Filtry
wszystkich: 454
-
Katalog
- Publikacje 346 wyników po odfiltrowaniu
- Czasopisma 16 wyników po odfiltrowaniu
- Konferencje 37 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 24 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Kursy Online 4 wyników po odfiltrowaniu
- Wydarzenia 1 wyników po odfiltrowaniu
- Dane Badawcze 23 wyników po odfiltrowaniu
Wyniki wyszukiwania dla: bolted lap joint
-
Damage detection in a bolted lap joint using guided waves
PublikacjaThe paper presents the experimental investigation of guided waves application to the condition assessment of prestressed bolted connections and a concept of new quantitative indicator. The main goal of the research was the analysis of the influence of the contact conditions changes to the characteristics of a propagating disturbance. The experimental tests were carried out for a single bolted lap joint. The excitation and acquisition...
-
Diagnostics of bolted lap joint using guided wave propagation
PublikacjaThe paper presents numerical and experimental analyses of elastic waves propagation in a bolted lap joint. In experimental investigations condition assessment of the joint was performed with the use of symmetric waves excited by a piezoactuator. Numerical calculations were conducted in commercial finite element method software Abaqus. The influence of number of bolts and the value of the initial stress on recorded signals was examined....
-
Analysis of wave propagation in a bolted steel joint
PublikacjaThe paper presents results of numerical and experimental investigations of elastic wave propagation in a bolted single-lap joint. The research was carried out for both symmetric and antisymmetric Lamb wave modes. In experimental studies the PZT transducers were used to excite and register wave propagation signals. The controlled value of the torque during measurements was ensured by the use of high precision torque wrenches. Numerical...
-
Bolted Joint Monitoring Using the Elastic Wave Propagation
Publikacja -
Lamb wave propagation in a single lap adhesive joint
PublikacjaThe aim of the paper is the analysis of Lamb wave propagation in adhesive joints. The research was performed on a single lap adhesive joint of two steel plates. Two types of joints, namely an intact and with defect were considered. In experimental investigations the condition assessment of the joint was performed with the use of antisymmetric Lamb waves excited by a plate piezo actuators and measured by a laser vibrometer. Numeri-cal...
-
Lamb wave propagation in a single lap adhesive joint
Publikacja -
Preload monitoring in a bolted joint using Lamb wave energy
PublikacjaThe knowledge of the load in prestressed bolted connections is essential for the proper operation and safety of engineering structures. Recently, bolted joints have become an area of intensive research associated with non-destructive diagnostics, in particular in the context of wave propagation techniques. In this paper, a novel procedure of bolt load estimation based on the energy of Lamb wave signals was proposed. Experimental...
-
Research on assessment of bolted joint state using elastic wave propagation
PublikacjaThe work contains results of experimental investigation of elastic wave propagation in a bolted single-lap joint. Tests were carried out for the excitation perpendicular to the connection plane. In experimental studies, PZT transducers were used for both excitation and registration of ultrasonic waves. The analyses took into account varying contact conditions between the elements of the connection depending on the value of the...
-
Lamb wave-based monitoring of shear failure of an adhesive lap joint
PublikacjaThe paper presents a study on the elastic wave propagation in adhesive joints of steel plates subjected to tensile loading. A single lap joint was chosen for analysis because of its simplicity and plurality of applications. Experimental investigations consisted of the uniaxial extension of prepared specimens. Force and displacement values were recorded by a testing machine. Simultaneously, guided Lamb waves were excited and signals...
-
Modelling of elastic wave propagation in a bolted joint using a thin layer of shell elements
PublikacjaThere are many mathematical models describing the propagation of elastic waves through the imperfect boundary of two media. They were successfully applied to modelling of high frequency bulk waves and their interaction with local defects. On the other hand, the existing literature models of bolted connections ignore the aspect of imperfect connection between elements. Therefore, this paper presents the concept of application of...
-
Monitoring Steel Bolted Joints during a Monotonic Tensile Test Using Linear and Nonlinear Lamb Wave Methods: A Feasibility Study
PublikacjaThe structural integrity of steel bolted joints may be compromised due to excessive loading. Therefore, condition assessment and the detection of potential defects before they cause a failure have become a major issue. The paper is focused on the condition monitoring of a bolted lap joint subjected to progressive degradation in a tensile test. The inspection used Lamb waves propagated through the overlap area. Wave propagation...
-
Results from tests on bolted connection components for evaluation of friction coefficient in various contact conditions
PublikacjaThe main purpose of the work was the analysis and evaluation of the self-locking quality of a bolted joint covered with Xylan 1070 coating, with comparison to the classic bolts lubricated with Molykote compound during assembly. The second part of the work was the verification of the compliance of the bolts and nuts used in the installation with the ASME B1.1 norm.
