Wyniki wyszukiwania dla: CURRENT MEASUREMENT
-
Remote current measurement with FPGA digital processing
PublikacjaThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Current measurement and analysis for induction motor diagnostics
PublikacjaPrzedstawiono sposób diagnozowania łożysk tocznych w silnikach indukcyjnych z wykorzystaniem pomiarów i analizy prądu zasilającego silnik. Zaprezentowano metodę pomiarową i opracowania danych diagnostycznych. Uzyskano zgodność częstotliwości składowych widma prądu otrzymanych z badań teoretycznych i eksperymentalnych.Podano wyniki badań łożysk o róznych uszkodzeniach i prawdopodobieństwa poprawnych diagnoz.
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublikacjaThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
Leakage Current Measurements of Surge Arresters
PublikacjaThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Measurement cell - current density analysis.
PublikacjaW pracy przedstawiono model celki do pomiarów elektrycznych parametrów szkliwa i innych tkanek zęba. Wyniki otrzymano za pomocą metody elementu skończonego. Wykazano, że możliwa do osiągnięcia dokładność pomiaru jest zdeterminowana przez prąd upływu celki.
-
Visual measurement system for chosen parameters of current collectors
PublikacjaA current collector is an element in a traction vehicle, used for movable, contact con-nection between the main circuit of this vehicle and the contact line. Bad technical condi-tion of these important elements in the main circuit of the vehicle result in its incorrect cooperation with contact line. Periodic control of technical condition of current collectors ensures infallible current collection. The pantograph diagnostics consists...
-
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublikacjaW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublikacjaMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Dead-Time Effect Compensation Based on Additional Phase Current Measurements
PublikacjaThis paper proposes a new method of dead-time effect compensation. The proposed solution is based on additional phase current measurements realized by analog-to-digital converters. These measurements are carried out at the time instants specified by a pulsewidth-modulation (PWM) strategy. This makes it possible to estimate inverter currents at the commutation instants and, finally, to estimate the voltage error caused by dead time. This...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublikacjaW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublikacjaMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublikacjaThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Optoelectronic properties of the metal-tetracene interface investigated by current noise measurement under monochromatic irradiation.
PublikacjaZaprezentowano badania prądów ograniczonych elektrodowo w warstwach tetracenu. Szczególną uwagę zwrócono na zależność szumów elektrycznych od przyłożonego napięcia i padającego światła.
-
O zastosowaniu metody prądów wirowych do technicznego pomiaru własności elektrycznych i magnetycznych metali = About application of eddy current method for technical measurement of electric and magnetic properties of metals
PublikacjaOpisano wyniki badań nad wykorzystaniem efektu prądów wirowych do badania własności elektrycznych i magnetycznych metali. Badania wykonano za pomocą sondy różnicowej. Wyniki pomiarów zależności częstotliwościowej wykonane dla modelowych materiałów porównano z wynikami modelowania metodą elementów skończonych.
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Dane BadawczeThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Current divider-based nanosecond high current pulse measuring systems
PublikacjaThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Influence of vision measurement system spatial configuration on measurement uncertainty, based on the example of electric traction application
PublikacjaTechnical diagnostics plays a significant role in ensuring operational reliability of electrified rail transport. The most critical point in the transmission of electric energy to vehicles is the sliding contact of the current collector with the traction network. For this reason, work is currently being carried on new measuring methods, whose appliance allows for more complete diagnostics of the contact line and current collectors,...
-
Measurement methods for assessing insulation condition of underground pipelines
PublikacjaThe paper discusses the most frequently applied measurement methods for assessing the quality of external insulation along pipelines and detecting defect locations in the protective coating. The quality of coating along a given pipeline section under investigation is assessed by determining unitary resistance of the coating, which is calculated on the basis of measurement results obtained along a pipeline subjected to cathodic...
