Search results for: INSTRUMENTATION AMPLIFIER
-
Multiple output second-generation current conveyor utilizing high frequency output stage
PublicationIn this paper a multiple output second-generation current conveyor (MOCCII) is presented. The main advantage of the proposed general circuit architecture over a typical structure, well known in the literature, is the use of a high passband multiple output current mplifier block instead of cascaded current mirrors. It gives similar frequency responses for all the outputs of the current conveyor and also maintains simplicity of the...
-
A 1-nS 1-V Sub-1-µW Linear CMOS OTA with Rail-to-Rail Input for Hz-Band Sensory Interfaces
PublicationThe paper presents an operational transconductance amplifier (OTA) with low transconductance (0.62–6.28 nS) and low power consumption (28–270 nW) for the low-frequency analog front-ends in biomedical sensor interfaces. The proposed OTA implements an innovative, highly linear voltage-to-current converter based on the channel-length-modulation effect, which can be rail-to-rail driven. At 1-V supply and 1-Vpp asymmetrical input driving,...
-
DDLMS PCR double digestion Ligation Mediated Suppression PCR - a new technique for bacterial specific differentiation
PublicationA new diagnostic kit for K. oxytoca specific differentiation based on ddLMS PCR (ang. double digest ligation Mediated PCR) technique is shown. As a species-specific DNA fragment pehX gene, encoding the enzyme polygalactouronase, was chosen. The genome sequence of K. oxytoca is digested with two endonucleases: AclI and BclI which cut DNA before and after pehX gene. The polymorphic DNA fragments are ligated with AclI-end-specific...
-
Acoustic emission studies of the 7075 aluminium alloy pitting corrosion process
Open Research DataThe dataset contains the cyclic polarization studies and corresponding acoustic emission measurements, revealing the pitting corrosion process of the passive layer at the surface of the 7075 aluminum alloy in the borate buffer with different chloride ions concentrations, in the range between 0.05 and 25 mM.
-
Loop-mediated isothermal amplification (LAMP) as a diagnostic tool in detection of infectious diseases
PublicationLoop-mediated isothermal amplification (LAMP) is a gene amplification method which amplifies DNA with high specificity and efficiency under isothermal conditions. Because of its rapidity and simplicity, it is a valuable diagnostic tool in the early detection and identification of infectious diseases. LAMP method is based on the use of a set of four to six specially designed primers spanning six to eight distinct sequences on the...
-
Ionosphere variability I: Advances in observational, monitoring and detection capabilities
PublicationThe paper aims to review recent advances regarding the observational and monitoring capabilities of the ionization conditions in the Earth's upper atmosphere. The analysis spans both ground and space-based experiments, seeking for new installations and/or missions, new or upgraded instrumentation and/or observational network establishments as means for advancing current understanding and prediction ability of the ionosphere variability....
-
Fiber optic low-coherence Fabry-Pérot interferometer with ZnO layers in transmission and reflective mode: comparative study
PublicationA construction of a low-coherence fiber-optic Fabry-Pérot interferometer using a thin ZnO layer as a reflective surfaces was proposed and examined. In the investigated setup, the ZnO layer of thickness 200 nm were deposited on the face of the standard telecommunication single-mode optical fiber (SMF-28). Measurements of interference signal were performed for the interferometer working in the transmission and reflective mode, as...
-
Excitation-independent constant conductance isfet driver
PublicationA new constant conductance driver for ISFETs sensors has been developed. The proposed circuit maintains the sensor operating point at constant drain-source conductance. The combination of a simple, self-balancing resistance bridge and the subtraction half (or similar fraction) of source-drain voltage from the gate-source voltage provides the independence of output signal from current and voltage drivers instability. The use of...
-
Continuous‐Frequency Method of Measurement of Electrode Impedance
Publication -
Two-phase flow structure assessment based on dynamic image analysis
Publication -
Continuous frequency method of measurement of electrode impedance.
