Filters
total: 505
filtered: 418
-
Catalog
Chosen catalog filters
Search results for: DETEKTORY CHROMATOGRAFICZNE
-
Radioisotope measurements of the liquid-gas flow in the horizontal pipeline using phase method
PublicationThe paper presents application of the gamma-absorption method to a two-phase liquid-gas flow investigation in a horizontal pipeline. The water-air mixture was examined by a set of two Am-241 radioactive sources and two NaI(Tl) scintillation probes. For analysis of the electrical signals obtained from detectors the cross-spectral density function (CSDF) was applied. Results of the gas phase average velocity measurements for CSDF...
-
Determination of estrogenic endocrine disruptors in environmental samples - a review of chromatographic methods
PublicationWśród związków endokrynnych to estrogeny zarówno naturalne jak i syntetyczne zostały wskazane i opisane jako związki niosące ze sobą największy potencjał aktywności estrogennej. Wysoki potencjał estrogenny jaki posiadają związki z grupy hormonów płciowych potwierdziły badania przeprowadzone zarówno in vitro jak i in vivo. W dużej części (50-95%) próbek ścieków pochodzących z oczyszczalni ścieków zostały wykryte związki z grupy...
-
Analog fault signature based on sigma-delta modulation and oscillation-test methodology.
PublicationW artykule dokonano przeglądu prac z zakresu testowania układów elektronicznych metodą oscylacyjną. Wskazując na niedostatki aktualnie stosowanej techniki testowania oscylacyjnego zaproponowano nową sygnaturę uszkodzeń dla układów analogowych. Proponowany parametr diagnostyczny jest wydobywany z odpowiedzi czasowej oscylatora testującego, w układzie złożonym z detektora szczytowego, modulatora sigma-delta oraz licznika rewersyjnego....
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublicationIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Methods of assaying volatile oxygenated organic compounds in effluent samples by gas chromatography—A review
PublicationThe paper is a review of the procedures for the determination of volatile and semivolatile oxygenated organic compounds (O-VOCs) in effluent samples by gas chromatography. Current trends and outlook for individual steps of the procedure for the determination of O-VOCs in effluents are discussed. The available sample preparation techniques and their limitations are described along with GC capillary columns used for O-VOCs separation...
-
Quantum randomness protected against detection loophole attacks
PublicationDevice and semi-device-independent private quantum randomness generators are crucial for applications requiring private randomness. However, they are vulnerable to detection inefficiency attacks and this limits severely their usage for practical purposes. Here, we present a method for protecting semi-device-independent private quantum randomness generators in prepare-and-measure scenarios against detection inefficiency attacks....
-
Fazy stacjonarne na bazie pochodnych kaliks[4]arenów w konformacji 1,3-naprzemianległej chemicznie związanych z żelem krzemionkowym, jako nowy typ wypełnień w chromatografii cieczowej
PublicationW prezentowanym opracowaniu monograficznym przedstawione zostały wyniki badań autorki dotyczące wykorzystania pochodnych kaliks[4]arenów w konformacji 1,3-naprzemianległej do otrzymywania nowego typu wypełnień kolumn chromatograficznych. Pierwsza część pracy jest przeglądem literaturowym dotyczącym syntezy kaliksarenów, ich budowy, różnorodności konformacyjnej, a także możliwości modyfikacji zarówno w obrębie górnej, jak i dolnej...
-
Removal of sulfur from a solvent extract
PublicationThe presence of sulfur in a solvent extract that is to be analyzed chromatographically impairs and sometimes precludes properinterpretation of the chromatogram, as the sulfur peak masks the peaks of other compounds present in the sample, and sulfur alsodisrupts the operation of the mass detector. This means that discrepancies in the results can lead to erroneous interpretations andfalse assessments of environmental risk. For this...
-
Style Transfer for Detecting Vehicles with Thermal Camera
PublicationIn this work we focus on nighttime vehicle detection for intelligent traffic monitoring from the thermal camera. To train a Convolutional Neural Network (CNN) detector we create a stylized version of COCO (Common Objects in Context) dataset using Style Transfer technique that imitates images obtained from thermal cameras. This new dataset is further used for fine-tuning of the model and as a result detection accuracy on images...