-
Determining the leakage current resistive component by the orthogonal vector method
PublikacjaThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublikacjaIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublikacjaA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Measurements of the coefficients of current distribution between two generators operating in parallel in a ship power station
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/Analyzer (E/A v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering of Gdynia Maritime University. The attached dataset contains processed data, expressing the coefficients...
-
Technical diagnostics and monitoring of traction current collectors
PublikacjaNew evaluation methods of the technical condition of rolling stock current collectors are proposed in this paper. The method of automatic measurement of the pantograph static force characteristic, realized when the vehicle runs through the test section of the track with especially prepared overhead line height distribution, has been practically implemented by the Polish Railways. The method of testing the slipper spring suspension...
-
The issue of uncertainty of visual measurement techniques for long distance measurements based on the example of applying electric traction elements in diagnostics and monitoring
PublikacjaRail transport is the most economical and energy-effective in the field of land transport, in particular electrified. In order to ensure efficient and reliable operation of electrified rail transport, the issues of monitoring and diagnostics of the traction infrastructure and vehicles are extremely important. The most critical point in the transmission of electric energy to the vehicle is the sliding contact of the current collector...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Using A Particular Sampling Method for Impedance Measurement
PublikacjaThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublikacjaThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublikacjaThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Low-power device simulator for micro-energy measurement methods testing
PublikacjaThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor
PublikacjaDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides...
-
Current-based higher-order spectral covariance as a bearing diagnostic feature for induction motors
PublikacjaConducting the diagnosis of induction motors remotely by analyzing the supply current is an attractive prospect with the lack of access to the engine. Currently, there is no solution, based on analysis of the current, the credibility of which would allow its use in industry. The statistics of bearing failures in induction motors indicate that they constitute more than 40% of induction motor damage, therefore, bearing diagnosis...
-
Sensorless IPMSM drive with rotor position estimator based on analysis of phase current derivatives
PublikacjaThis paper describes a sensorless Interior Permanent Magnet Synchronous Motor (IPMSM) drive designed for traction applications. Wide-speed sensorless operation is provided with the use of three methods of rotor position estimation designed for: a standstill, low- and high-speed range. The paper focuses on the high-speed estimation algorithm. The estimator uses the derivatives of motor phase currentsresulting from PWM modulation...
-
Selected results of signal measurements in a ship power station with two generators working in parallel with the use of the Estimator/Analyzer instrument
Dane BadawczeThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/ Analyser (A/E v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering, of Gdynia Maritime University. The instrument performs a set of measurement functions that...
-
Experimental verification of visual method for measuring displacements of contact line elements
PublikacjaThe increase of rail vehicles speed, as well as the increase of their power, puts high demands on the power delivery system for traction vehicles The most critical point in the vehicle's power supply circuit is the contact between the current collector and contact wires. Ensuring a reliable co-operation of the current collector and contact line, requires technical development...
-
STUDY OF ARRAY OF MEMS INERTIAL MEASUREMENT UNITS UNDER QUASI-STATIONARY AND DYNAMIC CONDITIONS
PublikacjaA measurement system includes all components in a chain of hardware and software that leads from a measured variable to processed data. In that context, the type and quality of the sensors or measuring devices are critical to any measurement system. MEMS/IMU sensors lag behind leading technologies in this respect, but the MEMS/IMU performance rapidly changes while is relatively inexpensive. For this reason, the paper proposes...
-
Influence of span length and impulse front time on earthing measurement accuracy of power line towers
PublikacjaThe article discusses the issue of measuring and assessing the features of power line tower earthings using fast-changing waveform. The study analyses the effect of impulse front time and the line span length on errors made during these measurements using impulse meters. It has been found that the assessment conditions similar to the static measurement results occur for the use of 4 μs current impulses and such procedure is useful...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublikacjaThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
The concept of estimation of elevator shaft control measurement results in the local 3D coordinate system.
