Filtry
wszystkich: 3159
wybranych: 1571
-
Katalog
- Publikacje 1571 wyników po odfiltrowaniu
- Czasopisma 45 wyników po odfiltrowaniu
- Konferencje 2 wyników po odfiltrowaniu
- Osoby 45 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Kursy Online 29 wyników po odfiltrowaniu
- Wydarzenia 10 wyników po odfiltrowaniu
- Dane Badawcze 1456 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: passive films
-
Calibration of POCIS and PASSIL passive samplers – influence of humic acids
Publikacja -
Incorporation of nitrogen in diamond films - A new way of tuning parameters for optical passive elements
PublikacjaThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy...
-
Incorporation of nitrogen in diamond films – A new way of tuning parameters for optical passive elements
PublikacjaThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM), confocal...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublikacjaThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
passive spice networks from non-passive data
PublikacjaArtykuł przestawia technike generacji schematow zastepczych w formacie SPICE dla pasywnych układów mikrofalowych. Wynikowy schemat zastepczy ma zagwarantowana pasywnosc. Schematy zastepcze powstaja na podstawie symulacji lub pomiarow w dziedzinie czestotliwosci i moga byc wykorzystane do symulacji w dziedzinie czasu.
-
Passive sampling
PublikacjaPrzedstawiono możliwości wykorzystania technik pasywnych (opartych na swobodnym ruchu cząsteczek analitu do medium zatrzymującego) w analityce środowiskowej. Omówiono przykłady wykorzystania zarówno organizmów żywych (biomonitoring) jak i urządzeń pasywnych do pobierania próbek analitów z badanego medium (powietrze, woda, gleba).
-
Application of the PASSIL technique for the passive sampling of exemplary polar contaminants (pharmaceuticals and phenolic derivatives) from water
Publikacja -
Passive sonar with cylindrical array
PublikacjaArtykuł prezentuje sposób wykorzystania sonaru aktywnego z anteną cylindryczną do nasłuchu pasywnego podwodnych źródeł dźwięku. Wykazano, że wykrycie źródła dźwięku i określenie jego namiaru może być zrealizowane bez zmian konstrukcji odbiornika. Wymagana jest jedynie zmiana algorytmów przetwarzania sygnałów w beamformerze. Wykazano również, że w celu zwiększenia dokładności namiaru można zastosować wysokorozdzielcze metody estymacji...
-
Imaging forms in passive sonars
PublikacjaReferat jest kontynuacją tematyki organizacji zobrazowań we współczesnych systemach hydrolokacyjnych przedstawionej w referacie zaproszonym na ubiegłorocznym OSA dla systemów aktywnych. Tym razem dotyczy organizacji zobrazowań w systemach pasywnych. W praktyce, prócz prostych systemów nasłuchu i rejestracji dźwięków podwodnych, używanych przez badaczy fauny wodnej czy oceanografów, systemy pasywne są wykorzystywane w marynarkach...
-
Advances in passive sampling in environmental studies
PublikacjaDozymetria pasywna stanowi użyteczne narzędzie wykorzystywane w monitoringu środowiskowym. W pracy zostały zawarte nowe rozwiązania i udoskonalenia istniejących próbników pasywnych oraz praktyczne ich wykorzystanie w monitoringu środowiskowym.
-
Electrochemical analysis of aluminium passive layer
PublikacjaZbadano proces pękania warstwy pasywnej na aluminium dla liniowo narastających naprężeń rozciągających oraz różnych warunków elektrochemicznych. Badania prowadzono w 0.1M NaCl metodą dynamicznej elektrochemicznej spektroskopii impedancyjnej przy różnych poziomach polaryzacji anodowej. Określono progową wartość naprężeń, przy której następowało zniszczenie warstwy pasywnej wskutek działania sił rozciągających.