-
Badania symulacyjne dynamicznej odporności na zakłóceniacyfrowych układów kombinacyjnych.
PublicationPrzedstawiono opracowaną przez autorów metodę pomiaru dynamicznej odporności na zakłócenia układów cyfrowych z zastosowaniem szerokopasmowego wzorcowego sygnału szumowego. Modyfikacja metody polega na dodatkowym ograniczeniu szerokości pasma sygnału stymulującego. Przeprowadzono badania symulacyjne dla kilku modeli badanych układów cyfrowych, w tym modelu detektora progowego oraz szybkiego komparatora z histerezą, mające na celu...
-
Nowe techniki instrumentalne na tle tradycyjnych metod analizy stabilności oksydatywnej olejów roślinnych
PublicationObiecującą metodą oznaczania stabilnosci oksydatywnej olejów roślinnych może okazać się technika mikroekstrakcji do fazy stacjonarnej połączona z techniką chromatografii gazowej (SPME/GC) z detektorem płomieniowo-jonizacyjnym (FID) lub spektrometrii mas (MS). Przy pomocy wspomnianej metody, na podstawie zależności stosunku stężeń heksanalu do 2-trans-nonenalu w funkcji czasu naświetlania promieniowaniem ultrafioletowym, wyznaczono...
-
Investigation of volatile low molecular weight compounds formed during continuous reclaiming of ground tire rubber
PublicationGround tire rubber was thermo-mechanically reclaimed at different temperature conditions (80, 120, 160 °C) using a co-rotating twin screw extruder. The progress of ground tire rubber reclaiming was evaluated with specific mechanical energy, sol fraction and thermogravimetric analysis. Volatile organic compounds (VOCs) including volatile sulfur compounds (VCSs) released from ground tire rubber and ground tire rubber after reclaiming...
-
Wykorzystanie bezrozpuszczalnikowych technik przygotowania próbek w procedurach oznaczania lotnych związków chlorowcoorganicznych w próbkach płynów biologicznych
PublicationDążność do oznaczania możliwie szerokiego spektrum analitów w próbkach charakteryzujących się złożonym, a często i zmiennym składem matrycy, stanowi siłę napędową do działań analityków w zakresie poszukiwania zarówno nowych rozwiązań metodycznych jak i aparaturowych. Szczególnie w przypadku ciekłych próbek środowiskowych i biologicznych konieczne są specjalne operacje i czynności (na etapie ich przygotowania) przed etapem oznaczeń...
-
Opracowanie nowych metodyk oznaczeń ilościowych i jakościowych izotiocyjanianów oraz związków indolowych w próbkach roślin z rodziny Brassicaceae
PublicationIzotiocyjaniany (ITC) i indole powstające w wyniku hydrolizy glukozynolanów obecnych w roślinach z rodziny Brassicaceae wykazują wysoką aktywność biobójczą w stosunku do fitofagów stanowiąc alternatywę dla syntetycznych pestycydów. Zaliczane są także do najważniejszych żywieniowych substancji przeciwzapalnych i przeciwrakotwórczych. Pomimo wielu zastosowań dotychczas brakowało metod analitycznych umożliwiających ich rutynowe oznaczanie....
-
Studies on origin of Polish honeys by two-dimensional gas chromatography Ocena pochodzenia surowcowego polskich miodów przy użyciu dwuwymiarowej chromatografii gazowej
PublicationPolish acacia, linden, rapessed and buckwheat-derived honeys and a honydew were analysed for presence of hydrocarbons, alcs., ketones and esters by 2-dimensional gas chromatog. to establish the markers for the honey origin. PrOH was found characteristic for acacia honey, Me(CH2)11OH for linden honey, Me(CH2)6CHOMe for honeydew and Me(CH2)8COOEt for the rapeseed honey. Wykorzystano technikę dwuwymiarowej chromatografii gazowej sprzężonej...