PublikacjaGeodetic control measurements play an important part because they provide information about the current state of repair of the construction, which has a direct impact on the safety assessment of its exploitation. Authors in this paper have focused on control measurements of the elevator shaft. The article discusses the problem of determining the deviation of elevator shaft walls from the vertical plane in the local 3D coordinate...
-
Statistics of AFM current-voltage curves
Dane BadawczeMapping surface electrical conductivity offers enormous cognitive possibilities regarding the structure and properties of modern materials. The technique invented for this purpose (Conductive AFM) by Murrel's team and colleagues allows independent monitoring of the local conductivity of materials in correlation with the topographic profile. The mentioned...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Dane BadawczeThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Atomic force microscopy images of copper electrical contacts wear under the influence of friction
Dane BadawczeMeasurement of wear of copper electrical contacts under the influence of friction. Imaging in contact mode in the variant of scanning spreading resistance microscopy. Additionally, there are spectroscopic current-voltage curves showing local changes in electrical conductivity. NTEGRA Prima (NT-MDT) device. Probe NSG 01Pt.
-
The method of location and identification of weak electric field source in seawater
PublikacjaThe paper presents the method and measurement system that allows to lacate the detected object and to identify parameters of its simplified model in form of a current dipole.
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Instantaneous power signal measurements for bearing diagnostics
Dane BadawczeBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
Analysis of thoracic regional impedance changes using PCA approach
PublikacjaA multichannel impedance and one lead electrocardiographic recording system has been developed. The impedance measurement unit is built using a four-electrode technique. It consists of a sinusoidal, 40 kHz, current source and five measurement channels. Circumferential current electrodes have been located at a neck and an abdomen. Voltagemeasurement disk electrodes formed five two-electrode measurement ports. The impedance change...
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublikacjaThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
Metrological analysis of an computerized system of protection against electric shock in circuits with variable speed drives
PublikacjaDrive systems, that can be operated at variable speed, are equipped with power electronics converters. This causes distortion of the earth current, and consequently the need to take into account the use of proper protective devices in relation to earth current harmonics. This paper presents a system for protection against electric shock in circuits with power electronics converters and metrological analysis indicating the requirements...
-
3D Machine Vision System for Inspection of Contact Strips in Railway Vehicle Current Collectors
PublikacjaConstruction and technical condition of current collectors is crucial to reliability and safety of railway transportation. According to the Technical Specifications for Interoperability railway vehicles in the European Union should be equipped with carbon contact strips. Excessive wear or defects of contact strips degrade the capability of undisturbed power transmission, cause faster wear of contact wire, and can even result in...
-
Old-timer Vehicle - Braking Efficiency Measurement at Vehicle Inspection Stations and Roadworthiness Validity Certificate.
PublikacjaObtaining the Roadworthiness Validity Certificate for an old-timer vehicle involves an appropriate test performance, namely, "Old-timer Vehicle Technical Specification Compliance Test". It seems obvious that this kind of test should include a considerable checklist, however, the current legal regulations connected with this test are not specific enough. One of the certificates issued on this test results is "Old-timer Vehicle Technical...
-
Hydrogen sulphide electrocatalytic gas sensor
PublikacjaIn this article measurement results of the electrocatalytic gas sensor in different concentrations of hydrogen sulphide are presented. Working principle of such sensor is based on electric current acquisition, while voltage ramp is applied to the sensor. During voltage sweep oxidation and reduction reactions occurs on the sensor electrodes. Obtained current-voltage plot has unique shape connected...
-
Tax system in Poland - current situation and direction of changes
Dane BadawczeThe study conducted on a group of 259 entrepreneurs from various regions of Poland concerns the opinions of business owners on the current tax situation, as well as potential changes in the tax system.
-
Tax system in Poland - current situation and direction of changes
Dane BadawczeThe study conducted on a group of 259 entrepreneurs from various regions of Poland concerns the opinions of business owners on the current tax situation, as well as potential changes in the tax system.
