Filters
total: 2624
filtered: 2023
-
Catalog
- Publications 2023 available results
- Journals 31 available results
- Conferences 11 available results
- Publishing Houses 1 available results
- People 36 available results
- Inventions 1 available results
- Projects 7 available results
- Research Teams 2 available results
- Research Equipment 1 available results
- e-Learning Courses 31 available results
- Events 1 available results
- Open Research Data 479 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: INVARIANTS, TENSORS, DISSIPATION, ENSTROPHY
-
Wireless data transmission for fiber optical sensor system
PublicationW artykule opisano możliwość wykorzystania bezprzewodowego systemu transmisji danych do transmisji sygnałów z czujników światłowodowych.
-
Influence of Humidity on Parameters of Amperometric Sensor with Nafion Membrane
PublicationPrzedstawiono wyniki badań wpływu umiarkowanych i wysokich wilgotności powietrza na sygnał, czułość i czas odpowiedzi prototypowego czujnika ditlenku siarki ze złotą elektrodą pracującą, próżniowo napyloną na powierzchnię membrany nafionowej. Zaprezentowano także wyniki badań impedancyjnych w zakresie potencjałów, w którym mechanizm utleniania ditlenku siarki jest kontrolowany aktywacyjnie i dyfuzyjnie. Parametry odpowiadające...
-
Analog multiplier for a low-power integrated image sensor
PublicationArtykuł przedstawia nowe podejście do projektowania tanich niskomocowych zintegrowanych sensorów optycznych. W odróżnieniu od wcześniej stosowanych rozwiązań opartych na masowym przetwarzaniu równoległym, zaproponowany mnożnik macierzowy charakteryzuje się korzystniejszymi cechami. Proponowane rozwiązanie, chociaż mniej elastyczne w sensie liczby możliwych do zaimplementowania algorytmów wstępnej obróbki obrazu, cechuje się znaczącą...
-
A model of the response of the MGS-6 gravity sensor to tilting
PublicationThe reliable interpretation of the measurements made by the Micro-g marine gravimetric system (MGS-6) depends on how the temporary changes of the scale coefficients such as gravimeter scale factor, vertical cross-coupling (VCC) effect, tiltmeter cross and tiltmeter long are compensated for during the signal analysis. The listed coefficients cannot be determined from readings during the measurements or by analysing the final data....
-
Distributed Trust Management Model for Wireless Sensor Networks
Publication -
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Influence of operation temperature instability on gas sensor performance
PublicationGas sensors based on the semiconducting metal-oxides, such as SnO2, have been found to be very useful for detecting a wide range of gases. The reversible interactions of the gas with the surface of the sensing layer made of semiconducting metal-oxides are responsible for changes of sensor resistance which is usually used as a measure of sensor response. Semiconductor gas sensors are commercially available and applied in numerous...
-
The passive operating mode of the linear optical gesture sensor
PublicationThe study evaluates the influence of natural light conditions on the effectiveness of the linear optical gesture sensor, working in the presence of ambient light only (passive mode). The orientations of the device in reference to the light source were modified in order to verify the sensitivity of the sensor. A criterion for the differentiation between two states - "possible gesture" and "no gesture" - was proposed. Additionally,...
-
A novel sensor for measuring temperature profile during the thermoablation
PublicationAbstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...
-
Determination of the Vehicles Speed Using Acoustic Vector Sensor
PublicationThe method for determining the speed of vehicles using acoustic vector sensor and sound intensity measurement technique was presented in the paper. First, the theoretical basis of the proposed method was explained. Next, the details of the developed algorithm of sound intensity processing both in time domain and in frequency domain were described. Optimization process of the method was also presented. Finally, the proposed measurement...
-
Planar Microwave Bragg Reflector Resonant Dielectric Sensor
PublicationIn this paper, a periodic structure is used to design a microwave Bragg reflector with the help of hexagonal lattice, which provides a 5 GHz wide stopband between the low-pass band with cut-off frequency 2.6 GHz and the bandpass response with start and stop frequency 7.8 GHz and 10.5 GHz, respectively. A defect in lattice allows passing a narrowband signal at 6 GHz which is found, from the dispersion relation, to be in the region...
-
Localization of sound sources with dual acoustic vector sensor
PublicationThe aim of the work is to estimate the position of sound sources. The proposed method uses a setup of two acoustic vector sensors (AVS). The intersection of azimuth rays from each AVS should indicate the position of a source. In practice, the result of position estimation using this method is an area rather than a point. This is a result of inaccuracy of the individual sensors, but more importantly, of the influence of a source...
