Solubility of carbon dioxide in water: Some useful results for hydrate nucleation
PublicationIn this paper, the solubility of carbon dioxide (CO2) in water along the isobar of 400 bar is determined by computer simulations using the well-known TIP4P/Ice force field for water and the TraPPE model for CO2. In particular, the solubility of CO2 in water when in contact with the CO2 liquid phase and the solubility of CO2 in water when in contact with the hydrate have been determined. The solubility of CO2 in a liquid–liquid...
-
Principles and Developments of Solid-Phase Microextraction
PublicationSample preparation has been commonly considered a critical step of the analytical process. In this sense, remarkable efforts have been made to develop efficient sample preparation techniques which could overcome the limitations of conventional approaches. Since its inception in the early 1990’s, solid-phase microextraction (SPME) has become a widespread miniaturized sample preparation technique for extraction and preconcentration...
-
Evaluation of polycaprolactone as a new sorbent coating for determination of polar organic compounds in water samples using membrane–SPME
PublicationCommercially available solid-phase microextraction fibers used for isolation of polar analytes are based on the adsorption phenomenon. In consequence, typical limitations bonded with analytes displacement and matrix effects are very frequent. In the present study, alternative solution is described. Polycaprolactone (PCL) was used for the first time as sorbent to isolate polar organic compounds from water samples using the membrane–solid-phase...
-
Determination of volatile organic compounds in water samples using membrane-solid phase microextraction (M-SPME) (headspace version)
PublicationThe results of a study on the use of membrane-solid phase microextraction (M-SPME) for sampling volatile organic compounds (VOCs) from the headspace above the liquid medium are presented. The sampled VOCs were subsequently quantified by gas chromatography (GC). Two systems were compared in this study, i.e. a novel two-phase sorption system (M-SPME), and a commercial fibre. Headspace sampling using SPME was optimized with respect...
-
Mechanical Behavior of Bi-Layer and Dispersion Coatings Composed of Several Nanostructures on Ti Substrate
PublicationThree coatings suitable for biomedical applications, including the dispersion coating composed of multi-wall carbon nanotubes (MWCNTs), MWCNTs/TiO2 bi-layer coating, and MWCNTs-Cu dispersion coating, were fabricated by electrophoretic deposition (EPD) on Ti Grade II substrate. Optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and nanoindentation were applied to study topography, chemical, and...
-
Quechers sample preparation method variants for analysis of pesticide residues in fruits and vegetables
PublicationThis article describes the comparison of different versions of an easy, rapid and low-cost sample preparation approach for the determination of pesticide residues in fruits and vegetables by concurrent use of gas and liquid chromatography coupled to MS or ECD for detection. The sample preparation approach is known as QuEChERS, which stands for quick, easy, cheap, effective, rugged and safe. It is a combination of liquid-liquid...
-
Direct solid phase microextraction combined with gas chromatography – Mass spectrometry for the determination of biogenic amines in wine
PublicationA direct method based on immersion solid phase microextraction (DI-SPME) gas chromatography mass-spectrometry (GC-MS) was optimized and validated for the determination of 16 biogenic amines in Polish wines. In the analysis two internal standards were used: 1,7-diaminoheptane and bis-3-aminopropylamine. The method allows for simultaneous extraction and derivatization, providing a simple and fast mode of extraction and enrichment....
-
A new dilution-enrichment sample preparation strategy for expanded metabolome monitoring of human breast milk that overcomes the simultaneous presence of low- and high-abundance lipid species
PublicationThe complex nature of human breast milk (HBM) makes samples difficult to analyze, requiring several extraction techniques and analytical platforms to obtain high metabolome coverage. In this work, we combined liquid-liquid extraction (LLE) and solid-phase extraction (SPE) techniques to prepare HBM samples to overcome the challenge of low- and high-abundance lipid species, enabling the semiquantitative analysis of total HBM lipids...
-
Application of response surface methodology to optimize solid-phase microextraction procedure for chromatographic determination of aroma-active monoterpenes in berries
PublicationMost of scientific papers concern the qualitative or semi-quantitative analysis of aroma-active terpenes in liquid food matrices. Therefore, the procedure based on solid-phase microextraction and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry for determination of monoterpenes in fresh berries was developed. The optimal extraction conditions using divinylbenzene-carboxen-polydimethylsiloxane fiber...
