Search results for: calibration
-
Assessment of the Accuracy of a Virtual Multi-Channel Temperature Measuring Instrument
PublicationThe multi-channel temperature measurement system developed works with NTC thermistors. The article presents the results of theoretical and empirical evaluation of accuracy obtained in measurement channels. The basis for the theoretical assessment is the mathematical model for each of the measurement channels and the characteristics of the system elements included in the circuits of the measurement channel. Two different methods were...
-
Images of the Seabed of the Gulf of Gdansk Obtained by Means of the Parametric Sonar
PublicationThe main goal of this paper is to present results of the experimental investigation of the seabed by means of parametric echosounder in the form of chosen images. The phenomena of nonlinear interaction between two parallel beams of high intensity gives as a results very narrow beam of low frequency wave, that enables to penetrate the sea bottom. The first step of our investigations was calibration of all the elements of the measuring...
-
Gdansk Bay sea bed sounding and classification of its results
PublicationThe main goal of this paper is to describe the results of sounding the Gdansk Bay sea bed by using a SES-2000 Standard parametric sub-bottom profiler. Quality of data obtained during trials depends inter alia on a proper location of transducer array to reduce influence of pitch, roll and heave motions as well as ship self noise (resulting from bubbles due to propeller and flow around hull, vibration generated by main engine and...
-
Model based evaluation of plant improvement at a large wastewater treatment plant (WWTP)
PublicationIn this work, the effect of the improvement carried out at a large-scale wastewater treatment plant (WWTP) was evaluated, by means of modelling works, with the aim to determine the influence of the modernization over the process performance. After modernization, the energy consumption due to the aeration decreased about a 20% maintaining the effluent quality. In order to double-check the good effluent quality, modelling works were...
-
Electron interactions with Bis(pentamethylcyclopentadienyl) titanium(IV) dichloride and difluoride
PublicationWe present a combined experimental and theoretical study of the interaction of electrons with Bis(pentamethylcyclopentadienyl)titanium(IV) dichloride (Cp∗2TiCl2) and difluoride (Cp∗2TiF2). We report the experimental measurements of partial cross sections for the dissociative electron attachment (DEA) and the electron ionization (EI) mass spectra of isolated molecules. Estimates of the absolute cross sections are done on the basis...
-
Loudness Scaling Test Based on Categorical Perception
PublicationThe main goal of this research study is focused on creating a method for loudness scaling based on categorical perception. Its main features, such as: way of testing, calibration procedure for securing reliable results, employing natural test stimuli, etc., are described in the paper and assessed against a procedure that uses 1/2-octave bands of noise (LGOB) for the loudness growth estimation. The Mann-Whitney U-test is employed...
-
Application and evaluation of M-EPDG for performance analysis of Polish typical flexible and rigid pavements
PublicationThe main goal of the paper is to implement and evaluate the M-EPDG and the software AASHTOware to analyse the performance of new flexible and rigid pavements designed according to the Polish catalogues, which are comparable with analogous catalogues used in other European countries. For this purpose the site-specific inputs for Poland were determined and described in the paper as well as compared to the default input data used...
-
Determination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose
PublicationThe paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures—toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene — characterized by different odour intensity and hedonic tone. A principal component regression (PCR) calibration...
-
Selectivity of amperometric gas sensors in multicomponent gas mixtures
PublicationIn recent years smog and poor air quality became a growing environmental problem. There is a need to continuously monitor the quality of air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, a selectivity of the six amperometric gas sensors is being investigated. Calibration of sensors has been performed in order to find a correlation between concentration...
-
A New Approach to Capacitive Sensor Measurements Based on a Microcontroller and a Three-Gate Stable RC Oscillator
PublicationA complete smart capacitive sensor solution basedA complete smart capacitive sensor solution based on a microcontroller was developed. This approach includes the development of both the hardware and software. The hardware part comprises an 8-bit microcontroller equipped with two timers/counters and a three-gate stable RC relaxation oscillator. The software part handles system configuration, measurement control, communication control,...
