Filters
total: 3148
filtered: 2066
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: MANUAL EXTENSOMETER MEASUREMENT
-
Measurement accuracy evaluation of transmission line earthings by impulse tests
PublicationUziemienia słupów linii energetycznych powinny być sprawdzane okresowo. Pomiary rezystancji takich uziemień przy pomocy metody niskoczęstotliwościowej wymaga wyłaczania linii i odkręcania przewodów odprowadzających od konstrukcji słupa. Metoda udarowa jest znacznie łatwiejsza w tej aplikacji i nie wymaga wyłaczania linii na czas pomiarów. W pracy oszacowano wpływ uziemień sąsiednich słupów na dokładność pomiarów metodą udarową.
-
Quality of Analytical Results: Classifiying Errors and Estimating Measurement Uncertainty
Publication -
<title>Measurement and control of field in RF GUN at FLASH</title>
Publication -
Reliability of Ultrasonic Distance Measurement in Application to Multi-Rotor MAVs
Publication -
On-line measurement of cell impedance during charging and discharging process
PublicationW pracy przedstawiono założenia metody pomiaru impedancji, która w przeciwieństwie do dotychczasowych technik impedancyjnych stosowanych w badaniach ogniw, umożliwia pracę on-line. W celu zaprezentowania możliwości metody wykonano eksperyment polegający na cyklicznym ładowaniu i rozładowywaniu elektrody ołowianej w 4.8M H2SO4 z jednoczesnym pomiarem impedancji. Zmiany parametrów elektrycznych otrzymanych w wyniku analizy widm impedancyjnych...
-
Continuous-time delay system identification insensitive to measurement faults
PublicationW pracy wykorzystuje się algorytmy identyfikacji do estymacji parametrów systemów ciągłych z opóźnieniem. Zastosowanie filtrów całkujących ze skończonym horyzontem obserwacji pozwala przekształcić równanie różniczkowe opisujące system ciągły do użytecznej postaci regresyjnej z czasem dyskretnym. Uzyskany w ten sposób i zachowujący oryginalną parametryzację model dyskretny daje się identyfikować stosując klasyczną metodę najmniejszych...
-
Cost‐effectiveness of blood pressure measurement and hypertension follow‐up
Publication -
A Method of Lathe Checks Measurement; SMOF device and its software
Publication -
The Goertzel filter-bank usage in the non-stationary impedance measurement.
PublicationArtykuł prezentuje metodę pomiaru parametrów impedancyjnych w warunkach niestacjonarnych bazującą na próbkowaniu sygnałów pomiarowych i przetwarzaniu cyfrowym. Zaproponowano i przeanalizowano zastosowanie banku filtrów Goertzela. Porównano zaproponowane podejście z tradycyjnie stosowaną metodą STDFT. Przedstawiono wynik symulacji i pomiarów.
-
Measurement of transverse force with polarization-maintaining side-hole fibers.
PublicationW pracy badano możliwości wykorzystania przenoszących stan polaryzacji światłowodów typu Side-Hole do pomiaru siły działającej prostopadle do osi symetrii światłowodu. Na podstawie wyników modelowania stwierdzono, ze niektóre światłowody tego typu charakteryzują się większą czułością aniżeli standardowe światłowody przenoszące stan polaryzacji. W wyniku przeprowadzonych pomiarów potwierdzono wyniki modelowania.
-
Portable computer measurement system of machine tools in wood industry
PublicationW pracy przedstawiono przenośny system diagnostyczny przeznaczony do oceny pracy obrabiarek skrawających i urządzeń przemysłu drzewnego. Ocena procesu obróbczego odbywa się na podstawie pomiaru wielkości mechanicznych, takich jak: prędkość obrotowa , przemieszczenia oraz przyspieszenia. Korzystanie z programów komputerowych, w które system jest wyposażony, pozwala użytkownikowi maszyn na przeprowadzanie szczegółowych analiz, dzięki...
-
Time-of-flight fiber optic sensors for strain and temperature measurement
PublicationW pracy przedstawiono światłowodowy sensor czasu przelotu do pomiaru odkształceń i temperatury mogący pracować zarówno w modzie transmisyjnym, jak i odbiciowym. W pomiarach czasu przelotu wykorzystano krótkie impulsy światłowodowe wprowadzane do jednodomowego światłowodu. Pod wpływem czynników zewnętrznych (temperatura, odkształcenie, siła rozciągająca) zmieniała się droga optyczna w światłowodzie, co powodowało zmiany czasu przelotu...