-
Application of guided wave propagation in diagnostics of steel bridge components
PublikacjaEarly detection of potential defects and identification of their location are necessary to ensure safe, reliable and long-term use of engineering structures. Non-destructive diagnostic tests based on guided wave propagation are becoming more popular because of the possibility to inspect large areas during a single measurement with a small number of sensors. The aim of this study is the application of guided wave propagation in...
-
Experimentation, material modelling and simulation of bonded joints with a flexible adhesive
PublikacjaThe paper deals with material parameters identification of a flexible adhesive and the numerical simulation of its behaviour in a single lap bonded joint. The material modelling was based on the simple shear and tensile-shear laboratory tests of the bonded joints made of thin aluminium and polyurethane plates with the flexible adhesive Terostat MS 9360 manufactured by Henkel AG & Co. The adhesive was considered as a hyperelastic...
-
Wave Frequency Effects on Damage Imaging in Adhesive Joints Using Lamb Waves and RMS
PublikacjaStructural adhesive joints have numerous applications in many fields of industry. The gradual deterioration of adhesive material over time causes a possibility of unexpected failure and the need for non-destructive testing of existing joints. The Lamb wave propagation method is one of the most promising techniques for the damage identification of such connections. The aim of this study was experimental and numerical research on...
-
Experimental study of the impact of notches and holes made in the front edge of adherends on the properties of static and fatigue strength of adhesive joints
PublikacjaThe paper presents the results of experimental studies aimed at determining the effect of holes and notches at the front edge of adherends on the strength of adhesive joints. Single-lap joints made of S235JR steel sheets joined with Araldite 2014-2 epoxy adhesive were tested. Comparative tests of static strength in the shear test as well as high-cycle fatigue strength tests were carried out. Joints with three holes with a diameter...
-
Damage Imaging in Lamb Wave-Based Inspection of Adhesive Joints
PublikacjaAdhesive bonding has become increasingly important in many industries. Non-destructive inspection of adhesive joints is essential for the condition assessment and maintenance of a structure containing such joints. The aim of this paper was the experimental investigation of the damage identification of a single lap adhesive joint of metal plate-like structures. Nine joints with different defects in the form of partial debonding...
-
Fracture Surface Topography Parameters for S235JR Steel Adhesive Joints After Fatigue Shear Testing
PublikacjaThis paper presents the experimental results of a study investigating the effect of holes and notches made on the overlap ends on the strength of adhesive joints. Single-lap joints made of S235JR steel sheets bonded with Araldite 2024-2 epoxy adhesive were tested. For comparative reasons, static shear strength tests and high-cycle fatigue strength tests were performed. Adhesive-filled joints having three holes, each with a diameter...
-
Monitoring of single-side lap grinding with electroplated tools
PublikacjaThe results presented in the paper show that utilising microphones as audible sound sensors is a suitable approach for monitoring a single-side lap grinding process due to the low levels of noise generated by the drives of a machine tool. The results confirm that sound signal analysis is a feasible and relatively simple method to monitor a lap grinding process with the use of an audible sound sensor. Proposed method can be used...
-
New kinematic systems in single-sided lapping and their influence on lap wear
PublikacjaPrevious studies on one-sided lapping allow to state that not only parameters of lapping elements (i.e. properties of workpiece, abrasive grains and lapping plate) impact on a lapping efficiency. Influential are also kinematics and dynamics of the process. It is crucial to control an average velocity of lapping (v), a distribution of tangential acceleration (at), a nominal pressure (p), a lapping time (t) and disposal of workpiece...
-
Wear of electroplated diamond tools in lap-grinding of Al2O3 ceramic materials
PublikacjaCurrent development of modern products, together with ever-increasing demands for their operation and usage, necessitate the search for new processing methods. Abrasive machining is widely used in many industrial areas, especially for processing difficult-to-machine materials such as advanced ceramics. Grinding with lapping kinematics, also called lap-grinding, is still one of the innovative methods of abrasive processing being...
-
The use of Preston equation to determine material removal during lap-grinding with electroplated CBN tools
PublikacjaGrinding executed in a lapping configuration is an alternative finishing process benefiting from both grinding and free-abrasive machining, while minimizing the heat effect impact. Electroplated tools can be effectively used in different abrasive processes, including high-speed grinding, however, the assessment of machining performance over time is a key factor in their correct use to achieve satisfactory technological results....
-
3D Computer Model of the Hip Joint Cartilage
PublikacjaThis paper presents 3D computer model of the hip joint cartilage in the ANSYS program. Model is made on the basis of anatomy and collected data on the material constants of bone and cartilage components. Analysis and comparison of biochemical model, viscoelastic and molecular mixed - aggregation serves to facilitate the creation of the next model of reality, which could be used in the design of joint prostheses. The correctness...
-
Influence on micrograins size on the distance between the workpiece and the lap.
