Search results for: CHEMICAL INSTALLATION TEMPERATURE CONTROL
-
Investigation of low-temperature cracking in newly constructed high-modulus asphalt concrete base course of a motorway pavement
PublicationThe paper presents the issue of low-temperature transverse cracks which have developed in newly constructed base courses made of high-modulus asphalt concrete mix (HMAC). Numerous transverse cracks developed in the analysed HMAC base during the winter season before the pavement was actually completed, both at the transverse joint locations and in the areas between them. This had not happened so far on such a scale during road construction...
-
DESIGN ANALYSIS OF HYBRID GAS TURBINE - FUEL CELL POWER PLANT IN STATIONARY AND MARINE APPLICATIONS
PublicationThe paper concerns design analysis of a hybrid gas turbine power plant with a fuel cell (stack). The aim of this work was to find the most favorable variant of the medium capacity (approximately 50 MW) hybrid system. In the article, computational analysis of two variants of such a system was carried out. The analysis let to calculate capacity, efficiency of both variants and other parameters like flu gas temperature. The paper...
-
Deep eutectic solvents – based green absorbents for effective volatile organochlorine compounds removal from biogas
PublicationVolatile organochlorine compounds (VOXs) presented in biogas can cause many technological and environmental problems. During the combustion of biogas containing VOXs, the corrosion of installation, as well as the formation of toxic by-products (polyhalogenated dioxins and furans) and further emission to the atmosphere, may occur. Therefore, in this study, a new procedure based on physical absorption was developed. In order to meet...
-
Consequences of suboptimal design of Building Integrated Photovoltaic Installation – a case study for Gdansk, Poland
PublicationThe carried out analysis concerns 2 kWp building integrated photovoltaic installation (BIPV) at the Chemistry Faculty of Gdansk University of Technology. It was proven that the generated energy data for every month diverge significantly from the expected vales. It is corelated with suboptimal orientation of the installation itself, as well as with the tilt angle varying from optimal.
-
The FEM analysis of pressure installation elements after simulated accidental overheating
PublicationThe paper presents innovative analysis focused on the safety aspects of existing pressure installation operation after overheating accidents. Results presented here can be applied in decision-making process concerning further operation of existing pressure installation after cooling system failure. In this paper the results of FEM analysis performed for a straight pipe and 90 degrees elbow, made of super duplex stainless steel,...
-
Investigation of tracking systems properties in CAVE-type virtual reality systems
PublicationIn recent years, many scientific and industrial centers in the world developed a virtual reality systems or laboratories. One of the most advanced solutions are Immersive 3D Visualization Lab (I3DVL), a CAVE-type (Cave Automatic Virtual Environment) laboratory. It contains two CAVE-type installations: six-screen installation arranged in a form of a cube, and four-screen installation, a simplified version of the previous one. The...
-
Static Shunt PE Voltage-Quality Controllers
PublicationThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
INFLUENCE OF TIME ON THE BEARING CAPACITY OF PRECAST PILES
PublicationOne of the most popular types of foundations in layered subsoil with very differentiated soil shear strengths are precast piles. One of the reasons is a fact that we can well control the driving process during the installation of these piles. The principles of the assessment of bearing capacity and settlements of the piles given by Eurocode 7, concentrate on two main methods, i.e. Static Pile Load Tests (SPLT) and Dynamic Driving...
-
Effects of full displacement pile installation on the stress and deformation state of surrounding soil: review
PublicationSeveral field and model tests have been conducted to investigate the impact of pile installation on bearing capacity. However, little is known about how piles behave during installation, how they interact with the surrounding soil, and how this affects sandy soil properties. This review paper investigates the effect of pile driving on surrounding sandy soil as it compacts sandy soil near to the pile. For this purpose, various related...
-
Effect of wet Hydrogen Sulfide on Carbon Steels Degradation in Refinery Based on Case Study
PublicationMaterial degradation caused by wet hydrogen sulfide (Wet H2S) is one of the major issues in refineries. Carbon steel is the main construction material used in refineries and is subjected not only to thickness loss but the hydrogen is the major concern. H2S leads to high atomic hydrogen penetration in steel which causes degradation in the form of blistering and/or cracking (HIC/SOHIC) and stress cracking in the area of welds and...
-
The use of recycled semiconductor material in crystalline silicon photovoltaic modules production - A life cycle assessment of environmental impacts
PublicationTo offset the negative impact of photovoltaic modules on the environment, it is necessary to introduce a longterm strategy that includes a complete lifecycle assessment of all system components from the production phase through installation and operation to disposal. Recycling of waste products and worn-out systems is an important element of this strategy. As the conclusions from the previous studies have shown, thermal treatment...
-
Decrease in Photovoltaic Module Efficiency Due to Deposition of Pollutants
PublicationThe deposition of pollutants on the surface of photovoltaic (PV) modules reduce the efficiency that can be achieved in given climatic conditions. This results in the loss of energy yield obtained from the solar installation. A number of factors determine the scale of this problem. The first of these is the amount of impurities deposited, the associated amount of precipitation, and the speed and direction of the wind. A second aspect...