-
Testing of Software for the Planning of a Linear Object GNSS Measurement Campaign under Simulated Conditions
PublikacjaThe precision of a linear object measurement using satellite techniques is determined by the number and the relative position of the visible satellites by the receiver. The status of the visible constellation is described by DOP. The obtained geometric coefficient values are dependent on many variables. When determining these values, field obstacles at the receiver location and satellite positions changing with time must be taken...
-
Analysis of measurement uncertainty for contact-less method used to measure the position of catenary contact wire, performed with the use of Monte Carlo method
PublikacjaCurrently the majority of main railway lines in Europe are electrified, and electric trains have the biggest share in the entire amount of rail transport. Reliability of electrified railways is closely related to the issue of supplying traction vehicles with energy. The problems connected with diagnostics of energy consumption node, namely the contact line and the current collector, are therefore of fundamental importance for maintaining...
-
Diagnostics of induction motor bearings - possibility of measurements
PublikacjaIn induction motors damage in the elements of electromagnetic system, for example in the wiring of stator, rotor or in the magnetic circuit can appear as well as damage of mechanical parts (bearings, rotor, shaft). Bearing diagnostics is so important in supervision of motor condition, because extensive research shows that the bearings arethe elements most susceptible to damage. This paper presents the research which the author...
-
Induction Motor Bearings Diagnostic Using MCSA and Normalized Tripple Covariance
PublikacjaDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides...
-
Electrical conductivity relaxation measurements - oxidation and reduction of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Dane BadawczeThe dataset consists of 2 main catalogs: measurements performed for oxidation/reduction in dry conditions and in humid conditions. For Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the sample was measured in the ProboStat™ measurement system. The ECR measurements were...
-
A predictive estimation based control strategy for a quasi-resonant dc-link inverter
PublikacjaIn this paper the predictive estimation based control strategy for a quasi-resonant dc link inverter (PQRDCLI) is developed. Instead of direct measurement of dc link input inverter current – its estimation with one step prediction is applied. The PQRDCLI fed induction motor, controlled with a predictive current estimation stabilized inverter output voltage slopes independently of load. Moreover, reduction of overvoltage spikes...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublikacjaThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Supply current signal and artificial neural networks in the induction motor bearings diagnostics
PublikacjaThis paper contains research results of the diagnostics of induction motor bearings based on measurement of the supply current with usage of artificial neural networks. Bearing failure amount is greater than 40% of all engine failures, which makes their damage-free operation crucial. Tests were performed on motors with intentionally made bearings defects. Chapter 2 introduces the concept of artificial neural networks. It presents...
-
Use of Neural Networks in Diagnostics of Rolling-Element Bearing of the Induction Motor
PublikacjaBearing defect is statistically the most frequent cause of an induction motor fault. The research described in the paper utilized the phenomenon of the current change in the induction motor with bearing defect. Methods based on the analysis of the supplying current are particularly useful when it is impossible to install diagnostic devices directly on the motor. The presented method of rolling-element bearing diagnostics used indirect...
-
MCSA with Normalized Triple Covariance as a bearings diagnostic indicator in an induction motor
PublikacjaStatistics of bearing failures in induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is very important. Vibration methods for bearing diagnostics have one major disadvantage - they require the availability of the machine for sensors installation. This is the reason for seeking new methods based on motor supply current analysis. Diagnosis of induction motors, conducted remotely...
-
How to define and measure informal employment in CEE countries - the case of Poland
PublikacjaThe study of informal employment is still associated with several obstacles, from the scope of definition, through measurement methods, to policy recommendations. This article aims to revise the existing methodological frames in order to point out how to improve the study of informal employment in CEE countries. The case of Poland serves to examine whether the common definitions and measurement methods are suitable for an inclusive...
-
Electrical conductivity relaxation measurements - water uptake of BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Dane BadawczeFor Electrical Conductivity Relaxation (ECR) measurements, platinum reversible electrodes were applied in a four-probe arrangement and the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ sample was measured in the ProboStat™ measurement system. The ECR measurements were performed in air in the temperature range of 450-800 ℃ after switching water partial pressure between...
