Search results for: active power
-
Active Power Quality Controllers
PublicationDynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...
-
A simple modular active power electronic transformer
Publication -
A boost topology active power factor corrector.
PublicationPrzedstawiono układ analogowego aktywnego korektora zbudowanego na układzie scalonym kontrolera PWM oraz tranzystorem MOS jako okresowo przełączonym kluczem. Układ korektora zapewnia pobór prądu z sieci energetycznej w postaci przebiegu prawie sinusoidalnego o małych zniekształceniach i w fazie z sinusoidalnym napięciem sieci.
-
Design of a simple modular active power electronic transformer
Publication -
Predictive control system of the shunt active power filter
Publication -
New control system of the shunt active power filter
Publication -
A filter bank solution for active power filter control algorithms
PublicationThb paper describes the proposed active power fiIter (APF) with a new control circuit based on an algorithm using ufilter bank and a harmonic predictor. The conirol circuit was realized using the digiiaI signor processor ADSP-21065L and FPGA circuiL In the proposed circuit transient performunee of APF is improved The active power fdter circuil has been built and teste6 and some illustrative, experimental results are uIso presented...
-
Design and evaluation of a base module of active power electronic transformer
PublicationThis paper presents an active power electronic transformer (APET) based on modular structure. The proposed three phase APET consists of at least three base modules (BM). The input/output stage of the BM is based on half-bridge sub modules. The isolation stage includes a medium frequency transformer and is realized as a dual half-bridge. The paper describes construction process and explains the control strategy. The theoretical...
-
Compensation of Dead Time Effects for Shunt Active Power Filters
PublicationThe paper presents a comprehensive approach to the compensation of the grid current distortion for shunt active power filter systems. Four different sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the estimation of compensating currents and grid voltages, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Design and evaluation of a base module of active power electronic transformer
Publication -
A Special Multi-Pulse Converter with Small Active Power Filter
Publication -
High power, medium voltage, modular active power filtering system
Publication -
Comprehensive compensation of grid current distortion by shunt active power filters
PublicationThe paper presents a comprehensive approach to the compensation of grid current distortion in shunt active power filter systems. Four sources of current distortion are addressed: imperfect grid synchronization caused by the distortion in the grid voltages, time delays in the evaluation of grid voltages and computation of compensating currents, fluctuations of the dc bus voltage, and the distortion of inverter output voltages due...
-
Experimental tests results of the diode rectifier with series active power filter
Publication -
A novel approach to energy safety improvement in the marine power plants with active power surge compensator
PublicationPaper raises a point of power surges and theirs adverse effects in the marine power plants. The article explains a source of surges appearance, and presents measurements carried out on a modern ship. It discusses effects of dynamic power transients on the ship’s energy safety. Finally it proposes, a novel approach for power surge elimination, based on medium voltage active conditioner. As well as it propose the topology and control...
-
A new method of wind farm active power curve estimation based on statistical approach
PublicationThe purpose of this paper is to solve the wind farm active power estimation problem, introducing the method which is based on a statistical approach and robust fitting. The proposed algorithm uses a statistical approach and compared to existing ones- includes a wind direction as well as the influence of turbine start-up procedure on the estimation. The results show that additional estimation inputs i.e. the wind direction and the...
-
A hybrid, coupled reactors based 18-pulse diode rectifier with active power filter
Publication -
The use of a static electrical energy meter as a transducer of active power to a pulse frequency signal
Publication -
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
The impact of the distribution network reconfiguration on active power losses: Selected issues of UPGRID project realization
PublicationThe dynamic development of smart grids allows the use of remote controllable switches to change the configuration of the distribution network. The paper discusses the impact of the distribution system reconfiguration on active power losses, taking into account the typical daily load profiles. Based on modified IEEE 33-bus test distribution system the article presents the method of selection the appropriate sensitivity factor and...
-
Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current
PublicationThis paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed‐loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model‐based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved...
-
A diode rectifier with a Special Coupled Reactor and additional Active Power Filter in the Marine Local Power Network Supply Conditions
Publication -
A multi-pulse diode rectifier with a coupled three-phase reactor and additional small shunt active power filter
Publication -
Supply system based on the 18-pulse diode rectifier with coupled reactors and integrated with the series active power filter
Publication -
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublicationThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Compensation of supply current harmonics, reactive power, and unbalanced load current balance in the closed-loop control of a shunt active power filter
PublicationThis paper presents the compensation tasks performed by a shunt active power filter, including compensation of harmonic currents, reactive power, and an unbalanced load current. The paper demonstrates novel control of the shunt active power filter in a closed-loop system. The control algorithm was verified by performing simulations and compared the simulated results with those obtained in an open-loop control system. All simulations...