PublicationPrzedstawione zostały matematyczne podstawy nowej metody pomiaru impedancji elektrodowej. Metoda wykorzystuje sygnał pobudzenia którego częstotliwość zmienia się liniowo w czasie. Amplituda sinusoidalnego niestacjonarnego pobudzenia jest stała. Zapis i analiza sygnału pobudzenia i odpowiedzi pozwalana wyznaczenie ciągłego widma impedancyjnego. Jednoczesna analiza czasowo częstotliwościowa wykonano została przy użyciu transformacji...
-
Harmonic analysis of the current of an electric system simulating the electrode process in conditions of linearly changing potential
PublicationAnalizowany był prąd elektrycznego modelu symulującego pierwszorzędową reakcję elektrodową zachodzącą w warunkach liniowo zmieniającego się potencjału z nałożonym sygnałem sinusoidalnym. Pokazano, że transformacja Fouriera nie odzwierciedla zmian amplitudy składowych komponentów w funkcji potencjału. Także matematycznie wykazano, że zastosowanie transformacji Gabora do analizy spektralnej pozwala uzyskać poprawną dekompozycję częstotliwościową....
-
Description of the silo flow and bulk solid pulsations detection using ECT
PublicationW artykule przedstawiono wyniki zastosowania tomografii pojemnościowej do analizy pulsacji występujących w bezkohezyjnym materiale sypkim podczas opróżniania silosu cylindrycznego. Przeanalizowano wpływ parametrów zmiennych (zagęszczenia początkowego, szorstkości ściany, prędkości opróżniania) na wielkość dynamicznych pulsacji)
-
Uncertainty of the liquid mass flow measurement using the orifice plate
PublicationThe article presents an estimation of measurement uncertainty of a liquid mass flow using the orifice plate. This subject is essential because of the widespread use of this type of flow meters. Not only the quantitative estimation but also the qualitative results of those measurements are important. To achieve these results the authors of the paper propose to use the theory of uncertainty. The article shows the analysis of the...
-
Estimating the uncertainty of discharge coefficient predicted for oblique side weir using Monte Carlo method
PublicationSide weir is a hydraulic structure, which is used in irrigation systems to divert some water from main to side channel. It is installed at the entrance of the side channel to control and measure passing water into the side channel. Many studies provided side weir water surface profile and coefficient of discharge to measure water discharge diverted into the side channel. These studies dealt with different side weir shapes (rectangular,...
-
Determination of phenylbutazone, sulfamethazine, carbendazim and linuron using a novel pine bark biosorbent for solid-phase extraction (SPE) with high-performance liquid chromatography (HPLC)
PublicationThe paper presents a novel pine bark based biosorbent for solid-phase extraction (SPE). The morphology and composition of the pine bark were characterized using Fourier transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM). The biosorbent was used for the preparation of wastewater for the determination of phenylbutazone, sulfamethazine, carbendazim, and linuron by high performance liquid chromatography with...
-
PCR-RFLP assays for species-specific identification of fungi belonging to Scopulariopsis and related genera
PublicationFungi of the Scopulariopsis genus, commonly found in the environment, are opportunistic pathogens that can cause various types of human infections. So far, no efficient molecular method has been developed for species differentiation among Scopulariopsis and related genera. In order to advance this field, we have evaluated performance of polymerase chain reaction restriction fragment length polymorphism (PCR-RFLP) assays, based...
-
Multiple output differential OTA with linearizing bulk-driven active-error feedback loop for continuous-time filter applications
PublicationA CMOS circuit realization of a highly linear multiple-output differential operational transconductance amplifier (OTA) has been proposed. The presented approach exploits a differential pair as an input stage with both the gate and the bulk terminals as signal ports. For the proposed OTA, improved linearity is obtained by means of the active-error feedback loop operating at the bulk terminals of the input stage. SPICE simulations...
-
Digital microcontroller for sonar waveform generator
PublicationGenerating sounding signals is essential for the operation of active sonar. The system should be highly reliable. This can be achieved through architecture, communication between the devices, and a well-designed and self–testing software. The system presented in the article is responsible for the generation of hydroacoustic sounding signals, and ensures proper interaction between power amplifiers and power supplies. Thanks to its...
