply (UPS) system with galvanic separated DC-AC-DC-AC converters operating in parallel. The CAN physical layer based system of communication between converters has been developed and applied, which allow to utilize a decentralized master-slave control providing high availability factor of the whole UPS system. The control system of particular converters has been developed...
-
Power electronic transformer based on cascaded H-bridge converter
PublicationIn this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...