PublikacjaNa kształtowanie powierzchni docieranej główny wpływ ma błąd kształtu zastosowanego narzędzia. Intensywność docierania zależy od wielkości zastosowanych ziaren ściernych, które również wpływają na błędy kształtu przedmiotu. W referacie przedstawiono wyniki obliczeń odległości przedmiotu od powierzchni narzędzia w funkcji wielkości ziaren ściernych.
-
Medially positioned plate in first metatarsophalangeal joint arthrodesis
PublikacjaObjective The purpose of this study was to biomechanically compare the stability of first metatarsophalangeal (MTP1) joint arthrodesis with dorsally and medially positioned plates. Methods A physical model of the MTP1 joint consists of printed synthetic bones, a titanium locking plate and screws. In the experiments, samples with dorsally and medially positioned plates were subjected to loading of ground load character in a universal...
-
Annals of Joint
Czasopisma -
THE INFLUENCE OF MANUFACTURING OVERSIZING ON POSTWELDING DISTORTIONS OF THE FILLET WELDED JOINT
PublikacjaWelding proces is basic joining technique in shipbuilding. Such method generated welding distortions which cause a lot of problems during the manufacturing process. In the literature it is proposed wide spectrum of suggestions for a correct estimation of welding deformation in particular angular deformation in the fillet welded T joint. In the work influence of oversizing of weld on angular distortions of joint is presented basing...
-
The validation process of truss model with joint eccentricities
PublikacjaNowadays, due to the technological reasons in modern lightweight steel trusses, fabricated from cold-formed sections, positive eccentricities appear in the truss nodes, to induce additional forces truss chords. In order to account for the real load-carrying capacity of truss node area the steel structure research was conducted in scale 1:1. As a result of experimental research, the forms of deformation and strains of the walls...
-
Biomechanics of the medial meniscus in the osteoarthritic knee joint
PublikacjaBackground. Increased mechanical loading and pathological response of joint tissue to the abnormal mechanical stress can cause degradation of cartilage characteristic of knee osteoarthritis (OA). Despite osteoarthritis is risk factor for the development of meniscal lesions the mechanism of degenerative meniscal lesions is still unclear. Therefore, the aim of the study is to investigate the influence of medial compartment knee OA...
-
Possibilities for assesment of the angular distortion in Welded T-joint
PublikacjaSpawanie jest podstawową techniką łączenia elementów konstrukcji kadłuba statku. Procesowi temu towarzyszą odkształcenia spawalnicze, co przysparza dużo problemów wykonawczych. W pracy przedstawiono wpływ przewymiarowania spoiny pachwinowej na wielkość kątowych odkształceń złącza. Dokonano porównania wartości określonych na podstawie inżynierskich hipotez z wynikami otrzymanymi podczas prób laboratoryjnych.
-
Jaw biomechanics: Estimation of activity of muscles acting at the temporomandibular joint
PublikacjaThe aim of this study was to elaborate a method of estimation of activity of surface muscles acting at the temporomandibular joint of the healthy subjects by using a surface electromyography (EMG). The scope of this study involved testing chosen jaw motions (open, close, lateral deviation) and process of mastication occurring during eating food with different toughness (chewing gum, cereal and carrot) by using mixed sides, right...
-
Load carrying capacity of the eccentric joint in the truss made of open cross-sections
PublikacjaThe influence of eccentricity at intersections of truss members on the load carrying capacity of the truss joint is presented in the paper. The research truss elements were designed as cold-formed open cross section. Analytical calculations, numerical analysis and experimental research were conducted to reveal how the eccentricity affects the effort of material in the joint area. The results of analysis and investigations are compared...
-
The influence of temperature on properties of the polymer flexible joint used for strengthening historical masonries
PublikacjaA new method of repairing damaged structures by filling the cracks with a specially prepared elastomeric polymer mass has been recently proposed. This new and innovative technique, known as the Flexible Joint Method (FJM), is mainly dedicated to masonries and historical objects, where minimum intervention is permitted. The flexible joint bonds the disrupted elements and ensures further safe exploitation of a damaged structure....
-
Preliminary experimental research on stability of truss' joint with positive eccentricity
PublikacjaRecently, a very large interest in lightweight steel structures made from cold-formed sections has been noticeable. In the design practice, a large emphasis is put on rational shaping of both the thin-walled elements and constructions designed on them. The aim of this paper is to present the methodology for preparation of experimental research that model the behaviour of members in trusses made of cold-formed sections with positive...
-
Experimental investigation of joint with positive eccentricity in CFS truss
PublikacjaDue to technological restrictions, in the case of trusses made of CFS open cross-sections, positive eccentricities in the truss joints have become very frequent. Therefore studies concerning the load-bearing capacity of truss joints with positive eccentricity were undertaken. It was assumed that the resistance of cold-formed steel (CFS) open cross-section truss joints located on compression chords and with positive eccentricity...
