Filters
total: 5176
-
Catalog
- Publications 3798 available results
- Journals 72 available results
- People 106 available results
- Inventions 1 available results
- Projects 5 available results
- Laboratories 1 available results
- Research Equipment 1 available results
- e-Learning Courses 103 available results
- Events 2 available results
- Open Research Data 1087 available results
displaying 1000 best results Help
Search results for: LABORATORY REFERENCE MATERIAL
-
Exploration of optical fibres as a carrier for new benzene and toluene matrix-free reference materials
PublicationTo meet high expectations concerning precision and accuracy of reference materials, preparation of matrixfree reference materials using thermal decomposition-gas chromatography-mass spectrometry (TD-GC-MS) was proposed in this study. In the paper, the results obtained in preparation of the new reference materials for benzene and toluene are presented, based on the thermal decomposition technique of compounds chemically bound to...
-
Design and implementation of GEPON architecture in laboratory testbed
PublicationThis paper presents a proposition of GEPON architecture for the didactic purpose. The GEPON architecture is implemented in access networks laboratory testbed. The paper includes a brief description of GEPON standardization, a description of laboratory GEPON equipment architecture and a short presentation of proposed laboratory exercises. The exemplary performance results are included.The proposition of GEPON architecture testbed...
-
A LABORATORY STAND FOR THE ANALYSIS OF DYNAMIC PROPERTIES OF THERMOCOUPLES
PublicationIn the present elaboration, problems connected with measurements of high variable temperatures of gases are introduced and the impact of dynamic properties of different construction solutions of thermoelements on the accuracy of the measurements is considered. A laboratory stand built within research under doctoral thesis, destined for analysis of dynamic properties of thermocouples is also described. Results of numerical simulation...
-
A material model of asphalt mixtures based on Monte Carlo simulations
PublicationThe paper aims to numerically reflect mineral-asphalt mixture structure by a standard FEM software. Laboratory test results are presented due to bending tests of circular notched elements. The result scatter is relatively high. An attempt was made to form a random aggregate distribution in order to obtain various results corresponding to laboratory tests. The material structure calibration, its homogenization and finite element...
-
Mariusz Figurski prof. dr hab. inż.
PeopleMariusz Józef Figurski (born 27 April 1964 in Łasinie, Poland) - Polish geodesist, professor of technical sciences, professor at the Gdańsk University of Technology. Early life and education He passed the matriculation examination in 1983 after he had finished Jan III Sobieski High school in Grudziądz. He graduated the Military University of Technology on an individual mode at the Faculty of Electromechanics and Civil Engineering...
-
Electrochemical studies of Boron-Doped Diamond enriched Laser Induced Graphene structures
Open Research DataThis dataset contains electrochemical studies aimed to evaluate the capability of the utilization of laser-induced graphene (LIG) with incorporated boron-doped diamond nanowall (BDNW) hybrid nanostructures for microsupercapacitors. Selected results from this dataset were published in Advanced Functional Materials journal: https://doi.org/10.1002/adfm.202206097
-
Development of potential candidate reference materials for drugs in bottom sediment, cod and herring tissues
PublicationRegular use of a reference material and participation in a proficiency testing program can improve the reliability of analytical data. This paper presents the preparation of candidate reference materials for the drugs metoprolol, propranolol, carbamazepine, naproxen, and acenocoumarol in freshwater bottom sediment and cod and herring tissues. These reference materials are not available commercially. Drugs (between 7 ng/g and 32...
-
Topography studies of screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Open Research DataThis dataset contains topography examination of SPCE containing boron-doped diamond BDD foils done with scanning electron microscope. Different points mark different electrode spots: A) working electrode, B) reference electrode, C) counter electrode, D) pads.
-
Electric Machines Virtual Laboratory
e-Learning CoursesThis is an educational aid for students. It shows the environment of industrial application of electric machines and allows for a look inside them. Users can see the main components of the power system in its natural environment. This course is to allow access to the VR app – Electric Machines Virtual Laboratory.
-
Electrocatalytic gas sensor with reference layer
PublicationIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
The application of TD-GC-FID technique for production of matrix-free reference materials
PublicationIn the last few years particular pressure is exerted on finding new analytical methods which would provide real possibilities of monitoring and control of the state of the environment. Intensive development of analytical techniques for measurements of gaseous media and the negative effects of BTX compounds make it necessary to produce new gaseous reference materials. To prepare the appropriate non- matrix reference material thermal...