-
Measurements of active power distribution in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data expressing an active...
-
Measurements of active power coefficients in a ship power station with two generators working in parallel
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing active...
-
Measurements of the coefficients of active power distribution between two generators operating in parallel in a ship power station
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing coefficients...
-
High power, zero ripples active filtering system with power modules operating in parallel
Publication -
Single-phase power electronics transformer with active functions for smart grid
PublicationThis paper presents the control of one cell of a modular single-phase power electronics transformer with active functions for meeting the smart grid concept. In this way, the converter could be used not only as a conventional transformer but also for grid such as reactive power, harmonic elimination and energy storage. The topology of the cell is composed by a bidirectional converter with three stages: a half bridge in the input...
-
Single-phase power electronics transformer with active functions for smart grid
Publication -
Balancing energy consumption in limited power grid with active front-end and three phase dual active bridge system
PublicationPaper deals with simulation analysis of bidirectional power converters system for charging station of electric vehicle in condition of limited power source in city infrastructure. In case of incapability to provide additional power supply through the grid by virtue of historical, architectural and economic reasons it is possible to solve this issue by implementation of mobile battery-powered supply source. The proposed bidirectional...
-
Analytical Estimation of Power Losses in a Dual Active Bridge Converter Controlled with a Single-Phase Shift Switching Scheme
PublicationMicro-grid solutions around the world rely on the operation of DC/DC power conver- sion systems. The most commonly used solution for these topologies is the use of a dual active bridge (DAB) converter. Increasing the efficiency and reliability of this system contributes to the improvement in the stability of the entire microgrid. This paper discussed an analytical method of energy efficiency and power loss estimation in a single...
-
СИЛОВОЙ ПРЕОБРАЗОВАТЕЛЬ С АКТИВНЫМ ПОДАВЛЕНИЕМ ВЫСШИХ ГАРМОНИК ДЛЯ СИСТЕМ ЭЛЕКТРОСНАБЖЕНИЯ ЛЕТАТЕЛЬНЫХ АППАРАТОВ (Power converter with active suppression of higher harmonics for aircraft power supply systems)
PublicationПредставлены два алгоритма активной фильтрации для силового преобразователя с активным подавлением высших гармоник. Первый алгоритм основан на дискретном преобразовании Фурье: посредством синтезированной системы управления инвертированные измеренные высшие гармоники напряжения поступают на вход инвертора. Второй метод управления основан на алгоритме с использованием принципов самообучения, что значительно снижает потребность в...
-
Semi complex navigation with an active optical gesture sensor
PublicationThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
Analysis of Properties of an Active Linear Gesture Sensor
PublicationBasic gesture sensors can play a significant role as input units in mobile smart devices. However, they have to handle a wide variety of gestures while preserving the advantages of basic sensors. In this paper a user-determined approach to the design of a sparse optical gesture sensor is proposed. The statistical research on a study group of individuals includes the measurement of user-related parameters like the speed of a performed...
-
Sensorless predictive control of three-phase parallel active filter
PublicationThe paper presents the control system of parallel active power filter (APF) with predictive reference current calculation and model based predictive current control. The novel estimator and predictor of grid emf is proposed for AC voltage sensorless operation of APF, regardless of distortion of this voltage. Proposed control system provides control of APF current with high precision and dynamics limited only by filter circuit parameters....
-
Conjugated control of triple active bridge converter with common HFT
PublicationPaper presents synthetic analyses of single input, dual output DC/AC/DC converter with common high frequency transformer. Rise the problem of cross-coupling power flows between secondary terminals, under asymmetrical control operating condition. It also proposes a new approach to converter control, based on conjugated phase shift modulation and defines its limitations. Finally, the developed control technique was verified by simulation...
-
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublicationThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Selected anionic and cationic surface active agents: case study on the Kłodnica sediments
PublicationSurface active agents (surfactants) are a group of chemical compounds, which are used as ingredients of detergents, cleaning products, cosmetics and functional products. After use, wastes containing surfactants or their degradation products are discharged to wastewater treatment plants or directly into surface waters. Due to their specific properties of SAAs, compounds are able to migrate between different environmental compartments...