-
On joint order and bandwidth selection for identification of nonstationary autoregressive processes
PublikacjaWhen identifying a nonstationary autoregressive process, e.g. for the purpose of signal prediction or parametric spectrum estimation, two important decisions must be taken. First, one should choose the appropriate order of the autoregressive model, i.e., the number of autoregressive coefficients that will be estimated. Second, if identification is carried out using the local estimation technique, such as the localized version of...
-
Bone & Joint Research
Czasopisma -
Bone & Joint Journal
Czasopisma -
Joint Commission: The Source
Czasopisma -
JOINT BONE SPINE
Czasopisma -
Bone & Joint Open
Czasopisma -
An in situ technique for the assessment of adhesive properties of a joint under load
PublikacjaSlow crack propagation in adhesive bonded joints has been characterised using an asymmetric wedge test. Crack position was evaluated from strain gauge measurements, both in the debonded partof the joint and in the bonded zone. Test temperature was changed during loading, giving insight into bond evolution. The technique allows accurate, and virtually continuous, determination of crack position to be made, and therefore the evaluation...
-
Mechatronic Design Towards Investigation of the Temporo-Mandibular Joint Behaviour
PublikacjaA significant problem of the temporo-mandibular joint (TMJ) research is lack of data concerning geometry and position of TMJ discs. It leads to necessity of developing a driving method of the process optimization, which is based on chosen techniques of mechatronic design. In particular, the latter concerns a technique of experimentally supported virtual prototyping. On this stage, the research is characterized by well-verified...
-
The influence of a change in the meniscus cross-sectional shape on the medio-lateral translation of the knee joint and meniscal extrusion
PublikacjaObjective The purpose of this study was to evaluate the influence of a change in the meniscus cross sectional shape on its position and on the biomechanics of a knee joint. Methods One main finite element model of a left knee joint was created on the basis of MRI images. The model consisted of bones, articular cartilages, menisci and ligaments. Eight variants of this model with an increased or decreased meniscus height were then...
-
BUILDING SMARTSLOW_SLOWSMART IN NOWY PORT- THE MULIDISICIPLINARY EDUCATIONAL EXPERIMENT OF JOINT DESIGN STUDIO
PublikacjaThis study presents the results of students’ work from Hafen City University in Hamburg and Gdansk University of Technology, carried out as part of a joint studio dealing with Nowy Port problem area. It refers to the methodology and design proposals, as well as to individual projects of students from Gdansk University of Technology - Spatial Management and Architecture. The aim of this study is to present framework project guidelines...
-
Engineering and Management of Space Systems (EMSS) - an international joint Master's double-degree program
PublikacjaDynamic development of the space sector of European, and especially of Polish and German economies results in a necessity for suitable Higher Education Institution graduates. The increasing digitization, distribution and networking of technical systems leads to the necessity of a degree programme teaching “the systems view” and “interdisciplinarity” methods and skills. Furthermore, it is necessary to consider the entire life cycle...
-
THE DETERMINATION OF ABRASION RESISTANCE OF SELECTED BIOMATERIALS FOR THE FRICTION PAIRS IN THE HIP JOINT ENDOPROSTHESIS
PublikacjaThe key requirement for the modern endoprosthesis is high durability of the friction components, which results in long and trouble-free operation in the human body. The durability of currently used endoprosthesis is often limited by tribological wear processes of friction components (e.g. between the head and the acetabular component in a hip joint endoprosthesis) [8, 19, 23, 24]. In order to compare the tribological wear, tribological...
-
Joint Commission perspectives. Joint Commission on Accreditation of Healthcare Organizations
Czasopisma -
Matrix-based robust joint fingerprinting and decryption method for multicast distribution of multimedia
PublikacjaThis paper addresses the problem of unauthorized redistribution of multimedia content by malicious users (pirates). The solution proposed here is a new joint fingerprinting and decryption method which meets the requirements for both imperceptibility and robustness of fingerprints and scalability in terms of design and distribution of fingerprinted multimedia content. The proposed method uses a simple block cipher based on matrix...
-
Study on Microstructure and Mechanical Properties of Laser Welded Dissimilar Joint of P91 Steel and INCOLOY 800HT Nickel Alloy
PublikacjaThis investigation attempts to explore the weld characteristics of a laser welded dissimilar joint of ferritic/martensitic 9Cr-1Mo-V-Nb (P91) steel and Incoloy 800HT austenitic nickel alloy. This dissimilar joint is essential in power generating nuclear and thermal plants operating at 600–650 °C. In such critical operating conditions, it is essential for a dissimilar joint to preserve its characteristics and be free from any kind...
-
Impact of interface heterogeneity on joint fracture
PublikacjaThe effects of heterogeneities (weak zones in particular) inadhesive joints and their importance on overall fracture propertiesare relatively unknown, but doubtlessly they may be crucial inmany applications. Using a model heterogeneous adhesive bond,represented by a given mixture of regions of strong and weakadhesion, we have studied the influence of interface variabilityon overall fracture energy (global energy release rate)....
