Filtry
wszystkich: 2811
-
Katalog
- Publikacje 2387 wyników po odfiltrowaniu
- Czasopisma 54 wyników po odfiltrowaniu
- Konferencje 1 wyników po odfiltrowaniu
- Osoby 106 wyników po odfiltrowaniu
- Wynalazki 3 wyników po odfiltrowaniu
- Projekty 18 wyników po odfiltrowaniu
- Laboratoria 1 wyników po odfiltrowaniu
- Zespoły Badawcze 4 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 104 wyników po odfiltrowaniu
- Wydarzenia 4 wyników po odfiltrowaniu
- Dane Badawcze 128 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: GEOTECHNICS MONITORING
-
Simultaneous opto-electrochemical monitoring of carbamazepine and its electro-oxidation by-products in wastewater
PublikacjaThe growing human impact on aquatic environments, due to the extensive use of pharmaceuticals and the release of persistent pollutants, makes it necessary to implement new widespread methods for the characterisation and quantification of such contaminants and relative degradation products. Carbamazepine, 5H-dibenzo[b,f]azepine-5-carboxamide, (CBZ) is a widely used anti-epileptic drug, characterised by its limited removal by conventional...
-
Comparison of Different Measurement Techniques as Methodology for Surveying and Monitoring Stainless Steel Chimneys
PublikacjaThe measurement of a chimney axis is an engineering geodesy task. These measurements allow to assess the technical condition of chimneys and are usually carried out for reinforced concrete chimneys. When measuring high chimneys, the main problem may be the need to go a long distance to take a measurement. The surface of the chimney can also be problematic because it can absorb so much light from the range finder that total station...
-
MONTE CARLO MODELING OF OPTICAL SENSOR FOR POST-OPERATIVE FREE FLAP MONITORING
PublikacjaAfter a preliminary study of the currently employed methods in vitality monitoring of the tissue flaps (TRAM, DIEP, SIEA), a usefulness of optical techniques is discussed. It seems that one of the most promising in monitoring tissue flaps blood flow is a near infrared spectrometry (NIRS). However, a special design of a measurement sensor has to be developed. First, basing on the literature study an optical “window” is characterized....
-
Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System
PublikacjaOverhead power transmission lines, their supporting towers, insulators and other elements create a highly distributed system that is vulnerable to damage. Typical damage scenarios cover cracking of foundation, breakage of insulators, loosening of rivets, as well as cracking and breakage of lines. Such scenarios may result from various factors: groundings, lightning strikes, floods, earthquakes, aeolian vibrations, conductors galloping,...
-
Synchronic digital stereophotography and photogrammetric analyses in monitoring the flow of liquids in open channels
PublikacjaThe authors present the results of their research into photogrammetric documents based on synchronic digital images. Examples presented in the paper indicate the value of synchronic stereophotography in registering phenomena connected with liquids. Combining synchronic stereophotography with photogrammetric methods has allowed the authors to develop an application useful for monitoring the flow of a liquid in an open channel.
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublikacjaAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization
PublikacjaThe number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its...
-
Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes
PublikacjaThe most common method of determination of cavitation erosion resistance as well as the magnitude of erosion-corrosion synergistic interaction is based on the weight loss measurements. Nondestructive characterization of installations elements is in most cases impossible to perform. Also, such a measurement does not include local types of failure or alteration of operating conditions. There is an urge to elaborate a method for monitoring...
-
REAL-TIME VOICE QUALITY MONITORING TOOL FOR VOIP OVER IPV6 NETWORKS
PublikacjaThe primary aim of this paper is to present a new application which is at this moment the only open source real-time VoIP quality monitoring tool that supports IPv6 networks. The application can keep VoIP system administrators provided at any time with up-to-date voice quality information. Multiple quality scores that are automatically obtained throughout each call reflect influence of variable packet losses and delays on voice...
-
In-service measurement of the small wind turbine test stand for structural health monitoring
PublikacjaThis paper presents the research activity performed on a Small Wind Turbine (SWT) test stand. Commercially available turbine was modified towards incorporation of the sensors system for condition monitoring. Installed sensors measure angular shaft position, torque applied from the wind loads, vibration accelerations and last but not least rotational speed. All gathered data are then transferred and processed in Test.Lab by means...