-
Hydrauliczna wiarygodność wyników pomiarów terenowych stosowanych do identyfikacji oporności hydraulicznej przewymiarowanych sieci wodociągowych
PublicationPublikacja zawiera zalecenia metodyczne dotyczące identyfikacji oporności hydraulicznej w przewymiarowanych sieciach wodociągowych na tle spotykanych nieprawidłowości. Krytycznie oceniono wyniki pomiarów terenowych, które zastosowano do tarowania komputerowych modeli przepływów (KMP) pomimo, że nie spełniały kryterium hydraulicznej wiarygodności. Ponadto zaproponowano spadek hydrauliczny jako obiektywny wskaźnik wiarygodności pomiarów,...
-
Towards hand grip force assessment by using EMG estimators
PublicationThe purpose of this study was to propose a method to assess individual regression (calibration) curves to establish a relationship between an isometric grip force and surface electromyography (EMG) estimator. In this study 18 healthy volunteers (12 male (23.0 ± 2.0 years) and 6 female (23.2 ± 0.7 years)) had been examined. Ten EMG estimators (mean absolute value, root mean square, entropy, energy, turns per second, mean of zero...
-
Development of Local IDF-formula Using Controlled Random Search Method for Global Optimization
PublicationThe aim of the study is to present the effective and relatively simple empirical approach to rainfall Intensity-Duration-Frequency-formulas development, based on Controlled Random Search (CRS) for global optimization. The approach is mainly dedicated to the cases in which the commonly used IDF-relationships do not provide satisfactory fit between simulations and observations, and more complex formulas with higher number of parameters...
-
Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels
PublicationAttention is focused on the issues of flow resistance and pressure drop of perspective refrigeration fluids during condensation in the two-phase flow in minichannels. The case of the flow through a cylindrical single channel of 2.3 mm inner diameter was carefully analyzed. Pressure drop tests have been performed in diabatic flow conditions. The effect of heat flux, mass flux, vapour quality and saturation temperature on the two-phase...
-
Acoustic imaging of selected areas of Gdansk Bay with the aid of parametric echosounder and side-scan sonar
PublicationThe article presents and analyses the data recorded during sounding of the Gdansk Bay seabed with the aid of a parametric echosounder and a side-scan sonar. The accuracy of seabed structure examination, as a condition for obtaining valuable results, requires correct configuration of echolocation devices and proper calibration of peripheral devices, such as the survey unit geographical position sensor – GPS, the navigation unit,...
-
A Theoretical and Experimental Study of Moderate Temperature Alfa Type Stirling Engines
PublicationThe Stirling engine is a device that allows conversion of thermal energy into mechanical energy with relatively high efficiency. Existing commercial designs are mainly based on the usage of high temperature heat sources, whose availability from renewable or waste heat sources is significantly lower than that of moderate temperature sources. The paper presents the results of experimental research on a prototype alpha type Stirling...
-
Testing of the longest span soil-steel bridge in Europe – new quality in measurements
PublicationThe article describes interdisciplinary and comprehensive diagnostic tests of final bridge inspection and acceptance proposed for a soil – steel bridge made of corrugated sheets, being the European span length record holder (25.74 m). As an effect of an original concept a detailed and precise information about the structure response was collected. The load test design was based on the nonlinear numerical simulations performed by...
-
Pure cross-anisotropy for geotechnical elastic potentials
PublicationThe pure cross-anisotropy is understood as a special scaling of strain (or stress). The scaled tensor is used as an argument in the elastic stiffness (or compliance). Such anisotropy can be overlaid on the top of any elastic stiffness, in particular on one obtained from an elastic potential with its own stress-induced anisotropy. This superposition does not violate the Second Law. The method can be also applied to other functions...
-
DLC coating in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
Four Degree-of-Freedom Hydrodynamic Maneuvering Model of a Small Azipod-Actuated Ship With Application to Onboard Decision Support Systems
PublicationThe main contribution of this paper is a numerical ship motion model of NTNU’s research vessel Gunnerus, capturing the surge, sway, roll, and yaw dynamics when sailing in uniform and steady currents. The model utilizes a crossflow drag formulation for the transverse viscous loads, and it includes a nonlinear formulation for the propulsion and steering loads provided by two azipod thrusters. A wide range of experimental data obtained...
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublicationIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis
PublicationLiquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI–MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace® Ultracore™ SuperC18™ (100 × 2.1 mm, 2.5 μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple “dilute & shoot” approach...