-
Targed tracking with adaptive fusionof multiple sensor measurements.
PublicationW pracy przedstawiono metodę adaptacyjnej selekcji pomiarów z wielu radarów wykorzystywanych w procesie integracji pomiarów dla śledzenia obserwowanego obiektu. W przypadku dużego zróżnicowania dokładności pomiarów pochodzących z różnych radarów, rezultaty integracji pomiarów nie różnią się znacząco od wyników śledzenia opartego na pomiarach z najbardziej dokładnego źródła.
-
White-light interferometric temperature sensor for biomedical diagnostic.
PublicationW artykule opisano opracowany model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry-Perot wykorzystującego interferencję światła białego przeznaczonego do zastosowań biomedycznych. Analizowano czujnik wykonany ze światłowodu wielomodowego o skokowym profilu współczynnika załamania oraz ze światłowodu monomodowego. Zasadniczym celem był dobór parametrów mający na celu uzyskania maksymalnej widzialności...
-
Trajectories detection in a distributed multi-sensor tracking system
PublicationW pracy rozważono problem śledzenia obiektów poruszających się za pomocą rozproszonego systemu wieloczujnikowego. Głównym zadaniem systemu śledzenia jest detekcja i estymacja trajektorii obiektów poruszających się w obserwowanej przestrzeni. Trajektoria obiektu to ciąg estymat kinematycznego stanu obiektu, jego pozycji, prędkości, itp. Klasyczne systemy śledzenia oparte są na filtrze Kalmana korzystającym z danych z pojedynczego...
-
QUASI-DISTRIBUTED NETWORK OF LOW-COHERENCE FIBER-OPTIC FABRY-PÉROT SENSORS WITH CAVITY LENGTH-BASED ADDRESSING
PublicationDistributed measurement often relies on sensor networks. In this paper, we present the construction of low coherent fiber-optic Fabry-Pérot sensors connected into a quasi-distributed network. We discuss the mechanism of spectrum modulation in this type of sensor and the constraints of assembly of such sensors in the network. Particular attention was paid to separate the signals from individual sensors, which can be achieved by...
-
The Concept of Accuracy Analysis of the Vertical Displacements Gained from the Hydrostatic Levelling Systems’ Measurements
PublicationAbstract: Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the...
-
Use of Sensory Analysis Methods to Evaluate the Odor of Food and Outside Air
PublicationSensory analysis is applied in many areas of daily life. It is used to carry out the sensory evaluation of foodstuffs or other products and to evaluate the properties of odors present in the environment. The authors attempt to summarize the knowledge on the classification and application of sensory analysis methods to evaluate the odor nuisance of air, which allows the identification of sensory impressions and determination of...
-
Gender differences in body-esteem among seniors: Beauty and health considerations
Publication -
Cortical Activation Changes Associated with Autonomous Sensory Meridian Response (ASMR)
Publication -
Tensile strength of a weave tendon suture using tendons of different sizes
PublicationThis study compared the maximum load, stress, elongation at failure and the mode of failure of three kinds of tendons most frequently used for tendon grafting and tendon transfers, using the Pulvertaftweave suture.
-
Influence of the Addition of Selected Spices on Sensory Quality and Biological Activity of Honey
PublicationBee honey is nutritious and has numerous health benefits, but its taste is for many people too bland. Honey with addition of spices could be important to the food industry as a functional product with positive health image and interesting taste. Such product would definitely meet health-driven consumers’ expectations. Therefore, the aim of this study was to evaluate the effect of addition of selected spices on sensory, antimicrobial,...
-
GPU-Accelerated Finite-Element Matrix Generation for Lossless, Lossy, and Tensor Media [EM Programmer's Notebook]
PublicationThis paper presents an optimization approach for limiting memory requirements and enhancing the performance of GPU-accelerated finite-element matrix generation applied in the implementation of the higher-order finite-element method (FEM). It emphasizes the details of the implementation of the matrix-generation algorithm for the simulation of electromagnetic wave propagation in lossless, lossy, and tensor media. Moreover, the impact...
-
Differentiating patients with obstructive sleep apnea from healthy controls based on heart rate-blood pressure coupling quantified by entropy-based indices
PublicationWe introduce an entropy-based classification method for pairs of sequences (ECPS) for quantifying mutual dependencies in heart rate and beat-to-beat blood pressure recordings. The purpose of the method is to build a classifier for data in which each item consists of two intertwined data series taken for each subject. The method is based on ordinal patterns and uses entropy-like indices. Machine learning is used to select a subset...
