Filters
total: 1318
-
Catalog
displaying 1000 best results Help
Search results for: CAMERA ARRAY CALIBRATION
-
Automatic detection of abandoned luggage employing a dual camera system
PublicationA system for automatic detection of events using a system of fixed and PTZ (pan-tilt-zoom) cameras is described. Images from the fixed camera are analyzed by means of object detection and tracking. Event detection system uses a set of rules to analyze data on the tracked moving objects and to detect defined events. A PTZ camera is used to obtain a detailed view of a selected object. A procedure for conversion between the pixel...
-
Structural optimization of microjet array cooling system
PublicationThe single phase heat transfer from an upward facing, horizontal copper surface to arrays of impinging water jets was experimentally investigated. Experimental configuration allows for a free-surface unconfined jets flow. Square nozzles 50 × 100 μm arranged in four different geometries were used. Additionally, for the set of two jets array geometry was varied by adjusting the nozzle to nozzle distance. The area averaged heat transfer...
-
Compact antenna array comprising fractal-shaped microstripradiators
PublicationA design method of antenna array consisting of eight microstrip patches modified with Sierpinski fractal curves has been presented andexperimentally validated in this paper. Method proposed has enabled the achievement of considerable miniaturization of array length (26%),together with multi-band behavior of the antenna, which proves the attractiveness of presented design methodology and its ability to be implemented in more complex...
-
DESIGN AND CALIBRATION OF ROLLING RESISTANCE TEST TRAILER R2mk.2
PublicationThe paper describes construction nad calibration procedures of the rolling resistance test trailer R2 Mk2. The trailer is design to measure rolling resistance of passenger car tyres in various road conditions on trafficked road. The trailer utilizes so called angle method also known as vertical arm method. The paper presents also calibration procedures that are necessary to ascertain good precision of the measurements.
-
Mobile Laser Scanning Calibration on a Marine Platform
PublicationThe article describes the method of calibration of the Riegl VMZ-400 mobile scanning system on a floating platform and an experiment aimed at conducting measurements from a previously calibrated instrument. The issue of factors affecting the quality of measurements was discussed. Mobile laser scanning is an increasingly popular measurement solution, but it is still innovative on a European scale. The use of a floating platform...
-
Calibration images under different lighting conditions vol. 1
Open Research DataDataset description: Calibration images under different lighting conditions vol. 1
-
A Conformal Circularly Polarized Series-Fed Microstrip Antenna Array Design
PublicationA conformal circularly polarized series-fed microstrip array design for broadside radiation is presented. The array aperture under design is conformal to a cylindrical surface of a given radius. The approach we present primarily addresses focusing of the circularly polarized major lobe of the conformal array by proper dimensioning of the aperture spacings. The proposed analytical models yield the values of the element spacings...
-
Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation
PublicationA procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...
-
Optical method for verification of homogeneity of phantoms for calibration of magnetic resonance
PublicationThe primary purpose of this study was to develop a laboratory photonic set-up for characterisation of homogeneity of gel phantoms for calibration of magnetic resonance. In this system, optical coherence tomography allows the detection of micro- and macroscopic heterogeneities of a structure. The set-up was used to perform measurements of agar and agar-carrageenan gels, which are the basis for more complex phantoms for magnetic...
-
Millimeter Wave Negative Refractive Index Metamaterial Antenna Array
PublicationIn this paper, a novel negative refractive index metamaterial (NIM) is developed and characterized. The proposed metamaterial exhibits negative effective permittivity (εeffe) and negative effective permeability (µeffe) at millimeter wave frequency of 28GHz. This attractive feature is utilized to enhance the gain of a microstrip patch antenna (MPA). Two thin layers of 5 5 subwavelength unit cell array of NIM are placed above a...
-
Testing of Technical Fabrics under Fast Camera Control
PublicationThe dynamic development of measurement and recording techniques has been changing the way one conceives material strength. In this study, two different methods of evaluating the strength of fabrics are compared. The first is the typical and commonly used technique based on the use of a testing machine. The second method uses the so-called “fast camera” to monitor the entire process of the destruction of a fabric sample and analyse...
-
Estimation of DC motor parameters using a simple CMOS camera
PublicationDifferent components of control systems for mobile robots are based on dynamic models. In low-cost solutions such a robot is wheeled and equipped with DC motors, which have to be included in the model of the robot. The model is fairly simple but determination of its parameters needs not to be easy. For instance, DC motor parameters are typically identified indirectly using suitable measurements, concerning engine voltage, current,...
