Filters
total: 6766
-
Catalog
displaying 1000 best results Help
Search results for: THREE ELECTRODE MEASUREMENT
-
N-doped carbon materials as electrodes for highly stable supercapacitors
PublicationThis article reports a strategy to use nitrogen-doped carbon materials as electrodes for supercapacitors. Depending on the carbon precursor, the porous structure is changed with specific surface area reached up to 2270 m2 g−1. The capacitance of carbon materials used as electrodes is related strictly to pore size. The microstructure and nitrogen functionalities enable a high capacitance (327 F g−1) and cycle durability. The nanoporous...
-
In situ transformation boosts the pseudocapacitance of CuNi-MOF via cooperative orientational and electronic governing
PublicationThe disordered arrangement and thereof inferior conductivity of 2D MOF sheets seriously hinder their practical application. Herein, we propose in situ transformation strategy to architect vertically oriented bimetallic CuNi-MOF as a self-supporting electrode, leading to a decuple high specific capacitance of 1262 C g-1 in comparison with the pristine Ni-MOF powder of 114 C g-1 at 2 A g-1. DFT calculations reveal that introduction...
-
Measurement Campaign and Mathematical Model Construction for the Ship Zodiak Magnetic Signature Reproduction
PublicationThe paper presents the partial work done within the framework of the EDA Siramis II project focused on magnetic signature reproduction of ships. Reproduction is understood here as the ability to determine the magnetic anomaly of the local Earth magnetic field in any direction and at any measurement depth due to the presence of the analysed object. The B-91 type hydrographic ship Zodiak was selected as the real case study. The work...
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublicationThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Nondestructive global corrosion measurement using guided wavefield data
PublicationMetallic structures often face degradation, and corrosion ranks among the most prevalent forms of deterioration. Accurate quantification of corrosion is crucial, especially for structures exposed to harsh environmental conditions, such as marine vessels and offshore installations. Because the traditional measurement methods based on scanning by ultrasonic gauge are time-consuming and provide only rough information on the thickness...
-
Evaluation of Praseodymium and Gadolinium Doped Ceria as a Possible Barrier Layer Material for Solid Oxide Cells
PublicationIn this work, nanocrystalline layers based on the Pr, Gd co-doped CeO2 were investigated. For the preparation of thin layers, lowtemperature spray pyrolysis technique was used. Different stoichiometries of the layers were produced for comparison on polished sapphire substrates. The microstructure of the prepared thin layers was studied by scanning electron microscopy (SEM), energydispersive X-ray spectroscopy (EDS) and X-ray diffractometry (XRD)....
-
Impedance of cation-coupled electron transfer reaction: Theoretical description of one pathway process
PublicationIt has been assumed that cation electron coupled charge transfer can be conducted in accordance with two mutually coupled reactions. Using a differential method an expression was introduced which describes the impedance of a cation electron coupled transfer reaction. Also, an electrical equivalent circuit has been defined. The total faradaic impedance is the sum of electron transfer impedance and cation transfer impedance. Issues...
-
Fe local structure in Pt-free nitrogen-modified carbon based electrocatalysts: XAFS study
PublicationThe paper presents a new results on the bonding environment (coordination number and geometry) and on oxidation states of Fe in nitrogen-modified Fe/C composites used as Pt-free catalysts for oxygen reduction in Direct Hydrogen Fuel Cells. Starting from glucose or fructose, two catalysts displaying different electrochemical performance were prepared and studied in the form of pristine powder and thin catalytic layer of electrode...
-
Oxygen biosensor based on carbon nanotubes directly grown on graphitic substrate
PublicationFilms of carbon nanotubes were synthesized on the graphitic substrates by CVD method in the presence of catalyst. Two different catalysts were used, that is nickel and iron, supported on graphitic substrates. The as-obtained nanotubes were analyzed by SEM imaging with EDX and Raman spectroscopy. The results revealed their multi-walled morphology. Free radical reaction was carried out in order to chemically functionalize synthesized...
-
IMPEDANCE MEASUREMENT MODULE FOR GAS SENSORS WITH TEMPERATURE CONDITIONING FEATURE
PublicationThe paper presents an impedance measurement module which is aimed for gas sensor. Sensor’s heater temperature conditioning and modulation feature is available in order to allow implementation of different techniques improving selectivity and sensitivity of gas sensors. The measurement module uses three-parameter sine-fitting technique for impedance measurement. To monitor sensor temperature, the resistance of the sensor’s heater...
-
The AFM topographic measurements of the surface heterogeneity of iron hexacyanoferrate on a steel surface
Open Research DataMeasurements in semi-contact mode. NTEGRA Prima (NT-MDT) device. NSG 01 probe.