-
A comparative study of the performance of passive samplers
PublikacjaPodstawowym celem podjętych badań było porównanie pracy dozymetrów pasywnych wykorzystywanych na etapie izolacji i wzbogacania lotnych związków organicznych z powietrza atmosferycznego na terenie aglomeracji Trójmiejskiej. Jako próbniki do pobierania próbek analitów zastosowano komercyjne dozymetry pasywne typu dyfuzyjnego (Radiello i Orsa 5) oraz dozymetry typu permeacyjnego własnej konstrukcji wyposażone w półprzepuszczalną membranę...
-
Antimicrobial properties of chitosan solutions, chitosan films and gelatin-chitosan films
PublikacjaThe antimicrobial properties of chitosan solutions and films against selected bacteria and the effect of chitosan incorporation into gelatin films were studied. The bactericidal effect of chitosan solutions increased with time and temperature of sample incubation. Two psychrotrophic strains Pseudomonas fluorescens and Listeria innocua were more sensitive to chitosan than mesophilic strains Escherichia coli and Staphylococcus aureus....
-
Application of passive sampling technique for monitoring of BTEX concentration in urban air: Field comparison of different types of passive samplers
PublikacjaW efekcie przeprowadzonych badań potwierdzono przydatności techniki dozymetrii pasywnej wykorzystywanej na etapie izolacji i wzbogacania analitów do uzyskania informacji o poziomie stężeń zanieczyszczeń z grupy BTEX w powietrzu atmosferycznym na terenie aglomeracji Trójmiejskiej. Dodatkowo, porównano wyniki oznaczeń uzyskanych z wykorzystaniem dwóch typów dozymetrów pasywnych.
-
A new approach in the calibration of passive samplersA new approach on the calibration of passive dosimeters for studies of indoor air (....--------ROZBIEŻNOŚĆ TYTUŁÓW-------------------------------------
PublikacjaPrzedstawiono problematykę kalibracji próbników pasywnych wykorzystywanych w Katedrze Chemii Analitycznej Wydz. Chemicznego PG do monitoringu jakości powietrza wewnętrznego. Proponowane podejście pozwala na oszacowanie wartości stałych kalibracyjnych, a tym samym oznaczenia stężeń związków od heksanu do dodekanu. Tak więc permeacyjne dozymetry pasywne mogą być wykorzystane w analogicznym zakresie jak próbniki aktywne.
-
Visualisation forms in passive sonar with towed array
PublikacjaArtykuł dotyczy organizacji zobrazowań na monitorach modernizowanego w KSEM sonaru pasywnego z długą, holowaną za rufą okrętu, anteną akustyczną. We wprowadzeniu opisano strukturę takiego sonaru oraz sposób pozyskiwania i charakter odbieranych sygnałów jako podstawę organizowania zobrazowań efektów nasłuchu. Dalej opisano inne czynniki wpływające na organizację obrazów na monitorach sonaru tzn. zadania operatorów, organizację i...
-
Interactions using passive optical proximity detector
PublikacjaIn this paper we evaluated the possible application of a passive, optical sensor as an interface for human-smart glasses interactions. The designed proximity sensor is composed of set of photodiodes and the appropriate hardware and software components. First, experiments were performed for the estimations of such parameters as distance to an object, its width and velocity. Achieved results were satisfactory. Therefore, next, a...
-
Passive samplers in indoor air quality control
PublikacjaPrzedstawiono wyniki badań jakości powietrza wewnętrznego w 12 wybranych mieszkaniach usytuowanych na terenie aglomeracji Trójmiejskiej z wykorzystaniem techniki pasywnej (dozymetria pasywna typu permeacyjnego) oraz techniki dynamicznej (rurki sorpcyjne wypełnione sorbentem Tenax TA). Wykorzystując nowe podejście do sposobu kalibracji dokonano monitoringu zarówno poszczególnych lotnych związków organicznych jak i sumarycznej zawartości...