-
Underwater welded joint properties investigation
PublikacjaPrzeprowadzono badania mikro- i makroskopowe złączy spawanych typu implant wykonanych pod wodą metodą lokalnej komory suchej. Wyniki badań świadczą o tym, że w SWC badanych złączy tworzą się kruche struktury hartownicze, które są odpowiedzialne za zwiększoną skłonność stali o podwyższonej wytrzymałości do tworzenia pęknieć zimnych. Analiza rozkładów twardości złączy implant również potwierdza istnienie szkodliwego wpływu środowiska...
-
Self-Organising map neural network in the analysis of electromyography data of muscles acting at temporomandibular joint.
PublikacjaThe temporomandibular joint (TMJ) is the joint that via muscle action and jaw motion allows for necessary physiological performances such as mastication. Whereas mandible translates and rotates [1]. Estimation of activity of muscles acting at the TMJ provides a knowledge of activation pattern solely of a specific patient that an electromyography (EMG) examination was carried out [2]. In this work, a Self-Organising Maps (SOMs)...
-
Analysis of muscles behaviour. Part II. The computational model of muscles group acting on the elbow joint
PublikacjaThe purpose of this paper is to present the computational model of muscles' group describing the movements of flexion/extension at the elbow joint in the sagittal plane of the body when the forearm is being kept in the fixed state of supination/pronation. The method ofevaluating the muscle forces is discussed in detail. This method is the basis for the quantitative and qualitative verification of the proposed computational model...
-
Investigation on polypropylene friction stir joint: effects of tool tilt angle on heat flux, material flow and defect formation
PublikacjaTool tilt angle (TTA) is a critical factor that can control material flow in polymeric materials' friction stir joining (FSJ). This study selected a TTA range between 0° to 4° for FSJ of polypropylene (PP) polymer sheet. A modified computational fluid dynamic (CFD) technique was implemented to gain a deep understanding of the effects of TTA during FSJ of PP. The PP joint's internal flow, defect formation, heat generation, and tensile...
-
Influence of the notch rounding radius on estimating the elastic notch stress concentration factor in a laser welded tee joint
PublikacjaIn recent years an increased interest of industry in sandwich-type metal structures can be observed. These structures consist of thin plates of 2.5 mm in thickness separated by stiffeners of different shapes and forms. Welds joining the plates and stiffeners are made on the outer side of the plates using laser welding technique. A locally focused source of heat causes the plate to melt creating a very narrow and elongated joint....
-
INFLUENCE OF TACK WELDS DISTRIBUTION AND WELDING SEQUENCE ON THE ANGULAR DISTORTION OF TIG WELDED JOINT
PublikacjaIn this paper the influence of tack welds distribution and welding sequence on angular distortion of the Tungsten Inert Gas (TIG) welded joint was tested. Additionally, the effect of welding current on angular distortion was assessed. For research X2CrTiNb18 (AISI 441) stainless steel (2.5 mm thick) was chosen. During research specimens were prepared with different distributionsof tack...
-
The influence of reinforcement on load carrying capacity and cracking of the reinforced concrete deep beam joint
PublikacjaThe paper presents the results of experimental research of the spatial reinforced concrete deep beam systems orthogonally reinforced and with additional inclined bars. Joint of the deep beams in this research was composed of the longitudinal deep beam with a cantilever suspended at the transversal deep beam. The cantilever deep beam was loaded throughout the depth and the transversal deep beam was loaded at the mid-span by longitudinal...
-
CTOD designation for WM and HAZ in butt joint made from S460 ML steel, Expertise No. WOiO/II/82/2015
PublikacjaTypical (normative) testing of materials and/or welded joints do not answer on all questions about material or welded joint properties. In ship building and off-shore sectors, many strucures requires materials and joint with higher than typical fatigue resistance. Imact tests, which are carried out during welding technology qualification, gives answer about ductility, CTOD tests results about material or welded joint ability to...
-
Bulletin of the Hospital for Joint Diseases
Czasopisma -
Journal of Arthroscopy and Joint Surgery
Czasopisma -
Joint Diseases and Related Surgery
Czasopisma -
Journal of Bone and Joint Infection
Czasopisma -
Joint time–frequency analysis of electrochemical noise
Publikacja -
Modeling knee joint endoprosthesis mode of deformation
Publikacja -
TRUSS JOINT WITH POSITIVE ECCENTRICITY EXPERIMENTAL RESEARCH
PublikacjaDue to the technological reasons in modern lightweight steel trusses, fabricated from cold- formed sections, positive eccentricities appear in the truss nodes what induce additional forces in the truss chords. To account for the real load-carrying capacity of truss node area the steel structure research in scale 1:1 were conducted. The experiments consisted of two parts: preliminary and proper one, when conclusions from...