-
On Dynamic Extension of a Local Material Symmetry Group for Micropolar Media
PublicationFor micropolar media we present a new definition of the local material symmetry group considering invariant properties of the both kinetic energy and strain energy density under changes of a reference placement. Unlike simple (Cauchy) materials, micropolar media can be characterized through two kinematically independent fields, that are translation vector and orthogonal microrotation tensor. In other words, in micropolar continua...
-
Image projection in Immersive 3D Visualization Laboratory
PublicationIn recent years, many centers in the world attempted to build a virtual reality laboratory. The main idea of such laboratory is to allow the user to “immerse” into and move in a computer-generated virtual world. In the paper, the underlying principles of the system of virtual reality (VR) are described. The selected implementations constructed by the research centers of the world are also presented. The cave automatic virtual environment...
-
Electrocatalytic Gas Sensor with Reference Layer
PublicationThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Blurred quantum Darwinism across quantum reference frames
PublicationQuantum Darwinism describes objectivity of quantum systems via their correlations with their environment--information that hypothetical observers can recover by measuring the environments. However, observations are done with respect to a frame of reference. Here, we take the formalism of [Giacomini, Castro-Ruiz, & Brukner. Nat Commun 10, 494 (2019)], and consider the repercussions on objectivity when changing quantum reference...
-
Comparison of road and laboratory measurements of tyre/road noise
PublicationTyre/road noise is one of the major environmental problems related to road traffic. There are several measuring methods of tyre/road noise that may be carried out on the road (for example Coast-down and Close Proximity Method) or in the laboratory (Drum Method). Road measurements are preferred for evaluations of pavement properties while laboratory methods are mostly used to evaluate tyres. One of the biggest problems associated...
-
Imaging of biological samples: the ant Lasius Niger
Open Research DataThe world of arthropods continues to amaze researchers today. An example may be a relatively new report by a group of scientists on structures found in ant shells [1] Although calcareous anatomical structures have evolved in various groups of animals, little has been known so far about the occurrence of this type of form in insects. The authors of the...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Electrochemical measurements of borophene functionalized with nickel(II) oxide (NiO)
Open Research DataThis dataset contains linear sweep voltammetry (LSV) and chronopotentiometry (CP) technique results for borophene functionalized with nickel(II) oxide (NiO) and reference samples: ruthenium(IV) oxide (RuO2), nickel(II) oxide (NiO) and pristine borophene. Linear sweep voltammetry (LSV) results show the oxygen evolution reaction permormance of the obtained...
-
Rain Gardens LC_MS/MS analysis dataset
Open Research DataThis dataset contains the results of samples analysis (target analysis with certified reference materials) using ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS, Shimadzu, Japan).
-
Cold recycled mixtures for binder courses - laboratory evaluation of mechanical properties
PublicationCold recycled mixtures composed with cement and bituminous emulsion are nowadays commonly used material for base layer. Typical pavement with cold recycled mixtures usually consists of two asphalt courses (wearing and binding course) constructed over cold recycled base. Therefore the next step in cold recycling is possibility of design of binding courses with recycled materials, but with potential to obtain high quality mixtures...
-
DWDM Network Laboratory Solution for Telecommunication Education Engineering
PublicationDevelopment of network architectures in the field of optical telecommunications technologies is an indicator of changes in telecommunication education engineering. Conducting didactic classes requires hardware infrastructure and research in terms of teaching needs. In the paper we present DWDM network laboratory solution for telecommunication education engineering on the basis of the ADVA Optical Networking equipment. We have to...
-
Experimentation, material modelling and simulation of bonded joints with a flexible adhesive
PublicationThe paper deals with material parameters identification of a flexible adhesive and the numerical simulation of its behaviour in a single lap bonded joint. The material modelling was based on the simple shear and tensile-shear laboratory tests of the bonded joints made of thin aluminium and polyurethane plates with the flexible adhesive Terostat MS 9360 manufactured by Henkel AG & Co. The adhesive was considered as a hyperelastic...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Chemical and structural studies of screen-printed carbon electrodes (SPCE) with boron-doped diamond foils
Open Research DataThis dataset contains chemical analyses and structural studies by XPS and Raman spectroscopy, carried out for SPCE containing boron-doped diamond BDD foils done with scanning electron microscope. Different points for XPS analysis mark different electrode spots: A) working electrode, B) reference electrode, C) counter electrode, D) pads.