-
Passive sampling techniques for monitoring pollutants in water
PublikacjaPraca przeglądowa poświęcona technice dozymetrii pasywnej. Omówiono charakterystykę wybranych próbników pasywnych wykorzystywanych w analityce zanieczyszczeń wody. Ponadto przedstawiono zalety i wady technik pasywnych oraz opisano obszar praktycznego zastosowania próbnikow pasywnych.
-
Mathemathical model of radial passive magnetic bearing
PublikacjaIn the article mathematical radial model of passive magnetic bearings to ocean engineering units has been presented. The units application in underwater thrusters should increase propulsion systems durability and gives lower maintenance costs. The rotor of electric motor is hanging in magnetic field taken from radial passive magnetic bearings. However axial direction maintenance must be controlled with electromagnets and their...
-
Starch-clay nanocomposite films
PublikacjaStarch is a natural polymer which, due to its renewability, biodegrability, availability and a relatively low cost, has a high potential for applications in biodegradable materials. However, because of its hydrophilic nature, the number of commercially available starch-based products is still limited. Recently, starch-based nanocomposites with the addition of clay minerals as nanofillers have given rise to large-scale improvements...
-
Thin LSFO films for bolometers
PublikacjaPrzedstawiono metodę produkcji oraz temperaturowe zależności rezystancji cienkich warstw niestechiometrycznych tlenków (La,Sr)FeO3 (LSFO) przeznaczonych do zastosowań na detektory podczerwieni
-
Application of passive samplers in monitoring of organic constituents of air
PublikacjaTechnika dozymetrii pasywnej - znana od ponad 100 lat - cieszy się ciągłym zainteresowaniem i jest często wykorzystywana w różnych badaniach środowiskowych. Z powodu swej prostoty, różnorodności rozwiązań konstrukcyjnych i możliwości wykorzystania różnych technik oznaczeń końcowych, technika dozymetrii pasywnej może być zastosowana zarówno do oznaczeń związków organicznych jak i nieorganicznych, obecnych zarówno w powietrzu wewnętrznym,...
-
Algorithms for passive detection of moving vessels in marine environment
Publikacja -
Passive sampling and/or extraction techniques in environmental analysis: a review
PublikacjaThe current state-of-the-art of passive sampling and/or extraction methods for long-term monitoring of pollutants in different environmental compartments is discussed in this review. Passive dosimeters that have been successfully used to monitor organic and inorganic contaminants in air, water, sediments, and soil are presented. The application of new approaches to the determination of pollutants at the sampling stage is discussed....
-
Application of Passive Samplers in Monitoring of Organic Constituents of Air
PublikacjaThe principles of passive dosimetry, which has been known for over 100 years, are finding an ever increasing use in analytical practice and are being used as a convenient technique for isolation and enrichment of analytes from various environmental media. Due to its simplicity, a variety of designs, as well as the possibility of using a number of different final determination techniques, passive dosimetry has been applied in...
-
Application of passive sampling techniques for monitoring the aquatic environment
PublikacjaDozymetry pasywne są coraz powszechniej stosowanym narzędziem do pobierania próbek analitów ze środowiska wodnego. W przypadku próbników pasywnych pobieranie analitów następuje na drodze swobodnego transportu masy przez membranę do medium zatrzymującego, na skutek różnicy potencjałów chemicznych analitów w medium zatrzymującym w próbniku i środowiskiem wodnym, w którym umieszczany jest próbnik. Największą zaletą stosowania próbników...
-
Surrogate models and automated cad of passive microwave components
PublikacjaW pracy pokazane zostały techniki modelowania złożonych układów elektronicznych wysokiej częstotliwości. Modele zastępcze mają postać sparametryzowanych modeli matematycznych tworzonych za pomocą schematów interpolacyjnych lub skupionych, pasywnych układów zastępczych dedykowanych analizie w dziedzinie czasu. Do konstrukcji modeli wykorzystywane są wyniki symulacji elektromagnetycznych, co pozwala na osiągnięcie lepszej dokładności...