-
Reducing Monitoring Costs in Industrially Contaminated Rivers: Cluster and Regression Analysis Approach
PublikacjaMonitoring contamination in river water is an expensive procedure, particularly for developing countries where pollution is a significant problem. This study was conducted to provide a pollution monitoring strategy that reduces the cost of laboratory analysis. The new monitoring strategy was designed as a result of cluster and regression analysis on field data collected from an industrially influenced river. Pollution sources in...
-
The use of the static thermography in monitoring flap perfusion in breast reconstruction with TRAM flap
PublikacjaThis paper shows results of the static thermography for intraoperative and postoperative imaging of TRAM flap perfusion. The results were compared with the clinical examination of flap perfusion. The study was conducted on a group of 38 female patients who underwent breast reconstruction.
-
Assessment and Optimization of Air Monitoring Network for Smart Cities with Multicriteria Decision Analysis
PublikacjaEnvironmental monitoring networks need to be designed in efficient way, to minimize costs and maximize the information granted by their operation. Gathering data from monitoring stations is also the essence of Smart Cities. Agency of Regional Air Quality Monitoring in the Gdańsk Metropolitan Area (pol. ARMAAG) was assessed in terms of its efficiency to obtain variety of information. The results on one-month average concentrations...
-
Microseismic Monitoring of Hydraulic Fracturing - Data Interpretation Methodology With an Example from Pomerania
PublikacjaMicroseismic monitoring is a method for localizing fractures induced by hydraulic fracturing in search for shell gas. The data is collected from an array of geophones deployed on the surface or underground. Ground vibrations are recorded and analysed for fracture location, magnitude and breakage mechanism. For successful microseismic monitoring one need a velocity model of underlying formations. The model is further tuned with...
-
Monitoring and efficiency assessment of biofilter air deodorization using electronic nose prototype
PublikacjaBiofiltration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype for monitoring and efficiency assessment of air biofiltration. The study was conducted using model gas mixtures containing representatives of three groups of chemical compounds: n-hexane...
-
Badania nieniszczące i monitoring elementów konstrukcji budowlanych w warunkach laboratoryjnych
PublikacjaW artykule przedstawiono wyniki przykładowych badań diagnostycznych elementów konstrukcji inżynierskich w warunkach laboratoryjnych metodą propagacji fal mechanicznych. Testom poddano płytę stalową, zakładkowe połączenie klejone oraz czołowe połączenie śrubowe. Badania ukierunkowano na pozyskiwanie i rozpoznawanie wzorców uszkodzeń dla elementów i defektów o znanej geometrii oraz kontrolowanym sposobie zniszczenia. Przeprowadzone...
-
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
PublikacjaDynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
Long Distance Vital Signs Monitoring with Person Identification for Smart Home Solutions
PublikacjaAbstract— Imaging photoplethysmography has already been proved to be successful in short distance (below 1m). However, most of the real-life use cases of measuring vital signs require the system to work at longer distances, to be both more reliable and convenient for the user. The possible scenarios that system designers must have in mind include monitoring of the vital signs of residents in nursing homes, disabled people, who...
-
Complex Corrosion Monitoring System for Crude Distillation Unit in Form of Neutral Network
PublikacjaComplex and successful corrosion monitoring of refinery processes can significantly reduce material losses and failure risk. The developed corrosion monitoring system is based on online ultrasonic sensors, ER (electrical resistance) probes, gravimetric method and multipoint analytical analysis of chemical composition of the fluids. Additional online LPR (linear polarization resistance) sensors controlling corrosiveness of sour...
-
Presence of antibiotics in the aquatic environment in Europe and their analytical monitoring: Recent trends and perspectives
PublikacjaThe presence of antibiotics and their metabolites in the aquatic environment exerts a negative impact on all organisms. Moreover, the easy migration of these substances to drinking water may also have serious consequences for public health, such as drug resistance. Although antibiotics and their metabolites are detected in surface waters and wastewater, there are still no systemic solutions preventing environmental pollution with...