-
Using On-line Measurement by Electronic Nose and Computer Simulations for Real-time Control at WWTP
PublikacjaContinuous investigation of wastewater quality can be carried out by a device called an e-nose. One important feature of the proposed real-time control system for WWTP is that using on-line measurements by e-nose together (Figure 1) with technological sets picked on this basis by means of computer models, it is possible to change treatment process parameters, depending on the current quality of wastewater. It can be used for the...
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublikacjaW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Towards Designing an Innovative Industrial Fan: Developing Regression and Neural Models Based on Remote Mass Measurements
PublikacjaThis article presents the process of the construction and testing a remote, fully autonomous system for measuring the operational parameters of fans. The measurement results obtained made it possible to create and verify mathematical models using linear regression and neural networks. The process was implemented as part of the first stage of an innovative project. The article presents detailed steps of constructing a system to...
-
Benchmarking the Digital Government Value Chain
PublikacjaDigital Government (DG) benchmarking is an academically vivid topic and, equally important, a tool with the potential to provide valuable insights to policymakers and public managers responsible for digital policies at the level of countries and international bodies. Alas, this potential remains largely untapped in the current DG benchmarking practice. In our study, we identify the reasons and propose a way of mitigating them....
-
EMI mitigation of GaN power inverter leg by local shielding techniques
PublikacjaThis paper presents local shielding techniques applied to a half-bridge inverter leg with the aim to reduce the common mode (CM) current noise at converter’s DC input. The research study is conducted for 650V Enhancement mode Gallium Nitride (GaN) power transistor switches. Main contributors of parasitic capacitances referred to the inverter-leg middle point node are identified. Then, shielding solutions are proposed to reduce...
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode.
PublikacjaThis study presents a novel approach to impedance measurements. The methodology discussed is limited to contact in the sample-probe system under ambient conditions without the presence of electrolyte. Comparison with results of direct and alternating current measurements for well-defined metallic surfaces are made. In spite of idealization related to the type of contact examined, the proposed technique provides an improvement of...
-
Analysis of the Accuracy of Pulse Estimation Using Smart Watches
PublikacjaThe purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...
-
Fuel cell noise data
Dane BadawczeMeasurement data of Hydrogen PEM fuel cels. The voltage fluctuations were measured over single cels of stack of 10 cels.
-
Rate performance of the V2O5 nanocrystals as cathode material in Li-ion batteries
Dane BadawczeThe DataSet contains the galvanostatic charge/discharge curves of the V2O5 nanocrystals obtained by the sol-gel method. The battery tests of the samples were performed using the Atlas-Sollich 0961 (Atlas-Sollich, Poland) with different current densities in the voltage range between 2.0 V and 4.0 V vs. Li/Li+. Here 1C is 294 mAh g-1.
-
Rate performance of the V2O5 nanorods as cathode material in Li-ion batteries
Dane BadawczeThe DataSet contains the galvanostatic charge/discharge curves of the V2O5 nanorods obtained by the sol-gel method. The battery tests of the samples were performed using the Atlas-Sollich 0961 (Atlas-Sollich, Poland) with different current densities in the voltage range between 2.0 V and 4.0 V vs. Li/Li+. Here 1C is 294 mAh g-1.
-
Hydrographic Multisensory Unmanned Watercraft
PublikacjaThis article describes the design of the unmanned surface vessel (USV) and the algorithms for planning the trajectories to be followed on measurement missions. The algorithms take account of the dynamically varying impacts of external forces (wind and surface current) on the vessel's motion. Feedback loops enable the counteraction of external factors that cause disturbance to the desired trajectory. The sensors installed on the...
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Dane BadawczeThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Dane BadawczeThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublikacjaIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
Szacowanie niepewności pomiarowej układu do diagnostyki łożysk opartej na analizie mocy chwilowej.
