Filters
total: 3990
-
Catalog
displaying 1000 best results Help
Search results for: MEASUREMENT: REFERENCE TYRE:
-
New First - Path Detector for LTE Positioning Reference Signals
PublicationIn today's world, where positioning applications reached a huge popularity and became virtually ubiquitous, there is a strong need for determining a device location as accurately as possible. A particularly important role in positioning play cellular networks, such as Long Term Evolution (LTE). In the LTE Observed Time Difference of Arrival (OTDOA) positioning method, precision of device location estimation depends on accuracy...
-
Uncertainty of the liquid mass flow measurement using the orifice plate
PublicationThe article presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. This subject is essential because of the widespread use of this type of flow meters. Not only the quantitative estimation but also the qualitative results of those measurements are important. To achieve these results the authors of the paper propose to use the theory of uncertainty. The article shows the analysis of the...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublicationThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
AN ORIGINAL APPROACH IN THE FIELD OF PREPARATION REFERENCE MATERIALS OF VOLATILE ANALYTES
PublicationStandard gas mixtures (SGM) are indispensable reference materials for ensuring the reliability of analytical work. Reference materials are an excellent tool for the quality control and assurance of analytical results. Standard gas mixtures are unique among reference materials. The rapid progress of SGM production is connected with the instability of gaseous analytes which make them difficult to obtain. The use of standards with...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublicationThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Measurement Campaign and Mathematical Model Construction for the Ship Zodiak Magnetic Signature Reproduction
PublicationThe paper presents the partial work done within the framework of the EDA Siramis II project focused on magnetic signature reproduction of ships. Reproduction is understood here as the ability to determine the magnetic anomaly of the local Earth magnetic field in any direction and at any measurement depth due to the presence of the analysed object. The B-91 type hydrographic ship Zodiak was selected as the real case study. The work...
-
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Laser reflectance interferometry system with a 405 nm laser diode for in-situ measurement of CVD diamond thickness
PublicationIn situ monitoring of the thickness of thin diamond films during technological processes is important because it allows better control of deposition time and deeper understanding of deposition kinetics. One of the widely used techniques is laser reflectance interferometry (LRI) which enables non-contact measurement during CVD deposition. The authors have built a novel LRI system with a 405 nm laser diode which achieves better...
-
Accuracy Analysis of Determination the Vertical Displacements in Unstable Reference System
PublicationMeasurements of horizontal and vertical displacements are carried out mostly based on reference points identified as fixed. In surveying practice there may be some situations in which there is not possible to perform the measurements with reference to stable points or the difficulties in identification of points’ stability may arise. Accuracy analysis based on the covariance matrices have a special role in this process. In presented...
-
REFERENCE SERVICES REVIEW
Journals -
Reference Series in Phytochemistry
Journals -
Strength characteristics of tyre chips-sand mixtures.
PublicationBadania w aparacie trójosiowego ściskania przy różnej zawartości wagowej kawałków zużytych opon oraz różnym ich ułożeniu w próbce piasku. Badania prowadzono przy dowolnym ułożeniu tych elementów, umieszczeniu ich poziomo oraz w systemie mieszanym. Wyznaczono optymalną zawartość kawałków opon w próbce piasku, przy której występowała maksymalna wytrzymałość na ściskanie.
-
Investigation of the impact of ITRF2014/IGS14 on the positions of the reference stations in Europe
PublicationIn January 2017, the new realization of the International Terrestrial Reference Frame (ITRF) – ITRF2014, was released. Besides the higher accuracy and consistency of the new frame, an entirely new element – the post seismic deformation - was included. Moreover, the definition of the fundamental points has also been changed. All changes related to the new reference frame haveconsequences in the precise positioning using GNSS observations....
-
Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer
PublicationThe discords concerning the measurement uncertainty evaluation in the Guide to the Expressing of Uncertainty in Measurement (GUM) and its Supplement 1 are considered. To overcome these discords, the authors of the paper propose to use the kurtosis method and the law of the propagation of the expanded uncertainty. Using the example of the goniometer calibration, the features of accounting for the distribution laws of input quantities...
-
Topography measurement methods evaluation for entire bending-fatigued fracture surfaces of specimens obtained by explosive welding
PublicationIn this paper, the methods of compensation of differences in the results of entire bending-fatigued fracture surface topographies were presented. The roughness evaluation was performed with a focus variation microscope and confocal surface topography measurement techniques. The differences in the ISO 25178 roughness parameters were investigated and procedures for their compensation were studied. It was found that various types...