-
An Objective Focussing Measure for Acoustically Obtained Image
PublicationIn scientific literature many parameters of an image sharpness can be defined, that can be used for the evaluation of display energy concentration (EC). This paper proposes a new, simple approach to EC quantitative evaluation in spectrograms, which are used for the analysis and visualization of sonar signals. The presented approach of the global-image EC measure was developed to the evaluation of EC in arbitrary direction (or at...
-
Porous Phantoms Mimicking Tissues—Investigation of Optical Parameters Stability Over Time
PublicationOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods, while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom in optical system. Measurements were performed in multiple series with an interval...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublicationPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
System for monitoring road slippery based on CCTV cameras and convolutional neural networks
PublicationThe slipperiness of the surface is essential for road safety. The growing number of CCTV cameras opens the possibility of using them to automatically detect the slippery surface and inform road users about it. This paper presents a system of developed intelligent road signs, including a detector based on convolutional neural networks (CNNs) and the transferlearning method employed to the processing of images acquired with video...
-
Opracowanie optymalnych warunków rozdzielania i identyfikacji metabolitów ro lin z rodzaju droseraceae, z zastosowaniem wysokosprawnej kolumnowej chromatografii cieczowej= A research on the composition of eluent for separation of plant metabolites by column reversed phase liquid chromatography
PublicationOd kilku lat na świecie trwają badania składników roślin owadożernych wykazujących atrakcyjne właściwości biologicznie czynne, tj. działanie przeciwbakteryjne, przeciwgrzybowe, antyoksydacyjne, a być może, także, przeciwnowotworowe. Pozyskiwanie substancji biologicznieaktywnych z materiału naturalnego, na drodze hodowli in vitro a następnie ekstrakcji i rozdzielania jest bardziej korzystne pod względem ekonomicznym, niż ich wytwarzanie...
-
Identyfikacja naturalnych organicznych substancji barwiących obecnych w historycznych farbach i tekstyliach
PublicationW ramach badań opracowana została metoda izolacji i identyfikacji substancji barwiących obecnych w surowcach barwierskich, historycznych farbach i tkaninach. Optymalizacja metody izolacji barwników organicznych polegała na doborze takich parametrów jak: rodzaj ekstrahenta i jego stężenie, czas pracy łaźni ultradźwiękowej, temperatura procesu ekstrakcji oraz sposób oczyszczania analizowanych próbek. Kwas fluorowodorowy uznany został...
-
Detection and localization of selected acoustic events in 3D acoustic field for smart surveillance applications
PublicationA method for automatic determination of position of chosen sound events such as speech signals and impulse sounds in 3-dimensional space is presented. The events are localized in the presence of sound reflections employing acoustic vector sensors. Human voice and impulsive sounds are detected using adaptive detectors based on modified peak-valley difference (PVD) parameter and sound pressure level. Localization based on signals...
-
Comparison of various speech time-scale modificartion methods
PublicationThe objective of this work is to investigate the influence of the different time-scale modification (TSM) methods on the quality of the speech stretched up using the designed non-uniform real-time speech time-scale modification algorithm (NU-RTSM). The algorithm provides a combination of the typical TSM algorithm with the vowels, consonants, stutter, transients and silence detectors. Based on the information about the content and...
-
Quality evaluation of agricultural distillates using different types of electronic noses
PublicationThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with TGS type semiconductor sensors. HERACLES II included two chromatographic columns with different polarity of stationary phase and two FID detectors. In case of the prototype volatile fraction...
-
Detection and localization of selected acoustic events in acoustic field for smart surveillance applications
PublicationA method for automatic determination of position of chosen sound events such as speech signals and impulse sounds in 3-dimensional space is presented. The evens are localized in the presence of sound reflections employing acoustic vector sensors. Human voice and impulsive sounds are detected using adaptive detectors based on modified peak-valley difference (PVD) parameter and sound pressure level. Localization based on signals...
