Filters
total: 4915
-
Catalog
- Publications 3600 available results
- Journals 71 available results
- People 93 available results
- Inventions 1 available results
- Projects 4 available results
- Laboratories 1 available results
- Research Equipment 1 available results
- e-Learning Courses 90 available results
- Events 2 available results
- Open Research Data 1052 available results
displaying 1000 best results Help
Search results for: LABORATORY REFERENCE MATERIAL
-
Rain Gardens LC_MS/MS analysis dataset
Open Research DataThis dataset contains the results of samples analysis (target analysis with certified reference materials) using ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS, Shimadzu, Japan).
-
Blurred quantum Darwinism across quantum reference frames
PublicationQuantum Darwinism describes objectivity of quantum systems via their correlations with their environment--information that hypothetical observers can recover by measuring the environments. However, observations are done with respect to a frame of reference. Here, we take the formalism of [Giacomini, Castro-Ruiz, & Brukner. Nat Commun 10, 494 (2019)], and consider the repercussions on objectivity when changing quantum reference...
-
On Dynamic Extension of a Local Material Symmetry Group for Micropolar Media
PublicationFor micropolar media we present a new definition of the local material symmetry group considering invariant properties of the both kinetic energy and strain energy density under changes of a reference placement. Unlike simple (Cauchy) materials, micropolar media can be characterized through two kinematically independent fields, that are translation vector and orthogonal microrotation tensor. In other words, in micropolar continua...
-
Electric Machines Virtual Laboratory
e-Learning CoursesThis is an educational aid for students. It shows the environment of industrial application of electric machines and allows for a look inside them. Users can see the main components of the power system in its natural environment. This course is to allow access to the VR app – Electric Machines Virtual Laboratory.
-
Image projection in Immersive 3D Visualization Laboratory
PublicationIn recent years, many centers in the world attempted to build a virtual reality laboratory. The main idea of such laboratory is to allow the user to “immerse” into and move in a computer-generated virtual world. In the paper, the underlying principles of the system of virtual reality (VR) are described. The selected implementations constructed by the research centers of the world are also presented. The cave automatic virtual environment...
-
Chemical and structural studies of screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Open Research DataThis dataset contains chemical analyses and structural studies by XPS and Raman spectroscopy, carried out for SPCE containing boron-doped diamond BDD foils done with scanning electron microscope. Different points for XPS analysis mark different electrode spots: A) working electrode, B) reference electrode, C) counter electrode, D) pads.
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Comparison of road and laboratory measurements of tyre/road noise
PublicationTyre/road noise is one of the major environmental problems related to road traffic. There are several measuring methods of tyre/road noise that may be carried out on the road (for example Coast-down and Close Proximity Method) or in the laboratory (Drum Method). Road measurements are preferred for evaluations of pavement properties while laboratory methods are mostly used to evaluate tyres. One of the biggest problems associated...
-
Cold recycled mixtures for binder courses - laboratory evaluation of mechanical properties
PublicationCold recycled mixtures composed with cement and bituminous emulsion are nowadays commonly used material for base layer. Typical pavement with cold recycled mixtures usually consists of two asphalt courses (wearing and binding course) constructed over cold recycled base. Therefore the next step in cold recycling is possibility of design of binding courses with recycled materials, but with potential to obtain high quality mixtures...
-
DWDM Network Laboratory Solution for Telecommunication Education Engineering
PublicationDevelopment of network architectures in the field of optical telecommunications technologies is an indicator of changes in telecommunication education engineering. Conducting didactic classes requires hardware infrastructure and research in terms of teaching needs. In the paper we present DWDM network laboratory solution for telecommunication education engineering on the basis of the ADVA Optical Networking equipment. We have to...
-
Experimentation, material modelling and simulation of bonded joints with a flexible adhesive
PublicationThe paper deals with material parameters identification of a flexible adhesive and the numerical simulation of its behaviour in a single lap bonded joint. The material modelling was based on the simple shear and tensile-shear laboratory tests of the bonded joints made of thin aluminium and polyurethane plates with the flexible adhesive Terostat MS 9360 manufactured by Henkel AG & Co. The adhesive was considered as a hyperelastic...
-
The effect of tire aging on acoustic performance of CPX reference tires
PublicationReduction of tire/road noise is one of the biggest environmental challenges of road traffic. To reduce that noise it is necessary to perform acoustic measurements on the base of wellproven standard procedures. One method of measurements that is in common use, namely the Close Proximity Method (CPX), is described in standard ISO-DIS 11819-2. As this method is used to classify road surfaces regarding their influence on vehicle noise,...