-
Low-coherence method of hematocrit measurement
PublicationDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
A measurement system for children endurance tests
PublicationThere are a lot of ethical problems concerning the use of invasive methods for the measurement of a child's body response to physical exercise and physical training. The alternative is are non-invasive methods like ergospirometry or NIRS. The article presents a measurement system dedicated for children endurance tests, composed of a few non-invasive measurement modules, including a temperature measurement module. Temperature is...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublicationAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Effectiveness of Concrete Reinforcement with Recycled Tyre Steel Fibres
Publication -
Exploration of optical fibres as a carrier for new benzene and toluene matrix-free reference materials
PublicationTo meet high expectations concerning precision and accuracy of reference materials, preparation of matrixfree reference materials using thermal decomposition-gas chromatography-mass spectrometry (TD-GC-MS) was proposed in this study. In the paper, the results obtained in preparation of the new reference materials for benzene and toluene are presented, based on the thermal decomposition technique of compounds chemically bound to...
-
MEASUREMENT TECHNIQUES
Journals -
Measurement: Sensors
Journals -
MEASUREMENT & CONTROL
Journals -
Uncertainty of mass flow measurement using centric and eccentric orifice for Reynolds number in the range 10,000 ≤ Re ≤ 20,000
PublicationThe article analyses the impact of the Reynolds number on the estimated uncertainty of the mass flow rate measurement using an orifice plate. The objects of the research were two types of orifices: centric (ISA) and eccentric, with the diameter ratio β = 0.5. Studies were performed by Monte Carlo simulation and experiments for Reynolds numbers in the range 10,000 ≤ Re ≤ 20,000. The obtained results have shown that for both orifice...
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublicationAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublicationDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Identification of Unstable Reference Points and Estimation of Displacements Using Squared Msplit Estimation
PublicationThe article presents a new version of the method for estimating parameters in a split functional model, which enables the determination of displacements of geodetic network points with constrained datum. The main aim of the study is to present theoretical foundations of Msplit CD estimation and its basic properties and possible applications. Particular attention was paid to the efficacy of the method in the context of geodetic...
-
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
PublicationIn this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations....
-
The Use of Free Adjustment and Msplit-Estimation for Determination of the Vertical Displacements in Unstable Reference System
PublicationThe problem of the determining of the displacements of engineering objects and their surroundings is the current and important issue in the field of engineering geodesy. Most control measurements are made in relation to reference points (stable points). On the other hand, sometimes it happens that it is not possible perform the measurements with reference to the stable points or identification of stable points is difficult. Therefore,...
-
Reducing the Uncertainty of the Moving Object Location Measurement with the Method of Quasi-Multiple Measurement in GNSS Technology in Symmetrical Arrangement
PublicationThe article presents a solution to the problem of limited accuracy of dynamic measurements performed with GNSS receivers. The proposed measurement method is a response to the needs related to the assessment of the measurement uncertainty of the position of the track axis of the rail transport line. However, the problem of reducing the measurement uncertainty is universal for many different situations where high accuracy of positioning...
-
The application of TD-GC-FID technique for production of matrix-free reference materials
PublicationIn the last few years particular pressure is exerted on finding new analytical methods which would provide real possibilities of monitoring and control of the state of the environment. Intensive development of analytical techniques for measurements of gaseous media and the negative effects of BTX compounds make it necessary to produce new gaseous reference materials. To prepare the appropriate non- matrix reference material thermal...
-
Impact of probability distribution on the uncertainty of resistance measurement
PublicationThe paper presents studies on the influence of probability distributions on the expanded uncertainty of the resistance measurement. Choosing the correct probability distribution is very important to estimate of measurement uncertainty. The paper presents the results of analysis of the resistance measurement uncertainty using the technical method of resistance: 100 G. The analysis of the uncertainty...
-
Self-optimizing narrowband interference canceller - can reference signal help?
PublicationSONIC (Self-Optimizing Narrowband Interference Canceller) is an acronym of the recently proposed active noise control algorithm with interesting adaptivity and robustness properties. SONIC is a purely feedback controller, capable of rejecting nonstationary sinusoidal disturbances (with time-varying amplitudes and/or frequencies) in the presence of plant (secondary path) uncertainties. We show that even though SONIC can work reliably...