-
Investigation of Liquid–Gas Flow in a Horizontal Pipeline Using Gamma-Ray Technique and Modified Cross-Correlation
PublicationThis article presents the application of the radioisotope absorption method in the study of two-phase water–air flow in a horizontal pipe. The measurement principle and the test stand are briefly described. The main part of the article presents the signal analysis methods applied to data obtained from scintillation detectors. Because these signals are mostly stochastic waveforms, they were analyzed statistically using the cross-correlation...
-
Investigations of the Methods of Time Delay Measurement of Stochastic Signals Using Cross-correlation with the Hilbert Transform
PublicationThe article presents the results of simulation studies of four methods of estimating time delay for random signals using cross-correlation with the Hilbert Transform. Selected models of mutually delayed stochastic signals were used in the simulations, corresponding to the signals obtained from scintillation detectors in radioisotope measurements of liquid-gas two-phase flow. Standard deviations of the values of the individual functions...
-
Automatic analysis of the aggressive behavior of laboratory animals using thermal video processing
PublicationThe bite detection is very important but difficult element of the social interaction analysis. Standard observation methods like human observer or a camcorder of visible light frequencies fail in this case. However, it is possible to discern cooler spots on the rodent's body that appear after body contact with another individual, and vanish after short time. These spots are assumed to be a saliva trace left on fur after bite. In...
-
Semi complex navigation with an active optical gesture sensor
PublicationThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
Audio-visual surveillance system for application in bank operating room
PublicationAn audio-visual surveillance system able to detect, classify and to localize acoustic events in a bank operating room is presented. Algorithms for detection and classification of abnormal acoustic events, such as screams or gunshots are introduced. Two types of detectors are employed to detect impulsive sounds and vocal activity. A Support Vector Machine (SVM) classifier is used to discern between the different classes of acoustic...
-
Processing of acoustical data in a multimodal bank operating room surveillance system
PublicationAn automatic surveillance system capable of detecting, classifying and localizing acoustic events in a bank operating room is presented. Algorithms for detection and classification of abnormal acoustic events, such as screams or gunshots are introduced. Two types of detectors are employed to detect impulsive sounds and vocal activity. A Support Vector Machine (SVM) classifier is used to discern between the different classes of...
-
Nanostruktury metalicznego bizmutu w redukowanych szkłach bizmutowo-germanianowych i bizmutowo-krzemianowych: wytwarzanie, struktura i transport nośników ładunku.
PublicationW pracy przedstawiono rezultaty badań struktury i własności transportowych szkieł bizmutowo-germanianowych i bizmutowo-krzemianowych. Potwierdzono, że przewodnictwo elektryczne jest typu jonowego. Tymi jonami są jony tlenu. Opisano związek między kolorem szkieł, a koncentracją jonów tlenu. Zbadano wpływ wygrzewania w atmosferze wodoru na własności szkieł. Opisano w sposób jakościowy i ilościowy procesy tworzenia się w wyniku redukcji...
-
Problems of PAH quantification by GC-MS method using isotope-labelled standards.
PublicationChromatografia gazowa w połączeniu ze spektromerią mas (GC-MS) jest obecnie rutynowo stosowaną metodą w analityce środowiskowej do oznaczania śladowych ilości zanieczyszczeń organicznych. Stosowanie detektora mas sprawia, że wygodnym wzorcem wewnętrznym są stabilne izotopowo analogi oznaczanych związków. Związki te są wykorzystywane do śledzenia i kompensacji strat analitów podczas wykonywania określonych operacji związanych z...
-
Rozpoznawanie urządzeń i wykrywanie nieautoryzowanego poboru energii elektrycznej na podstawie pomiaru napięcia
PublicationW pracy rozpatrywany jest problem wykrywania nieautoryzowanego poboru energii z sieci elektrycznej przez identyfikację podłączonych urządzeń. Estymacja stanu sieci, rozumianej jako zbiór podpiętych układów, wraz z ustaloną listą urządzeń dopuszczonych, pozwala określić, czy w danej chwili ma miejsce pobór nieautoryzowany. W celu wykrywania urządzeń, proponuje się wykorzystać prostą metodę opartą na analizie wysokoczęstotliwościowego...