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublikacjaCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
A Diagnostic Method Based on Deflection Analysis for Monitoring Post-elastic Response of Beams
PublikacjaA non-destructive diagnostic method based on deflection analysis for monitoring the post-elastic response of beams was developed, and a diagnostic indicator was proposed. The indicator was defined as the second moment of the normalised curvature function about the mid-span, where the curvature was computed from the normalised deflection function. Elastic reference values of the indicator were computed for simply supported beams...
-
Method of Monitoring of the Grinding Process with Lapping Kinematics Using Audible Sound Analysis
PublikacjaUtilising microphones as audible sound sensors for monitoring a single-side grinding process with lapping kinematics is presented in the paper. The audible sound generated during grinding depended on the cutting properties of electroplated tools with D107 diamond grains and different thicknesses of the nickel bond. The tool wear affected the obtained technological effects such as material removal rate and the surface roughness...
-
Will NILM Technology Replace Multi-Meter Telemetry Systems for Monitoring Electricity Consumption?
PublikacjaThe estimation of electric power utilization, its baseload, and its heating, light, ventilation, and air-conditioning (HVAC) power component, which represents a very large portion of electricity usage in commercial facilities, are important for energy consumption controls and planning. Non-intrusive load monitoring (NILM) is the analytical method used to monitor the energy and disaggregate total electrical usage into appliance-related...
-
International Journal of Evidence Based Coaching & Mentoring
Czasopisma -
Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering
Czasopisma -
Wizyjny system monitoringu stanu nakładek ślizgowych odbieraków prądu
PublikacjaEksploatowane do niedawna w Polsce nakładki kolejowych odbieraków prądu były wykonywane w postaci styków miedzianych. Na początku 2011 r. przeprowadzono kompleksową zmianę typu nakładek stykowych z miedzianych na metalizowane węglowe.Wraz z wprowadzeniem nakładek węglowych istnieje potrzeba opracowania nowych metod diagnostyki tego istotnego elementu toru zasilania pojazdu. Celem diagnostyki jest wykrycie uszkodzonych i nadmiernie...
-
Centrum Doskonałości w zakresie Monitoringu i Analityki Środowiskowej
PublikacjaW artykule omówiono: cele i zadania Centrum Doskonałości Monitoringu i Analityki Środowiska (CEEAM); organizację pracy; pakiety robocze; podstawowe formy działalności edukacyjnej i naukowo-badawczej.
-
Zastosowanie technik chemometrycznych w analityce i monitoringu środowiskowym
PublikacjaW pracy przedstawiono wyniki monitoringu przybrzeżnej strefy Morza Bałtyckiego w rejonie Zatoki Gdańskiej. W projekcie oznaczano związki z grupy WWA, HC, OPNPS, OCP5, VOCl oraz wybrane metale ciężkie (Pb, Zn, Cd, Cu). Podjęto próbę wyjaśnienia występowania określonych grup zanieczyszczeń w próbkach wody morskiej poprzez charakteryzację źródeł zanieczyszczeń wód lądowych, a także dzięki wyjaśnieniu statystycznie istotnych korelacji...
-
Zintegrowany system monitoringu oddziaływań transportu kolejowego na środowisko
PublikacjaW artykule przedstawiono działania podejmowane w ramach realizacji projektu badawczego Wspólnego Przedsięwzięcia NCBR i PKP PLK pn. „Badania i Rozwój w Infrastrukturze Kolejowej – BRIK2”. Projekt dotyczy monitoringu szeregu parametrów opisujących oddziaływania transportu kolejowego na środowisko naturalne oraz tereny zurbanizowane. Założono, że na podstawie pomiarów określonych wielkości fizycznych oraz na podstawie szeregu danych...
-
Wizualizacja pomiarów z mobilnego systemu monitoringu zanieczyszczeń powietrza
PublikacjaArtykuł stanowi omówienie różnych możliwych podejść do wizualizacji pomiarów wykonywanych przez urządzenie zainstalowane na poruszającym się po mieście pojeździe. Jest on podsumowaniem nadzorowanych przez autora studenckich prac projektowych, których celem było rozpoznanie możliwości wizualizacyjnych współczesnych technologii dla potrzeb grantu badawczego pt. Mobilny system ekspertowy do badania i analizy zanieczyszczeń powietrza...