-
Unsupervised machine-learning classification of electrophysiologically active electrodes during human cognitive task performance
PublicationIdentification of active electrodes that record task-relevant neurophysiological activity is needed for clinical and industrial applications as well as for investigating brain functions. We developed an unsupervised, fully automated approach to classify active electrodes showing event-related intracranial EEG (iEEG) responses from 115 patients performing a free recall verbal memory task. Our approach employed new interpretable...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublicationThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles
PublicationAn optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency...
-
Iterative learning approach to active noise control of highly autocorrelated signals with applications to machinery noise
PublicationThis paper discusses the design and application of iterative learning control (ILC) and repetitive control (RC) for high modal density systems. Typical examples of these systems are structural and acoustical systems considered in active structural acoustic control (ASAC) and active noise control (ANC) applications. The application of traditional ILC and RC design techniques, which are based on a parametric system model, on systems...
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublicationPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
Dual Active Bridge (DAB) DC-DC converter for multilevel propulsion converters for electrical multiple units (EMU)
PublicationSemiconductor power devices made from silicon carbide (SiC) reached a level of technology enabling their widespread use in power converters. Two different approaches to implementation of modern traction converters in electric multiple units (EMU) have been presented in recent years: (i) 3.3-kV SiC MOSFET-based three-level PWM inverter with regenerative braking and (ii) 6.5-kV IGBT-based four-quadrant power electronic traction transformer...
-
Multiple output differential OTA with linearizing bulk-driven active-error feedback loop for continuous-time filter applications
PublicationA CMOS circuit realization of a highly linear multiple-output differential operational transconductance amplifier (OTA) has been proposed. The presented approach exploits a differential pair as an input stage with both the gate and the bulk terminals as signal ports. For the proposed OTA, improved linearity is obtained by means of the active-error feedback loop operating at the bulk terminals of the input stage. SPICE simulations...
-
Power electronic transformer based on cascaded H-bridge converter
PublicationIn this paper the control strategy of power electronic transformer (PET) is proposed. The analyzed structure of PET uses two seven-level cascaded H-bridge (CHB) rectifiers. The electrical power of PET is transferred between DC-links of CHB converters using dual-active-bridges (DABs) and low voltage high frequency transformers. The roposed solution allows for controlling the active and reactive power with a low level of harmonic...
-
Improvement of Oxygen Electrode Performance of Intermediate Temperature Solid Oxide Cells by Spray Pyrolysis Deposited Active Layers
PublicationIntermediate temperature solid oxide fuel cells oxygen electrodes are modified by active interfacial layers. Spray pyrolysis is used to produce thin (≈500 nm) layers of mixed ionic and electronic conductors: Sm0.5Sr0.5CoO3−δ (SSC), La0.6Sr0.4CoO3−δ (LSC), La0.6Sr0.4Co0.2Fe0.8O3−δ (LSCF), and Pr6O11 (PrOx) on the electrode–electrolyte interface. The influence of the annealing temperature on the electrode polarization (area specific...
-
Problems of Connecting Wind Farms to the Power System with HV Cables
PublicationThis paper presents problems caused by connecting wind farms to a power system with high voltage cables. The author highlights possible problems with reactive power compensation, depending on the arrangement of the shunt reactor connection and settings of control systems for reactive power and voltage of the wind farm. The paper also discusses issues of increasing active power losses caused by a shunt reactor installation.
-
Code development of a DSP-FPGA based control platform for power electronics applications
PublicationThis paper focuses on the implementation of power electronics algorithms in control platforms based on DSP-FPGA. Today’s power electronics technology demands high power computation with high speed interfacing at the same time. The most popular configuration is a DSP for the former and a FPGA for the latter. The main goal of this work was to develop a generic control system for power electronics application, but it is explained...
-
Comparative analysis of three‐phase dual active bridge converter with different transformer topology and modern universal control for DC microgrids
PublicationThe presented work discusses issues related to the use of modern multiphase topologies of Dual Active Bridge (DAB)-type converters. Converters of this type are widely used in most DC microgrid applications. The introduction emphasizes a comparative analysis between single-phase and multi-phase DAB topologies within high-power DC microgrids, delving into their respective advantages, drawbacks, design procedures, and considerations...