-
Multi-residue method for the determination of 16 recently used pesticides from various chemical groups in aqueous samples by using DI - SPME coupled with GC-MS
PublicationA simple and solvent-free multi-residue method has been optimized to determine 16 currently used pesticides from different chemical groups in aqueous samples. The extraction of analytes was carried out with direct immersion solid-phase microextraction (DI-SPME) and for the identification and quantitative determination gas chromatography coupled with mass spectrometry (GC-MS) was applied. Two commonly used adsorbent coatings have...
-
Determination of flavanols by liquid chromatography with fluorescence detection. Application to the characterization of cranberry-based pharmaceuticals through profiling and fingerprinting approaches
PublicationIn this work, a new method based on reversed-phase high-performance liquid chromatography (HPLC) with fluorescence detection (FLD) was established for the determination of catechins and related oligomeric proanthocyanidins (PACs) in cranberry-based pharmaceuticals. Compounds were recovered by liquid extraction using methanol/water/hydrochloric acid (60:39:1, v:v:v) as the extraction solvent. The chromatographic separation was carried...
-
Membrane-SPME the best 'green' sample preparation technique for the gas chromatographic determination polar organic pollutants in polar media
PublicationOne of the most popular technique for sample preparation, which fulfill requirements of green analytical chemistry, is solid phase microextraction (SPME). Because of the undoubted advantages of SPME technique, solvent-free character of the extraction process and the enormous potential in analytical practice, a series of studies has been undertaken to develop new technical solutions, where improving the sensitivity and the extraction...
-
Determination of antifreeze substances in the airport runoff waters by solid-phase microextraction and gas chromatography–mass spectrometry method
PublicationA new method has been developed for the determination of antifreeze agents such as ethylene glycol (EG), propylene glycol (PG), and diethylene glycol (DEG) in the samples of airport runoff water. The method is based on headspace solid–phase microextraction (HS–SPME) of target analytes, which is coupled with gas chromatography–mass spectrometry (GC–MS). Until now, there was a lack of appropriate methodology for collecting reliable...
-
RF Input-Quasi-Reflectionless Dispersive-Delay Structures Based on Complementary-Diplexer Circuits
PublicationA class of RF dispersive-delay structures (DDSs) with input-quasi-reflectionless behavior is reported. It is based on the exploitation of complementary-diplexer circuit networks, in which the out-of-band RF-input-power echoes reflected by the main bandpass-filter-(BPF)-type channel are dissipated by the resistively-terminated auxiliary bandstop-filter-(BSF)-type channel. Specifically, it is shown that the influence of the absorptive...
-
Multimodal Genetic Algorithm with Phase Analysis to Solve Complex Equations of Electromagnetic Analysis
PublicationIn this contribution, a new genetic-algorithm-based method of finding roots and poles of a complex function of a complex variable is presented. The algorithm employs the phase analysis of the function to explore the complex plane with the use of the genetic algorithm. Hence, the candidate regions of root and pole occurrences are selected and verified with the use of discrete Cauchy's argument principle. The algorithm is evaluated...
-
2-Methylphenyl 2-methoxyacridine-9-carboxylate
PublicationThe title compound, C22H17NO3, crystallizes in the monoclinic space group P21/c with four molecules per unit cell. The molecules are arranged in centrosymmetric pairs, joined via the C and attached H atoms in the meta position relative to the methoxy group. These pairs are bonded in the crystalline phase as a result of non-specific dispersive interactions, and through a network of C—H⋯O interactions involving the non-bonded O...
-
DETERMINATION OF SURFACTANTS IN ENVIRONMENTAL SAMPLES - PART I. CATIONIC COMPOUNDS = Oznaczanie Surfaktantów W Próbkach Środowiskowych. Część I. Związki Kationowe
PublicationCompounds from the group of cationic surfactants are widely applied in household, industrial, cleaning, disinfectant, cosmetic and pharmaceutical products as their specific properties (antimicrobial, emulsifying, anticorrosion, softening). After use, cationic surfactants are disposed to wastewater-treatment plants and finally with effluent water to surface waters due to their incomplete degradation. Moreover, they can freely circulate...