-
Human hip joint lubrication for permeable cartilage
PublikacjaPraca przedstawia pewien model obliczeń wartości sił tarcia zapisany w ortogonalnych sferycznych i innych krzywoliniowych układach współrzędnych dla hydrodynamicznego, niesymetrycznego przepływu cieczy synowialnej o własnościach nienewtonowskich i zmiennej lepkości w szczelinie stawu biodrowego człowieka z uwzględnieniem zmian losowych. Według informacji autora tak przedstawiony model nie był do tej pory rozpatrywany w pracach...
-
Strength assessment of a version of joint of sandwich panels
PublikacjaW pracy przedstawiono propozycję optymalizacji wariantu połączenia doczołowego stalowych paneli typu ''sandwich''. Przedstawiono wyniki analizy numerycznej rozkładów naprężeń dla wielu wariantów geometrii proponowanego połączenia.
-
Pressure and capacity in hip joint afte injury.
PublikacjaPraca przedstawia zarys analitycznego wyprowadzenia równania Reynoldsa do wyznaczania rozkładów wartości ciśnienia w szczelinie sferycznego stawu biodrowego człowieka po udarze w nieustalonym ruchu impulsywnym. W wyprowadzonym modelu uwzględniono lepkosprężyste właściwości cieczy synowialnej oraz stochastyczny opis chropowatości chrząstki stawowej. Numeryczne wartości ciśnienia wyznaczono w programie Mathcad 2001 przy wykorzystaniu...
-
On the joint time-frequency characteristics of chemical oscillations
PublikacjaZaprezentowano rezultaty analizy czasowo-częstotliwościowej rejestrów potencjałowych oscylacyjnej reakcji Biełousowa-Żabotyńskiego (BŻ). Wybraną reprezentację czasowo-częstotliwościową w postaci algorytmu STFT zastosowano do analizy typowych przebiegów reakcji BŻ, prowadzonej w układzie zamkniętym. Zaprezentowano spektrogramy STFT ukazujące czasowo-częstotliwościową strukturę oscylacji regularnych, mieszanych i chaotycznych. Na...
-
Towards classification of patients based on surface EMG data of temporomandibular joint muscles using self-organising maps
PublikacjaThe study considers the need for an effective method of classification of patients with a temporomandibular joint disorder (TMD). The self-organising map method (SOM) was applied to group patients and used together with the cross-correlation approach to interpret the processed (rectified and smoothed by using root mean square (RMS) algorithm) surface electromyography signal (sEMG) obtained from testing the muscles (two temporal...
-
Unsupervised Learning for Biomechanical Data Using Self-organising Maps, an Approach for Temporomandibular Joint Analysis
PublikacjaWe proposed to apply a specific machine learning technique called Self-Organising Maps (SOM) to identify similarities in the performance of muscles around human temporomandibular joint (TMJ). The performance was assessed by measuring muscle activation with the use of surface electromyography (sEMG). SOM algorithm used in the study was able to find clusters of data in sEMG test results. The SOM analysis was based on processed sEMG...
-
The resilient city in architectural engineering education: a joint design studio between Gdańsk and Chalmers universities of technology
PublikacjaChallenges to society, such as those posed by climate change require a new approach to the education of the engineer-architect. Contemporary solutions should serve future generations and that is why the idea of the resilient city should be discussed and implemented, both in theory and in practice. It is necessary to teach students to design urban structures in such a way that they are resilient to dynamically changing conditions....
-
Effects of FSW Tool Plunge Depth on Properties of an Al-Mg-Si Alloy T-Joint: Thermomechanical Modeling and Experimental Evaluation
PublikacjaOne of the main challenging issues in friction stir welding (FSW) of stiffened structures is maximizing skin and flange mixing. Among the various parameters in FSW that can affect the quality of mixing between skin and flange is tool plunge depth (TPD). In this research, the effects of TPD during FSW of an Al-Mg-Si alloy T-joint are investigated. The computational fluid dynamics (CFD) method can help understand TPD effects on FSW...
-
Study on Microstructure-Property Relationship of Inconel 617 Alloy/304L SS Steel Dissimilar Welds Joint
PublikacjaWelding of Inconel 617 (IN617) alloy and austenitic 304L SS steel has been attempted using the autogenous Laser Beam Welding (LBW) process. Characterization of dissimilar weldments was performed on either side of the fusion boundaries. The metallographic results showed that the inhomogeneous microstructure formation for weld metal contained columnar and cellular dendrites near the interface, whilst the columnar, cellular and equiaxed...
-
A Wideband Rotary-Joint-Free H-Plane Horn Antenna With 360° Steerable Radiation Pattern Using Gap Waveguide Technology
PublikacjaConsidering the limitations of electronically steerable antennas such as limited steering span, gain degradation for large steering angles, complexity, and cost, this article is focused on the design of a simple mechanically steerable H-plane horn antenna. It is shown that since there is no need for an electrical connection between the top and bottom sections of a gap waveguide (GWG), if a sectoral horn is properly designed and realized...