-
Tailoring Defects in B, N-Codoped Carbon Nanowalls for Direct Electrochemical Oxidation of Glyphosate and its Metabolites
PublicationTailoring the defects in graphene and its related carbon allotropes has great potential to exploit their enhanced electrochemical properties for energy applications, environmental remediation, and sensing. Vertical graphene, also known as carbon nanowalls (CNWs), exhibits a large surface area, enhanced charge transfer capability, and high defect density, making it suitable for a wide range of emerging applications. However, precise...
-
Functional fluorine-doped tin oxide coating for opto-electrochemical label-free biosensors
PublicationSensors operating in multiple domains, such as optical and electrochemical, offer properties making biosensing more effective than those working in a single domain. To combine such domains in one sensing device, materials offering a certain set of properties are required. Fluorine-doped tin oxide (FTO) thin film is discussed in this work as functional optically for guiding lossy modes and simultaneously electrochemically, i.e....
-
Topography measurement methods evaluation for entire bending-fatigued fracture surfaces of specimens obtained by explosive welding
PublicationIn this paper, the methods of compensation of differences in the results of entire bending-fatigued fracture surface topographies were presented. The roughness evaluation was performed with a focus variation microscope and confocal surface topography measurement techniques. The differences in the ISO 25178 roughness parameters were investigated and procedures for their compensation were studied. It was found that various types...
-
Determination of Sodium Ion Diffusion Coefficient in Tin Sulfide@Carbon Anode Material Using GITT and EIS Techniques
PublicationThe electroanalytical behavior of SnSx (x = 1, 2) encapsulated into a carbon phase was studied using the galvanostatic intermittent titration technique (GITT) and electrochemical impedance spectroscopy (EIS). These techniques are widely utilized in battery systems to investigate the diffusion of alkali metal cations in anode and cathode materials depending on the concentration of ions in the host material. Here, we report different...
-
Ceria Based Protective Coatings for Steel Interconnects Prepared by Spray Pyrolysis
PublicationStainless steels can be used in solid oxide fuel/electrolysis stacks as interconnects. For successful long term operation they require protective coatings, that lower the corrosion rate and block chemical reactions between the interconnect and adjacent layers of the oxygen or the hydrogen electrode. One of the promising coating materials for the hydrogen side is ceria. Using standard sintering techniques, ceria sinters at around...
-
Selection of material for infiltration of non-stoichiometric Sr0.95Ti0.3Fe0.7O3-δ
Open Research DataThe porous electrodes used for the infiltration were prepared from A-site non-stoichiometric Sr0.95Ti0.3Fe0.7O3-δ synthesized by the conventional solid state reaction method. Screen printed electrodes (0.5 cm2) on CGO-20 substrate, were fired at 800 °C for 2 hours in an air atmosphere. Infiltration of the scaffolds was performed by a water-based precursor...
-
Impedance and cyclic voltammetry studies of GPLA electrodes after laser ablation
Open Research DataThe 3D printed GPLA electrodes present a brand new opportunity for electrode material for electrochemical biosensors. In order for the electrodes to be considered viable for electroanalysis studies, the pretreatment procedure must be applied in order to etch PLA matrix and reveal graphene filler. The following dataset presents an approach towards such...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublicationA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
Spatial sensitivity to the conductivity changes of a four electrode probe.
PublicationW artykule rozważana jest czułość przestrzenna, czteropunktowej, liniowej sondy na zmiany przewodności zachodzące w badanym materiale. Otrzymane wyniki wskazują, że czułość może być zarówno dodatnia i ujemna, tzn. wzrost przewodności może prowadzić zarówno do wzrostu lub do spadku mierzonej impedancji. W artykule rozważane są materiały zarówno izotropowe jak i anizotropowe. Uzyskane wyniki pozwalają wyjaśnić dlaczego niektóre...
-
OPTICAL STRAIN MEASUREMENT OF CONCRETE VERSUS MANUAL EXTENSOMETER MEASUREMENT BASED ON THE TEST RC DEEP BEAM IN A COMPLEX STATE OF STRESS
PublicationThe purpose of this study is to compare the strain measurement techniques of concrete in R-C element subjected to the monotonic load up to the failure. In the analysis manual extensometer methods of measurements and the optical system ARAMIS for non-contact three-dimensional measurements of deformation was used. The test sample was a cantilever deep beam loaded throughout the depth which was a part of the reinforced concrete deep...