-
Ekstrakcja do fazy stałej niejedno ma imię
PublicationW czasach, gdy we wszystkich przejawach aktywności człowieka trzeba się odnieść do przesłanek leżących u podstaw zrównoważonego rozwoju trudno jest uzasadnić stosowanie w praktyce analitycznej takich procedur i operacji, które pociągają za sobą konieczność:użycia dużych ilości rozpuszczalników i odczynników chemicznychdużych nakładów energii czy też przyczyniają się do wzrostu ekspozycji pracowników laboratoriów na niekorzystne...
-
DETERMINATION OF SURFACTANTS IN ENVIRONMENTAL SAMPLES. PART II. ANIONIC COMPOUNDS
PublicationSurfactants (SAA) with negative charge of polar group are named as anionic compounds. They are main constituent of most products containing synthetic surfactants. The linear alkylbenzene sulfonates (LAS), alkyl ethoxysulfates (AES) and alkyl sulfates (AS) are typically applied from this class of compounds. Those surfactants are ingredients of household detergents and cleaners, laundry detergents, cosmetic. Moreover they can be...
-
Chemical Derivatization Processes Applied to Amine Determination in Samples of Different Matrix Composition
PublicationAmines are important biological compounds, and so their analysis and monitoring in various matrices is worthy of investigation and development.Due to the polar nature of amines, chromatographic analysis of free amines is generally unsatisfactory owing to adsorption and decomposition of the solute on the column, resulting in peak tailing and losses. Therefore, many derivatization reactions are employed to reduce the polarity, improve...
-
Structural and mechanical properties of hydroxyapatite coatings formed by ion-beam assisted deposition
PublicationThe ion-beam assisted deposition (IBAD) is an advanced method capable of producing crystalline coatings at low temperatures. We determined the characteristics of hydroxyapatite Ca10(PO4)6(OH)2 target and coatings formed by IBAD using X-ray photoemission spectroscopy (XPS), X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM) and energy dispersive X-ray (EDX). The composition of the coatings'...
-
Efficient Extraction of Fermentation Inhibitors by Means of Green Hydrophobic Deep Eutectic Solvents
PublicationThe methods for hydrogen yield efficiency improvements, the gaseous stream purification in gaseous biofuels generation, and the biomass pretreatment are considered as the main trends in research devoted to gaseous biofuel production. The environmental aspect related to the liquid stream purification arises. Moreover, the management of post-fermentation broth with the application of various biorefining techniques gains importance....
-
RF Multi-Functional Input-Reflectionless Dispersive-Delay Structure With Sharp-Rejection Filtering Using Channelization Techniques
PublicationA class of RF multi-functional input-reflectionless dispersive-delay structure (DDS) with linear-type in-band groupdelay variation and sharp-rejection bandpass-filtering capability is reported. It exploits a two-branch-channelized/balanced-type circuit with similar low-order reflective DDS units inside its channels, which are connected through input/output 3-dB quadrature wideband couplers. The adopted DDS unit is based on a coupledresonator...
-
Electronic and ionic relaxations in strontium-borate glass and glass-ceramics containing bismuth and vanadium oxides
PublicationThe topography, microstructure and electrical properties of strontium-borate glass and SBO glass containing bismuth and vanadium oxides, were studied. The structure was measured using X-ray diffraction (XRD), Energy Dispersive X-ray Spectrometer (EDS) and Scanning electron microscope (SEM) methods. The A.C. complex conductivity was investigated as a function of temperature and frequency. The influence of the quantity of bismuth...
-
Solid phase microextraction–comprehensive twodimensional gas chromatography–time-of-flight mass spectrometry: a new tool for determining PAHs in airport runoff water samples
Publicationfundamental aspect of airport operations is the pollution caused by airport runoff waters. Polycyclic aromatic hydrocarbons (PAHs) are one of the most important groups of xenobiotics which are commonly found in runoff water originating from airports. Only very limited data on the analysis of airport runoff water have been published until now. Therefore, a reliable and accurate analytical method based on headspace solid-phase microextraction...