-
THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS
PublicationThe paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.
-
Evaluation of VSC Impact on Power System Using Adequate P-Q Capability Curve
PublicationRenewable energy sources, which are becoming increasingly popular, often use a voltage source converter (VSC) for connection to the power system. Assessing the effects of connecting such a source to the power system is essential to ensure the proper operation of the power system and the connected source. For this purpose, it is necessary to know the range of active and reactive power generation by the converter. The authors indicate...
-
Measurements of no-load and short-circuit parameters of power transformers with taps
Open Research Data1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E).
-
VSC converters control for offshore wind farms HVDC grid connection
PublicationThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Cross-border transmission line configuration influence on the electrical power and energy billing process
PublicationIn 2015 a connection between the Polish and Lithuanian power systems become fully operational. The connection consists of a 400 kV double circuit transmission line and a back-to-back HVDC substation located on the Lithuanian side. A magnetic couplings between the circuits of the transmission line cause that during power transmission a different values of active power losses are observed in both circuits. This situation may cause...
-
New Performance Indices for Power System Stabilizers
PublicationThe subject of the article is issues related to innovative indices for power system stabilizers (PSSs). These new indices will be able to quickly show which PSS (among many other PSSs) is not working properly and that advanced optimization and simulation methods should be used to improve the PSS settings. The authors note the fact that the acceptance requirements for PSSs are different in various power systems. Moreover, the authors...
-
THE PHASE SHIFTERS INFLUENCE ON THE POWER SYSTEM STABILITY
PublicationThe paper presents the effect of phase shifters as FACTS devices on the possibility of improving the angle stability. Presented results obtained by the dynamic simulation performed on the mathematical model of the three machine system cooperating with the 400 kV network. The generative blocks models include turbine models with their controllers and models of synchronous generators with their excitation systems and voltage regulation....
-
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, mplementation, Experiments
PublicationFirst section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer,...
-
Power Electronic Transformer For Smart Grid Application
PublicationIn this paper the control system of Power Electronic Transformer (PET) for the Smart Grid application is proposed. The structure of PET is based on two Cascaded H-bridge (CHB) converters. The electrical energy is transferred between converters using Dual-Active-Bridges (DAB) and high-frequency transformers. This type of coupling has been used to connect the DC-links of all H-bridges. The proposed control system for PET makes it...
-
Active dynamic thermography in cardiosurgery
Publication.
-
Active dynamic thermography in mammography.
PublicationW artykule przedstawiono zaproponowany numeryczny model termiczny piersi z nowotworem umiejscowionym na różnych głębokościach. Przedstawione są wyniki symulacji modelu dla różnych warunków zewnętrznego pobudzenia termicznego powierzchni piersi. Pokazano również wyniki przykładowego badania termograficznego piersi z nowotworem.
-
Active shape models in practice
PublicationAutorzy wykonali uniwersalny system lokalizacji obiektów zawierający implementację aktywnych modeli kształtu, a przeprowadzone z użyciem tego systemu eksperymenty wykazały powżne wady badanej metody. W pracy przedstawiono zaobserwowane w praktyce problemy związane ze stosowaniem metody aktywnych modeli kształtu (ASM).
-
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
PublicationIn the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including...
-
Advanced Control Structures of Turbo Generator System of Nuclear Power Plant
PublicationIn the paper a synthesis of advanced control structures of turbine and synchronous generator for nuclear power plant working under changing operating conditions (supplied power level) is presented. It is based on the nonlinear models of the steam turbine and synchronous generator cooperating with the power system. Considered control structure consists of multi-regional fuzzy control systems with local linear controllers, including...
-
Simulation Studies of Control Systems for Doubly Fed Induction Generator Supplied by the Current Source Converter
PublicationThe control system for a Doubly Fed Induction Generator (DFIG) supplied by a grid-connected Current Source Converter (CSC) is presented in this paper. Nonlinear transformation of DFIG model to the multi-scalar form is proposed. The nonlinear control strategy of active and reactive power of DFIG is realized by feedback linearization. In the proposed control scheme, the DFIG model and CSI parameters are included. Two Proportional-Integral...