-
Low-coherence method of hematocrit measurement
PublicationDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
On-line measurement of wood surface smoothness
PublicationThe latest progress in the field of optics and microelectronics resulted in development of new generation vision systems capable of scanning surface topography with very high sampling frequencies. The blue color of illuminating light as well as novel systems for controlling ultra-thin laser line thickness allows measurement of the porous surface of wood with a triangulation method. Three alternative sensors were tested here in...
-
3D polypyrrole structures as a sensing material for glucose detection
PublicationIn this work, 3D polypyrrole (PPy) structures as material for glucose detection is proposed. Polypyrrole was electrochemically polymerized on platinum screen-printed electrode from an aqueous solution of lithium perchlorate and pyrrole. The growth mechanism of such PPy structures was studied by ex-situ scanning electron microscopy. Preliminary studies show that studied here PPy film is a good candidate as a sensing material for...
-
AFM images of the platinum (111) single crystal surface as delivered, without the polishing treatment
Open Research DataPlatinum (111) single crystal surface images as delivered, without polishing treatment. Topographic measurements in contact mode. NTEGRA Prima (NT-MDT) device. CSG probe 10.
-
Gold nanocubic structures functionalization with organic layers
Open Research DataThis dataset contains the XPS spectra obtained for gold nanocubes (AuNC), which were deposited at the gold electrode surface and dried. The AuNC's were first functionalized with either cysteamine in EtOH or mercaptopropionic acid in EtOH. The concentration of these compounds was 20 mM. The interaction of the functionalized with the AuNC surface was...
-
Simple Measurement Method for Resistive Sensors Based on ADCs of Microcontrollers
PublicationA new, complete measurement method for resistance measurement of resistive sensors for systems based on microcontrollers equipped with analog-to-digital converters (ADCs) is proposed. The interface circuit consists of only four resistors, including a resistive sensor and a reference resistor, connected directly to the microcontroller pins. It is activated only during measurements, which significantly reduces power consumption....
-
A measurement system for children endurance tests
PublicationThere are a lot of ethical problems concerning the use of invasive methods for the measurement of a child's body response to physical exercise and physical training. The alternative is are non-invasive methods like ergospirometry or NIRS. The article presents a measurement system dedicated for children endurance tests, composed of a few non-invasive measurement modules, including a temperature measurement module. Temperature is...
-
Electrochemical simulation of metabolic reduction and conjugation reactions of unsymmetrical bisacridine antitumor agents, C-2028 and C-2053
PublicationElectrochemistry (EC) coupled with analysis techniques such as liquid chromatography (LC) and mass spectrometry (MS) has been developed as a powerful tool for drug metabolism simulation. The application of EC in metabolic studies is particularly favourable due to the low matrix contribution compared to in vitro or in vivo biological models. In this paper, the EC(/LC)/MS system was applied to simulate phase I metabolism of the representative...
-
Electrocatalytic performance of oxygen-activated carbon fibre felt anodes mediating degradation mechanism of acetaminophen in aqueous environments
PublicationCarbon felts are flexible and scalable, have high specific areas, and are highly conductive materials that fit the requirements for both anodes and cathodes in advanced electrocatalytic processes. Advanced oxidative modi- fication processes (thermal, chemical, and plasma-chemical) were applied to carbon felt anodes to enhance their efficiency towards electro-oxidation. The modification of the porous anodes results in increased...
-
Uncertainty of mass flow measurement using centric and eccentric orifice for Reynolds number in the range 10,000 ≤ Re ≤ 20,000
PublicationThe article analyses the impact of the Reynolds number on the estimated uncertainty of the mass flow rate measurement using an orifice plate. The objects of the research were two types of orifices: centric (ISA) and eccentric, with the diameter ratio β = 0.5. Studies were performed by Monte Carlo simulation and experiments for Reynolds numbers in the range 10,000 ≤ Re ≤ 20,000. The obtained results have shown that for both orifice...
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublicationAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublicationDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Composites of tin oxide and different carbonaceous materials as negative electrodes in lithium-ion batteries
PublicationAbstract Tin and tin oxide have been considered as suitable materials with high theoretical capacity for lithium ion batteries. Their low cost, high safety and other technical benefits placed them as promising replacements for graphite negative electrodes. The problem to overcome with tin oxide, as well as with other metallic materials, is high volume changes during alloying/dealloying, subsequent pulverization, delamination from...
-
Chestnut-Derived Activated Carbon as a Prospective Material for Energy Storage
PublicationIn this work, we present the preparation and characterization of biomass-derived activatedcarbon (AC) in view of its application as electrode material for electrochemical capacitors. Porouscarbons are prepared by pyrolysis of chestnut seeds and subsequent activation of the obtainedbiochar. We investigate here two activation methods, namely, physical by CO2and chemical usingKOH. Morphology, structure and specific surface area (SSA)...