-
Evaluation of Green Sample Preparation Techniques for Organic Compounds
PublicationNowadays, Green Analytical Chemistry (GAC) idea is of high importance, with impact on the rapid growth in the sample preparation area with special emphasis on sample preparation simplification, miniaturization and automation. Due to the fact that GAC is of high importance today, this study is focused on the evaluation of green sample preparation techniques for organic compounds. It is well known that sample preparation is considered...
-
Ionic liquids in the microextraction techniques: the influence of ILs structure and properties
PublicationIonic liquids (ILs) are composed entirely of ions thus they possess unique properties, including negligible volatility, a liquid state in a broad range of temperatures and ability to change them depending on the chosen type of anion and cation, which make ILs unique and useful for many applications in sample preparation techniques. A deeper understanding of the nature of ILs and the impact of their structure on their parameters...
-
A Linear Phase Filter in Quadruplet Topology With Frequency-Dependent Couplings
PublicationThis letter presents a design of a linear phase microwave bandpass filter. The filter is composed of four resonators arranged in the quadruplet topology. Making the cross and one direct coupling dispersive gives additional design flexibility. The first advantage of using frequency-dependent couplings is the possibility to chose an arbitrary location of a pair of complex transmission zeros (TZs) in the s-domain. The second one is...
-
Rapid Characterization of the Human Breast Milk Lipidome Using a Solid-Phase Microextraction and Liquid Chromatography-Mass Spectrometry-Based Approach.
PublicationHuman breast milk (HBM) is a biofluid consisting of various biomolecules such as proteins, lipids, carbohydrates, minerals and bioactive substances. Due to its unique and complex composition, HBM provides not only nutritional components required for the growth of the infant, but also additional protection against infections. Global insight into the composition of HBM is crucial to understanding the health benefits infants receive...
-
Lab-in-syringe as a practical technique for automatic microextraction: Evaluation by Blue Applicability Grade Index
PublicationLab-in-syringe (LIS) is a powerful automatic technique that is derived from sequential injection analysis. In LIS, a computer-controlled syringe pump is employed, and its syringe barrel serves as a mixing, reaction, and/or extraction chamber. Until now, the LIS concept has been efficiently employed for the automation of solid-phase microextraction and liquid-phase microextraction protocols as a front-end to a plethora of chromatographic...
-
Speciation of heavy metals in wastewater and rejected waters from multistage bioreactors (MUCT)
PublicationThe objective of the study is to investigate the occurrence and availability of selected heavy metals after subsequent stages of treatment in WWTP with activated sludge (enhanced biological N and P removal). To achieved the target it was necessary to recognize the allocation of selected heavy metals between aqueous and solid phase in wastewater and reject waters. Application of sequential extraction of such metals as Cd Zn, Pb,...
-
Nowe rozwiązania metodyczne i techniczne w zakresie techniki mikroekstrakcji do fazy stracjonarnej
PublicationSample preparation has been recognized as a critical step of the analytical process, being even considered as the bottleneck of the overall process. Enrichment of target compounds, transfer of the analytes into a solvent compatible with the analytical instrumentation, minimization of potential interferences, and efficient sample clean-up, are among the main aims of sample preparation techniques. In this regard, liquid-liquid extraction...
-
Novel fast analytical method for indirect determination of MCPD fatty acid esters in edible oils and fats based on simultaneous extraction and derivatization
PublicationA novel method for indirect determination of MCPD esters levels in lipid samples has been developed. The method is based on combination of extraction and derivatisation in the same sample preparation step. It is achieved by the application of diethyl ether as extraction solvent for isolation of released from esterified forms analytes from water phase and dilution solvent for solid PBA – derivatisation agent. It is a noteworthy...
-
Challenges in determination of pesticides from various chemical groups in fruits and vegetables applying QuEChERS method
PublicationPesticides are a large group of compounds with different physical and chemical properties, which place some of them among the most toxic, environmentally stable, and mobile substances. Nevertheless, their number, use, and application are continuously expanding. A consequence of their use is the possible presence of residues in treated food products. To protect consumers from exposure to unacceptable levels of pesticides Maximum...
