displaying 1000 best results Help
Search results for: BISMUTH FILM ELECTRODE
-
Efficient removal of 2,4,6-trinitrotoluene (TNT) from industrial/military wastewater using anodic oxidation on boron-doped diamond electrodes
PublicationWith growing public concern about water quality particular focus should be placed on organic micropollutants, which are harmful to the environment and people. Hence, the objective of this research is to enhance the security and resilience of water resources by developing an efficient system for reclaiming industrial/military wastewater and protecting recipients from the toxic and cancerogenic explosive compound – 2,4,6-trinitrotoluene...
-
Scaling Up the Process of Titanium Dioxide Nanotube Synthesis and Its Effect on Photoelectrochemical Properties
PublicationIn this work, for the first time, the influence of scaling up the process of titanium dioxide nanotube (TiO2NT) synthesis on the photoelectrochemical properties of TiO2 nanotubes is presented. Titanium dioxide nanotubes were obtained on substrates of various sizes: 2 × 2, 4 × 4, 5 × 5, 6 × 6, and 8 × 8 cm2. The electrode material was characterized using scanning electron microscopy as well as Raman and UV–vis spectroscopy in order...
-
Processing of Ce0.8Gd0.2O2-δ barrier layers for solid oxide cells: The effect of preparation method and thickness on the interdiffusion and electrochemical performance
PublicationCe0.8Gd0.2O1.9 (CGO) barrier layers are required to mitigate the chemical reactions between Sr-containing oxygen electrode materials and Zr-based oxygen ion conductors in high-temperature solid oxide cells. Barrier layers produced by different methods were studied in this work. As a reference, a cell with no barrier layer was measured. The application of the powder-processed barrier layers, considerably increases the performance....
-
Electrocatalytic oxidation of methanol, ethylene glycol and glycerine in alkaline media on TiO2 nanotubes decorated with AuCu nanoparticles for an application in fuel cells
PublicationIn this work, we present the catalytic and photocatalytic activity of AuCu nanostructures obtained on TiO2 nanotubes toward methanol, ethylene glycol and glycerine oxidation. The electrode material is prepared by anodization of Ti foil, thin AuCu layer sputtering and rapid thermal treatment under argon atmosphere. Scanning electron microscopy images confirmed the presence of ordered tubular architecture of TiO2 as well as nanoparticles...
-
Graphene-based Silicone rubber Nanocomposites: Preparation, Characterization, and Properties
PublicationThis study aims to understand better the mechanical, thermal, and tribological behavior of silicone rubber nanocomposites. Graphite, exfoliated graphite, reduced graphene oxide, ionic liquid modified graphene oxide, silane-modified graphene oxide, fumed silica, and other fillers were used in this study. Adding graphene-based fillers to the silicone rubber matrix substantially improves the nanocomposite's mechanical, thermal, and...
-
Properties of ordered titanium templates covered with Au thin films for SERS applications
PublicationtCurrently, roughened metal nanostructures are widely studied as highly sensitive Raman scattering sub-strates that show application potential in biochemistry, food safety or medical diagnostic. In this workthe structural properties and the enhancement effect due to surface enhanced Raman scattering (SERS) ofhighly ordered nano-patterned titanium templates covered with thin (5–20 nm) gold films are reported.The templates are formed...
-
AFM-assisted investigation of conformal coatings in electronics
PublicationPurpose – This paper aims to presents a new method of investigation of local properties of conformal coatings utilized in microelectronics. Design/methodology/approach – It is based on atomic force microscopy (AFM) technique supplemented with the ability of local electrical measurements, which apart from topography acquisition allows recording of local impedance spectra, impedance imaging and dc current mapping. Potentialities...
-
Alternative Methods of Preparation of Soluble Keratin from Chicken Feathers
PublicationHuge amount of keratinous waste, especially birds’ feathers, demands more value-added application instead of dumping. The present work reports the results of experiments aimed at preparing soluble keratin useful for novel bioproduct formation. The effect of thermo-chemical treatments with various reducing agents, i.e. 2-mercaptoethanol, dithiothreitol, sodium m-bisulphite, and sodium bisulphite, as well as sodium hydroxide, on...
-
Recovery of silver metallization from damaged silicon cells
PublicationMetallization is one of the key process steps to fabricate solar cells with high performance in a cost-effective way. Majority of photovoltaic solar cell manufacturing uses thick film screen print metallization with Ag containing paste to produce solar cells. The average lifetime of PV modules can be expected to be more than 25 years. The disposal of PV systems will become a problem in view of the continually increasing production...
-
Damage Imaging in Lamb Wave-Based Inspection of Adhesive Joints
PublicationAdhesive bonding has become increasingly important in many industries. Non-destructive inspection of adhesive joints is essential for the condition assessment and maintenance of a structure containing such joints. The aim of this paper was the experimental investigation of the damage identification of a single lap adhesive joint of metal plate-like structures. Nine joints with different defects in the form of partial debonding...