-
Characterization of TiO2 Modified with Bimetallic Ag/Au Nanoparticles Obtained in Microemulsion System
PublicationFotokatalizatory TiO2 modyfikowane nanocząstkami bimetalicznymi Ag/Au przygotowano metodą mikroemulsyjną w układzie woda/surfaktant/cykloheksan. Aktywność fotokatalityczna próbek Ag/Au-TiO2 oszacowano przez wyznaczenie stopnia degradacji fenolu pod wpływem światła VIS. Fenol został użyty jako model zanieczyszczeń, ponieważ jest substancją niebezpieczną dla środowiska. Najwyższą aktywność w zakresie światła widzialnego wykazała...
-
Integrated controller for ultra high frequency technique laboratory
PublicationDepartment of Microwave and Antenna Engineering decided to modernize the laboratory of Ultra High Frequency Techniques. The main change was to replace measurement of the field distribution inside rectangular waveguides by analysing the fields around striplines. This involved the need to overcome several technical and conceptual problems. Precise positioning of the probe and reading the field distribution near the stripline is important...
-
Audio codec employing frequency-derived tonality measure
PublicationA transform codec employing efficient algorithm for detection of spectral tonal components is presented. The tonality measure used in MPEG psychoacoustic model is replaced with the method providing adequate tonality estimates even if the tonal components are deeply frequency modulated. The reliability of hearing threshold estimated using psychoacoustic model with standardized tonality measure and the proposed one is investigated...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublicationIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Photoinduced and thermal oxidation of rapeseed and sunflower oils
PublicationCelem prezentowanych badań było porównanie stabilności oksydatywnej olejów rzepakowych i słonecznikowych. Na etapie przyspieszania utleniania zastosowano promieniowanie UV. Po naświetlaniu lotne produkty utlenienia były izolowane z fazy nadpowierzchniowej przy pomocy mikroekstrakcji do fazy stacjonarnej HS-SPME(włókno DVB/CAR/PDMS) i oznaczane z zastosowaniem chromatografii gazowej z detektorem płomieniowo-jonizacyjnym (GC/FID)....
-
Optical method supported by machine learning for dynamics of C‐reactive protein concentrations changes detection in biological matrix samples
PublicationIn this article we present the novel spectroscopy method supported with machine learning for real-time detection of infectious agents in wastewater. In the case of infectious diseases, wastewater monitoring can be used to detect the presence of inflammation biomarkers, such as the proposed C-reactive protein, for monitoring inflammatory conditions and mass screening during epidemics for early detection in communities of concern,...
-
Signals features extraction in radioisotope liquid-gas flow measurements using wavelet analysis
PublicationKnowledge of the structure of a flow is significant for the proper conduct of a number of industrial processes. In this case, a description of a two-phase flow regimes is possible by use of the time-series analysis in time, frequency and state-space domain. In this article the Discrete Wavelet Transform (DWT) is applied for analysis of signals obtained for water-air flow using gamma ray absorption. The presented method was illustrated...
-
Analysis of arsenic species in environmental samples
PublicationMany analytical methods for determining arsenic in various forms in environmental samples have been developed in recent years. The main objective of this review article is the presentation and comparison of the three principal techniques for the determination arsenic compounds, namely: hydride generation (HG), voltammetry and chromatography (liquid chromatography including high-performance liquid chromatography (HPLC), and gas...
-
Detekcja uszkodzeń w analogowych układach w pełni różnicowych.
PublicationPrzedmiotem pracy jest detekcja uszkodzeń w analogowych układach elektronicznych o architekturze w pełni różnicowej, cechującej się strukturalną redundancją ułatwiającą testowanie i diagnostykę. W oparciu o model matematyczny układów w pełni różnicowych, usystematyzowano metody ich testowania. Wykazano, że dotychczas stosowane metody są kosztowne w odniesieniu do układów ze wzmacniaczami operacyjnymi, w których zastosowano sprzężenie...