-
Identification and characterization of the Indian Yellow dyestuff and its degradation products in historical oil paint tube by liquid chromatography mass spectrometry
PublicationAn analytical protocol for identification of dyes using reversed phase liquid chromatography-mass spectrometry with atmospheric pressure electrospray ionization (LC-ESI/MS) is presented. The developed method has been successfully applied in identification of euxanthic acid and euxanthone, the main components of the Indian Yellow dye in a historical oil paint tube produced by Richard Ain`es, a recognizable French company supplying...
-
Application of Headspace Solid-phase Microextraction with Poly(1-vinyl-3- Hexylimidazolium Chloride) Polymeric Ionic Liquid Coating using GC - MS to Determine Volatile Fatty Acids in Dairy Wastewater
PublicationVolatile fatty acids were determined in this study using headspace solid-phase microextraction (HS-SPME) with a poly(1-vinyl-3-hexylimidazolium chloride) polymeric ionic liquid coated fiber followed by gas chromatography - mass spectrometry. Experimental parameters such as extraction time and temperature, sample volume as well as desorption time and temperature were optimized. Detection limits of the method were in the range of...
-
Effect of shallow traps on admittance spectra of the system carrying SCLC and on values of charge carrier mobility extracted from susceptance
PublicationThe work concerns small-signal spectra of space-charge-limited current below threshold frequency (ft) of shallow traps. It is shown that below ft the small-signal concentration of trapped charge carriers is proportional to and in phase with small-signal concentration of free charge carriers, so there is no room for “slow shallow traps”. Conductance can be reduced by the traps, however no change in the range of real capacitance...
-
Direct injection liquid chromatography-mass spectrometry (DI-LC-MS) analysis for rapid lipidomic profiling of extracellular vesicles
PublicationExtracellular vesicles (EVs) are small, spherical particles produced by eukaryotic and prokaryotic cells, surrounded by a bilayer membrane and carrying various bioactive molecules, such as proteins, surface receptors, membrane and soluble proteins, lipids, and nucleic acids. EVs are of substantial interest because of their important roles in cell communication, epigenetic regulation and possible application in disease diagnosis...
-
Development and Validation of SPE-HPLC-MS/MS Method for Determining Cyclophosphamide in Surface Waters
PublicationA rapid and selective method for trace amounts determination of cyclophosphamide in surface water samples has been developed. A solid phase extraction SPE method for extraction and clean-up procedure has been optimized for determination by reversed-phase high-performance liquid chromatography with tandem mass spectrometry. The analyses proceed in the positive ion mode by means of the electrospray ionization method (ESI). Clean...
-
Transparent thin films of Cu-TiO2 with visible light photocatalytic acitivity
PublicationThin films of Cu–TiO2 with a high level of transparency were prepared by a dip-coating procedure on the glass surface. CuCl2 was used as a copper precursor added during sol – gel synthesis of TiO2. The extension of optical absorption into the visible region of as-prepared thin films was indicated by UV/Vis spectroscopy. Only the anatase phase was detected by X-ray di ffraction analysis (XRD). The presence of copper in the structure...
-
The Influence of Nanometals, Dispersed in the Electrophoretic Nanohydroxyapatite Coatings on the Ti13Zr13Nb Alloy, on Their Morphology and Mechanical Properties
PublicationIn this work, nanohydroxyapatite coatings with nanosilver and nanocopper have been fabricated and studied. The presented results concern coatings with a chemical composition that has never been proposed before. The present research aims to characterize the effects of nanosilver and nanocopper, dispersed in nanohydroxyapatite coatings and deposited on a new, non-toxic Ti13Zr13Nb alloy, on the physical and mechanical properties of...
-
The structure of 70(2Bi2O3-V2O5) - 30SrBO7 measured with X-ray diffraction and SEM methods
Open Research DataThe structure changes of 70(2Bi2O3-V2O5)-30SrB4O7 glass occurred during increase in temperature was measured by XRD and SEM.