-
Bistatic passive radar simulator with spatial filtering subsystem
Publikacja -
Bearing errors passive sonar stationary target location
PublikacjaPrzedstawiono metodę wyznaczania współrzędnych nieruchomego celu na podstawie namiarów wykonywanych w sonarze pasywnym. Określono wymagania odnośnie ruchu sonaru, przy których błędy wyznaczania współrzędnych są minimalne. Podano zależności umożliwiające analityczne wyznaczanie błędów współrzędnych. Poprawność wyników analizy potwierdzono eksperymentami numerycznymi.
-
Zero-Pole Approach in Microwave Passive Circuit Design
PublikacjaIn this thesis, optimization strategies for design of microwave passive structures including filters, couplers, antenna and impedance transformer and construction of various surroogate models utilized to fasten the design proces have been discussed. Direct and hybrid optimization methodologies including space mapping and multilevel algorithms combined with various surrogate models at different levels of fidelity have been utilized...
-
Roll respose of ship fitted with passive stabilizing tank.
PublikacjaPrzedstawiono fizyczny i matematyczny model kołysań statku z biernym zbiornikiem stabilizacyjnym. Wyprowadzono równania ruchu i podano ich rozwiązania. Określono najistotniejsze zalecenia projektowe w oparciu o uzyskane rozwiązania. Wskazano kierunek poszukiwania optymalnych rozwiązań dla układu statek-bierny zbiornik stabilizacyjny.
-
Passive sampling and/or extraction techniquesin environmental analysis: a review
PublikacjaPrzedstawiono przegląd literaturowy dotyczący pasywnych technik izolacji i wzbogacania analitów z matryc środowiskowych, takich jak powietrze, woda czy gleba. Zwrócono uwagę na rosnącą rolę technik pasywnych w monitoringu środowiskowym oraz zaprezentowano krótki rys historyczny rozwoju tych technik.
-
The effect of tensile stresses on aluminium passive layer durability
PublikacjaW niniejszej pracy przedstawiono wyniki badań DEIS dotyczących wpływu naprężeń rozciągających na trwałość warstwy pasywnej aluminium A91050, prowadzonych w środowisku chlorków w temperaturze pokojowej.Zastosowana technika pozwoliła na wyznaczenie krytycznej wartości wydłużenia, przy której doszło do pęknięcia warstwy pasywnej na badanym stopie.
-
The passive operating mode of the linear optical gesture sensor
PublikacjaThe study evaluates the influence of natural light conditions on the effectiveness of the linear optical gesture sensor, working in the presence of ambient light only (passive mode). The orientations of the device in reference to the light source were modified in order to verify the sensitivity of the sensor. A criterion for the differentiation between two states - "possible gesture" and "no gesture" - was proposed. Additionally,...
-
Fragrant films on the basis of potato starch
Publikacja -
Fragrant starch-based films with limonene
Publikacja -
Temperature-dependent photoluminescence of polyazomethine films
Publikacja -
Electroabsorption in vacuum-evaporated films of bathocuproine
PublikacjaW pracy zmierzono widma elektroabsorpcji (EA) dla próżniowo naparowanych warstw batokuproiny (BCP), stosowanej jako transporter elektronów i bloker dziur w organicznych diodach elektroluminescencyjnych. Widma EA zinterpretowano na podstawie teorii efektu Starka przez bezpośrednie porównanie z widmami I-szej i II-giej pochodnej współczynnika absorpcji. Wyznaczono zmiany trwałego momentu dipolowego i zmiany polaryzowalności elektronowej...
-
Deposition and growth of thin ceramic films
Publikacja: Thin ceramic films play an important role in modern technology. One of the more utilized methods of deposition of ceramic films is spin coating. In this paper we investigate optimal deposition parameters for LaNi0.6Fe0.4O3−δ thin layers spin coated from a polymeric precursor. The quality of the obtained layers is checked using scanning electron microscopy. Additionally, we investigate the growth of grains in ceramic films annealed at...