-
Intelligent artificial joint and regeneration problems in articular joints
PublikacjaPraca przedstawia zasady działania inteligentnych sztucznych stawów biodrowych człowieka oraz problemy regeneracji chrząstek stawowych w stawach naturalnych człowieka. Postuluje się wagę podjętych badań w powyższym problemie.Zwrócono uwagę na problemy związane ze sterowaniem własności sztucznych stawów biodrowych oraz z identyfikacją impulsów przekazywanych naturalnym połączeniom stawowym człowieka.
-
A fair distribution scheme for joint fingerprinting and decryption methods= Sprawiedliwy schemat dystrybucji dla metod łącznego osadzania odcisku palca oraz deszyfracji
PublikacjaThe paper addresses the fairness of the security provided by digital fingerprinting methods. It was noted that the digital fingerprinting techniques are designed primarily to protect service providers against the actions of malicious users, while honest users remain vulnerable to acts of malicious providers. The paper describes the customer's rights problem and the unbinding problem, which also apply to joint fingerprinting and...
-
RMS-based damage identification in adhesive joint between concrete beam and steel plate using ultrasonic guided waves
PublikacjaAdhesive joints have numerous applications in many branches of industry, such as civil engineering, automotive, aerospace and shipbuilding. As with most structural elements, adhesive joints can experience any damage mechanism, which induces the need for diagnostic testing. Ultrasonic waves are widely used for non-destructive inspection of many structures and their elements, including adhesive joints. Guided wave propagation method...
-
Monitoring of crosslinking of a DGEBA-PAMAM adhesive in composite/aluminium bonded joint using mechanical and ultra-sound techniques
PublikacjaAdhesive cure is an important and determining aspect of strength and stability of bonded structures. Crosslinking of the polymer leads to the adhesive strength, stiffness and durability. Depending on the resin and curing agent used, cure time can vary from minutes to weeks, even then 100% crosslinking not being guaranteed. Standard methods based on dynamic mechanical analysis (DMA) or calorimetric techniques (DSC, DTA) are valuable...
-
3D model of osteoarthritic (OA) knee joint for analysis of the medial meniscus biomechanics - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. In the OA model thickness of articular cartilage and material parameters of the cartilage and menisci were reduced to simulate degenerative changes in the...
-
Joint foreign ownership and global value chains effects on productivity: a comparison of firms from Poland and Germany
PublikacjaPurpose The study aims to examine the joint effects of foreign ownership (FO) and involvement in global value chains (GVCs) on the productivity performance of firms from a catching-up country (Poland) and a leader economy (Germany). Design/methodology/approach The authors use micro-level data on firms combined with several sector-level GVC participation measures. The authors investigate whether the link between productivity and...
-
TOO4TO Course Module: Circular Economy, Economics & Sustainability, Sustainable Production - Joint module
Kursy Online -
Project of hip joint endoprothesis for an individual patient with materials selection
PublikacjaThis work includes the hip replacement design, based on the patient's medical records, the description of creation process and materials used for individual components.
-
Joint optimization of anycast and unicast flows in survivable optical networks
PublikacjaZnane z literatury dotychczasowe prace związane z ochroną ruchu przed awarią elementów sieci dotyczą transmisji typu unicast (jeden-do-jednego). Niniejszy artykuł jest pierwszym prezentującym rozwiązanie jednoczesnej ochrony transmisji anycast (jeden-do-jednego-z-wielu) oraz transmisji unicast. Proponowane podejście wykorzystuje model ochrony ścieżki (ang. path protection). Zagadnienie zostało sformułowane w postaci odpowiedniego...
-
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublikacjaThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...
-
Hybrid SONIC: joint feedforward–feedback narrowband interference canceler
PublikacjaSONIC (self-optimizing narrowband interference canceler) is an acronym of a recently proposed active noise control algorithm with interesting adaptivity and robustness properties. SONIC is a purely feedback controller, capable of rejecting nonstationary sinusoidal disturbances (with time-varying amplitude and/or frequency) in the presence of plant (secondary path) uncertainty. We show that although SONIC can work reliably without...
-
Friction forces for human hip joint at a naturally permeable cartilage
PublikacjaNiniejsza praca omawia różne rodzaje sił tarcia występujących w szczelinach stawów człowierka. W artykule dokonano analizy kilku ważnych czynników wpływających na wartości sił tarcia występujących w stawach człowieka. Rozważa się siły tarcia wywołane klasycznym hydrodynamicznym smarowaniem, wzmożonym hydrodynamicznym smarowaniem, wyciskaniem a także przesączaniem cieczy synowialnej do i z porowatej warstwy chrząstki stawowej.
-
Periodic and impulsive lubrication of hip joint with stochastic rough surface.