-
Genotyping of clinical isolates of fluconazole-resistant Candida albicans
PublicationThe aim of the study was to compare the discriminatory power of RAPD-PCR method with using RSD10 primer and microsatellite analysis with using (GACA)4 primer for genotyping clinical isolates of fluconazole-resistant C. albicans. Isolates were received from patients of Children's Memorial Health Institute in Warsaw. However in the case of both tested methods low number of amplified fragments was generated, nine and six different...
-
Technique to improve CMRR at high frequencies in CMOS OTA-C filters
PublicationIn this paper a technique to improve the common-mode rejection ratio (CMRR) at high frequencies in the OTA-C filters is proposed. The technique is applicable to most OTA-C filters using CMOS operational transconductance amplifiers (OTA) based on differential pairs. The presented analysis shows that a significant broadening of CMRR bandwidth can be achieved by using a differential pair with the bodies of transistors connected to...
-
A novel microstrip dual-layer rat-race coupler with compact size and enhanced bandwidth
PublicationMicrowave hybrid couplers are crucial components of mixers, phase shifters, amplifiers and other high-frequency systems. Conventional couplers are characterized by large size which limits their usefulness in modern applications. In this work, a novel compact rat-race coupler with enhanced bandwidth has been proposed. The structure consists of six compact microstrip resonant cells. It is implemented on two separate layers which permits...
-
Nanoparticles displacement analysis using optical coherence tomography
PublicationOptical coherence tomography (OCT) is a versatile optical method for cross-sectional and 3D imaging of biological and non-biological objects. Here we are going to present the application of polarization sensitive spectroscopic OCT system (PS-SOCT) for quantitative measurements of materials containing nanoparticles. The PS-SOCT combines the polarization sensitive analysis with time-frequency analysis. In this contribution the benefits...
-
Proton Transfer Reaction Mass Spectrometry for Plant Metabolomics
PublicationVolatile organic compounds (VOCs) emitted by plants are a valuable source of information on their growth, theirresponse to stress, and the condition of their habitat. The recent trend in the analysis of low-mass molecules ofplant origin is metabolomics, which in the context of volatiles is often referred to as volatolomics. It requires theuse of modern analytical instrumentation...
-
Liquid–phase microextraction: A review of reviews
PublicationSample preparation is an important step in chemical analysis. It is generally done to deal with problems associated with the nature of the matrix, low analyte concentrations in real samples or analyte features incompatible with the instrumentation. Classical methods of extraction consume large volumes of hazardous solvents and other reagents and are not in line with the recent emergence of green analytical chemistry. Liquid-phase...
-
Realistic noise-tolerant randomness amplification using finite number of devices
PublicationRandomness is a fundamental concept, with implications from security of modern data systems, to fundamental laws of nature and even the philosophy of science. Randomness is called certified if it describes events that cannot be pre-determined by an external adversary. It is known that weak certified randomness can be amplified to nearly ideal randomness using quantum-mechanical systems. However, so far, it was unclear whether randomness amplification...
-
Properties of recombinant trehalose synthase from Deinococcus radiodurans expressed in Escherichia coli
PublicationA trehalose synthase gene from Deinococcus radiodurans(DSMZ 20539)containing 1659 bp reading frame encoding 552 amino acids was amplified using PCR. The gene was finally ligated into pET30Ek/LIC vector and expressed after isopropyl β-d-thiogalactopyranoside induction in Escherichia coli (DE3) Rosetta pLysS. The recombinanttrehalose synthase (DraTreS) containing a His6-tag at the C-terminus was purified by metal affinity chromatography...
-
Fusion of DNA-binding domain of Pyrococcus furiosus ligase with TaqStoffel DNA polymerase as a useful tool in PCR with difficult targets
PublicationThe DNA coding sequence of TaqStoffel polymer- ase was fused with the DNA-binding domain of Pyrococcus furiosus ligase. The resulting novel recombinant gene was cloned and expressed in E. coli. The recombinant enzyme was purified and its enzymatic features were studied. The fusion protein (PfuDBDlig-TaqS) was found to have enhanced processivity as a result of the conversion of the Taq DNA polymerase from a relatively low processive...