-
The influence of parameters of input probe on the error of high impedance measurement
PublicationW artykule przedstawiono sondę do pomiaru wysokich impedancji w zakresie 1kohm<|Zx|<100Gohm przeznaczoną do dołączenia do analizatorów typu gain-phase. Przeanalizowano wpływ parametrów sondy (pojemności pasożytnicze, toleranca rezystorów określających wzmocnienie wzmacniacza) na dokładność wyznaczenia modułu i argumentu zespolonego stosunku sygnałów wydzielonych w sondzie. Zamieszczono wyniki symulacji i pomiarów, pozwalające na...
-
Setups for measurement of thermal time constant of bolometers and resistive layers
PublicationPrzedstawiono dwa układy do pomiaru termicznej stałej czasowejbolometrów i warstw rezystywnych, umożliwiające pomiar wartości tego parametru w zakresie od pojedynczych milisekund do kilku sekund. Przedstawiono wyniki pomiarów termicznej stałej czasowej wybranych warstw rezystywnych wykonanych w technologii LTCC z niestechiometrycznych tlenków lantanowo-strontowo-żelazowych oraz bolometru cienkowarstwowego wykonanego w tej samej...
-
Drift, wow and flutter measurement and reduction in shrunken movie soundtracks
PublicationReferat przedstawia metodę i algorytmy do oceny i redukcji dryfu, kołysania i drżenia w skurczonych taśmach filmowych. Przedstawione algorytmy działają w oparciu o przetwarzaniu obrazu taśmy filmowej w celu wyznaczenia jej lokalnego skurczu, który jest jednym z powodów powstawania dryfu, kołysania i drżenia. Lokalny skurcz taśmy można wyznaczyć dzięki analizie wysokości: ramki obrazu, perforacji, lub innego, standaryzowanego elementu...
-
Theoretical and Measurement Investigations of DS CDMA Signal Detection Problem
PublicationPrzedstawiono opis teoretyczny wybranej motody wykrywania sygnałów z widmem rozproszonym DS CDMA. Przedstawiono prototypowe stanowisko laboratoryjne do wykrywania sygnałów DS CDMA i zaprezentowano wyniki pomiarowe.
-
Microsystem for measurement of impedance sensors parameters.Optoelectronic and electronic sensors V.
PublicationW artykule przedstawiono mikrosystem do pomiaru parametrów impedancyjnych czujników o module impedancji z przedziału 100ohm-1Gohm. Zastosowana w mikrosystemie technika cyfrowego przetwarzania sygnałów, pozwoliła na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich od 100uHz do 1MHz, przy zachowaniu prostej konstrukcji zapewniającej jego niską cenę. Mikrosystem zrealizowano w formie przyrządu...
-
Comparison of modelling and measurement results of spectra emitted by a programmable lamp
PublicationNowadays artificial light with an optimized spectrum is used in many different applications. For instance, it is widely used in museums and exhibitions to illuminate the art. Moreover, such light stimulates the growth of plants, or can be applied in industry and healthcare. To achieve the best results for each application, the adjusting of a dedicated spectrum is required, which is a complicated task. The ongoing research is focused...
-
Measurement of engine and vehicle parameters using onboard CAN network
PublicationWspółczesne samochody wyposażane są w dużą liczbę układów elektronicznych, które wymagają wzajemnej wymiany informacji. Techniczne problemy niezależnego łączenia ze sobą dużej liczby sterowników doprowadziły do powstania pokładowych sieci wymiany danych. Do najpopularniejszych z nich zalicza się obecnie system CAN. W pracy przedstawiono metodę rozpoznawania ramek wiadomości transmitowanych w pokładowej sieci CAN pojazdu przez sterowniki....
-
Measurement of benzene concentration in urban air using passive sampling
PublicationAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Device-independent quantum key distribution based on measurement inputs
PublicationWe provide an analysis of a family of device-independent quantum key distribution (QKD) protocols that has the following features. (a) The bits used for the secret key do not come from the results of the measurements on an entangled state but from the choices of settings. (b) Instead of a single security parameter (a violation of some Bell inequality) a set of them is used to estimate the level of trust in the secrecy of the key....
-
Measurement of Coherence Bandwidth in UHF Radio Channels for Narrowband Networks
PublicationThis paper presents results of investigation on the coherence bandwidth of narrowband radio channels in 430MHz band. The coherence bandwidth values were estimated froma power delay profile obtained by recording CDMA2000 forward channel signals during real-fieldmeasurements in various environments:mediumcity, flat terrain, and hilly terrain in northern Poland.The results of measurements are compared with characteristic parameters...
-
Quality of Analytical Results: Classifiying Errors and Estimating Measurement Uncertainty
PublicationThe most important parameter of each analytical result is its reliability. An analytical result is not a constant value; each result has two properties, error and uncertainty. The sources of both these parameters have to be known and their values determined (estimated). All analytical results are obtained by applying an appropriate measuring procedure. The need for reliable results requires application of reliable analytical procedures,...