-
Size Exclusion Coupled to Reversed Phase Liquid Chromatography for the Characterization of Cranberry Products
PublicationA combination of solvent extraction, size exclusion purification, and reversed-phase liquid chromatography with UV absorption and fluorescence detection was here used for the determination of flavan-3-ols and related oligomeric compounds in cranberry products. The method relied on robust, simple, and inexpensive instrumental equipment present in most of routine analytical laboratories. Sample extracts in methanol/water/hydrochloric...
-
Development and validation of a method for the simultaneous analysis of fatty acid ethyl esters, ethyl sulfate and ethyl glucuronide in neonatal meconium: application in two cases of alcohol consumption during pregnancy
PublicationAlcohol consumption during pregnancy constitutes one of the leading preventable causes of birth defects and neurodevelopmental disorders in the exposed children. Fatty acid ethyl esters (FAEEs), ethyl glucuronide (EtG) and ethyl sulfate (EtS) have been studied as potential biomarkers of alcohol consumption. However, most analytical approaches proposed for their analysis in meconium samples consist of separated extraction procedures...
-
Preconcentration and Analytical Methods for Determination of Methyl Tert-Butyl Ether and Other Fuel Oxygenates and Their Degradation Products in Environment: A Review
PublicationFuel oxygenates (FOs) are mainly ethers or alcohols which are added to gasoline either to boost the octane number or to make the fuel burning process more "cleaner" with increasing the oxygen content, or to obtain a combination of both effects. FOs are water soluble with high mobility in the environment which presence even at very low concentrations lower the quality of water making it unsafe or unpleasant due to their objectionable...
-
Zirconia ceramics with additions of Alumina for advanced tribological and biomedical applications
PublicationThe results of an investigation on slip cast and sintered Y2O3 (3 wt%)- stabilized ZrO2 with additions of 5, 10, 15 wt% Al2O3 are reported. The surface roughness, porosity and density of the samples were measured. The hardness HRc and Hv, fracture toughness K1C, and friction coefficients were also measured using standard methods. The structural properties of the samples were observed by Scanning Electron Microscopy (SEM). The surface...
-
Simultaneous determination of ibuprofen and its metabolites in complex equine urine matrices by GC-EI-MS in excretion study in view of doping control
PublicationA novel assay for the simultaneous determination of ibuprofen (IBU) and its four probable metabolites, 1-hydroxyibuprofen (1-OH IBU), 2-hydroxyibuprofen (2-OH IBU), 3-hydroxyibuprofen (3-OH IBU) and carboxyibuprofen (CBX IBU) in equine urine samples with the application of Gas Chromatography-Electron Ionization-Mass Spectrometry (GC-EI-MS) has been developed and elaborated. The new approach for sample preparation including minimizing...
-
The Influence of the Depth of Cut in Single-Pass Grinding on the Microstructure and Properties of the C45 Steel Surface Layer
PublicationThe paper contains the results of a metallographic examination and nanoindentation test conducted for the medium carbon structural steel with low content of Mn, Si, Cu, Cr, and Ni after its grinding to a depth ranging from 2 μm to 20 μm, at constant cutting speed (peripheral speed) of vs = 25 ms−1 and constant feed rate of vft = 1 m/min. Applied grinding parameters did not cause the surface layer hardening, which could generate...
-
New achievements in the field of extraction of trace analytes from samples characterized by complex composition of the matrix
PublicationWithout any doubt, the monitoring of compounds present in samples at trace or ultra-trace level usually requires a preliminary step of isolation and/or enrichment of analytes due to the fact that majority of analytical techniques are not sensitive enough for direct determination of trace compounds. On the other hand, sample preparation is considered as crucial part of whole analytical procedures, in particular in samples characterized...
-
Solid phase microextraction: state of the art, opportunities and applications
PublicationSolid phase microextraction is one of the most popular green techniques used for sample preparations in analytical chemistry. It is a simple, rapid, sensitive, and solvent-free technique. Since SPME was first introduced in the early 1990s, there has been an intensification of research in order to elaborate new methodical solutions in many research facilities around the world, which could increase the use of this technique. More...