Search results for: SENSOR NETWORK.
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 30 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 150 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 160 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 100 um (serie 1)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Distance measurement with the low coherent interferometer with silver mirror (the source wavelegth 1310 nm) - 50 um (serie 2)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Silicon microcantilever with impedance sensor
Open Research DataThe issue of microelectromechanical systems (MEMS) [1] has been enjoying popularity and interest since the 90s of the 20th century. Microcells are one of the simplest devices of this type, but they can be widely used in sensors. There are reports on the possibility of using this type of sensors in the context of such important issues as diagnostics...
-
Optical method supported by machine learning for urinary tract infection detection and urosepsis risk assessment
PublicationThe study presents an optical method supported by machine learning for discriminating urinary tract infections from an infection capable of causing urosepsis. The method comprises spectra of spectroscopy measurement of artificial urine samples with bacteria from solid cultures of clinical E. coli strains. To provide a reliable classification of results assistance of 27 algorithms was tested. We proved that is possible to obtain...
-
Remote Health Monitoring of Wind Turbines Employing Vibroacoustic Transducers and Autoencoders
PublicationImplementation of remote monitoring technology for real wind turbine structures designed to detect potential sources of failure is described. An innovative multi-axis contactless acoustic sensor measuring acoustic intensity as well as previously known accelerometers were used for this purpose. Signal processing methods were proposed, including feature extraction and data analysis. Two strategies were examined: Mel Frequency Cepstral...
-
An adaptive approach to non-destructive evaluation (NDE) of cast irons containing precipitated graphite particles with the help of magnetoacoustic emission
PublicationPhysical properties of cast irons strongly depend on both their microstructure and the presence of casting defects. The paper analyses the possibility of application of magnetoacoustic emission (MAE) for nondestructive detection of flawed cast iron components. The investigated samples containing dross, chunky graphite and lamellar graphite were compared with the reference, flawless, spheroidal cast iron sample. The optimisation...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublicationResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublicationThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
Asynchronous Networked Estimation System for Continuous Time Stochastic Processes
PublicationIn this paper we examine an asynchronous networked estimation system for state estimation of continuous time stochastic processes. Such a system is comprised of several estimation nodes connected using a possibly incomplete communication graph. Each of the nodes uses a Kalman filter algorithm and data from a local sensor to compute local state estimates of the process under observation. It also performs data fusion of local estimates...
-
Fiber optic microsphere with a ZnO thin film for potential application in a refractive index sensor – theoretical study
PublicationOptical fiber sensors of refractive index play an important role in analysis of biological and chemical samples. This work presents a theoretical investigation of spectral response of a fiber optic microsphere with a zinc oxide (ZnO) thin film deposited on the surface and evaluates the prospect of using such a structure for refractive index sensing. A microsphere is fabricated by an optical fiber tapering method on the base of...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublicationIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
High Dynamic Range Microwave Displacement and Rotation Sensors Based on the Phase of Transmission in Groove Gap Waveguide Technology
PublicationThis research is focused on the design and realization of displacement sensors in gap waveguide technology. It is shown that with a small but fundamental change in the structure of a conventional gap waveguide, a linear displacement can be sensed. To this end, a unique feature of gap waveguides, i.e. the fact that no electrical connection between the top and bottom parts of the gap waveguide is required, is used. It is further shown...
-
Operational Enhancement of Numerical Weather Prediction with Data from Real-time Satellite Images
PublicationNumerical weather prediction (NWP) is a rapidly expanding field of science, which is related to meteorology, remote sensing and computer science. Authors present methods of enhancing WRF EMS (Weather Research and Forecast Environmental Modeling System) weather prediction system using data from satellites equipped with AMSU sensor (Advanced Microwave Sounding Unit). The data is acquired with Department of Geoinformatics’ ground...
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 194
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 194, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 192
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 192, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 191
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 191, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 193
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 193, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Sea surface temperature in the Baltic Sea derived from Landsat 8 satellite data - path 190
Open Research DataThe data set contains high resolution sea surface temperature (SST) maps estimated from Landsat 8 Level 1 Thermal Infrared Sensor (TIRS) data using NLSST algorithm. SST was calculated only for granules (185 x 180 km) from satellite path number 190, that covered at least 2000 km2 of the cloud-free area of the Baltic Sea.
-
Engineering boron and nitrogen codoped carbon nanoarchitectures to tailor molecularly imprinted polymers for PFOS determination
PublicationPer- and polyfluoroalkyl substances (PFAS) have gained significant attention as emerging contaminants due to their persistence, abundance, and adverse health effects. Consequently, the urgent need for ubiquitous and effective sensors capable of detecting and quantifying PFAS in complex environmental samples has become a priority. In this study, we present the development of an ultrasensitive molecularly imprinted polymer (MIP)...