-
On the effective properties of foams in the framework of the couple stress theory
PublicationIn the framework of the couple stress theory, we discuss the effective elastic properties of a metal open-cell foam. In this theory, we have the couple stress tensor, but the microrotations are fully described by displacements. To this end, we performed calculations for a representative volume element which give the matrices of elastic moduli relating stress and stress tensors with strain and microcurvature tensors.
-
Highly sensitive microwave sensors based on open complementary square split-ring resonator for sensing liquid materials
PublicationThis paper presents high-sensitivity sensors based on open complementary square split-ring resonator and modified open complementary split-ring resonator operating at 4.5 GHz and 3.4 GHz, respectively. The sensors are designed for the detection of multiple liquid materials, including distilled water, methanol, and ethanol. The liquid under test is filled in a glass container loaded using a pipette. Compared to the conventional...
-
Field Calibration of Low-Cost Particulate Matter Sensors Using Artificial Neural Networks and Affine Response Correction
PublicationDue to detrimental effects of atmospheric particulate matter (PM), its accurate monitoring is of paramount importance, especially in densely populated urban areas. However, precise measurement of PM levels requires expensive and sophisticated equipment. Although low-cost alternatives are gaining popularity, their reliability is questionable, attributed to sensitivity to environmental conditions, inherent instability, and manufacturing...
-
Reduced graphene oxide doping with nanometer-sized ferrocene moieties – New active material for glucose redox sensors
Publication -
Radar water level sensors for full implementation of the river information services of border and lower section of the Oder in Poland
Publication -
High Dynamic Range Microwave Displacement and Rotation Sensors Based on the Phase of Transmission in Groove Gap Waveguide Technology
PublicationThis research is focused on the design and realization of displacement sensors in gap waveguide technology. It is shown that with a small but fundamental change in the structure of a conventional gap waveguide, a linear displacement can be sensed. To this end, a unique feature of gap waveguides, i.e. the fact that no electrical connection between the top and bottom parts of the gap waveguide is required, is used. It is further shown...
-
Exhaled breath gas sensing using pristine and functionalized WO3 nanowire sensors enhanced by UV-light irradiation
PublicationThe development of advanced metal-oxide-semiconductor sensing technologies for the detection of Volatile Organic Compounds (VOCs) present in exhaled breath is of great importance for non-invasive, cheap and fast medical diagnostics. Our experimental studies investigate the effects of operating temperature selection and UV-light irradiation on improving the response of WO3 nanowire sensors towards exhaled breath exposure. Herein,...
-
Fluctuation enhanced gas sensing with WO3-based nanoparticle gas sensors modulated by UV light at selected wavelengths
PublicationThe sensitivity and selectivity of WO3-based gas sensors can be enhanced by UV-irradiation-induced modulation, especially if different wavelengths are employed. We used fluctuation-enhanced gas sensing, based on measurements of resistance fluctuations in the gas sensor, to study the effects of such modulation on the noise intensity for ambient atmospheres of synthetic air without and with additions of small amounts of ethanol,...
-
Application of sol-gel-developed integrated optic devices to biochemical fiber optic sensors based on polarimetric interferometry.
PublicationW pracy omówiono zasady działania sensorów optycznych wykonanych w technologii optyki zintegrowanej i wykorzystujących interferometrię polaryzacyjną. Zaproponowano konstrukcję jednorazowego przetwornika pomiarowego, wykonanego w technologii sol-żel z materiałów hybrydowych, która umożliwia wykorzystanie nieodwracalnych reakcji chemicznych do pomiarów w medycynie, chemii i ochronie środowiska. Omówiono technologię syntezy materiałów...
-
On the possibility of using liguid or lipid, lipid like-polimer membrane systems as taste sensor
PublicationZastosowano membrany ciekłe w oscylatorach zawierających oleinian sodu i substancje należące do czterech klas smaku. Wpływają one na charakterystyki oscylacyjne potencjału elektrycznego miedzy fazami wodnymi. Otrzymane atraktory są różne w kształcie i dwu wymiarowej powierzchni. Powierzchnia ta zależy także od stężenia sacharozy w układzie. Mogą one byc użyte jako ''odcisk palca'' do indentyfikacji odpowiednije substancji smakowej....
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublicationPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Sandwich Biobattery with Enzymatic Cathode and Zinc Anode Integrated with Sensor
PublicationCarbon paper covered with side-naphthylated multi walled carbon nanotubes was used as the conducting support for the construction of a biocathode in a hybrid biofuel cell. Laccase Carrena unicolor enzyme was employed as the catalyst for the 4e reduction of oxygen and a zinc disc covered with hopeite was used as the anode. Derivatized carbon nanotubes increase the working surface of the electrode and provide direct contact with...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
The SARS‐CoV ‐2 specific IgG antibodies biophotonic sensor
PublicationIn this paper, we present the design and the principle of operation of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific immunoglobulin G (IgG) biophotonic sensor, which is based on the single-mode telecommunication fiber. We fabricated the sensor head at the face of the single mode fiber-28. Due to the process of bio-functionalization, our sensor has the ability to selectively detect the SARS-CoV-2 specific...