-
Centrally Pivoted Tilting Pad Thrust Bearing with Carbon-Based Coated Collar—Experimental Results of Low- and Medium-Speed Operation
PublicationExperimental results of the research on a tilting pad thrust bearing with symmetrical pad support in the conditions of high loads and low speeds are presented in the paper. As described in the literature review, experimental results of tilting pad bearings at low speed/high load regime and transient conditions are rare. Unusual material selection - steel pad against a DLC-type coating on the collar was utilized. Such material combination...
-
Comparison of heat transfer characteristics in surface cooling with boiling microjets of water, ethanol and HFE7100
PublicationThe basis of microjet technology is to produce jets which impinge the surface at the stagnation point with a very high kinetic energy. Main objective of this paper was to investigate the physical phenomena occurring on solid surfaces upon impingement of the single microjet in case of three fluids, namely water, ethanol and HFE7100. Intense heat transfer in the impact zone of microjet has been examined and described with precise...
-
Analytical model with non-adiabatic effects for pressure drop and heat transfer during boiling and condensation flows in conventional channels and minichannels
PublicationIn the paper a method developed earlier by authors is applied to calculations of pressure drop and heat transfer coefficient for boiling flow and condensation flow with account of non- adiabatic effects for some recent data collected from literature. The first effect, the modification of interface shear stresses in annular flow pattern is considered through incorporation of the so called "blowing parameter". The mechanism of...
-
Reactive deposition of TiNx layers in a DC-magnetron discharge
PublicationTiNx layers have been deposited in 'balanced mode' and 'unbalanced mode' of a reactive DC-magnetron plasma (carrier gas argon, reactive gas nitrogen) under different conditions. Discharge power and reactive gas flow have been varied. The layers have been examined by X-ray photoelectron spectroscopy (XPS), X-ray reflectometry (XR), and spectroscopic ellipsometry (SE). The results of the layer analyses were combined with plasma investigations...
-
Recovery and re-use of photovoltaic solar cells from crystalline silicon
PublicationCrystalline silicon-type PV modules consist, in order of mass, of glass, an aluminium frame, an EVA coating, solar cells, a terminal box, back film and tapping screws. From the economic point of view, pure silicon, recoverable from spent cells, is the most important material owing to its cost and shortage. For crystalline, silicon-based PV cells, the following chemical treatments were performed: removal of the metal coating, followed...
-
Optical and photoelectrochemical characterization of pulsed laser deposited Bi4V2O11, BICUVOX, and BIZNVOX
PublicationThin layers of three compounds from the BIMEVOX family (Bi4V2O11, Bi2V0.9Cu0.1O5.35, and Bi2V0.9Zn0.1O5.35) were prepared via pulsed laser deposition technique on quartz, silicon, and platinum foil and tested as photoanodes for water photooxidation. The film formation, as well as the crystallization upon heating, was characterized using X-ray diffraction and Raman spectroscopy. The optical properties were investigated using spectroscopic...
-
Fabrication and Crystal Structure of Sol-Gel Deposited BST Thin Films with Compositional Gradient
PublicationIn the present research technology of compositionally graded barium strontium titanate Ba1-xSrxTiO3 thin films deposited on stainless steel substrates by sol-gel spin coating followed with thermal annealing at T = 650°C is reported. Results of thermal behavior of the sol-gel derived powders with compositions used for fabrication of graded structure (i.e. with Sr mole fraction x = 0.5, 0.4 and 0.3) are described. X-ray diffraction...
-
Recycling of photovoltaic modules - legal status, technology, market prospects
PublicationThe increase in the number of manufactured and installed photovoltaic modules and the growing concern about the insufficient supply of pure silicon imply the need to take action to develop infrastructure for recycling PV modules. The article presents a multifaceted analysis of the current state of development of the photovoltaic module recycling sector from a global and national perspective. The essence of the issue was introduced...
-
Room temperature depinning of the charge-density waves in quasi-two-dimensional 1T-TaS2 devices
PublicationWe report on the depinning of nearly commensurate charge-density waves in 1T-TaS2 thin films at room temperature. A combination of the differential current–voltage measurements with the low-frequency noise spectroscopy provides unambiguous means for detecting the depinning threshold field in quasi-2D materials. The depinning process in 1T-TaS2 is not accompanied by an observable abrupt increase in electric current—in striking contrast...
-
Solid State Conductivity of Optimized Polypyrrole Coatings on Iron Obtained from Aqueous Sodium Salicylate Solution Determined by Impedance Spectroscopy
PublicationIn this work the optimization procedure for corrosion resistance, surface analysis and electrical properties of PPy-Fe electrodes have been examined. Polypyrrole (PPy) film was electrochemically synthesized in a one step process from an aqueous solution of sodium salicylate and pyrrole with certain concentrations, different parameters and type of polymerization...
