Filters
total: 5223
-
Catalog
- Publications 4035 available results
- Journals 8 available results
- Conferences 7 available results
- Publishing Houses 1 available results
- People 63 available results
- Projects 4 available results
- e-Learning Courses 411 available results
- Events 1 available results
- Open Research Data 693 available results
displaying 1000 best results Help
Search results for: CALIBRATION OF SPME
-
Simplified AutoDock force field for hydrated binding sites
Publicationhas been extracted from the Protein Data Bank and used to test and recalibrate AutoDock force field. Since for some binding sites water molecules are crucial for bridging the receptor-ligand interactions, they have to be included in the analysis. To simplify the process of incorporating water molecules into the binding sites and make it less ambiguous, new simple water model was created. After recalibration of the force field on...
-
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublicationA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Application of gas chromatography to the analysis of spirit-based alcoholic beverages
PublicationSpirit-based beverages are alcoholic drinks, which production processes are dependent on the type and origin of raw materials. The composition of this complex matrix is difficult to analyze and scientists commonly choose a gas chromatography techniques for this reason. With a wide selection of extraction methods and detectors it is possible to provide qualitative and quantitative analysis for many chemical compounds with a various...
-
Co-simulation strategy of transient CFD and heat transfer in building thermal envelope based on calibrated heat transfer coefficients
PublicationThe paper presents a strategy to develop a fully transient numerical model of a heat transfer in building, using a transient CFD model of indoor air and a thermal envelope model, running in a co-simulation. The strategy relies on the utilization of RANS with a high-Re turbulence model and a wall function, which enables to use a coarse computational mesh limiting the computational time. Since wall functions give invalid heat transfer...
-
Obyś cudze dzieci uczył! Magia zawodu czy przekleństwo wszech czasów? Na wstępie od redaktorki – bardzo osobiście [Teaching as such. A glamorous profession or a curse of all time? Some introductory remarks from the editor]
Publication -
Pressure drop of HFE7000 and HFE7100 during flow condensation in minichannels
PublicationAttention is focused on the issues of flow resistance and pressure drop of perspective refrigeration fluids during condensation in the two-phase flow in minichannels. The case of the flow through a cylindrical single channel of 2.3 mm inner diameter was carefully analyzed. Pressure drop tests have been performed in diabatic flow conditions. The effect of heat flux, mass flux, vapour quality and saturation temperature on the two-phase...
-
Krzysztof Jan Kaliński prof. dr hab. inż.
PeopleKrzysztof J. Kaliński completed his MSc study at Gdańsk University of Technology (GUT) Faculty of Production Engineering (1980, result – get a first). He obtained PhD at GUT Faculty of Machine Building (1988, result – get a first), DSc at GUT Faculty of Mechanical Engineering (ME) (2002, result – get a first), and professor’s title – w 2013 r. In 2015 r. he became full professor.His research area includes: theoretical and applied...
-
Modern solutions in the field of microextraction using liquid as a medium of extraction
PublicationThe monitoring of compounds present in samples at trace/ultra-trace level usually requires a preliminary step of isolation and/or enrichment of analytes. Against, sample preparation is considered as crucial part of whole analytical procedures, in particular in samples characterized by complex matrices composition. Several new miniaturized extraction techniques is introduced and extensively applied to different type of samples....
-
Jakub Konkol dr inż.
People -
An new method of audio-visual correlation analysis
PublicationThis paper presents a new methodology of conducting the audio-visual correlation analysis employing the gaze tracking system. Interaction between two perceptual modalities, seeing and hearing, their interaction and mutual reinforcement in a complex relationship was a subject of many research studies. Earlier stage of the carried out experiments at the Multimedia Systems Department (MSD) showed that there exists a relationship between...
-
Model-based identification of the dominant N2O emission pathway in a full-scale activated sludge system
PublicationActivated sludge models (ASMs), extended with an N2O emission module, are powerful tools to describe the operation of full-scale wastewater treatment plants (WWTPs). Specifically, such models can investigate the most contributive N2O production pathways and guide towards N2O and carbon footprint (CF) mitigation measures. A common practice is to develop and validate models using data from a single WWTP. In this study, a successfully...
-
Urządzenie do wytwarzania gazowych mieszanin wzorcowych z wykorzystaniem procesu barbotażu oraz permeacji
PublicationReference gas mixtures are classified to reference materials and are mainly used for quality monitoring and identification of impurities in atmospheric air. They can be also used for calibration of measuring devices. Nowadays, there is a need to develop a new techniques for the preparation of reference gas mixtures [1, 2]. In this paper the design and the operating principles of instrument based on the use of barbotage and permeation...