-
Model-Based Evaluation of N2O Production Pathways in the Anammox-Enriched Granular Sludge Cultivated in a Sequencing Batch Reactor
PublicationA mechanistic model was developed as an extension of the Activated Sludge Model No. 1 to describe three nitrous oxide (N2O) production pathways in a laboratory-scale anammox-enriched granular sequencing batch reactor. Heterotrophic denitrification and two processes mediated by ammonia oxidizing bacteria (AOB), that is, ammonia (NH4+) oxidation via hydroxylamine (NH2OH) and autotrophic denitrification, were considered. A systematic...
-
An new method of audio-visual correlation analysis
PublicationThis paper presents a new methodology of conducting the audio-visual correlation analysis employing the gaze tracking system. Interaction between two perceptual modalities, seeing and hearing, their interaction and mutual reinforcement in a complex relationship was a subject of many research studies. Earlier stage of the carried out experiments at the Multimedia Systems Department (MSD) showed that there exists a relationship between...
-
Simultaneous determination of individual isothiocyanates in plant samples by HPLC-DAD-MS following SPE and derivatization with N-acetyl-l-cysteine
PublicationThe procedure for the isothiocyanates (ITCs) determination that involves derivatization with N-acetyl-l-cysteine (NAC) and separation by HPLC was developed. Prior to derivatization, plant ITCs were isolated and purified using solid-phase extraction (SPE). The optimum conditions of derivatization are: 500 μL of isopropanolic eluate obtained by SPE combined with 500 μL of derivatizing reagent (0.2 M NAC and 0.2 M NaHCO3 in water)...
-
Modeling sequencing batch reactor operational conditions depending on oxygen concentration
PublicationSequencing batch reactors (SBR) can be used as a fill-and draw activated sludge system for wastewater treatment with considerable operating flexibility and the possibility to conduct experiments under standard conditions and extreme case scenarios. Mathematical modeling and computer simulations provide an opportunity to implement existing wastewater processes in modeling software and evaluate different modifications at low costs...
-
Toward Robust Pedestrian Detection With Data Augmentation
PublicationIn this article, the problem of creating a safe pedestrian detection model that can operate in the real world is tackled. While recent advances have led to significantly improved detection accuracy on various benchmarks, existing deep learning models are vulnerable to invisible to the human eye changes in the input image which raises concerns about its safety. A popular and simple technique for improving robustness is using data...
-
Extraction and Analysis of Bisphenols and Their Derivatives in Infant and Toddler Ready-to-feed Meals by Ultrasound-assisted Membrane Extraction Followed by LC MS/MS
PublicationThis research developed an ultrasound-assisted membrane extraction coupled with liquid chromatography-tandem mass spectrometry method for the determination of nineteen bisphenols and their derivatives in infant and toddler ready-to-feed meals. The calibration curves for all analytes were linear in the tested range, and the limit of detection and limit of quantitation were in the range 0.27 to 0.79 ng/g and 0.80 to 2.4 ng/g, respectively....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
Force-deformation spectroscopy in contact mode
Open Research DataThe deformation-distance spectroscopic curve is obtained by registering the value of the probe cantilever deflection as a function of the elongation of the piezoelectric scanner. It assumes a simple relationship in the form of Hooke’s law, linking the deformation of the lever with the amount of its deflection caused by the proximity of the probe and...
-
Integrated model for the fast assessment of flood volume: Modelling – management, uncertainty and sensitivity analysis
PublicationThe specific flood volume is an important criterion for assessing the performance of sewage networks. It has been shown that its value is greatly influenced by the layout of the sewers in the catchment area, which is usually expressed by a fractal dimension. Currently, only mechanistic models (such as SWMM) enable the determination of the impact of the layout of the sewers on flooding volume, but they require additional and robust...
-
Progress in the post weld residual stress evaluation using Barkhausen effect meter with a novel rotating magnetic field probe
PublicationWe report the progress in post weld residual stress evaluation using Barkhausen effect (BE) meter with rotating magnetic field probe. The novel probe of the BE meter contains two C-core electromagnets and searching coil with ferrite antenna. This meter allows automatic measurements of BE intensity envelopes at different angles of magnetizing field. The full process of measurement at given position of the probe takes about only...