-
Tailoring Electro/Optical Properties of Transparent Boron-Doped Carbon Nanowalls Grown on Quartz
PublicationCarbon nanowalls (CNWs) have attracted much attention for numerous applications in electrical devices because of their peculiar structural characteristics. However, it is possible to set synthesis parameters to vary the electrical and optical properties of such CNWs. In this paper, we demonstrate the direct growth of highly transparent boron-doped nanowalls (B-CNWs) on optical grade fused quartz. The effect of growth temperature...
-
The selected roof covering technologies in the aspect of their life cycle costs
PublicationIn the article is presented an analysis of the life cycle costs calculation for selected roof coverings. The scope of research includes costs of construction, maintenance and demolition of the roof covering structure for two alternative technologies – the traditional and new generation. On the presented example of an industrial building with a roof area of 1000 m², the above costs are taken to consideration for the roof covering...
-
ECG measurement in the bathtub - getting into the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Dielectric Spectroscopy Studies and Modelling of Piezoelectric Properties of Multiferroic Ceramics
PublicationCompounds and solid solutions of bismuth ferrite (BiFeO3)—barium titanate (BaTiO3) system are of great scientific and engineering interest as multiferroic and potential high-temperature lead-free piezoelectric materials. In the present paper, the results of research on the synthesis and characterisation of 0.67Bi1.02FeO3–0.33BaTiO3 (67BFBT) ceramics in terms of crystal structure and dielectric and piezoelectric properties are reported....
-
The influence of dynamic load changes on temporary impedance in hydrogen fuel cells, selection and validation of the electrical equivalent circuit
PublicationTo achieve optimal performance of a fuel cell, a reliable monitoring and diagnostic method is required. The currently utilized methods give limited information or they are impossible to use under dynamic working conditions. To obtain comprehensive information about the fuel cell operation we utilized novel dynamic electrochemical impedance spectroscopy. Impedance measurements in dynamic mode were performed on a hydrogen fuel cell,...
-
Effectiveness of a dual surface modification of metallic interconnects for application in energy conversion devices
PublicationA dual surface modification of an SOFC metallic interconnect with a Gd2O3 layer and an MnCo2O4 coating was evaluated. The tested samples were oxidized for 7000 h in air at 1073 K. Oxidation products were characterized using XRD, SEM-EDS, and confocal Raman imaging, and ASR was measured. The effect of gadolinium segregation at grain boundaries in Cr2O3 was evaluated using S/TEM-EDS. Area specific-resistance was measured and fuel...
-
Hebb–Wagner polarization method for determining the oxygen ion conductivity in barium cerate-zirconate
PublicationIn this work, the partial conductivity of oxygen ions in BaCe0.6Zr0.2Y0.2O3 was studied at different temperatures and water partial pressures. For this purpose, a modified DC Hebb–Wagner polarization method with an electrode blocking for protons and electrons was used. A new type of measuring cell as well as a suitable calculation model were proposed for the determination of partial oxygen ionic conductivity in materials with three...
-
Investigation of Narrow Transverse and Longitudinal Electrostatic Precipitators
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...
-
Diffusible Hydrogen Control in Flux Cored Arc Welding Process
PublicationOne of the types of hydrogen degradation of steel welded joints is cold cracking. The direct cause of the formation of cold cracks is simultaneous presence of hydrogen, residual stresses and brittle structure. The way of preventing the occurring of degradation is to eliminate at least one of these factors. Practice has shown that the best solution is to control the amount of hydrogen in deposited metal. In this paper an experimental...
-
Consciousness Study of Subjects with Unresponsive Wakefulness Syndrome Employing Multimodal Interfaces
PublicationThe paper presents a novel multimodal-based methodology for consciousness study of individuals with unresponsive wakefulness syndrome. Two interfaces were employed in the experiments: eye gaze tracking system – CyberEye developed at the Multimedia Systems Department, and EEG device with electrode placement in the international 10-20 standard. It was a pilot study for checking if it is possible to determine objective methods based...
-
Low-power microwave-induced fabrication of functionalised few-layer black phosphorus electrodes: A novel route towards Haemophilus Influenzae pathogen biosensing devices
PublicationIn this paper, various passivation schemes were applied at few-layer black phosphorus (FLBP) to achieve covalent functionalisation with 4-azidobenzoic acid, improving its electrochemical response intended for analytical and biosensing applications. The thermal and microwave assisted modification procedures in toluene and dime-thylformamide resulted in high reversibility of reactions on functionalised FLBP using a ferricyanide/ferrocya-nide...
-
The valance state of vanadium-key factor in the flexibility of potassium vanadates structure as cathode materials in Li-ion batteries
PublicationPotassium hexavanadate (K2V6O16·nH2O) nanobelts have been synthesized by the LPE-IonEx method, which is dedicated to synthesis of transition metal oxide bronzes with controlled morphology and structure. The electrochemical performance of K2V6O16·nH2O as a cathode material for lithium-ion batteries has been evaluated. The KVO nanobelts demonstrated a high discharge capacity of 260 mAh g−1, and long-term cyclic stability up to 100...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...