Filters
total: 5701
-
Catalog
displaying 1000 best results Help
Search results for: LEAKAGE CURRENT MEASUREMENT
-
Programmable Input Mode Instrumentation Amplifier Using Multiple Output Current Conveyors
PublicationIn this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field...
-
Machine learning-based prediction of residual drift and seismic risk assessment of steel moment-resisting frames considering soil-structure interaction
PublicationNowadays, due to improvements in seismic codes and computational devices, retrofitting buildings is an important topic, in which, permanent deformation of buildings, known as Residual Interstory Drift Ratio (RIDR), plays a crucial role. To provide an accurate yet reliable prediction model, 32 improved Machine Learning (ML) algorithms were considered using the Python software to investigate the best method for estimating Maximum...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublicationA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
Monitoring of current collectors on the railway line
PublicationProper cooperation the current collectors and the overhead line is a pre-requisite for reliable and safe operation of railway transport. Instances of maladjustment and, in some cases, damage to the current collectors, occur between periodic inspections of the rolling stock. In order to detect such anomalies quickly, the test stand was developed, with the aim of monitoring the technical state of the current collectors under operating...
-
Analysis of measurement uncertainty for contact-less method used to measure the position of catenary contact wire, performed with the use of Monte Carlo method
PublicationCurrently the majority of main railway lines in Europe are electrified, and electric trains have the biggest share in the entire amount of rail transport. Reliability of electrified railways is closely related to the issue of supplying traction vehicles with energy. The problems connected with diagnostics of energy consumption node, namely the contact line and the current collector, are therefore of fundamental importance for maintaining...
-
Low-coherence method of hematocrit measurement
PublicationDuring the last thirty years low-coherence measurement methods have gained popularity because of their unique advantages. Low-coherence interferometry, low-coherence reflectometry and low-coherence optical tomography offer resolution and dynamic range of measurement at the range of classical optical techniques. Moreover, they enable measurements of the absolute value of the optical path differences, which is still an unsolved problem...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublicationAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
A measurement system for children endurance tests
PublicationThere are a lot of ethical problems concerning the use of invasive methods for the measurement of a child's body response to physical exercise and physical training. The alternative is are non-invasive methods like ergospirometry or NIRS. The article presents a measurement system dedicated for children endurance tests, composed of a few non-invasive measurement modules, including a temperature measurement module. Temperature is...
-
An Innovative New Approach to Light Pollution Measurement by Drone
PublicationThe study of light pollution is a relatively new and specific field of measurement. The current literature is dominated by articles that describe the use of ground and satellite data as a source of information on light pollution. However, there is a need to study the phenomenon on a microscale, i.e., locally within small locations such as housing estates, parks, buildings, or even inside buildings. Therefore, there is an important...
-
Modelowanie matematyczne górnej sieci trakcyjnej dla potrzeb diagnostyki odbieraków prądu
PublicationGórna sieć trakcyjna jest obecnie najbardziej skutecznym sposobem zasilania kolejowych pojazdów elektrycznych. Wzrost prędkości pojazdów zwiększa pobór mocy i wymaga zapewnienia właściwej współpracy odbieraków prądu pojazdów z siecią jezdną. Metody modelowania i projektowania wspomaganego komputerowo dla górnej sieci trakcyjnej są obecnie na całym świecie szeroko rozwijane. W artykule przedstawiono nowy model matematyczny elementów...
-
Statistics of AFM current-voltage curves
Open Research DataMapping surface electrical conductivity offers enormous cognitive possibilities regarding the structure and properties of modern materials. The technique invented for this purpose (Conductive AFM) by Murrel's team and colleagues allows independent monitoring of the local conductivity of materials in correlation with the topographic profile. The mentioned...
-
MEASUREMENT TECHNIQUES
Journals -
Measurement: Sensors
Journals -
MEASUREMENT & CONTROL
Journals -
Uncertainty of mass flow measurement using centric and eccentric orifice for Reynolds number in the range 10,000 ≤ Re ≤ 20,000
PublicationThe article analyses the impact of the Reynolds number on the estimated uncertainty of the mass flow rate measurement using an orifice plate. The objects of the research were two types of orifices: centric (ISA) and eccentric, with the diameter ratio β = 0.5. Studies were performed by Monte Carlo simulation and experiments for Reynolds numbers in the range 10,000 ≤ Re ≤ 20,000. The obtained results have shown that for both orifice...