-
Wizyjny system monitoringu stanu nakładek stykowych odbieraków prądu
PublikacjaEksploatowane do niedawna w Polsce nakładki pantografów kolejowych były wykonywane w postaci styków miedzianych. Na początku 2011 r. przeprowadzono kompleksową zmianę typu nakładek stykowych, stosowanych przez operatorów korzystających z infrastruktury PKP PLK S.A., z miedzianych na metalizowane węglowe. Wraz z wprowadzeniem nakładek węglowych istnieje potrzeba opracowania nowych metod diagnostyki tego istotnego elementu toru zasilania...
-
Metody Śledzenia Obiektów W Rozproszonych Systemach Monitoringu Wideo
PublikacjaSystemy monitoringu wideo stały się powszechną częścią zarówno przestrzeni publicznej jak również miejsc o ograniczonym dostępie. Nadzór obszaru o dużej powierzchni wymaga rozmieszczenia wielu kamer. Skuteczna analiza przez człowieka dużej liczby obrazów wideo jest praktycznie niemożliwa. Dlatego rozwijane są metody służące do automatycznego przetwarzania wideo ukierunkowanego na analizę kontekstową. W przypadku niepokrywających...
-
DEDYKOWANY SYSTEM MONITORINGU WARUNKÓW KLIMATYCZNYCH W CENTRUM DANYCH
PublikacjaKoszty utrzymania centrum danych istotnie zależą od kosztów zużycia energii elektrycznej. Zapotrzebowanie na energię elektryczną w tego typu obiektach można optymalizować poprzez monitoring warunków klimatycznych oraz odpowiednie sterowanie czasem pracy urządzeń je utrzymujących. W pracy przedstawiono analizę czynników wpływających na zużycie energii elektrycznej w centrach danych oraz ich wpływ na koszty zużycia energii. Przedstawiono...
-
Czasowe wymagania bezpieczeństwa wobec systemu monitoringu ruchu drogowego
PublikacjaAnaliza drzew błędów jest dedukcyjną metodą analizy pozwalającą ustalić przyczyny wybranego zdarzenia niepożądanego. Posługuje się w tym celu koncepcją przyczyn bezpośrednich i logiki boolowskiej, a pozwala ustalić przyczyny podstawowe analizowanego zdarzenia. Technika ta wykorzystuje jednak w swoich modelach notację nieformalną, co może powodować niejednoznaczności i ograniczyć wartość analizy, szczególnie, jeśli pracuje nad nią...
-
Acta Geotechnica Slovenica
Czasopisma -
Perspectives on developing an automated monitoring system for the EBPR process - experiences from a pilot WWTP.
PublikacjaZaburzenia procesu biologicznego usuwania fosforu (BUF) są często spowodowane rozcieńczeniem ścieków w wyniku dopływu wód opadowych. Podobne efekty zaobserwowano w trakcie serii badań przeprowadzonych w pilotowej oczyszczalni ścieków Hanower-Gummerwald. Celem tych badań było określenie maksymalnej przepustowości hydraulicznej obiektu. Wyniki badań zostały wykorzystane do opracowania systemu automatycznego monitoringu procesu BUF...
-
Novel method of initiation stage of stress corrosion cracking monitoring with respect to marine constructions
PublikacjaKorozja konstrukcji morskich i jednostek pływających stanowi bardzo ważny problem w odniesieniu do aspektów bezpieczeństwa, gdyż w całym okresie eksploatacji narażone są na działanie bardzo agresywnego środowiska i innych czynników eksploatacyjnych. W rezultacie prowadzi to do niespodziewanych kolizji i wypadków. Praca przedstawia zastosowanie dynamicznej elektrochemicznej spektroskopii impedanycjnej (DEIS) do badania inicjacji...