-
Occurrence of Surface Active Agents in the Environment
PublicationDue to the specific structure of surfactants molecules they are applied in different areas of human activity (industry, household). After using and discharging from wastewater treatment plants as effluent stream, surface active agents (SAAs) are emitted to various elements of the environment (atmosphere, waters, and solid phases), where they can undergo numerous physic-chemical processes (e.g., sorption, degradation) and freely...
-
Active IR-Thermal Imaging in Medicine
PublicationIn this paper we summarize results of several research projects devoted to development of new diagnostic methods and procedures based on quantitative infrared thermography in medical applications. First, basics of active dynamic thermography are presented. Described are both, instrumentation and software comprising measurement procedures including collection of series of IR-images after external excitation, data treatment with...
-
Chapter 8 – Active Sampling of Air
PublicationThis chapter reviews the literature information on analytical techniques and laboratory equipment used for active sampling of air (atmospheric and indoor) in regular monitoring research. It describes popular analytical devices applied for sample collection using various types of polymeric bags, e.g. Tedlar bags, Teflon or Nafion bags, and/or stainless steel vacuum containers. It reviews literature data about the application of...
-
Active carbons from waste biochars
Publication -
Active Dynamic Thermography in Medical Diagnostics
PublicationThis is an overview of active thermal imaging methods in medical diagnostics using external thermal stimulation. In this chapter, several clinical cases diagnosed using the active dynamic thermography method, ADT, are presented. Features of this technology are discussed and main advantages underlined. Applications in skin burn diagnostics and quantitative evaluation leading to modern classification of burned patients for further...
-
Active Learning Based on Crowdsourced Data
PublicationThe paper proposes a crowdsourcing-based approach for annotated data acquisition and means to support Active Learning training approach. In the proposed solution, aimed at data engineers, the knowledge of the crowd serves as an oracle that is able to judge whether the given sample is informative or not. The proposed solution reduces the amount of work needed to annotate large sets of data. Furthermore, it allows a perpetual increase...
-
Conducting polymers electrodeposited on active metals
PublicationPraca poświęcona studiom literaturowym doniesień dotyczących polimerów przewodzących, osadzanych na metalach aktywnych. Zastosowanie polimerów przewodzących jako warstw antykorozyjnych oraz elektrokrystalizacja metali na polimerach przewodzących zostały zebrane i przedstawione w tej pracy.
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Power Electronics Building Blocks for implementing Smart MV/LV Distribution Transformers for Smart Grid
PublicationWith an observed increase in the involvement of active consumers in activities aimed at improving energy efficiency and increasing interest in producing energy from renewable sources, there is a need for the development of new technologies enabling the distribution network operators to offer new services and functionalities. Smart MV/LV distribution transformers are characterized by a compact three-stage design, including an...
-
Voltage and frequency regulation of a standalone induction generator by reduced-rating power electronic compensators - comparative evaluation
PublicationIn this paper are considered two fundamental topologies of power electronic compensators for voltage and frequency control of a standalone self-excited induction generator (IG) system. These are voltage and current source inverter based shunt compensators with energy storage. The aim of this study is to assess main features of both topologies in dynamic and steady-state IG operation. The whole system is modelled with the aid of...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublicationThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
Innovative Bidirectional Isolated High-Power Density On-Board Charge for Vehicle-to-Grid
PublicationThis paper deals with developing and implementing a bidirectional galvanically isolated on-board charger of a high-power density. The power density of the new charger was 4 kW/kg and 2.46 kW/dm3, and the maximum efficiency was 96.4% at 3.4 kW. Due to the requirement to achieve a high-power density, a single-stage inverter topology was used. Regarding switching losses, due to the topology of the circuit with so-called hard switching,...
-
Measurements of power supply system properties of "Magnetic SpeedLine" ultra-fast robot prototype for IML labeling
Open Research DataTests of the power supply system of "SpeedLine magnetic" ultra-fast industrial robot for IML labeling were carried out to analyze the effect of the active power filter (APF) parameters on the power quality. at the target duty cycle. Tests were performed with the target duty cycle. Linear synchronous motors with permanent magnets were used to drive...
-
Interconnection of the Customer-Side Resources Using Single Phase VAPF
PublicationThe paper introduces method for utilization of the customer-side generated energy using single phase voltage active power filter. Structure and control method of the power electronics converter has been described and some simulation results are shown to prove usefulness of this arrangements. Proposed application realizes the following functions: power quality improvement, uninterruptible supplying and energy costs reduction.