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublicationAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
TiO 2 Co x O y composite nanotube arrays via one step electrochemical anodization for visible light–induced photocatalytic reaction
PublicationTiO2CoxOy (x = 1, y = 1 or x = 3, y = 4) composite photocatalysts have been synthesized via one step anodic anodization of TiCo alloys. The effects of the cobalt content in the alloy (5, 10 and 15 wt%), water content (2, 5 and 10%) in the electrolyte solution, and applied voltage (30, 40 and 50 V) during the anodization process on the morphology and surface properties. Additionally, the dependence of cobalt content in the nanotubes...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublicationDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Current based Normalized Triple Covariance as a bearings diagnostic feature in induction motor
PublicationDiagnosis of induction motors, conducted remotely by measuring and analyzing the supply current is attractive with the lack of access to the engine. So far there is no solution, based on analysis of current, the credibility of which allow use in industry. Statistics of IM bearing failures of induction motors indicate, that they constitute more than 40% of IM damage, therefore bearing diagnosis is so important. The article provides...
-
Grzegorz Lentka dr hab. inż.
PeopleGrzegorz Lentka obtained his MSc title in electronics, specialization Measurement Systems at Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics in 1996. He obtained the PhD title in 2003 and habilitation in 2014, respectively. Currently he is an professor in Department of Metrology and Optoelectronics. His main scientific interests are focused on digital signal processing for metrology,...
-
Reducing the Uncertainty of the Moving Object Location Measurement with the Method of Quasi-Multiple Measurement in GNSS Technology in Symmetrical Arrangement
PublicationThe article presents a solution to the problem of limited accuracy of dynamic measurements performed with GNSS receivers. The proposed measurement method is a response to the needs related to the assessment of the measurement uncertainty of the position of the track axis of the rail transport line. However, the problem of reducing the measurement uncertainty is universal for many different situations where high accuracy of positioning...
-
Impact of probability distribution on the uncertainty of resistance measurement
PublicationThe paper presents studies on the influence of probability distributions on the expanded uncertainty of the resistance measurement. Choosing the correct probability distribution is very important to estimate of measurement uncertainty. The paper presents the results of analysis of the resistance measurement uncertainty using the technical method of resistance: 100 G. The analysis of the uncertainty...
-
An Insight into the Stages of Ion Leakage during Red Blood Cell Storage
Publication -
Kernel PCA in Application to Leakage Detection in Drinking Water Distribution System
Publication -
Low-power device simulator for micro-energy measurement methods testing
PublicationThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Aleksandra Parteka dr hab. inż.
PeopleAbout me: I am an associate professor and head of doctoral studies at the Faculty of Management and Economics, Gdansk University of Technology (GdanskTech, Poland). I got my MSc degree in Economics from Gdansk University of Technology (2003) and Universita’ Politecnica delle Marche (2005), as well as MA degree in Contemporary European Studies from Sussex University (2006, with distinction). I received my PhD in Economics...
-
Distance measurement errors in silent FM-CW sonar with matched filtering
PublicationThe secretiveness of sonar operation can be achieved by using continuous frequency-modulated sounding signalswith reduced power and significantly prolonged repeat time. The application of matched filtration in the sonarreceiver provides optimal conditions for detection against the background of white noise and reverberation, and avery good resolution of distance measurements of motionless targets. The article shows that target...
-
USE OF LANGMUIR PROBE IN DIESEL ENGINE DIAGNOSTIC RESEARCH Part I MEASUREMENT TECHNOLOGY. - Part 1 : MEASUREMENT TECHNOLOGY
PublicationIn the paper, the basic assumptions of diesel engine cylinder system's diagnosing method, based on observation of emerging and moving electric charges of ionized gas in the combustion workspaces, using Langmuir's probe. In the first part of the paper, only the technology of the measurement and results of the preliminary diagnostic tests of laboratory engine Farymann Diesel D10 were presented. The primary purpose of the research...
-
CURRENT PSYCHOLOGY
Journals -
Current Issues in Pharmaceutical Residues in Drinking Water
Publication -
Tripping limitations of residual current devices in photovoltaic installations
PublicationIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...
-
Current-based higher-order spectral covariance as a bearing diagnostic feature for induction motors
PublicationConducting the diagnosis of induction motors remotely by analyzing the supply current is an attractive prospect with the lack of access to the engine. Currently, there is no solution, based on analysis of the current, the credibility of which would allow its use in industry. The statistics of bearing failures in induction motors indicate that they constitute more than 40% of induction motor damage, therefore, bearing diagnosis...