-
MICROCOMPASS FOR SAFE SEA NAVIGATION
PublicationThis paper presents the results of design microcompass for safe sea navigation where navigation, electronic, programming knowledge was joined to make more safe sea navigation. In first part of article presents navigation tools which using in practise. Article underlines that mostly satellite system is used to make navigation, but recommends traditional navigation method like alternative to determinate position in case of breakdown...
-
Levels of 13 multi-class pesticide residues in Polish honeys determined by LC-ESI-MS/MS
PublicationLevels of 13 pesticides in 40 honey samples form Poland are reported. A rapid and sensitive method was developed for the LC-ESI-MS/MS determination of multi-class pesticide residues in honey samples. Liquid-liquid extraction (LLE) on a diatomaceous earth support (requiring the use of small amounts of organic solvent), followed by chromatographic separation on a C18 column and gradient elution were employed. The method quantifies...
-
Application of probabilistic tools to extend load test design of bridges prior to opening
PublicationLoad tests of bridges are widely performed in a large number of countries. Deterministic comparison of measurement results to the theoretical, FEM (finite element method)-based outcomes with possible further calibration is mostly applied. Sometimes, the data collected in the tests are also used to calibrate the reliability factors of bridge structures or their components. This work proposes to complement the stage of the load test...
-
NUMERICAL ANALYSIS OF SPECIES DIFFUSION AND METHANOL DECOMPOSITION IN THERMOCATALYTIC REACTOR BASED ON THE INTERMETALLIC PHASE OF Ni3Al FOR LOW REYNOLDS NUMBERS
PublicationNumerical modelling of hydrogen production by means of methanol decomposition in a thermocatalytic reactor using corrugated foil made of the Ni3Al intermetallic phase is shown in the paper. Experimental results of the flow analysis of mixtures containing helium and methanol in a thermocatalytic reactor with microchannels were used for the initial calibration of the CFD calculations (calculations based on the Computational Fluid...
-
Evaluating the influence of radiative heat flux on convective heat transfer from a vertical plate in air using an improved heating plate
PublicationThis article examines the influence of radiative heat flux on the accuracy of the results of free convective heat transfer in air. In order to carry out these tests, based on the experience gained during the operation of a plate heated on one side, compensated by a reverse heat loss flux counter-heater, a unique double-sided heating sandwich plate was designed and built, consisting of three thin epoxy resin plates reinforced with...
-
The effect of external load on ultrasonic wave attenuation in steel bars under bending stresses
PublicationThe stress state in deformed solids has a significant impact on the attenuation of an ultrasonic wave propagating through the medium. Measuring a signal with certain attenuation characteristics can therefore provide useful diagnostic information about the stress state in the structure. In this work, basic principles behind a novel attenuation-based diagnostic framework are introduced. An experimental study on steel bars under three-point...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublicationThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Novel Complementary Resonator for Dielectric Characterization of Substrates Based on Permittivity and Thickness
PublicationThis paper presents a novel complementary resonator featuring high sensitivity, low fabrication cost, and improved performance. The proposed structure consists of a complementary concentric square and circular ring resonator (CCSCRR) with multiple splits to enhance the inductance of the resonator. The proposed CCSCRR is coupled to a microstrip transmission line with an impedance of fifty ohms to create a high-sensitivity sensor....
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublicationThe aim of the paper is to analyze data obtained during sounding the Gdansk Bay sea bed by means of the parametric echo-sounder. The accuracy of the sea bottom structure investigation needs correct configuration of research equipment and proper calibration of peripheral devices (GPS, heading sensor, MRU-Z motion sensor and navigation instruments which provide necessary data to bathymetrical measurement system, enabling its work...
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublicationThe aim of the paper is to analyze data obtain during sounding of the Gdansk Bay by means of the parametric sonar. The accuracy of the sea bottom structure investigation needs the correct configuration of research equipment and the proper calibration of peripheral devices (GPS, heading sensor, motion sensor MRU-Z and navigation units) which provide necessary data to bathymetrical measurement system enabling its work with whole...
-
Robust Object Detection with Multi-input Multi-output Faster R-CNN
PublicationRecent years have seen impressive progress in visual recognition on many benchmarks, however, generalization to the out-of-distribution setting remains a significant challenge. A state-of-the-art method for robust visual recognition is model ensembling. However, recently it was shown that similarly competitive results could be achieved with a much smaller cost, by using multi-input multi-output architecture (MIMO). In this work,...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublicationNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...