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublicationRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Determination of vertical displacements by using the hydrostatic levelling systems with the variable location of the reference sensor,
PublicationAbstract: In this paper, the author proposed a new method for determination of vertical displacements with the use of hydrostatic levelling systems. The traditional method of hydrostatic levelling uses a rule in which a position of reference sensor is stable. This assumption was not adapted in the proposed method. Regarding the issue mentioned above, the reference sensor is treated in the same way as the others sensors that measure...
-
Certified Reference Material - as a necessary tool for the quality control and quality assurance of measurements
PublicationReference materials are necessary to control and ensure the quality of the measurements. The demand for analytical information on the composition of different material objects makes it necessary to produce an even wider range of materials.
-
New matrix-free reference material for ethene in the form of optical fibres
PublicationReference materials are indispensable in the qualitycontrol and quality assurance of analytical measurements. Onenovel approach to the generation of standard gaseous mixturesof toxic, reactive, volatile, labile, and malodorous substancesinvolves thermal decomposition or rearrangement, under definedtemperature conditions, of compounds immobilized, bychemical bonding, on the surface of an appropriate carrier torelease specific amounts...
-
USE OF LANGMUIR PROBE IN DIESEL ENGINE DIAGNOSTIC RESEARCH Part I MEASUREMENT TECHNOLOGY. - Part 1 : MEASUREMENT TECHNOLOGY
PublicationIn the paper, the basic assumptions of diesel engine cylinder system's diagnosing method, based on observation of emerging and moving electric charges of ionized gas in the combustion workspaces, using Langmuir's probe. In the first part of the paper, only the technology of the measurement and results of the preliminary diagnostic tests of laboratory engine Farymann Diesel D10 were presented. The primary purpose of the research...
-
Grzegorz Lentka dr hab. inż.
PeopleGrzegorz Lentka obtained his MSc title in electronics, specialization Measurement Systems at Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics in 1996. He obtained the PhD title in 2003 and habilitation in 2014, respectively. Currently he is an professor in Department of Metrology and Optoelectronics. His main scientific interests are focused on digital signal processing for metrology,...
-
Development of potential candidate reference materials for drugs in bottom sediment, cod and herring tissues
PublicationRegular use of a reference material and participation in a proficiency testing program can improve the reliability of analytical data. This paper presents the preparation of candidate reference materials for the drugs metoprolol, propranolol, carbamazepine, naproxen, and acenocoumarol in freshwater bottom sediment and cod and herring tissues. These reference materials are not available commercially. Drugs (between 7 ng/g and 32...
-
Distance measurement errors in silent FM-CW sonar with matched filtering
PublicationThe secretiveness of sonar operation can be achieved by using continuous frequency-modulated sounding signalswith reduced power and significantly prolonged repeat time. The application of matched filtration in the sonarreceiver provides optimal conditions for detection against the background of white noise and reverberation, and avery good resolution of distance measurements of motionless targets. The article shows that target...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
DiSTFAG method robust to gross errors in monitoring displacements and strains in unstable reference systems
PublicationThe DiSTFA method (Displacements and Strains using Transformation and Free Adjustment) was presented in Kamiński (2009). The method has been developed for the determination of displacements and strains of engineering objects in unstable reference systems, as well as for examining the stability of reference points. The DiSTFAG (Gross errors) method presented in the paper is the extension of the DiSTFA method making it robust to...
-
Characteristics of tyre chips-sand mixtures from triaxial tests
PublicationAnaliza parametrów wytrzymałościowych i odkształcalności mieszanek piasku i kawałków zużytych opon. Powtórne użycie tego materiału, odpowiednio przetworzonego na skrawki i elementy o kształcie kołowym pozwala po odpowiednim zmieszaniu z gruntem niespoistym na uzyskanie materiału o zwiększonej wytrzymałości na ścinanie zachowywanej również przy dużych odkształceniach. Analizowano mieszanki o różnej zawartości opon przy naprężeniach...
-
Evaluation of recycled tyre steel fibres adhesion to cement matrix
Publication -
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
A concept of measurement system based on the Z-Wave standard
PublicationIn the paper a new concept of measurement system based on the Z-Wave standard is presented. This standard is dedicated to use mainly in home automation systems, but its properties enable to use it in dispersed measurement systems and support wireless communication between measurement nodes in a mesh-type network. In the paper basic metrological aspects of the Z-Wave standard and an example of impedance measurement system are discussed.
-
Reference FEM model for SHM system of cable-stayed bridge in Rzeszów
PublicationThe paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Scalable Measurement System for Multiple Impedance Gas Sensors
PublicationAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...