-
The electromagnetic field intensity in industrial buildings
Open Research DataThe dataset contains the results of measurements of electromagnetic fields, separately electric and magnetic, carried out at selected places in the building of an operating industrial enterprise.
-
Mucinous carcinoma - Female, 69 - Tissue image [5040730020274161]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous carcinoma - Female, 69 - Tissue image [5040730020275231]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous carcinoma - Female, 69 - Tissue image [5040730020274231]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Mucinous carcinoma - Female, 69 - Tissue image [5040730020277561]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Novel sorptive extraction techniques in bioanalysis evaluated by Blue Applicability Grade Index: The paradigm of fabric phase sorptive extraction and capsule phase microextraction
PublicationFabric phase sorptive extraction (FPSE) and capsule phase microextraction (CPME) are two sol-gel derived microextraction techniques that emerged in the last decade towards the minimization of the environmental impact of conventional sample preparation approaches. Complementary to the well-established green metric tools, Blue Applicability Grade Index (BAGI) was recently proposed for the evaluation of method’s practicability. In...
-
Absorption spectroscopy setup for determination of whole human blood and blood–derived materials spectral characteristics
PublicationA dedicated absorption spectroscopy system was set up using tungsten-halogen broadband source, optical fibers, sample holder, and a commercial spectrometer with CCD array. Analysis of noise present in the setup was carried out. Data processing was applied to the absorption spectra to reduce spectral noise, and improve the quality of the spectra and to remove the baseline level. The absorption spectra were measured for whole blood...
-
Optoelectronic device for hematocrit measurements
PublicationAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Green Analytical Chemistry: Summary of Existing Knowledge and Future Trends
PublicationAnalysis of recent publications in green analytical chemistry shows the current trends and future needs in this area. The main issues are related with search for cheaper, more efficient, more accurate, greener and miniaturized alternatives. Miniaturization is perhaps, the most notable current trend in analytical chemistry. Rapid developments and improvements in instrumentation have led to impressive range of benchtop technology...
-
Low cost set-up for supercapacitors parameters evaluation
PublicationSupercapacitors are capable to store relatively high amount of energy comparing to its mass. Growing number of these devices applications requires development of new testing methods. Standard methods of evaluation of supercapacitor parameters, as cycling voltammetry, CV, galvanostatic cycling with potential limitation, GCPL, impedance measurements, require equipment of high cost...
-
Progress in development of molecularly imprinted polymers as sorbents for sample preparation
PublicationSample preparation has been one of the most often investigated steps in analytical procedures.These investigations are focused on problems such as isolation of analytes from the sample matrix, matrix implification, analyte enrichment to the level above the detection limit of the instrumentation used, and the removal of interfering species to improve the final determination. Techniques based on solid (adsorption) and pseudo liquid...
-
A family of new generation miniaturized impedance analyzers for technical object diagnostics
PublicationThe paper presents the family of three analyzers allowing to measure impedance in range of 10 ohm<|Zx|<10 Gohm in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzers family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of impedance measurement method based on digital signal processing DSP. The miniaturization and other above mentioned...
-
SUBJECTIVE PERCEPTION OF MUSIC GENRES IN THE FIELD OF MUSIC INFORMATION RETRIEVAL SYSTEMS
PublicationThe aim of this paper is to evaluate the relationship between perception of music genres and subjective features of music that can be assigned to them. For this purpose a group of subjective features such as loudness, melody, rhythm, volume, instrumentation was chosen to describe music genres. A group of 30 listeners with normal hearing, ranging from 20 to 40, was created. Each sub-ject participating in listening tests was asked...
-
SUBJECTIVE PERCEPTION OF MUSIC GENRES IN THE FIELD OF MUSIC INFORMATION RETRIEVAL SYSTEMS
PublicationThe aim of this paper is to evaluate the relationship between perception of music genres and subjective features of music that can be assigned to them. For this purpose a group of subjective features such as loudness, melody, rhythm, volume, instrumentation was chosen to describe music genres. A group of 30 listeners with normal hearing, ranging from 20 to 40, was created. Each sub-ject participating in listening tests was asked...