PublikacjaW artykule przedstawiono metodologię szacowania niepewności pomiarowej wykorzystanego do badań diagnostycznych łożysk silników indukcyjnych układu pomiarowego, składającego się z dzielnika napięcia oraz bocznika. Wyniki tych analiz pozwalają spre-cyzować, jakiej niepewności pomiarowej można się spodziewać, dokonując badań diagnostycznych łożysk silników indukcyjnych w określonych warunkach, na stanowisku badawczym metodą pomiaru...
-
Szacowanie niepewności pomiarowej układu do diagnostyki łożysk opartej na analizie mocy chwilowej
PublikacjaW artykule przedstawiono sposób szacowania niepewności układu pomiarowego, składającego się z dzielnika napięcia oraz bocznika, który wykorzystano do badań diagnostycznych łożysk silników indukcyjnych. Wyniki analizy metrologicznej pozwalają sprecyzować, jakiej niepewności pomiarowej można się spodziewać, dokonując badań diagnostycznych łożysk silników indukcyjnych w określonych warunkach, na stanowisku badawczym metodą...
-
Study of prototype multi-pole non-salient field winding for high speed brushless synchronous generator
PublikacjaIn this paper a non-salient field winding for a brushless synchronous generator working with high speed in an autonomous energy generation system (e.g. airplane power grid) has been presented. A conception of a six-pole cylindrical-rotor with distributed field winding has been proposed. Comparison study of salient and prototype non-salient field winding has been carried out. Chosen simulation and measurement results of the generator...
-
Noise spectral density computation based on finite element model of piezoceramic sensor
PublikacjaThe high sensitivity with wide bandwidth is required for sensor applications in non-destructive testing (NDT). The sensitivity of piezoceramic sensors demands to minimize their noise especially thermal noise, polarisation noise and low frequency 1/f noise,which are the main sources of voltage or current fluctuation in this sort of sensors. For simplicity, only the piezoceramic part of sensor was under study. the theoretical and...
-
Szacowanie niepewności funkcji przetwarzania przetwornika LEM CT -5T metodą Monte Carlo
PublikacjaW referacie zaprezentowano metodologię szacowania niepewności funkcji przetwarzania przetwornika prądowego, na przykładzie przetwornika LEM CT-5T, przy zastosowaniu metody opartej na Przewodniku GUM z zastosowaniem prawa propagacji niepewności oraz metody numerycznej Monte Carlo. Przedstawiono szczegółową analizę doboru rozkładu wielkości wejściowej. W przypadku metody Monte Carlo dobór rozkładu wielkości wejściowych jest bardzo...
-
Szacowanie niepewności funkcji przetwarzania przetwornika LEM CT -5T metodą Monte Carlo
PublikacjaW referacie zaprezentowano metodologię szacowania niepewności funkcji przetwarzania przetwornika prądowego, na przykładzie przetwornika LEM CT-5T, przy zastosowaniu metody opartej na Przewodniku GUM, z zastosowaniem prawa propagacji niepewności oraz metody numerycznej Monte Carlo. Przedstawiono szczegółową analizę doboru rozkładu wielkości wejściowej. W przypadku metody Monte Carlo dobór rozkładu wielkości wejściowych jest bardzo...
-
Investigation of the thermal conductivity of λ gypsum using the hot wire method
Dane BadawczeAn experimental study was conducted to determine the thermal conductivity coefficient λ using the ‘hot wire’ method for a building material. Gypsum specimens measuring 400 x 60 x 50 mm were made for the experiment. Along the long axis of the model, an insulated resistance wire with a diameter of 0.2 mm was poured into the gypsum slurry in the centre...