-
MEASUREMENT O F HEALTHCARE SYSTEM EFFICIENCY IN OECD COUNTRIES
PublicationIncreased spending on healthcare systems in many countries tends to attract attention to their efficiency. The aim of this paper is to evaluate the efficiency of healthcare systems in the OECD countries and indicate causes of inefficiency by applying Data Envelopment Analysis (DEA) and using additive and super-efficiency models. The homogeneity of the sample is assessed and outliers are excluded. A ranking is established on the...
-
Remote measurement of building usable floor area - Algorithms fusion
PublicationRapid changes that are taking place in the urban environment have significant impact on urban growth. Most cities and urban regions all over the world compete to increase resident and visitor satisfaction. The growing requirements and rapidity of introducing new technologies to all aspects of residents' lives force cities and urban regions to implement "smart cities" concepts in their activities. Real estate is one of the principal...
-
Nondestructive Testing of the Miter Gates Using Various Measurement Methods
PublicationWhen any problems related to civil engineering structures appear, identifying the issue through the usage of only one measuring method is difficult. Therefore, comprehensive tests are required to identify the main source. The strains and displacement measurements, as well as modal identification, are widely used in the nondestructive testing of structures. However, measurements are usually carried out at several points and confirm...
-
Significant Decrease in Glycated Hemoglobin, 2h-Post-Load Glucose and High-Sensitivity C-Reactive Protein Levels in Patients with Abnormal Body Mass Index after Therapy with Manual Lymphatic Drainage
Publication -
Uncertainty Quantification of Additive Manufacturing Post-Fabrication Tuning of Resonator-Based Microwave Sensors
PublicationReconfigurability, especially in terms of the ability of adjusting the operating frequency, has become an important prerequisite in the design of modern microwave components and systems. It is also pertinent to microwave sensors developed for a variety of applications such as characterization of material properties of solids or liquids. This paper discusses uncertainty quantification of additive-manufacturing-based post-fabrication...
-
Comparison of the Measurement Techniques Employed for Evaluation of Ambient Air Odour Quality Influenced by Operation of Industrial Sewage Treatment Plant
PublicationThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of a sewage treatment plant of the LOTOS Group S.A. petroleum plant. The investigation was performed during winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type...
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublicationtIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
Discrete identification of continuous non-linear and non-stationary dynamical systems that is insensitive to noise correlation and measurement outliers
PublicationThe paper uses specific parameter estimation methods to identify the coefficients of continuous-time models represented by linear and non-linear ordinary differential equations. The necessary approximation of such systems in discrete time in the form of utility models is achieved by the use of properly tuned `integrating filters' of the FIR type. The resulting discrete-time descriptions retain the original continuous parameterization...
-
Shaping coherence function of sources used in low-coherent measurement techniques
PublicationW niskokoherencyjnych technikach pomiarowych kształt funkcji koherencji wykorzystywanego źródła ma bezpośredni wpływ na parametry metrologiczne układu pomiarowego. Z tego względu, w wielu aplikacjach niezbędne jest użycie metod pozwalających na zmianę kształtu tej funkcji. W artykule przeanalizowano możliwości kształtowania funkcji koherencji, a przedstawione analizy teoretyczne i wyniki symulacji komputerowych wskazują, że kształtowanie...
-
Measurement of rare probes with the silicon tracking system of the CBM experiment at FAIR
Publication -
Installation of GNSS receivers on a mobile railway platform – methodology and measurement aspects
Publication -
Selection of measurement frequency in Mott–Schottky analysis of passive layer on nickel
Publication -
3D MONITORING � IDENTIFICATION OF MEASUREMENT PROBLEMS AT LARGER MOVEMENTS OF THE TRACKED POINTS
Publication -
Study of swimbladder morphometry of Baltic herring and sprat (development of measurement methodology)
PublicationEffective management of Baltic clupeids, which are valuable commercially and ecologically,requires the biomass control. The acoustical techniques are recognized as effective in fishstock assessment. The study of Baltic herring and sprat individual backscatteringcharacteristics is required for the accurate biomass estimation using acoustical techniques.The previous measurements demonstrated significant...
-
Shaping coherence function of sources used in low-coherent measurement techniques
Publication -
P-674 Automatizing ovarian follicle counting and measurement with artificial intelligence
Publication -
The influence of sampling parameters on accuracy of capacitance measurement in the method based on DSP.
PublicationW artykule przedstawiono metodę pomiaru parametrów impedancyjnych bazującą na próbkowaniu sygnałów pomiarowych i DSP. Przeanalizowano wpływ głównych źródeł niepewności i błędów na dokładność pomiaru pojemności. Zawarto analizę dla następujących parametrów: niesynchroniczne próbkowanie sygnałów pomiarowych (napięciowego i prądowego), rozdzielczość przetwornika a/c i ilość zbieranych próbek. Załączono wyniki symulacji.