-
Design of novel highly sensitive sensors for crack detection in metal surfaces: theoretical foundation and experimental validation
PublicationThe application of different types of microwave resonators for sensing cracks in metallic structures has been subject of many studies. While most studies have been focused on improving the sensitivity of planar crack sensors, the theoretical foundation of the topic has not been treated in much detail. The major objective of this study is to perform an exhaustive study of the principles and theoretical foundations for crack sensing...
-
Measurements and visualization of sound field distribution around organ pipe
PublicationMeasurements and visualization of acoustic field around an organ pipe are presented. Sound intensity technique was applied for this purpose. Measurements were performed in free field. The organ pipe was activated with a constant air flow, produced by an external compressor, aimed at obtaining long-term steady state responses of generated acoustic signal. Sound energy distribution was measured in a defined fixed grid of points...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Sensors in River Information Services of the Odra River in Poland: Current State and Planned Extension
PublicationAccording to adopted in 2016 by the polish Council of Ministers assumptions for the plans for the progress of inland waterways in Poland for the years 2016-2020, with the perspective of 2030, assume that by 2030 Odra along its entire length and the Vistula from Warsaw to Gdansk, they will have become international shipping routes, which will be implemented system of River Information Services (RIS). Aspects of RIS sensor application...
-
CMOS implementation of an analogue median filter for image processing in real time
PublicationAn analogue median filter, realised in a 0.35 μm CMOS technology, is presented in this paper. The key advantages of the filter are: high speed of image processing (50 frames per second), low-power operation (below 1.25 mW under 3.3 V supply) and relatively high accuracy of signal processing. The presented filter is a part of an integrated circuit for image processing (a vision chip), containing: a photo-sensor matrix, a set of...
-
Characteristics of an image sensor with early-vision processing fabricated in standard 0.35 µm CMOS technology
PublicationThe article presents measurement results of prototype integrated circuits for acquisition and processing of images in real time. In order to verify a new concept of circuit solutions of analogue image processors, experimental integrated circuits were fabricated. The integrated circuits, designed in a standard 0.35 µm CMOS technology, contain the image sensor and analogue processors that perform low-level convolution-based image...
-
Label‐free optical detection of cyclosporine in biological fluids
PublicationIn this paper, a spectroscopic method for determination of cyclosporine concentrations in biological fluids is presented. Blood plasma and hemoglobin solutions are chosen for the experiment. For various cyclosporine concentrations in blood plasma and hemoglobin, absorbance measurements in spectra range from 600 to 1100 nm are performed. The measurement results are analyzed by the use of a dedicated algorithm. The obtained data...
-
Distance measurement by the low coherent interferometer
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1560 nm, an optical spectrum analyzer and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Simulation of signal acquisition from a rotary flowmeter
Open Research DataThe dataset contains results of simulation measuring the flow of homogeneous substances by rotational flow meter: a moment of impulse at the output of flow meter, time between successive pulses, number of pulses counted from standard generator and relative error of measurement.
-
ANN for human pose estimation in low resolution depth images
PublicationThe paper presents an approach to localize human body joints in 3D coordinates based on a single low resolution depth image. First a framework to generate a database of 80k realistic depth images from a 3D body model is described. Then data preprocessing and normalization procedure, and DNN and MLP artificial neural networks architectures and training are presented. The robustness against camera distance and image noise is analysed....
-
Optimization of a Fabry-Perot Sensing Interferometer design for an optical fiber sensor of hematocrit level
PublicationContinuous measurement of the hemato crit level in blo o d can p otentially b e p erformed using optical bre sensors. The FabryPerot interferometric sensors are a promising candidate in this application. The most imp ortant step in the design of the sensor is design of the sensing interferometer. Adequate cavity length and high interference contrast are two most imp ortant requirements in this application. The design metho d of...
-
System setup and software for cyclic, staircase and square wave voltammetry measurements
PublicationHardware dedicated for electrochemical measurement sometimes does not allow performing certain voltammetry experiments. Staircase and square wave voltammetry, techniques which have many advantages comparing with standard voltammetric techniques, are rarely implemented in software controlling electrochemical measuring equipment. These methods, however, can be relatively easy realized with some addition...
-
Przegląd metod pomiaru temperatury przewodów linii napowietrznych wysokiego napięcia
PublicationW artykule przedstawiono przegląd metod pomiaru temperatury napowietrznych linii wysokiego napięcia stosowanych w celu poprawy niezawodności eksploatacji i w celu wyznaczania dopuszczalnej obciążalności linii. Omówiono system DOL dynamicznej obciążalności linii oraz bezdotykowe metody pomiaru temperatury: pomiar z użyciem pasywnych czujników SAW (ang. Surface acoustic wave sensor), DTS (distributed temperature sensing) z wykorzystaniem...