-
Objects classification based on their physical sizes for detection of events in camera images
PublicationIn the paper, a method of estimation of the physical sizes of the objects tracked in the video surveillance system, and a simple module for object classification based on the estimated physical sizes, are presented. The results of object classification are then used for automatic detection of various types of events in the camera image.
-
The Linear Array 2x1 of Slot Monopoles for 6-8.5 GHZ UWB Standard
PublicationThe results of numerical simulations and measurements of 2x1 linear array of slot monopoles are presented in the paper. At the begining a single slot monopole was designed. Next the 2x1 linear array of these monopoles was numerically tested for various configurations of the feeding network. The single monopole and the array were fabricated and the results of the measurements of the reflection coefficients and the radiationpatterns...
-
Evaluation of respiration rate and pattern using a portable thermal camera
PublicationThe goal of this paper was to analyze the accuracy of the proposed method for the evaluation of respiration rate and respiration rhythm patterns (e.g. inspiration slope) using the portable and mobile thermal camera module that could be a part of smart glasses. Parameters were analyzed for 12 volunteers in two experiments, when subjects speak and do not speak. The pressure, chest belt was used as a reference measurement method....
-
Calibration images under different lighting conditions vol. 2
Open Research DataDataset description: Calibration images under different lighting conditions vol. 1
-
Optimal configuration of an electrode array for measuring ventricles' contraction
PublicationAn influence of an electrode-array configuration on an impedance signal composition for a fixed spatial distribution of its sources is examined in the paper. The Finite Element Method and Geselowitz relationship were used for examining three different electrode-arrays. A sensitivity approach was used to evaluate each configuration assuming that localization of the signal source is known. A conductivity change, thus the source of...
-
Mechanical characterization of a gravel column in a calibration chamber operating as a triaxial cell
PublicationA series of tests considering the behavior of gravel columns was performed. A segment of column with a height of 1 m and a diameter of 0.53 m was modelled in a calibration chamber used as a triaxial cell at three different lateral stress applied. The vertical load transferred on the column head was simulated with steady increase of water pressures in the upper and lower membranes. During the loading the volumetric changes in the...
-
The Influence of Camera and Optical System Parameters on the Uncertainty of Object Location Measurement in Vision Systems
PublicationThe article presents the influence of the camera and its optical system on the uncertainty of object position measurement in vision systems. The aim of the article is to present the methodology for estimating the combined standard uncertainty of measuring the object position with a vision camera treated as a measuring device. The identification of factors affecting the location measurement uncertainty and the determination of their...
-
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...
-
Frequency Selective Surface Based MIMO Antenna Array for 5G Millimeter-Wave Applications
PublicationAbstract: In this paper a radiating element consisting of a modified circular patch is proposed for MIMO arrays for 5G millimeter-wave applications. The radiating elements in the proposed 2×2 MIMO antenna array are orthogonally configured relative to each other to mitigate mutual coupling that would otherwise degrade the performance of the MIMO system. The MIMO array was fabri-cated on Rogers RT/Duroid high frequency substrate...
-
ECU calibration for gaseous dual fuel supply system in compression ignition engines
PublicationThe dual fuel (DF) combustion mode is proven solution that allows to improve or get at the same level engine performance and reduce toxic compounds in exhaust gases which is confirmed by researchers and end-users. DF combustion mode uses two fuels gaseous fuel as a primary energy source and a pilot quantity of diesel fuel as ignition source. However, in order, to fully take advantage of the potential of the dual fuel mode, DF system...
-
Azimuth estimator for a rotating array radar with wide beam
PublicationThe problem of estimating azimuth in rotating array radar with a beam, wide in the azimuth plane, is considered. Under such setup the echo signal usually has a very low signal to noise ratio, but the number of observations is large, because of long dwell times. The proposed solution is based on the maximum likelihood approach, but it employs simplifications which facilitate its implementation in real time systems. Results, obtained...
-
Calibration images under different lighting conditions - static for feature localisation
Open Research DataDataset description: Calibration images under different lighting conditions - static mode for feature detection
-
Face Profile View Retrieval Using Time of Flight Camera Image Analysis
PublicationMethod for profile view retrieving of the human face is presented. The depth data from the 3D camera is taken as an input. The preprocessing is, besides of standard filtration, extended by the process of filling of the holes which are present in depth data. The keypoints, defined as the nose tip and the chin are detected in user’s face and tracked. The Kalman filtering is applied to smooth the coordinates of those points which...