-
Solvent residue determination in Uncaria Tomentosa Bark by HS-GC technique
PublicationPrzedstawiono wyniki oznaczeń pozostałości rozpuszczalników organicznych w preparacie uzyskanym z kory liany U. Tomentosa, wykorzystywanej do produkcji farmaceutyków i dodatków do żywności. 1,1,2-trichloroeten oraz dichlorometan są powszechnie stosowane do usunięcia z kory kilku grup alkaloidów o znanych właściwościach biologicznych, co umożliwia zbadanie pozostałych jej związków. Ilościowe oznaczanie tych rozpuszcalników jest...
-
Wielowymiarowa chromatografia cieczowa jako technika przygotowania próbki i oznaczania składu grupowego skomplikowanych mieszanin substancji
PublicationCelem ogólnym niniejszej rozprawy doktorskiej jest opanowanie problemu doboru optymalnych warunków przygotowania próbki, z uwzględnieniem rozdzielania grupowego w celu zapewnienia możliwości oznaczania zawartości wybranych analitów lub grup analitów w materiałach stanowiących skomplikowane mieszaniny bardzo wielu substancji. W części wprowadzającej pracy dokonano przeglądu i poddano krytycznej ocenie istniejące techniki i metody...
-
Immunochromatografia : przegląd i charakterystyka immunosorbentów oraz metod immobilizacji = Immunochromatography: a review and characterization of immunosorbents and methods of immobilization
PublicationChromatografia immunopowinowactwa (ang. ImmunoAffinity Chromatography, IAC) jest techniką rozdzielania stosowaną do różnorodnych klas związków chemicznych, a także jako dodatkowe narzędzie w badaniach z zakresu biochemii. Kluczowym elementem odpowiedzialnym za wysoce selektywne oddziaływania w IAC jest przeciwciało (ang. antibody, Ab) produkowane przez organizmy żywe w wyniku odpowiedzi immunologicznej i wykazujące specyficzność...
-
Determination of volatile organohalogen compounds in urban precipitation in Tricity area (Gdańsk, Gdynia, Sopot).
PublicationPróbki opadów atmosferycznych pobierano w 4 punktach na terenie Gdańska i Sopotu, od listopada 2000 do maja 2001. Oznaczano chloro- i bromopochodne metanu, etanu i etenu. Lotne związki chlorowcoorganiczne oznaczane były metodą bezpośredniego nastrzyku próbki wody do kolumny kapilarnej z wykorzystaniem detektora wychwytu elektronów na etapie detekcji (DAI-GC-ECD). Najczęściej oznaczanymi związkami na wszystkich stacjach pobierania...
-
Occurence volatile halogenoorganic compounds in precipitation in an urban area in Tricity (Gdańsk-Gdynia-Sopot). Występowanie lotnych związków fluorowcoorganicznych w opadach atmosferycznych na terenie miejskim.
PublicationSzczególne znaczenie wśród zanieczyszczeń występujących w wielkomiejskim powietrzu atmosferycznym, mają lotne związki chlorowcoorganiczne, ze względu na powszechność stosowania i trwałość (od 77 dni - CH2Cl2 do 67 lat - CCl4). Większość związków chlorowcoorganicznych stanowi zagrożenie dla życia ludzkiego przez swoje kancerogenne, mutagenne i teratogenne działanie. Związki chlorowcoorganiczne obecne w środowisku są w większości...
-
Low cost microwave X-band generator
PublicationA low cost microwave X-band generator for educational purposes was designed and built. Its simple construction and user's interface makes it suitable for a student laboratory.The generator is based on a single frequency conversion concept. It uses a digitally tunable PLL chip for intermediate frequency generation and an active frequency multiplier for frequency conversion. The generator covers 9,7 - 11 GHz part of the X frequency...
-
A procedure for the determination of dichloromethane and tetrachloroethene in water using pervaporation and gas chromatography
PublicationIn the present study, pervaporation was applied to the determination of tetrachloroethene (PCE) and dichloromethane (DCM) in liquid samples. PCE is the most commonly used solvent in dry-cleaning processes. PCE belongs to group 2A of carcinogens (probably carcinogenic to humans) according to the classification of the International Agency for Research on Cancer (IARC). DCM is also widely used as an industrial solvent for the purification...