-
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
PublicationPoniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
-
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Ancillary services to grids provided with distributed generation
PublicationThe paper introduces system for utilization of the customer-side generated energy. Additionally system can secure some ancillary services to grids. Those services include: current active filtering, load voltage stabilization and in case of grid voltage faults - uninterruptible load supplying (possible with energy storage device). Presented experimental results confirm flexibility of this arrangement in processes of power delivery...
-
Implementation of Active Dynamic Thermography in medical diagnostics
PublicationW pracy przedstawiono wyniki badań wdrożeniowych Aktywnej Termografii Dynamicznej w diagnostyce wybranych chorób.
-
Baltic cyanobacteria – a source of biologically active compounds
Publication -
Optimization of active circuits for substrate noise suppression
PublicationZakłócenia generowane przez szybkie podukłady cyfrowe w mieszanych systemach analogowo-cyfrowych realizowanych na wspólnym podłożu stają się dużym problemem. W pracy zaproponowano metodę optymalizacji aktywnych układów tłumienia zakłóceń. Zilustrowano skuteczność działania metody na wybranym układzie i uzyskano ponad 9 dB poprawę tłumienia zakłóceń na częstotliwości 1GHz w porównaniu do znanych rozwiązań.
-
Comparison of active proximity radars for the wearable devices
PublicationTwo methods of object position and movement estimation in relation to the user of smart glasses were investigated. An active infrared and ultrasonic methods of the obstacle detection were presented and compared. Application of these methods depend on active transducers type (physical medium used), geometry and surface properties of detected objects and their movement direction and speed. In the article properties of both detectors...
-
Comparative molecular modelling of biologically active sterols
PublicationMembrane sterols are targets for a clinically important antifungal agent – amphotericin B. The relatively specific antifungal action of the drug is based on a stronger interaction of amphotericin B with fungal ergosterol than with mammalian cholesterol. Conformational space occupied by six sterols has been defined using the molecular dynamics method to establish if the conformational features correspond to the preferential interaction...
-
Photo-acoustic response of active biological systems
PublicationZbadano dwie próbki organiczne gatunku Trunculariopsis trunculus,jedną wilgotną, drugą - suchą. W obu przypadkach zaobserwowanointensywne szerokie pasma absorpcyjne w zakresie widzialnym (żółtymi poniżej 330 nm). Widma foto-akustyczne zawierają wszystkie pasma uznane za związane z aktywnością biologiczną.
-
COMPARATIVE ANALYSIS OF ACTIVE GEODETIC NETWORKS IN POLAND
Publication -
Research on Linear Actuators for Active Foil Bearings
PublicationActive foil bearings are a kind of gas foil bearing. They contain actuators which allow for modification of the bearing sleeve size and the shape of the lubrication gap. Rotor vibrations can be actively controlled by these changes. It is possible, among other things, to reduce the starting torque, control the vibration amplitude at different speeds and improve operational safety. Prototypes of active foil bearings are being developed...
-
Active Suppression of Nonstationary Narrowband Acoustic Disturbances
PublicationIn this chapter, a new approach to active narrowband noise control is presented. Narrowband acoustic noise may be generated, among others, by rotating parts of electro-mechanical devices, such as motors, turbines, compressors, or fans. Active noise control involves the generation of “antinoise”, i.e., the generation of a sound that has the same amplitude, but the opposite phase, as the unwanted noise, which causes them to interfere...
-
Synthesis of parametric images in the medical active thermography
PublicationArtykuł przedstawia zastosowanie nowej metody syntezy obrazów w termografii dla potrzeb opisu ilościowego właściwości termicznych tkanek. opis taki umożliwia różnicowanie przypadków medycznych. Metodę zastosowania dla licznych pomiarów fantomowych oraz in vitro. Przedstawiono i omówiono rezultaty prac.
-
Modeling of active fiber Bragg grating sensors
PublicationW artykule omówiono działanie przetwornika hydrofonu wykorzystującego profilowaną membranę sprzężoną z aktywną światłowodową siatką Bragga. W wyniku modelowania, wykonanego Metodą Elementów Skończonych, stwierdzono występowanie gradientów naprężeń wzdłuż siatki. Opracowano program do modelowania pasywnych i aktywnych światłowodowych siatek Bragga wykorzystujący metodę modów sprzężonych. Przedstawiono charakterystyki widmowe pasywnych...