-
Multi-Camera Vehicle Tracking Using Local Image Features and Neural Networks
PublicationA method for tracking moving objects crossing fields of view of multiple cameras is presented. The algorithm utilizes Artificial Neural Networks (ANNs). Each ANN is trained to recognize images of one moving object acquired by a single camera. Local image features calculated in the vicinity of automatically detected interest points are used as object image parameters. Next, ANNs are employed to identify the same objects captured...
-
Camera Austria International
Journals -
Calibration in Metrological Approach
Publication -
Calibration and metrological approach.
PublicationPrzedstawiono teraźniejsze podejście do procesu kalibracji. Różnorodność definicji dotyczących pomiarów w chemii analitycznej, nierzadko niekonsekwentnych, może wprowadzić w zakłopotanie. W pracy wyjaśniono pojęcia takie jak: kalibracja, substancje wykorzystywane do kalibracji, walidacja, niepewność materiałów odniesienia. Omówiono również pojęcie spójności pomiarowej w odniesieniu do procesu kalibracji.
-
Using Disparity Map for Moving Object Position Estimation in Pan Tilt Camera Images
PublicationIn this paper we present the algorithm for rapid moving object position estimation in an images acquired from pan tilt camera. Detection of a moving object in a image acquired from a moving camera might be quite challenging. Standard methods that relay on analyzing two consecutive frames are not applicable due to the changing background. To overtake this problem we decided to evaluate the possibility of calculating a disparity...
-
Improving the accuracy of bearing in active sonar with cylindrical array using spectrum estimation.
PublicationThe articles presents a method for improving the accuracy of bearing in multibeam sonar with a cylindrical array. Based on a known spatial spectrum estimation technique, the method has been successfully used in linear array systems. Its accuracy of bearing is satisfactory and ensures a relatively low computational effort. The article discusses certain simplifications and assumptions to adapt the spatial spectrum estimation technique...
-
Methane (CH4) calibration set of FTIR spectra
Open Research DataThe calibration spectra for CH4 concentration calibration were supplied with this dataset
-
Estimation of respiration rate using an accelerometer and thermal camera in eGlasses
PublicationRespiration rate is a very important vital sign. Different methods of respiration rate measurement or estimation have been developed. However, especially interesting are those that enable remote and unobtrusive monitoring. In this study, we investigated the use of smart glasses for the estimation of respiration rate especially useful for indoors applications. Two methods were analyzed. The first one is based on measurements of...
-
ARRAY OF MINIJETS – THERMAL AND HYDRAULIC PHENOMENA IN BOUNDARY LAYER
PublicationPresented work considers flow and thermal phenomena occurring in the system consisting of minijets array and heated with constant heat flux surface. Numerical analyses, based on the mass, momentum and energy conservation laws, were conducted. Focus was placed on the proper model construction, in which turbulence and boundary layer modelling was crucial. Calculations were done for various mass flow rates. The main calculations were...
-
Rapid design closure of linear microstrip antenna array apertures using response features
PublicationA simple yet reliable approach to a rapid design closure of linear antenna array apertures at the electromagnetic (EM)-simulation level is proposed. Our methodology exploits an underlying array factor (AF) model suitably corrected by means of characteristic points (angles and levels) of the radiation pattern of the EM model of the antenna array aperture. This conveniently allows for controlling both the side lobe levels...
-
THE SYNCHROSQUEEZING METHOD IN BEARING ESTIMATION OF STATIONARY SIGNALS FOR PASSIVE SONAR WITH TOWED ARRAY
PublicationIn this paper, a novel method of bearing estimation in a passive sonar system with a towed array is introduced. The classical approach of bearing estimation based on the spatial spectrum [1] is extended by using the synchrosqeezing method that is a part of the reassignment method introduced by Kodera et al. [2]. Using this method leads to a precise bearing estimation. The proposed method requires a relatively small amount of computation,...
-
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublicationThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
ATTEMPTS OF THERMAL IMAGING CAMERA USAGE IN ESTIMATIONS OF THE CONVECTIVE HEAT LOSS FROM A VERTICAL PLATE
PublicationIn this paper a new method for determining heat transfer coefficients using a gradient method has been developed. To verify accuracy of the proposed method vertical isothermal heating plate with natural convection mechanism has been examined. This configuration was deliberately chosen, because of the fact that such case is historically the earliest and most thoroughly studied and its rich scientific documentation - the most reliable....