-
Monitoring of essential and toxic elements in multi-ingredient food supplements produced in European Union
Publikacja -
Use of Bioluminescence for Monitoring Brown Coal Mine Waters from Deep and Surface Drainage
Publikacja -
Validation and modification of HPLC method for monitoring acetaminophen plasma concentrations in patients with chronic pancreatitis
PublikacjaBackground. Pancreatitis is the inflammation of the pancreas. The infl ammation may occur suddenly and resolve in a few days with the treatment in case of acute pancreatitis (AP). Chronic pancreatitis (CP) is a persistent inflammation of the pancreas that results in irreversible morphological changes and impairment of both exocrine and endocrine functions. Abdominal...
-
Investigation of Noise-Induced Instabilities in Quantitative BiologicalSpectroscopy and Its Implications for Noninvasive Glucose Monitoring
PublikacjaPrzedstawiono sposób oceny błędów jakie pojawiają się przy estymacji poziomu glukozy we krwi za pomocą pomiarów widm Ramana. Zastosowano nieliniowy algorytm regresji według maszyny wektorów nośnych. Określono jak na wyznaczenie stężenia glukozy we krwi wpływają błędy pomiarów widmach Ramana oraz błędów pomiaru referencyjnego stężenia glukozy podczas etapu kalibracji modelu (etapu uczenia algorytmu maszyny wektorów nośnych). Określono...
-
Networked Object Monitor - A distributed system for monitoring, diagnostics and control of complex industrial facilities
PublikacjaRozwój mobilności i technologii internetowych, a także globalizacji gospodarki światowej, uwzględniający kluczowe aspekty zarządzania przepływem informacji, otworzył zupełnie nowe możliwości opracowywania i konstruowania innowacyjnych rozwiązań technicznych. Z taką myślą powstał prototyp Sieciowego Monitora Obiektu, aplikacji umożliwiającej nie tylko ciągłą kontrolę parametrów obiektów przemysłowych i biznesowych, ale również zarządzanie...
-
Monitoring of deep foundation deflection in model experiments by means of a magnetic method: theoretical study.
PublikacjaZaproponowano oryginalną nieinwazyjną metodę pomiaru ugięcia pali bocznie obciążonych niespoistymi i małospoistymi gruntami suchymi lub wilgotnymi. Metoda ma zastosowanie do pomiaru ugięcia pali i ścian szczelnych oraz określania położenia innych fundamentów lub elementów zagłębionych w gruncie.
-
Development of a simple biogas analyzer module (BAM) for real-time biogas production monitoring
PublikacjaAnaerobic digestion (AD) relies on the cooperation of specific microbial communities, making it susceptible to process disruptions that could impact biogas production. In this regard, this study presents a technological solution based on the Arduino platform, in the form of a simple online monitoring system that can track the produced biogas profile, named as biogas analyzer module (BAM). The applicability of the BAM focused on...
-
Analysis of Modal Parameters Using a Statistical Approach for Condition Monitoring of the Wind Turbine Blade
PublikacjaThe primary objective of the presented paper is the numerical and experimental investigation related to developing a useful diagnostic method, which can be used for determining the site and size of damage in laminated shells of wind turbine blades. The described detection technique is based on the analysis of low frequencies bending vibrations mode shapes of rotor blades. The authors used the commonly applied statistics methods...
-
Monitoring the curing process of epoxy adhesive using ultrasound and Lamb wave dispersion curves
PublikacjaMonitoring the stiffness of adhesives is a crucial issue when considering the durability andstrength of adhesive joints. While there are many studies conducted on specimens madeonly from adhesive, the problem of curing of an adhesive film in real joints is moderatelyconsidered. This paper presents the monitoring of stiffening of epoxy adhesive using ultra-sound. Ultrasonic pulse velocity method was firstly applied for monitoring...
-
Monitoring działania wzmocnienia gruntu pod nasypem drogowym za pomocą sztywnych kolumn
PublikacjaOpis systemu pomiarowego zainstalowanego w kolumnach betonowych wzmacniających słabe podłoże gruntowe pod nasypem drogowym. Wstępne przedstawienie przykładowych wyników pomiarów. Problematyka niedokładności i odchyleń pomiarowych oraz sposób ich interpretacji.
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery
Publikacja -
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublikacjaThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...