-
Thanos Of Titan
People -
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 4-8h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 4-8h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #24 - #25.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #24 (upper, rotating), #25 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #28 - #29.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #28 (upper, rotating), #29 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #30 - #31.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #30 (upper, rotating), #31 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #20 - #21.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #20 (upper, rotating), #21 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #22 - #23.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #22 (upper, rotating), #23 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #28 - #29.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #28 (upper, rotating), #29 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #26 - #27.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #26 (upper, rotating), #27 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Reverberation chamber in emc tests of naval systems
PublicationPaper covers the techniques of emission and immunity testing to the electromagnetic field in reverberation chamber. The procedure of he chamber calibration and field homogeneity assessment were covered. The naval forces' product as selected as an example for discussing the testing procedure in the chamber. The paper's summary gives the assortment of methodology in radiation emission testing and immunity to the electromagnetic field...
-
New achievements in the field of extraction of trace analytes from samples characterized by complex composition of the matrix
PublicationWithout any doubt, the monitoring of compounds present in samples at trace or ultra-trace level usually requires a preliminary step of isolation and/or enrichment of analytes due to the fact that majority of analytical techniques are not sensitive enough for direct determination of trace compounds. On the other hand, sample preparation is considered as crucial part of whole analytical procedures, in particular in samples characterized...
-
Deep eutectic solvents in analytical sample preconcentration Part B: Solid-phase (micro)extraction
PublicationOne of the key challenges of modern analytical chemistry is the monitoring of trace amounts of contaminants using sensitive and selective instrumental techniques. Due to the variety and complexity of some samples, it is often necessary to properly prepare a sample and to perform a preconcentration of trace amounts of analytes. In line with the principles of Green Analytical Chemistry (GAC), it is important for an analytical procedure...
-
Jerzy Pluciński dr hab. inż.
People -
Synchro-photogrammetry in the measurement of objects in motion - the case study
PublicationSynchronous photographs and digital photogrammetry methods in a measurement of objects in motion - the experiment. In the following paper, a case study example of a photogrammetric method based on synchronous digital photographs has been presented. This measurement method is an effective solution for tracking of moving objects, dynamic studies and dimensioning of geometry movements. Nowadays, the use of synchronous photography...
-
Estimation of object size in the calibrated camera image = Estymacja rozmiaru obiektów w obrazach ze skalibrowanej kamery
PublicationIn the paper, a method of estimation of the physical sizes of the objects tracked by the camera is presented. First, the camera is calibrated, then the proposed algorithm is used to estimate the real width and height of the tracked moving objects. The results of size estimation are then used for classification of the moving objects. Two methods of camera calibration are compared, test results are presented and discussed. The proposed...
-
Ocena wpływu dawki DME na wybrane wskaźniki procesu spalania w dwupaliwowym silniku o zapłonie samoczynnym
PublicationPrzedmiotem rozprawy jest analiza wpływu różnej ilości odparowanego DME wprowadzonego do kolektora dolotowego na wybrane wskaźniki spalania DME/ON dla wielu punktów pracy, turbodoładowanego silnika o zapłonie samoczynnym. Jako punkty pracy silnika, wybrano punkty najbardziej reprezentujące cykl jazdy WLTP dla samochodu Volkswagen Golf IV. Analizę procesu współspalania przeprowadzono z wykorzystaniem danych pomiarowych, uzyskanych...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h. High frequency burst recording.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. High frequency burst recording.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21,...
-
Physicochemical and photocatalytic data of Nb-doped faceted TiO2
Open Research DataRaw numerical data, obtained from the physicochemical measurements (XRD, DR-UV/Vis, EPR) and numerical data on photocatalytic activity (phenol degradation and 4-nitrophenol reduction) extracted from the HPLC-DAD results, obtained for the TiO2 nanoparticles that expose majority of the {0 0 1}, {1 0 0} or {1 0 1} facets and were doped with the nominal...
-
Elemental composition of deposited sediments - Warszawska/Havla tram-route junction (2024 May)
Open Research DataThis data set contains the elemental composition results of deposited sediments collected at the tram-route junction in Gdańsk. Samples collected after fifteen months of operation of tram line.
-
Progress in development of molecularly imprinted polymers as sorbents for sample preparation
PublicationSample preparation has been one of the most often investigated steps in analytical procedures.These investigations are focused on problems such as isolation of analytes from the sample matrix, matrix implification, analyte enrichment to the level above the detection limit of the instrumentation used, and the removal of interfering species to improve the final determination. Techniques based on solid (adsorption) and pseudo liquid...
-
Sample preparation methods used in food flavor analysis
PublicationJako, że żywność to skomplikowana matryca, a związki lotne w niej zawarte występują zazwyczaj na poziomie śladowym wymagane jest zastosowanie specjalnej procedury przygotowania próbek. W pracy zostały opisane niektóre metody przygotowywania próbek żywności, które łączą w sobie izolację i wzbogacanie analitów. Wśród opisanych metod znalazły się: PT, SPME, SDME, SBSE oraz SFE.
-
Robust Object Detection with Multi-input Multi-output Faster R-CNN
PublicationRecent years have seen impressive progress in visual recognition on many benchmarks, however, generalization to the out-of-distribution setting remains a significant challenge. A state-of-the-art method for robust visual recognition is model ensembling. However, recently it was shown that similarly competitive results could be achieved with a much smaller cost, by using multi-input multi-output architecture (MIMO). In this work,...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublicationNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Robust Object Detection with Multi-input Multi-output Faster R-CNN
PublicationRecent years have seen impressive progress in visual recognition on many benchmarks, however, generalization to the out-of-distribution setting remains a significant challenge. A state-of-the-art method for robust visual recognition is model ensembling. However, recently it was shown that similarly competitive results could be achieved with a much smaller cost, by using multi-input multi-output architecture (MIMO). In this work,...