-
Configuration of the reference stations as the element of national reference frame reliability
Publication -
Impedance spectra of RC model as a result of testing pulse excitation measurement method
Open Research DataThe impedance spectrum of RC model object obtained using pulse excitation EIS impedance spectrosocpy measurement method. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. The object under test was built using RC components connected as Baunier model of anticorrosion coating with the following components...
-
Electrical and noise responses of Graphene-Silicon Schottky diodes decorated with Au nanoparticles for light-enhanced sensing of organic gases
Open Research DataGraphene-Silicon Schottky junctions decorated with Au nanoparticles were used for light-enhanced detection of organic tetrahydrofuran and chloroform. Au nanoparticles exhibited localized surface plasmon resonance (LSPR) in the range of yellow light; thus yellow LED (wavelength of 592 nm) was utilized to induce the plasmonic effect, that increased the...
-
Cyclic voltammetry curves for FTO/PANI:WO3 nanocomposite
Open Research DataThis dataset contains the results of kinetic electrochemical studies, carried out with cyclic voltammetry (CV) of FTO/PANI:WO3 nanocomposite at various scan rates: 10, 20, 50, 75, 100 and 200 mV/s. The electrolyte was 1M H2SO4 solution. The measurements were performed in a three electrode setup, and with Ag|AgCl|3M KCl as the reference electrode and...
-
Some problems of slide bearing material fatigue evaluation.
PublicationA slide bearing alloy resistance against fatigue failures have been investigated for three different lubricants, different heat loadings and different stress ratio κ values. The research methods and data handling procedures for determination of particular parameter effects on fatigue strength have been described and analysed for experiments that were set and performed in laboratory tester SKMR-2. Main and interaction effects of...
-
Production of certified reference materials - homogeneity and stability study based on the determination of total mercury and methylmercury
PublicationReference materials (RMs) play an important role in all elements of the quality assurance system of measurements. In this work, ``package'' 4 new CRMs (bottom sediment, herring tissue, cod tissue, cormorant tissue) were prepared and characterised to carry out the quality control in monitoring analysis of mercury and methylmercury in environmental samples. Materials - candidates were collected in Poland and south part of the Czech...
-
AN ORIGINAL APPROACH IN THE FIELD OF PREPARATION REFERENCE MATERIALS OF VOLATILE ANALYTES
PublicationStandard gas mixtures (SGM) are indispensable reference materials for ensuring the reliability of analytical work. Reference materials are an excellent tool for the quality control and assurance of analytical results. Standard gas mixtures are unique among reference materials. The rapid progress of SGM production is connected with the instability of gaseous analytes which make them difficult to obtain. The use of standards with...
-
Laboratory Stand for Wideband Analysis Radiocommunication Signals
PublicationA laboratory stand for wideband analysis radiocommunication signals is presented in the paper. The stand is designed for signals acquisition in wide spectrum and research a field of digital signal processing. Procedures used for simultaneous acquiring many frequency channels in selected wide band are described. The method of detection of direct sequence spread spectrum signals (DS SS) which power spectral density is lower than...
-
Laboratory stand for wideband analysis radiocommunication signals
PublicationA laboratory stand for wideband analysis radiocommunication signals is presented in the paper. The stand is designed for signals acquisition in wide spectrum and research a field of digital signal processing. Procedures used for simultaneous acquiring many frequency channels in selected wide band are described. The method of detection of direct sequence spread spectrum signals (DS SS) which power spectral density is lower than...
-
Non-matrix reference materials-the challenges in the preparation of standard gas mixtures
PublicationIn the last few years particularly great pressure is exerted on quality control and assurance of analytical measurement results. An invaluable role in this process is played by reference materials. The paper presents the characteristics of basic types of reference materials, with particular attention to gaseous reference materials.
-
Local material symmetry group for first- and second-order strain gradient fluids
PublicationUsing an unified approach based on the local material symmetry group introduced for general first- and second-order strain gradient elastic media, we analyze the constitutive equations of strain gradient fluids. For the strain gradient medium there exists a strain energy density dependent on first- and higher-order gradients of placement vector, whereas for fluids a strain energy depends on a current mass density and its gradients....
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 3 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 1 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
The conducted immunity test of a power supply unit in the frequency range from 19 MHz to 26 MHz for the RF voltage level of 10 V
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply unit. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 19 MHz to 26 MHz were...