-
Capacitance Enhancement by Incorporation of Functionalised Carbon Nanotubes into Poly(3,4-Ethylenedioxythiophene)/Graphene Oxide Composites
PublicationThis paper reports on the role of oxidised carbon nanotubes (oxMWCNTs) present in poly-3,4-ethylenedioxytiophene (PEDOT)/graphene oxide (GOx) composite. The final ternary composites (pEDOT/GOx/oxMWCNTs) are synthesised by an electrodeposition process from the suspension-containing monomer, oxidised carbon nanotubes and graphene oxide. Dissociated functional groups on the surface of graphene oxide play a role of counter-ions for the...
-
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 16. Synthesis of 25, 26, 27, 28-tetrakis(piperidinethiocarbonylmethylene)-p-tert-butylcalix[4]arene and its interaction with metal ions
PublicationThe synthesis, characterisation and X-ray crystal structures of p-tert-butyl-calix[4]arenethioamide L and its complex with lead L-Pb2+ is reported. The cation-binding properties in solution have been assessed by liquid-liquid extraction of the metal picrates from water into dichloromethane and by stability constants determination in acetonitrile using UV-absorption spectrophotometry or potentiometry. The compound was used as active...
-
Dynamic impedance measurements of the Direct Methanol Fuel Cell cathode at various operating temperatures
PublicationThis article discusses the application of impedance analysis for diagnosing the cathode of a direct methanol fuel cell at various operating temperatures. The Dynamic Electrochemical Impedance Spectroscopy technique coupled with a linear current scan was applied for this purpose. This technique allowed the observation of changes in the cathode's properties in the fuel cell operating under real working conditions. An equivalent model...
-
Integrated Three-Level Dual-Phase Inverter
PublicationIn view of reducing the number of inverter legs that provide dual-phase, three-level output voltages (as may be needed in an uninterruptible power supply), and that also provide a wide range of output frequencies (as needed in an advanced motor drive system with wide speed ranges), a three-level, dual-phase inverter topology is presented in this paper. Its three-level attribute was based on the F-type inverter topological concept,...
-
Grzegorz Lentka dr hab. inż.
PeopleGrzegorz Lentka obtained his MSc title in electronics, specialization Measurement Systems at Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics in 1996. He obtained the PhD title in 2003 and habilitation in 2014, respectively. Currently he is an professor in Department of Metrology and Optoelectronics. His main scientific interests are focused on digital signal processing for metrology,...
-
MEASUREMENT TECHNIQUES
Journals -
Measurement: Sensors
Journals -
MEASUREMENT & CONTROL
Journals -
Reducing the Uncertainty of the Moving Object Location Measurement with the Method of Quasi-Multiple Measurement in GNSS Technology in Symmetrical Arrangement
PublicationThe article presents a solution to the problem of limited accuracy of dynamic measurements performed with GNSS receivers. The proposed measurement method is a response to the needs related to the assessment of the measurement uncertainty of the position of the track axis of the rail transport line. However, the problem of reducing the measurement uncertainty is universal for many different situations where high accuracy of positioning...
-
Impact of probability distribution on the uncertainty of resistance measurement
PublicationThe paper presents studies on the influence of probability distributions on the expanded uncertainty of the resistance measurement. Choosing the correct probability distribution is very important to estimate of measurement uncertainty. The paper presents the results of analysis of the resistance measurement uncertainty using the technical method of resistance: 100 G. The analysis of the uncertainty...
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublicationRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Aleksandra Parteka dr hab. inż.
PeopleAbout me: I am an associate professor and head of doctoral studies at the Faculty of Management and Economics, Gdansk University of Technology (GdanskTech, Poland). I got my MSc degree in Economics from Gdansk University of Technology (2003) and Universita’ Politecnica delle Marche (2005), as well as MA degree in Contemporary European Studies from Sussex University (2006, with distinction). I received my PhD in Economics...
-
AFM and SSRM investiagtion of carbon nanowalls properties
Open Research DataStructures with limited dimensionality are of great interest in modern nanotechnology. The properties of these objects are used, among others, for the construction of modern displays or as a base for quantum computers. Carbon nanowalls, which are the subject of the imaging results contained in this collection, are also considered interesting building...
-
Distance measurement errors in silent FM-CW sonar with matched filtering
PublicationThe secretiveness of sonar operation can be achieved by using continuous frequency-modulated sounding signalswith reduced power and significantly prolonged repeat time. The application of matched filtration in the sonarreceiver provides optimal conditions for detection against the background of white noise and reverberation, and avery good resolution of distance measurements of motionless targets. The article shows that target...