-
Layered background modeling for automatic detection of unattended objects in camera images
PublicationAn algorithm for automatic detection of unattended objects in video camera images is presented. First, background subtraction is performed, using an approach based on the codebook method. Results of the detection are then processed by assigning the background pixels to time slots, based on the codeword age. Using this data, moving objects detected during a chosen period may be extracted from the background model. The proposed approach...
-
Use of optical skin phantoms for calibration of dermatological lasers
PublicationA wide range of dermatological diseases can be efficiently treated using laser heating. Nevertheless, before the new laser is introduced into clinical practice, its parameters and ability to interact with human skin have to be carefully examined. In order to do that optical skin phantoms can be used. Such phantoms closely imitate the scattering and absorption properties of real human skin tissue along with its thermal properties,...
-
Identification of Emotional States Using Phantom Miro M310 Camera
PublicationThe purpose of this paper is to present the possibilities associated with the use of remote sensing methods in identifying human emotional states, and to present the results of the research conducted by the authors in this field. The studies presented involved the use of advanced image analysis to identify areas on the human face that change their activity along with emotional expression. Most of the research carried out in laboratories...
-
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
Carbon dioxide (CO2) calibration set of FTIR spectra
Open Research DataThe calibration spectra for CO2 concentration calibration were supplied with this dataset
-
Detection and Direction-of-Arrival Estimation of Weak Spread Spectrum Signals Received with Antenna Array
PublicationThis paper presents a method for the joint detection and direction of arrival (DOA) estimation of low probability of detection (LPD) signals. The proposed approach is based on using the antenna array to receive spread-spectrum signals hidden below the noise floor. Array processing exploits the spatial correlation between phase-delayed copies of the signal and allows us to evaluate the parameter used to make the decision about the...
-
Electrodes array for contactless ECG measurement of a bathing person - a sensitivity analysis
PublicationAn applicability of a remote (contactless) electrocardiogram (ECG) measurements in a bathtub is presented in the paper. Possibility of ECG measurements in shallowly filled tube with a water was examined. A bathing person was, both, sitting and lying during experiments performed. The problem became non-trivial when the bathing person was moving in reference to a fixed set of electrodes and located at the longer walls of the bathtub....
-
Fuzzy rule-based dynamic gesture recognition employing camera & multimedia projector
PublicationIn the paper the system based on camera and multimedia projector enabling a user to control computer applications by dynamic hand gestures is presented. The main objective is to present the gesture recognition methodology which bases on representing hand movement trajectory by motion vectors analyzed using fuzzy rule-based inference. The approach was engineered in the system developed with J2SE and C++ / OpenCV technology. OpenCV...
-
Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors
PublicationMonitoring air pollution is a critical step towards improving public health, particularly when it comes to identifying the primary air pollutants that can have an impact on human health. Among these pollutants, particulate matter (PM) with a diameter of up to 2.5 μ m (or PM2.5) is of particular concern, making it important to continuously and accurately monitor pollution related to PM. The emergence of mobile low-cost PM sensors...
-
Selection of Visual Descriptors for the Purpose of Multi-camera Object Re-identification
PublicationA comparative analysis of various visual descriptors is presented in this chapter. The descriptors utilize many aspects of image data: colour, texture, gradient, and statistical moments. The descriptor list is supplemented with local features calculated in close vicinity of key points found automatically in the image. The goal of the analysis is to find descriptors that are best suited for particular task, i.e. re-identification...
-
A Dual-Polarized 39 GHz 4x4 Microstrip Antenna Array for 5G MU-MIMO Airflight Cabin Connectivity
PublicationThis paper presents the design, fabrication, and experimental validation of a 39 GHz dual-polarized 4x4 microstrip antenna array. The array consists of 16 slot coupled circular microstrip patches, fed through SMPS connectors. The procedure requiring a reduced number of cables for measurement of the uniformly excited antenna array is also presented. The array exhibits 18 dBi peak gain and 2.9 GHz reflection bandwidth and is intended...
-
Verification of ESPAR Antennas Performance in the Simple and Calibration Free Localization System
PublicationThis paper presents the results of simulations and measurements of an indoor localization system that uses Electronically Steerable Parasitic Array Radiator (ESPAR) antennas with switched directional beam. Proposed antennas are dedicated for 2.4GHz ISM low-cost applications where determination of the incoming signal is required. The antennas performance is analyzed and verified with relation to positioning methods based on the...