-
Hybrid Laboratory of Radio Communication With Online Simulators and Remote Access
PublicationContribution: Two toolsets for the remote teaching of radio communication laboratory classes: 1) online simulators for individual work of students and 2) a remote access system to laboratory workstations for group work. Initial assumptions and method of implementation of both tools are presented. Background: The COVID-19 pandemic has forced a change in teaching at all levels of education. The specificity of practical classes, such...
-
Model and laboratory simulation of a induction motor for diagnostic purposes
PublicationStatistics say that bearings are this part of induction motors which is most susceptible to damage. The equipment employed for bearing diagnostics usually makes use of vibrations as the criterion for technical condition of the bearings. A faulty bearing results in additional motor vibrations. They are reflected in the harmonic content of stator currents. In certain operating conditions the current signal is the sole source of information...
-
X-ray Photoelectron Spectroscopy studies of laser-induced titania nanotubes
Open Research DataThis dataset contains the results of high-resolution XPS studies obtained during the formation of the hollow nanopillar arrays through the laser-induced transformation of titania nanotubes.
-
Performance of Haemophilus influenzae impedimetric biosensors based on screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Open Research DataThis dataset contains electrochemical impedance spectroscopy studies of SPCE electrodes containing boron-doped diamond BDD foils and functionalized towards detection of Protein D and Haemophilus influenzae.
-
The microstructure of AA5754 alloy under corrosion in alkaline media (pH=11) with 20 mM of various carboxylic acids
Open Research DataThis dataset contains scanning electron microscopy (SEM) micrographs taken for polished aluminum AA5754 alloy samples, exposed for 100 min in bicarbonate buffer (pH=11) with the addition of 20 mM of carboxylic acids, namely: citric acid, malic acid, maleic acid, succinic acid, tartaric acid, tricarballylic acid and serine. The goal of this study was...
-
The microstructure of AA5754 alloy under corrosion in alkaline media (pH=11) with 4.5 mM of various carboxylic acids
Open Research DataThis dataset contains scanning electron microscopy (SEM) micrographs taken for polished aluminum AA5754 alloy samples, exposed for 100 min in bicarbonate buffer (pH=11) with the addition of 4.5 mM of carboxylic acids, namely: citric acid, malic acid, maleic acid, succinic acid, tartaric acid, tricarballylic acid and serine. The goal of this study was...
-
SEM micrographs of cavitation erosion-corrosion of aluminium alloy 2024 with anodic polarization
Open Research DataThe dataset contains Scanning Electron Micrographs of aluminium alloy 2024 samples made after cavitation erosion-corrosion exposure using a vibratory transducer (in accordance with ASTM G32). The experiment duration was 240 min, with cyclic cavitation exposure in on/off cycles 30s:30s. The electrolyte was 0.1 M KNO3 solution. Some samples were anodically...
-
The hydrogen evolution reaction (HER) performance of some FTO/MoS2/SnO2 electrodes
Open Research DataTo demonstrate the electrochemical performance of the FTO/MoS2/SnO2 for HER (hydrogen evolution reaction), the LSV (linear sweep voltammetry) was performed. The polarization curves of the obtained composite were measured in 1 M H2SO4 at room temperature with a scan rate 10 mV/s. For comparison, the LSV for the FTO, pure MoS2 and Pt plate electrode were...
-
Accuracy Analysis of Determination the Vertical Displacements in Unstable Reference System
PublicationMeasurements of horizontal and vertical displacements are carried out mostly based on reference points identified as fixed. In surveying practice there may be some situations in which there is not possible to perform the measurements with reference to stable points or the difficulties in identification of points’ stability may arise. Accuracy analysis based on the covariance matrices have a special role in this process. In presented...
-
Degradation of reference tyres used for CPX measurements
PublicationMeasurements of tyre/road noise using the Close Proximity Method are based on reference tyres that are described in ISO/TS 11819-3. The standard specifies two tyres, namely "P1" and "H1" that should be used during measurements. To be used for measurements each tyre must fulfill certain conditions that are listed in the standard. The conditions are related to the tread pattern depth and rubber hardness. During experiments performed...
-
Material Religion
Journals -
REFERENCE SERVICES REVIEW
Journals -
Reference Series in Phytochemistry
Journals -
Non-matrix reference matrials- chalanges in the preparation of standard gas mixtures
PublicationIn the last few years particularly great pressure is exerted on quality control and assurance of analytical measurement results. An invaluable role in this process is played by reference materials. The paper presents the characteristics of basic types of reference materials, with particular attention to gaseous reference materials. In addition, a review of literature on techniques of preparation of gaseous standard materials, published...