-
Laboratory stand for wideband analysis radiocommunication signals
PublicationA laboratory stand for wideband analysis radiocommunication signals is presented in the paper. The stand is designed for signals acquisition in wide spectrum and research a field of digital signal processing. Procedures used for simultaneous acquiring many frequency channels in selected wide band are described. The method of detection of direct sequence spread spectrum signals (DS SS) which power spectral density is lower than...
-
Laboratory Stand for Wideband Analysis Radiocommunication Signals
PublicationA laboratory stand for wideband analysis radiocommunication signals is presented in the paper. The stand is designed for signals acquisition in wide spectrum and research a field of digital signal processing. Procedures used for simultaneous acquiring many frequency channels in selected wide band are described. The method of detection of direct sequence spread spectrum signals (DS SS) which power spectral density is lower than...
-
The effect of tire aging on acoustic performance of CPX reference tires
PublicationReduction of tire/road noise is one of the biggest environmental challenges of road traffic. To reduce that noise it is necessary to perform acoustic measurements on the base of wellproven standard procedures. One method of measurements that is in common use, namely the Close Proximity Method (CPX), is described in standard ISO-DIS 11819-2. As this method is used to classify road surfaces regarding their influence on vehicle noise,...
-
Some problems of slide bearing material fatigue evaluation.
PublicationA slide bearing alloy resistance against fatigue failures have been investigated for three different lubricants, different heat loadings and different stress ratio κ values. The research methods and data handling procedures for determination of particular parameter effects on fatigue strength have been described and analysed for experiments that were set and performed in laboratory tester SKMR-2. Main and interaction effects of...
-
Hybrid Laboratory of Radio Communication With Online Simulators and Remote Access
PublicationContribution: Two toolsets for the remote teaching of radio communication laboratory classes: 1) online simulators for individual work of students and 2) a remote access system to laboratory workstations for group work. Initial assumptions and method of implementation of both tools are presented. Background: The COVID-19 pandemic has forced a change in teaching at all levels of education. The specificity of practical classes, such...
-
Model and laboratory simulation of a induction motor for diagnostic purposes
PublicationStatistics say that bearings are this part of induction motors which is most susceptible to damage. The equipment employed for bearing diagnostics usually makes use of vibrations as the criterion for technical condition of the bearings. A faulty bearing results in additional motor vibrations. They are reflected in the harmonic content of stator currents. In certain operating conditions the current signal is the sole source of information...
-
Configuration of the reference stations as the element of national reference frame reliability
Publication -
Production of certified reference materials - homogeneity and stability study based on the determination of total mercury and methylmercury
PublicationReference materials (RMs) play an important role in all elements of the quality assurance system of measurements. In this work, ``package'' 4 new CRMs (bottom sediment, herring tissue, cod tissue, cormorant tissue) were prepared and characterised to carry out the quality control in monitoring analysis of mercury and methylmercury in environmental samples. Materials - candidates were collected in Poland and south part of the Czech...
-
Impedance spectra of RC model as a result of testing pulse excitation measurement method
Open Research DataThe impedance spectrum of RC model object obtained using pulse excitation EIS impedance spectrosocpy measurement method. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. The object under test was built using RC components connected as Baunier model of anticorrosion coating with the following components...
-
Cyclic voltammetry curves for FTO/PANI:WO3 nanocomposite
Open Research DataThis dataset contains the results of kinetic electrochemical studies, carried out with cyclic voltammetry (CV) of FTO/PANI:WO3 nanocomposite at various scan rates: 10, 20, 50, 75, 100 and 200 mV/s. The electrolyte was 1M H2SO4 solution. The measurements were performed in a three electrode setup, and with Ag|AgCl|3M KCl as the reference electrode and...
-
Electrical and noise responses of Graphene-Silicon Schottky diodes decorated with Au nanoparticles for light-enhanced sensing of organic gases
Open Research DataGraphene-Silicon Schottky junctions decorated with Au nanoparticles were used for light-enhanced detection of organic tetrahydrofuran and chloroform. Au nanoparticles exhibited localized surface plasmon resonance (LSPR) in the range of yellow light; thus yellow LED (wavelength of 592 nm) was utilized to induce the plasmonic effect, that increased the...