-
Measurement of noise parameter set in the low frequency range: requirements and instrumentation.
PublicationOpisano dwa podstawowe szumowe modele metrologiczne czwórnika: ze źródłami szumów odniesionymi do wejścia i ze zwarciowymi prądami szumów. Parametry szumowe opisujące modele zawierające korelację pomiędzy prądami i/lub napięciami są mierzone przy zastosowaniu metod bezpośrednich i pośrednich. Przedstawiono kilka technik redukcji szumów własnych systemu pomiarowego. Szerzej zaprezentowano dwukanałowy system do pomiaru szumów z komputerowym...
-
Impedance spectroscopy by means of a digital storage oscilloscope based measurement system.
PublicationW pracy przedstawiono system pomiarowy służący do badań spektroskopowych. Został on zbudowany w oparciu o szerokopasmowy oscyloskop cyfrowy. Przeprowadzono analizę dokładności pomiarów oraz przedstawiono wyniki badań kalibracyjnych i przykładowych pomiarów parametrów materiałów biologicznych.
-
Flow field around growing and rising vapour bubble by PIV measurement.
PublicationPrzedstawiono wyniki badania pól prędkości wokół wzrastających i unoszących się pęcherzyków parowych generowanych z pojedynczego centrum nukleacji. W badaniach zastosowano komercyjny układ Particle Image Velocimetry.
-
Design and measurement of gyrator and isolator using ferrite coupled microstrip lines
PublicationW publikacji przeprowadzono badania struktur żyratora i izolatora zrealizowanych w technice sprzężonych ferrytowych linii mikropaskowych. Po raz pierwszy zaprezentowano wyniki pomiaru zrealizowanych struktur tego rodzaju. Uzyskane wyniki potwierdzają przewidziany uprzednio efekt zmian kierunków działania opisywanych elementów ze zmianą częstotliwości.
-
Portable computer diagnostics system PSD - the measurement potentiality and application examples
PublicationOpisano system diagnostyczny do pomiarów statycznych i dynamicznych wszelkiego typu maszyn stosowanych w przemyśle drzewnym. ocena stanu maszyny może byc dokonywana na podstawie wyników pomiaru bicia osiowego i promieniowego wrzecion, pił tarczowych, przemieszczeń poprzecznych piły tasmowej itp.. System jest wyposażony w specjalne oprogramowanie i pozwala m. in. na przeprowadzanie szczegółowych analiz tj. wykonywanie FFT lub filtrowanie...
-
Shaping of coherence function of sources used in low-coherent measurement techniques
PublicationW artykule przedstawiono zależność pomiędzy charakterystyką widmową źródła i ekwiwalentną długością drogi koherencji źródła. Wyniki analizy teoretycznej i symulacji komputerowych wykazały, że użycie źródła syntezowanego wpływa na zmniejszenie wartości ekwiwalentnej długości drogi koherencji. Dodatkowo wykazano, że zmniejszenie ekwiwalentnej długości drogi koherencji można otrzymać poprzez odpowiednie kształtowanie funkcji koherencji...
-
Application of acoustic emission metod for measurement of joint gap and cartilage surfaces
PublicationW artykule przedstawiono zastosowanie emisji akustycznej do lokalizacji wczesnych uszkodzeń stawu biodrowego lub kolanowego człowieka. Ponadto metoda ta służy do pomiaru wysokości szczeliny stawu oraz struktury geometrycznej powierzchni chrząstki stawowej. Jest to metoda nieinwazyjna. Pomiary metodą emisji akustycznej stosujemy na ogół w materiałach, w których energia sprężysta zmienia się nagle. Takie zmiany energii mogą być...
-
Chapter 6 : Non-intrusive measurement techniques in bubble dynamics investigation
PublicationPrzedstawiono wyniki badań dynamiki pęcherzyków parowych i gazowych przy użyciu nieinwazyjnych metod optycznych i akustycznych.
-
Analysis of the Usefulness of Cheap Audio Recorders for Spectral Measurement of Environmental Noise
PublicationEnvironmental noise pollution is nowadays one of the most serious health threats. The impact of noise on the human body depends not only on the sound level but also on its spectral distribution. Reliable measurements of the environmental noise spectrum are often hampered by the very high price of top quality measuring devices. This paper explores the possibility of using much cheaper audio recorders for the frequency analysis....
-
Selection of measurement frequency in Mott-Schottky analysis of passive layer on nickel
PublicationPrzedstawiono zależności Mott'a - Schottky'ego dla różnych częstotliwości pomiarowych. Kształt uzyskanych zależności zależy od doboru tych częstotliwości. Związane jest to z tym, że stężenie defektów w warstwie pasywnej zależy od doboru częstotliwości. Metoda DEIS pozwala na uniknięcie tych niedogodności.