-
Investigation of the impact of ITRF2014/IGS14 on the positions of the reference stations in Europe
PublicationIn January 2017, the new realization of the International Terrestrial Reference Frame (ITRF) – ITRF2014, was released. Besides the higher accuracy and consistency of the new frame, an entirely new element – the post seismic deformation - was included. Moreover, the definition of the fundamental points has also been changed. All changes related to the new reference frame haveconsequences in the precise positioning using GNSS observations....
-
Temperature influence on tyre/road noise on poroelastic road surface based on laboratory measurements
PublicationThe temperature effect on measured tyre/road noise is very important phenomena as it may lead to significant errors in measurement results due to substantial influence of this parameter on the obtained values. It depends mainly on the particular tyre-road combination. It is different for dense and porous as well as for bituminous and cement concrete pavements. It differs also depending on tested tyre. The correction procedure for...
-
Laboratory assessment of permeability of sand and biopolymer mixtures
PublicationLaboratory assessment of permeability of sand and biopolymer mixtures. This research presents a method of creating seepage barriers in a sandy soil using biopolymer additives (biosubstance), which consist of polysaccharides and water. Polysaccharides strongly interact with water to produce a viscous suspension. The paper aims to investigate the infl uence of a biosubstance employed in a highly permeable sandy soil. Amount of the...
-
Innovative Solutions for Immersive 3D Visualization Laboratory
PublicationThe paper presents results of the work concerning the technical specification of Immersive 3D Visualization Laboratory to be opened in late summer 2014 at the Faculty of Electronics, Telecommunications and Informatics at Gdańsk University of Technology in Poland. The person immersed in VR space will be placed in a transparent sphere with a diameter of over 10 feet, supported on rollers and equipped with a motion tracking system....
-
Wstępne badania technologii spawania złączy narożnych ze stali niskoweglowej i nierdzewnej o grubości g=6mm i g=10mm
PublicationCelem pracy był dobór parametrów spawania dla spoin narożnych o grubości 6mm i 10mm próbek wykonanych ze stali niskowęglowej S355 i stali nierdzewnej - typu 304 (X6CrNI18-10). Złącza były spawane laserowo, jednostronnie z pełnym przetopem a powierzchnie lica i grani zapewniają uzyskanie szczelności przylegającego elementu uszczelniającego. Próbki zostały dostarczone przez Zleceniodawcę. Próby zostały przeprowadzone na stanowisku...
-
Deep Instance Segmentation of Laboratory Animals in Thermal Images
PublicationIn this paper we focus on the role of deep instance segmentation of laboratory rodents in thermal images. Thermal imaging is very suitable to observe the behaviour of laboratory animals, especially in low light conditions. It is an non-intrusive method allowing to monitor the activity of animals and potentially observe some physiological changes expressed in dynamic thermal patterns. The analysis of the recorded sequence of thermal...
-
Material Identification of the Human Abdominal Wall Based On the Isogeometric Shell Model
PublicationThe human abdominal wall is an object of interest to the research community in the context of ventral hernia repair. Computer models require a priori knowledge of constitutive parameters in order to establish its mechanical response. In this work, the Finite Element Model Updating (FEMU) method is used to identify an heterogeneous shear modulus distribution for a human abdominal wall model, which is based on nonlinear isogeometric...
-
The electrochemical response to glassy carbon electrode modification steps towards viral electrochemical immunosensor preparation
Open Research DataThe dataset contains the electrochemical measurements (CV/EIS) carried out for the consecutive steps of the glassy carbon GC electrode functionalization, in separate subfolders, as described. The cyclic voltammetry (CV) was conducted using a Palmsens 4 potentiostat/galvanostat system (Methrom, Autolab, Netherlands) in the standard three-electrode configuration,...
-
Metabolomics for laboratory diagnostics
Publication -
The use of a two-phase Monte Carlo material model to reflect the dispersion of asphalt concrete fracture parameters
PublicationThe work covers comprehensive laboratory tests of semi-circular bending (SCB) of asphalt concrete samples. The results of two test series, including four and 32 SCB specimens, indicate a substantial scatter of force–deflection (F-d) histories. The numerical analysis is aimed to reflect the maximum breaking load and fracture energy of the samples, pointing out their random character. The original simulation-based fictitious Monte...