-
Comments on various extensions of the Riemann–Liouville fractional derivatives : About the Leibniz and chain rule properties
PublicationStarting from the Riemann–Liouville derivative, many authors have built their own notion of fractional derivative in order to avoid some classical difficulties like a non zero derivative for a constant function or a rather complicated analogue of the Leibniz relation. Discussing in full generality the existence of such operator over continuous functions, we derive some obstruction Lemma which can be used to prove the triviality...
-
Analysis of the Impact of Galileo Observations on the Tropospheric Delays Estimation
PublicationIn this study we present analysis of the impact of Galileo observations on the ZTD and tropospheric gradients estimation. The tropospheric parameters were obtained in various scenarios, which differ from each other only in used satellite systems: Galileo-only, GPS-only, GPS/Galileo, GPS/GLONASS and GPS/GLONASS/Galileo. Then, comparative analysis between Galileo-only solution and the other ones, was carried out. As a reference,...
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublicationThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Investigation of the impact of ITRF2014/IGS14 on the positions of the reference stations in Europe
PublicationIn January 2017, the new realization of the International Terrestrial Reference Frame (ITRF) – ITRF2014, was released. Besides the higher accuracy and consistency of the new frame, an entirely new element – the post seismic deformation - was included. Moreover, the definition of the fundamental points has also been changed. All changes related to the new reference frame haveconsequences in the precise positioning using GNSS observations....
-
Maciej Jerzy Głowacki
PeopleMaciej Jerzy Głowacki is an alumnus of the Gdańsk University of Technology. He graduated with honors from the Faculty of Mechanical Engineering (B.Eng., 2017) and the Faculty of Electronics, Telecommunications and Informatics (M.S., 2018). Since 2014 he has been continuously actively involved in a research carried out at the Department of Metrology and Optoelectronics. His scientific activities include a deposition of antibacterial...
-
Sulfur compounds: Gas chromatography
PublicationSulfur compounds, due to their properties, are responsible for the damage of our environment. For this reason sulfur containing compounds are of constant concern in many fields. Gas chromatography (GC), due to combination of separation capability and sensitive detection is a prime technique for the analysis of thes compounds in various matrices. The chapter rewies general problems of the determination of these compounds by GC and...
-
Zastosowanie techniki ekstrakcji na fazie stałej (SPE) do zagęszczania wielopierścieniowych węglowodorów aromatycznych z płynów stosowanych w infuzji przy oznaczaniu tych związków techniką HPLC z detektorem fluorescencyjnym i diodowym
PublicationPraca zawiera metodykę przygotowania próbki oraz procedurę analityczną oznaczania obecności wielopierścieniowych węglowodorów aromatycznych (WWA) w płynach infuzyjnych stosowanych do wlewów dożylnych dla ludzi oraz wyniki badań stężeń tych węglowodorów w płynach stosowanych do infuzji oraz w stosowanych do produkcji płynów infuzyjnych - substancjach farmaceutycznych. W płynach do infuzji stwierdzono 0,2-7,6 ng/l Benzo(a)pirenu,...
-
Information Systems &Technologies /SPIE Conference on Digital Video Compression Algorithms & Techniques
Conferences -
Transfer learning in imagined speech EEG-based BCIs
PublicationThe Brain–Computer Interfaces (BCI) based on electroencephalograms (EEG) are systems which aim is to provide a communication channel to any person with a computer, initially it was proposed to aid people with disabilities, but actually wider applications have been proposed. These devices allow to send messages or to control devices using the brain signals. There are different neuro-paradigms which evoke brain signals of interest...
-
The shallow sea experiment with usage of linear hydrophone array
PublicationPurpose of this article is to present designed and made linear hydrophone array and the results obtained during in situ trails on Gulf of Gdańsk. The measuring system allowed to localize hydrophones in the selected points and perform measurements in both the horizontal antenna positioning and vertical. Made in this way recordings allow creating accurate 3D imaging of sound intensity/propagation. During research three floating objects...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublicationAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Microextraction Techniques Used in the Procedures for Determining Organomercury and Organotin Compounds in Environmental Samples
PublicationDue to human activities, the concentrations of organometallic compounds in all parts of the environment have increased in recent decades. The toxicity and some biochemical properties of mercury and tin present in the environment depend on the concentration and chemical form of these two elements. The ever-increasing demand for determining compounds at very low concentration levels in samples with complex matrices requires...
-
Eye tracking within near-to-eye display
PublicationIn this paper we investigate the effectiveness of the gaze interaction within near-to-eye display. The practical aspect of the paper is about combining an eye tracker with smart glasses. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of the implemented interaction methods is the one...