-
Thermal Instability of Gold Thin Films
PublikacjaThe disintegration of a continuous metallic thin film leads to the formation of isolated islands, which can be used for the preparation of plasmonic structures. The transformation mechanism is driven by a thermally accelerated diffusion that leads to the minimalization of surface free energy in the system. In this paper, we report the results of our study on the disintegration of gold thin film and the formation of nanoislands...
-
Superconductivity of 80NbN-20SiO2 granular films
PublikacjaPraca przedstawia badania właściwości nadprzewodzących warstw 80%NbN-20%SiO2 (procent molowy) o różnej grubości otrzymanych metodą zol-żel. Przejście nadprzewodzące badanych warstw mierzone w polu magnetycznym jest szerokie, co wyjaśnione zostało termicznie aktywowanym płynięciem pola magnetycznego wnikającego do próbki. W wysokich polach zaobserwowano w badanych warstwach indukowane polem magnetycznym przejście nadprzewodnik -...
-
Chapter 4. Use of permeation passive samplers in air monitoring
PublikacjaTechnika dozymetrii pasywnej znalazła szerokie zastosowanie w monitoringu powietrza. Z uwagi na posiadane zalety stanowi ona alternatywne rozwiązanie w stosunku do aktywnych technik wykorzystywanych w monitorowaniu poziomu zanieczyszczeń powietrza.
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
Publikacja -
Influence of passive house technology on time and cost of construction investment
PublikacjaDue to the changes in the energy standards for housing in Poland there are many concerns. Is the standard required by the regulation achievable and if it is, then at what cost? There are many solutions to construct a building in line with the requirements of passive house technology. They are differentiated by price and time required for implementation. This study is based on the solution proposed by one of Polish companies, offering...
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
PublikacjaAlternating Voltage Inverters (Converters) supplied by low-voltage sources DC (ex. fuel cell, photovoltaic cell) are most frequently realized on the basis of the three fundamental topologies: a) PWM voltage inverter with boost-converter" system, b) PWM voltage inverter with transformed converter DC/DC in the ,,boost-converter" system, c) PWM current converter. However none of these solutions is claimed to be the best and dominant...
-
Acoustic signal processing in passive sonar system with towed array
PublikacjaW referacie opisano przetwarzanie sygnałów akustycznych w pasywnym systemie hydrolokacyjnym. W pojęciu ''przetwarzanie sygnałów akustycznych'' mieszczą się wszelkie operacje wykonywane na sygnałach analogowych tj. wzmacnianie, filtracja i próbkowanie, jak również operacje na sygnałach cyfrowych uzyskanych w procesie próbkowania. Do operacji cyfrowych wykonywanych w systemie zalicza się synchronizację, konwersję, sortowanie, wytwarzanie...
-
Measurement of benzene concentration in urban air using passive sampling
PublikacjaAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Cheap Cancellation of Strong Echoes for Digital Passive and Noise Radars
PublikacjaThe problem of cancellation of strong, potentially nonstationary,echoes in noise radars and passive radars utilizing digitaltransmissions is considered. The proposed solution is a multi-stage procedure.Initial clutter estimates, obtained using the least mean squares(LMS) algorithm, are refined using specially designed filters, "matched"to spectral densities of targets and clutter. When the postprocessing filtersare noncausal, the...
-
Permeation passive sampling as a tool for the evaluation of indoor air quality
PublikacjaOkreślono stężenie średnie ważone w czasie wybranych lotnych związków organicznych w powietrzu ośmiu pomieszczeniach mieszkalnych na terenie miasta Gdańska. Do pobierania próbek analitów z powietrza wewnętrznego zastosowano permeacyjny dozymetr pasywny typu pudełkowego oraz technikę dynamiczną (urządzenie przepływowe z rurką sorpcyjną). Porównano wyniki uzyskane w wyniku zastosowania w/w technik pobierania próbek analitów.