-
IMPACT OF DIRECT CURRENT ON NITRIFYING BIOMASS
PublicationEffects of short term exposure of nitrifying biomass to direct current were studied. DC was applied to mixed liquor from municipal BNR plant using graphite electrodes in no substrate limiting conditions. Both, ammonia oxidizing bacteria (AOB) and nitrite oxidizing bacteria (NOB) populations were affected by the current, however in opposite ways. The AOB population activity was inhibited by applied voltage. Activity decrease was...
-
CURRENT MEDICINAL CHEMISTRY
Journals -
Low-frequency tripping characteristics of residual current devices
PublicationFast development of various types of converters makes their utilization in industry and in domestic installations very common. Due to converters, an earth fault current waveform in modern circuits can be distorted or its frequency can be different than 50/60 Hz. Frequency of earth fault (residual) current influences tripping of residual current devices which are widely used in low voltage systems. This paper presents the behaviour...
-
A concept of measurement system based on the Z-Wave standard
PublicationIn the paper a new concept of measurement system based on the Z-Wave standard is presented. This standard is dedicated to use mainly in home automation systems, but its properties enable to use it in dispersed measurement systems and support wireless communication between measurement nodes in a mesh-type network. In the paper basic metrological aspects of the Z-Wave standard and an example of impedance measurement system are discussed.
-
Sensorless IPMSM drive with rotor position estimator based on analysis of phase current derivatives
PublicationThis paper describes a sensorless Interior Permanent Magnet Synchronous Motor (IPMSM) drive designed for traction applications. Wide-speed sensorless operation is provided with the use of three methods of rotor position estimation designed for: a standstill, low- and high-speed range. The paper focuses on the high-speed estimation algorithm. The estimator uses the derivatives of motor phase currentsresulting from PWM modulation...
-
FLOW MEASUREMENT AND INSTRUMENTATION
Journals -
Current Source Inverter Fed Drive
PublicationThis book covers three-phase and multiphase (more than three-phase) motor drives including their control and practical problems faced in the field (e.g., adding LC filters in the output of a feeding converter), are considered. The new edition contains links to Matlab®/Simulink models and PowerPoint slides ideal for teaching and understanding the material contained within the book. Readers will also benefit from the inclusion of: A...
-
Measurements and Measurement Systems [WIMiO][2023/24]
e-Learning Courses -
Scalable Measurement System for Multiple Impedance Gas Sensors
PublicationAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...
-
FAILURE OF MAGNETIC FLUID SEALS OPERATING IN WATER: PRELIMINARY CONCLUSIONS
PublicationThe article analyses properties of magnetic fluid seals installed in rotary sealing no des which operate in the utility water environment. Seals of this type have been examined as a possible solution to the problem with ship manoeuvring propulsion sealing. The present analysis bases on laboratory durability tests of magnetic fluid seals expo sed to long - term utility water loads, at different water pressures and shaft revolutions....
-
Discrete measurement of fault-arc velocity
PublicationOpisano metodę dyskretnego pomiaru prędkości jednofazowego łuku awaryjnego poruszającego się w płaskim, poziomym układzie szyn. Badania przeprowadzono za pomocą punktowych czujników optycznych rozmieszczonych równomiernie wzdłuż szyn. Podano opis układu, jego charakterystykę, wpływ obszaru zjonizowanego na uzyskiwane wyniki i zależności między obserwowanymi wielkościami.
-
Tax system in Poland - current situation and direction of changes
Open Research DataThe study conducted on a group of 259 entrepreneurs from various regions of Poland concerns the opinions of business owners on the current tax situation, as well as potential changes in the tax system.
-
Protection of bridges against stray current corrosion
PublicationA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
-
Wear estimation of current collector contact strips by analysis of a 3D scanning results
PublicationThe technical condition of current collector contact strips is very important when operational reliability of railway transportation is considered. The authors proposed a novel measurement system based on a 3D camera to register the shape and dimensions of the current collector contact strips surface. The system was installed above the railway track for tests in target ambient. During the trial operation a few dozen of contact...
-
An analysis of a measurement probe for a high impedance spectroscopy analyzer
PublicationW artykule przedstawiono sondę będącą obwodem wejściowym analizatora do spektroskopii wysokoimpedancyjnej. Sonda umożliwia pomiar impedancji jednym zaciskiem uziemnionej w zakresie od 100ohm do 100Gohm. Sonda umożliwia wydzielenie dwóch sygnałów proporcjonalnych do prądu i napięcia na impedancji mierzonej w szerokim zakresie częstotliwosci od 100uHz do 100MHz.Przeprowadzono analizę sondy w której uwzględniono najważniejsze czynniki...