PublikacjaNiniejsza praca przedstawia porównanie wartości nośności uzyskanych numerycznie dla niestacjonarnego smarowania impulsywnego oraz niestacjonarnego smarowania periodycznego sferycznego stawu biodrowego człowieka. W obu przypadkach przyjęto, że smarująca ciecz synowialna ma własności lepkosprężyste a występy chropowatych powierzchni chrząstki stawowej zmieniają się losowo. Charakterystyki zmiennych w czasie rozkładów wartości ciśnienia...
-
Impulsive lubrication of hip joint for hypo-elastic cartilage model
PublikacjaPraca rozwiązuje problem smarowania stawu biodrowego człowieka w warunkach niestacjonarnych z uwzględnieniem hypo-sprężystych (pod-sprężystych) właściwości odkształcalnej szkieletu chrząstki stawowej. Prezentowane są rozkłady wartości ciśnienia hydrodynamicznego oraz zmienne w czasie rozkłady wartości sił nośnych.
-
Asperities and deformations of hyper elastic joint cartilages in cultivation aspects
PublikacjaPraca opisuje wyniki badań procesu hodowli chrząstki stawowej w bioreaktorze podczas nieustalonego laminarnego przepływu nienewtonowskiej biologicznej cieczy odżywczej wokół chrząstki spoczywającej na rusztowaniu bioreaktora. Badania takie wymagają eksperymentalnego pomiaru chropowatości powierzchni chrząstki.
-
Assessment of the Relationship between the Shape of the Lateral Meniscus and the Risk of Extrusion Based on MRI Examination of the Knee Joint
PublikacjaBackground Meniscus extrusion is a serious and relatively frequent clinical problem. For this reason the role of different risk factors for this pathology is still the subject of debate. The goal of this study was to verify the results of previous theoretical work, based on the mathematical models, regarding a relationship between the cross-section shape of the meniscus and the risk of its extrusion. Materials and Methods Knee...
-
P92 steel and inconel 617 alloy welds joint produced using ERNiCr-3 filler with GTAW process: Solidification mechanism, microstructure, mechanical properties and residual stresses
PublikacjaThe objective of the current study was to analyse the microstructure, mechanical characteristics, and residual stresses of a dissimilar welded joint (DWJ) made of P92 steel and the Inconel alloy 617 (IN617) using the gas tungsten arc welding (GTAW) method. The ERNiCr-3 filler was selected to produce the conventional V groove (VG) and narrow V groove (NVG) butt joint. The filler deficient zones in the weldments, such as the filler...
-
Archives of Bone and Joint Surgery-ABJS
Czasopisma -
3D intact knee model used in analysis of the medial meniscus biomechanics in the osteoarthritic knee joint - input text file for computation
Dane BadawczeThe finite element method was used to simulate the stance phase of the gait cycle. An intact knee model with original geometry and material parametetrs was prepared based on magnetic resonance scans of the left knee joint of a healthy volunteer. The file was created in Abaqus 6.14-2, but can be read in a text editor.
-
Effect of Pin Shape on Thermal History of Aluminum-Steel Friction Stir Welded Joint: Computational Fluid Dynamic Modeling and Validation
PublikacjaThis article studied the effects of pin angle on heat generation and temperature distribution during friction stir welding (FSW) of AA1100 aluminum alloy and St-14 low carbon steel. A validated computational fluid dynamics (CFD) model was implemented to simulate the FSW process. Scanning electron microscopy (SEM) was employed in order to investigate internal materials’ flow. Simulation results revealed that the mechanical work...
-
TOO4TO Course Module: Circular Economy, Economics & Sustainability, Sustainable Production - Joint module - 2023
Kursy Online -
A Scoping Review of the Use of Pioglitazone in the Treatment of Temporo-Mandibular Joint Arthritis
Publikacja -
Non-Newtonian lubrication of human hip joint for unsteady impulsive motion
PublikacjaTematem niniejszej pracy są parametry smarowania lepkosprężystą cieczą synowialną stawu biodrowego człowieka w czasie kilku, kilkunastu a nawet kilkudziesięciu mikrosekund po doznanym urazie. W niniejszej pracy rozpatruje się urazy wywołujące zmniejszenie lub zwiększenie wysokości i zmiany kształtu szczeliny stawu, które to zmiany po pewnym określonym czasie po doznanym urazie mogą zanikać. W konsekwencji takich urazów i to w...
-
Application of acoustic emission metod for measurement of joint gap and cartilage surfaces
PublikacjaW artykule przedstawiono zastosowanie emisji akustycznej do lokalizacji wczesnych uszkodzeń stawu biodrowego lub kolanowego człowieka. Ponadto metoda ta służy do pomiaru wysokości szczeliny stawu oraz struktury geometrycznej powierzchni chrząstki stawowej. Jest to metoda nieinwazyjna. Pomiary metodą emisji akustycznej stosujemy na ogół w materiałach, w których energia sprężysta zmienia się nagle. Takie zmiany energii mogą być...