-
AN ORIGINAL APPROACH IN THE FIELD OF PREPARATION REFERENCE MATERIALS OF VOLATILE ANALYTES
PublicationStandard gas mixtures (SGM) are indispensable reference materials for ensuring the reliability of analytical work. Reference materials are an excellent tool for the quality control and assurance of analytical results. Standard gas mixtures are unique among reference materials. The rapid progress of SGM production is connected with the instability of gaseous analytes which make them difficult to obtain. The use of standards with...
-
Material Religion
Journals -
Local material symmetry group for first- and second-order strain gradient fluids
PublicationUsing an unified approach based on the local material symmetry group introduced for general first- and second-order strain gradient elastic media, we analyze the constitutive equations of strain gradient fluids. For the strain gradient medium there exists a strain energy density dependent on first- and higher-order gradients of placement vector, whereas for fluids a strain energy depends on a current mass density and its gradients....
-
REFERENCE SERVICES REVIEW
Journals -
Reference Series in Phytochemistry
Journals -
Temperature influence on tyre/road noise on poroelastic road surface based on laboratory measurements
PublicationThe temperature effect on measured tyre/road noise is very important phenomena as it may lead to significant errors in measurement results due to substantial influence of this parameter on the obtained values. It depends mainly on the particular tyre-road combination. It is different for dense and porous as well as for bituminous and cement concrete pavements. It differs also depending on tested tyre. The correction procedure for...
-
Laboratory assessment of permeability of sand and biopolymer mixtures
PublicationLaboratory assessment of permeability of sand and biopolymer mixtures. This research presents a method of creating seepage barriers in a sandy soil using biopolymer additives (biosubstance), which consist of polysaccharides and water. Polysaccharides strongly interact with water to produce a viscous suspension. The paper aims to investigate the infl uence of a biosubstance employed in a highly permeable sandy soil. Amount of the...
-
Innovative Solutions for Immersive 3D Visualization Laboratory
PublicationThe paper presents results of the work concerning the technical specification of Immersive 3D Visualization Laboratory to be opened in late summer 2014 at the Faculty of Electronics, Telecommunications and Informatics at Gdańsk University of Technology in Poland. The person immersed in VR space will be placed in a transparent sphere with a diameter of over 10 feet, supported on rollers and equipped with a motion tracking system....
-
Non-matrix reference materials-the challenges in the preparation of standard gas mixtures
PublicationIn the last few years particularly great pressure is exerted on quality control and assurance of analytical measurement results. An invaluable role in this process is played by reference materials. The paper presents the characteristics of basic types of reference materials, with particular attention to gaseous reference materials.
-
Deep Instance Segmentation of Laboratory Animals in Thermal Images
PublicationIn this paper we focus on the role of deep instance segmentation of laboratory rodents in thermal images. Thermal imaging is very suitable to observe the behaviour of laboratory animals, especially in low light conditions. It is an non-intrusive method allowing to monitor the activity of animals and potentially observe some physiological changes expressed in dynamic thermal patterns. The analysis of the recorded sequence of thermal...
-
Wstępne badania technologii spawania złączy narożnych ze stali niskoweglowej i nierdzewnej o grubości g=6mm i g=10mm
PublicationCelem pracy był dobór parametrów spawania dla spoin narożnych o grubości 6mm i 10mm próbek wykonanych ze stali niskowęglowej S355 i stali nierdzewnej - typu 304 (X6CrNI18-10). Złącza były spawane laserowo, jednostronnie z pełnym przetopem a powierzchnie lica i grani zapewniają uzyskanie szczelności przylegającego elementu uszczelniającego. Próbki zostały dostarczone przez Zleceniodawcę. Próby zostały przeprowadzone na stanowisku...
-
Accuracy Analysis of Determination the Vertical Displacements in Unstable Reference System
PublicationMeasurements of horizontal and vertical displacements are carried out mostly based on reference points identified as fixed. In surveying practice there may be some situations in which there is not possible to perform the measurements with reference to stable points or the difficulties in identification of points’ stability may arise. Accuracy analysis based on the covariance matrices have a special role in this process. In presented...
-
Degradation of reference tyres used for CPX measurements
PublicationMeasurements of tyre/road noise using the Close Proximity Method are based on reference tyres that are described in ISO/TS 11819-3. The standard specifies two tyres, namely "P1" and "H1" that should be used during measurements. To be used for measurements each tyre must fulfill certain conditions that are listed in the standard. The conditions are related to the tread pattern depth and rubber hardness. During experiments performed...