-
Using differential pressure sensor to measure nitrous oxide level in a tank
PublicationA method for measuring the level of liquid nitrous oxide oxidizer in a hybrid rocket motor oxidizer tank is proposed. Presented approach is more accurate than the most commonly used method of this measurement, which employs weighting of the whole sounding rocket or an oxidizer tank. In our solution we use a differential pressure sensor to measure the change of pressure at the bottom of an oxidizer tank in comparison to the pressure...
-
FFT analysis of temperature modulated semiconductor gas sensor response for the prediction of ammonia concentration under humidity interference
PublicationThe increasing environmental contamination forces the need to design reliable devices for detecting of the volatile compounds present in the air. For this purpose semiconductor gas sensors, which have been widely used for years, are often utilized. Although they have many advantages such as low price and quite long life time, they still lack of long term stability and selectivity. Namely, environmental conditions have significant...
-
Investigation of sweet substances of different molecular structure by potentiometric taste sensor with all solid state electrodes
PublicationA five channel potentiometric taste sensor consisting of an array of All Solid State Electrodes (ASSESs) with different lipid-polymer membranes has been developed. The electrodes are constructed of glassy carbon discs with electrochemically deposited poly(3,4-ethylenedioxythiophene) (PEDOT) acting as ion to electron transducer. The outer layer of the electrode is lipid-polymer membrane. Lipid substances immobilized in PVC membranes...
-
Acoustic emission studies of the 7075 aluminium alloy pitting corrosion process
Open Research DataThe dataset contains the cyclic polarization studies and corresponding acoustic emission measurements, revealing the pitting corrosion process of the passive layer at the surface of the 7075 aluminum alloy in the borate buffer with different chloride ions concentrations, in the range between 0.05 and 25 mM.
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Acquisition and indexing of RGB-D recordings for facial expressions and emotion recognition
PublicationIn this paper KinectRecorder comprehensive tool is described which provides for convenient and fast acquisition, indexing and storing of RGB-D video streams from Microsoft Kinect sensor. The application is especially useful as a supporting tool for creation of fully indexed databases of facial expressions and emotions that can be further used for learning and testing of emotion recognition algorithms for affect-aware applications....
-
Measurements of the optical and thermal properties of the 2D black phosphorus coating
PublicationBlack phosphorus is a 2D material, which properties are still being discovered. In this paper, the sensitivity to the temperature of a few-layer black phosphorus coating deposited, on the surface of a microsphere-based fiber-optic sensor, by a dip-coating method is presented. The coating was investigated after 2, 3, and 5 deposition cycles and during temperature growth from 50 °C to 300 °C in an interferometric setup. The intensity...
-
Horizontally-split-drain MAGFET - a highly sensitive magnetic field sensor
PublicationWe propose a novel magnetic field sensitive semiconductor device, viz., Horizontally-Split-Drain Magnetic-Field Sensitive Field-Effect Transistor (HSDMAGFET) which can be used to measure or detect steady or variable magnetic fields. Operating principle of the transistor is based on one of the galvanomagnetic phenomena and a Gradual Channel Detachment Effect (GCDE) and is very similar to that of Popovic and Baltes's SDMAGFET. The...
-
Excitation-independent constant conductance isfet driver
PublicationA new constant conductance driver for ISFETs sensors has been developed. The proposed circuit maintains the sensor operating point at constant drain-source conductance. The combination of a simple, self-balancing resistance bridge and the subtraction half (or similar fraction) of source-drain voltage from the gate-source voltage provides the independence of output signal from current and voltage drivers instability. The use of...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublicationPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Corrosion monitoring by harmonic analysis in aqueous environments
PublicationThis paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at...
-
Evaluation of sound event detection, classification and localization in the presence of background noise for acoustic surveillance of hazardous situations
PublicationAn evaluation of the sound event detection, classification and localization of hazardous acoustic events in the presence of background noise of different types and changing intensities is presented. The methods for separating foreground events from the acoustic background are introduced. The classifier, based on a Support Vector Machine algorithm, is described. The set of features and samples used for the training of the classifier...
-
Comparison of Evaluation of Air Odour Quality in Vicinity of Petroleum Plant Using a Prototype of Electronic Nose Instrument and Fast GC Technique
PublicationThe paper presents the results of investigation on classification of the ambient air samples collected in a vicinity of the LOTOS Group S.A. petroleum plant with respect to odour. The investigations were carried out with an electronic nose prototype and a commercial electronic nose of Fast GC-type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and a photoionization sensor of PID-type....