-
DIAGNOSTYKA ŁOŻYSK SILNIKA INDUKCYJNEGO PRZY UŻYCIU POMIARU PRĄDU ZASILAJĄCEGO I WIBRACJI
PublikacjaW artykule przedstawione zostały wyniki badań diagnostycznych łożysk silnika indukcyjnego z zastosowaniem metody pomiaru prądu zasilającego oraz wibracji. Poruszone zostały problemy dotyczące poszukiwania nowej metody opartej na pomiarze i analizie prądu, która w znacznym stopniu ułatwiłaby szybkie i sprawne znalezienie uszkodzenia w maszynie, bez konieczności bezpośredniego dostępu do badanego urządzenia. Zaprezentowano rezultaty...
-
LIDAR data from a cliff measurement conducted in the vicinity of the town of Jastrzębia Góra on the Baltic Sea coast
Dane BadawczeMeasurement data were obtained during research related to the use of LiDAR observations to assess the stability of a coastal cliff. The collected information comes from measurements conducted in the vicinity of the town of Jastrzębia Góra on the Baltic Sea coast. The acquired point cloud constitutes a comprehensive set of data regarding the geometry...
-
The Indication Methods and Techniques of Urban Light Pollution
PublikacjaThe goal of this study is to review and categorize approaches and methods of facing urban light pollution. Probing various references and documents, the current practice focus on extracting and reviewing different types of urban light pollution detection, survey, and measurement to define a taxonomy of methods by instant comparison. The means of measurement and detecting this pollution include 14 most cited techniques that have...
-
Remote Monitoring of Environmental Pollutants
PublikacjaAtmospheric air quality is one of the key factors influencing human health. Air quality evaluation is not an easy task as the atmosphere is a complex system subjected to continuous changes in time. Observed progress in the development of measurement devices and technologies is fundamental for acquisition of more reliable information about condition and quality of atmospheric air. Unfortunately, this process leads to an increase...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 1281 mA. Sample J51, run #2.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 1098 mA. Sample J51, experiment run #2. The current is extremely high for this type of sample to accelerate ageing processes.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 1281 mA. Sample J51, run #3.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 1098 mA. Sample J51, experiment run #3. The current is extremely high for this type of sample to accelerate ageing processes.The images were taken...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,7 V at 1281 mA. Sample J51, run #1.
Dane BadawczeDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,7 V and discharged to 10 mV by constant current 1098 mA. Sample J51, experiment run #1. The current is extremely high for this type of sample to accelerate ageing processes.The images were taken...
-
The new version of contact-less method for localisation of catenary contact wire – theoretical assumption
PublikacjaThis article presents the theoretical basic of a new version of contact-less method for localising the catenary contact wires, using the advanced video techniques and image analysis. So far, contact line diagnostic systems exploited nowadays uses the contact measuring methods with special design current collector. This solutions make it impossible to measure the contact line geometry in a static way. The proposed measurement method...
-
High Frequency Harmonics Emission of Modern Power Electronic AC-DC Converters
PublikacjaModern AC/DC converters with bidirectional power flow employing PWM boost topology generate harmonic distortions of input current in relatively high frequency range tightly related to modulation carrier frequency. These frequencies and its multiples in typical applications are usually located in frequency range from single up to several of kHz. Increased harmonic emission in this frequency range can easily and harmfully influence...
-
ROSANNE Project: New Procedure for Noise Characterisation of Road Surfaces in Europe
PublikacjaROSANNE is a collaborative project in the 7th EU Framework Programme which aims at harmonising measurement methods for skid resistance, noise emission and rolling resistance of road pavements as a preparation for standardization. The project started in November 2013 and is developing and improving standards in the field of working group CEN/TC 227/WG 5. Regarding the influence of the pavement on the road traffic noise emission,...
-
Detection and time/frequency analysis of electric fields in the ground
PublikacjaThis paper sets out to detect and characterize electric fields in the ground (such as stray current fields) using a tandem time/frequency method of signal analysis. Results were obtained from investigations performed in the presence of a generated electric field with controlled variable characteristics, and in the presence of an electric field generated by a tramline. The analysis of measurement registers was performed using Short‐Time...