-
Eventual Convergence of the Reputation-Based Algorithm in IoT Sensor Networks
PublicationUncertainty in dense heterogeneous IoT sensor networks can be decreased by applying reputation-inspired algorithms, such as the EWMA (Exponentially Weighted Moving Average) algorithm, which is widely used in social networks. Despite its popularity, the eventual convergence of this algorithm for the purpose of IoT networks has not been widely studied, and results of simulations are often taken in lieu of the more rigorous proof....
-
Design Optimization of an Anisotropic Magnetoresistance Sensor for Detection of Magnetic Nanoparticles
Publication -
Power quality conditioners with minimum number of current sensor requirement
Publication -
Localization in wireless sensor networks using switched parasitic antennas
PublicationA switched parasitic monopole antenna for 2.4 GHz ISM applications is design and investigated in this paper. One of the most promising applications for such switched-beam antennas is localization in wireless sensor networks (WSN). It is demonstrated that the use of this antenna improves accuracy of localization algorithms and allows for reduction of the number of reference nodes in localization system.
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationWykrywanie zapachów podczas aromaterapii może być przeprowadzone za pomocą pojedynczego sensora gazów. W pracy rozważono efektywność detekcji zapachów olejków eterycznych za pomocą rezystancji DC oraz zjawisk fluktuacyjnych w tych sensorach, typu TGS2600,TGS2602,TGS823. Badania koncentrowały się na praktycznym zastosowaniu w aromaterapii do określania intensywności emitowanego zapachu. Opisano szczegółowo system do emisji zapachów.
-
Evaluation of physiological and physical activity by means of a wireless multi-sensor
Publicationmonitorowanie osób starszych, upośledzonych ruchowo i/lub rekonwalescentów w warunkach domowych jest dynamicznie rozwijającą się dyscypliną nauki i techniki. szczególnego znaczenia nabierają systemy przeznaczone dla osób starszych żyjących samotnie. w pracy przedstawiono zintegrowany system umożliwiający monitorowanie wybranych parametrów fizjologicznych (ekg, ikg, resp) oraz aktywności fizycznej za pomocą akcelerometru. działanie...
-
Influence of aprotic solvent on selectivity of an amperometric sensor with nafion membrane
PublicationW publikacji przedstawiono rezultaty badań dotyczące selektywności amperometrycznego czujnika ditlenku siarki z membraną nafionową wobec tlenku węgla i dwutlenku azotu jako interferentów. Zostały porównane współczynniki selektywności dla czujników wypełnionych roztworami elektrolitów zawierających wodne roztwory kwasu siarkowego i różne ilości rozpuszczalnika aprotycznego - dimetylosulfotlenku.
-
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublicationSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
Influence of aprotic solvent on a signal of an amperometric sensor with Nafion membrane
PublicationW pracy przedstawiono wyniki badań charakterystyk analitycznych amperometrycznego czujnika ditlenku siarki wyposażonego w mebranę nafionową i wypełnionego roztworami elektrolitów o różnej zawartości dimetylosulfotlenku. Ocenie poddany został wpływ zawartości DMSO w roztworze elektrolitu wewnętrznego czujnika oraz prędkości przepływu gazu na czułość czujnika i czas odpowiedzi na zmiany stężenia ditlenku siarki.
-
The influence of electrocatalytic toxic gas sensor construction on its performance
PublicationW pracy przedstawiono porównanie właściwości elektrokatalitycznych czujników gazów przygotowanych na bazie różnych elektrolitów stałych oraz wykonanych w różnych technologiach.
-
Electrical properties of poros nanocrystalline undoped ceria oxygen sensor
PublicationW pracy zaprezentowano wykonanie czujnika z niedomieszkowanego tlenku ceru o nanometrowych ziarnach krystalicznych. Zastosowana metoda nanoszenia warstw zalicza się do metod niskotemperaturowych. Wytworzone warstwy przebadano za pomocą dyfrakcji rentgenowskiej, mikroskopii elektronowej oraz spektroskopii impedancyjnej. Wykonane czujniki charakteryzują się szybkim czasem odpowiedzi i stabilnym zachowaniem przy zmianach ciśnienia...