-
Soxhlet Extraction and New Developments Such as Soxtec in: Comprehansive Sampling and Sample Preparation
PublicationSoxhlet extraction is one of the most popular techniques for extraction of analytes from solid materials. Since its discovery in 1879, the standard Soxhlet technique has been routinely applied in almost every analytical laboratory. Up to this day, Soxhlet extraction technique remains a standard technique to which the performance of modern extraction techniques is compared.Over the years, an intensive research on different modifications...
-
Database of speech and facial expressions recorded with optimized face motion capture settings
PublicationThe broad objective of the present research is the analysis of spoken English employing a multiplicity of modalities. An important stage of this process, discussed in the paper, is creating a database of speech accompanied with facial expressions. Recordings of speakers were made using an advanced system for capturing facial muscle motion. A brief historical outline, current applications, limitations and the ways of capturing face...
-
The shallow sea experiment with usage of linear hydrophone array
PublicationPurpose of this article is to present designed and made linear hydrophone array and the results obtained during in situ trails on Gulf of Gdańsk. The measuring system allowed to localize hydrophones in the selected points and perform measurements in both the horizontal antenna positioning and vertical. Made in this way recordings allow creating accurate 3D imaging of sound intensity/propagation. During research three floating objects...
-
A new nethod for RTS noise of semiconductor devices identification
PublicationIn the paper, a new method, called the noise scatterin pattern method (NSP method), for random telegraph signal noise identyfication in the inherent noise of semiconductor devices is described. A block diagram of a noise measurement system based on the NSP method is presented. Examples of patterns of the NSP method are presented.
-
Using a square-wave signal for fault diagnosis of analog parts of mixed-signal electronic embedded systems
PublicationArtykuł przedstawia nowe podejście do detekcji i lokalizacji pojedynczych katastroficznych i parametrycznych uszkodzeń części analogowych w mieszanych sygnałowo elektronicznych systemach wbudowanych. Podejście składa się z trzech etapów: tworzenia słownika uszkodzeń na podstawie krzywych identyfikacyjnych, etapu pomiarowego w którym układ badany pobudzany jest falą prostokątną generowaną przez mikrokontroler a odpowiedź jest próbkowana...
-
Method using bilinear transformation for measurement of impedance parameters of a multielement two-terminal network
PublicationArtykuł przedstawia metodę identyfikacji parametrów impedancyjnych obiektów modelowanych dwójnikami. Metoda wykorzystuje właściwości przekształcenia biliniowego pozwalającego na przedstawienie impedancji obiektu jako funkcji każdego z parametrów obwodu zastępczego z osobna. Odwrotne przekształcenie biliniowe pozwala na wyznaczenie wartości każdego parametru na podstawie pomiaru impedancji na jednej częstotliwości dobranej dla...
-
On electrochemical noise analysis for monitoring of uniform corrosion rate
PublicationSzybkość korozji jest określona przez rezystancję polaryzacyjną warstwy metal-elektrolit. Jej wartość może być wyznaczona za pomocą pomiarów szumów elektrochemicznych. Przedstawiono szczegółowo algorytm wyznaczania wartości rezystancji polaryzacyjnej na podstawie rejestrowanych sygnałów losowych dla przykładowych wyników badań eksperymentalnych. Oszacowano dokładność wyznaczanej wartości.
-
Fault diagnosis of analog piecewise linear circuits based on homotopy
PublicationArtykuł opisuje weryfikację metodą diagnostyki analogowych układów odcinkowo-liniowych opartą na podejściu homotopijnym. Homotopia przekształca jedną funkcję f(x) w inną funkcję g(x) poprzez zmianę parametru homotopii tî[0,1]. Ścieżka homotopijna pokazuje drogę od punktu x0 z dziedziny funkcji f(x) do odpowiadającego mu punktu x* funkcji g(x). Idea metody zakłada wykorzystanie funkcji f(x) do opisu diagnozowanego układu w stanie...