-
LDFEM analysis of FDP auger installation in cohesive soil
PublicationThis paper deals with large deformation finite element (LDFE) preliminary modelling of Full Displacement Pile (FDP) installation in cohesive soil deposit located in Jazowa, Poland. The detailed FDP auger geometry is applied and the drilling process is modelled with full 3D Coupled Eulerian-Lagrangian (CEL) formulation. The total stress approach and elastic-perfectly plastic model with rate-dependent Mises plasticity is used. The...
-
PV installations and the safety of residential buildings
PublicationThe dynamic development of the photovoltaic industry entails threats that have a direct impact on the safety of residential buildings. Appropriate design of a PV installation can be a challenge due to the multifaceted nature of this issue. The designer should take into account issues related to the selection of electrical parameters of the installation, adapting lightning and surge protection in accordance...
-
The Influence of Loop Heat Pipe Evaporator Porous Structure Parameters and Charge on Its Effectiveness for Ethanol and Water as Working Fluids
PublicationAbstract: This paper presents the results of experiments carried out on a specially designed experimental rig designed for the study of capillary pressure generated in the Loop Heat Pipe (LHP) evaporator. The commercially available porous structure made of sintered stainless steel constitutes the wick. Three different geometries of the porous wicks were tested, featuring the pore radius of 1, 3 and 7 um. Ethanol and water as two...
-
Analysis of operations of combined STIG installation
PublicationSteam injection in gas turbines is interesting technology with good energetic and ecological properties of gas turbines. In these applications the heat of exhaust gases is used to produce steam, which is injected in the combustion chamber of a gas turbine. The steam injection increase the power and efficiency of the installation. there are some possibilities to increases the properties of STIG turbines, for example by meas of additional...
-
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublicationThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
Aspects of intergranular corrosion of AISI 321 stainless steel in high-carbon-containing environments
PublicationPurpose – The purpose of this paper is to present a case study of unexpected sensitization to intergranular corrosion of highly resistant AISI 321 steel in petrochemical conditions, where it was subjected to the simultaneous influence of elevated temperature of 250°C and vapors from the asphalt production process. Design/methodology/approach – Corrosion coupons were exposed in an installation carrying asphalt vapors. To identify...
-
Evaluation of Street Lighting Efficiency Using a Mobile Measurement System
PublicationThe issue concerns the initial stage of work on a method for performing a rapid assessment of the energy efficiency and illuminance of a street lighting installation. The proposed method is based on simultaneous measurement of illuminance from three lux meters placed on the roof of the vehicle. The data are acquired in road traffic, while the vehicle is driving. The proposed solution will allow in the future to quickly and reproducibly...
-
Numerical analysis of pile installation effects in cohesive soils
PublicationIn this thesis the empirical equation for radial effective stress calculation after displacement pile installation and following consolidation phase has been proposed. The equation is based on the numerical studies performed with Updated Lagrangian, Arbitrary Lagrangian-Eulerian and Coupled Eulerian-Lagrangian formulations as well as the calibration procedure with database containing world-wide 30 pile static loading tests in cohesive...
-
Incorporating installation effects into the probability analysis of controlled modulus columns
PublicationThis technical report presents the probabilistic analysis which integrates the Monte Carlo simulation (MCS) with random field theory to model the load–displacement behavior of Controlled Modulus Columns (CMCs) in overconsolidated Poznań clay. Presented study focuses on the practical aspects of statistical analysis of geotechnical data, numerical model development, and results evaluation. Variability and spatial distribution of...
-
Internet system for supply and temperature control in server rooms
Publication.
-
Concept of the mobile monitoring system for chemical agents control in the air
PublicationW artykule przedstawiono koncepcję mobilnego systemu monitoringu związków chemicznych zanieczyszczających powietrze. Nowością w przedstawionej koncepcji monitoringu jest pomiar zanieczyszczeń powietrza wzdłuż ciągów komunikacyjnych, co do tej pory nie jest realizowane. W tym celu przedstawiono propozycję rozwiązania stosunkowo małego, bezobsługowego modułu do pomiarów związków chemicznych, który z łatwością będzie montowany na...
-
Influence of Installation Effects on Pile Bearing Capacity in Cohesive Soils – Large Deformation Analysis Via Finite Element Method
PublicationIn this paper, the whole process of pile construction and performance during loading is modelled via large deformation finite element methods such as Coupled Eulerian Lagrangian (CEL) and Updated Lagrangian (UL). Numerical study consists of installation process, consolidation phase and following pile static load test (SLT). The Poznań site is chosen as the reference location for the numerical analysis, where series of pile SLTs...
-
Image projection in Immersive 3D Visualization Laboratory
PublicationIn recent years, many centers in the world attempted to build a virtual reality laboratory. The main idea of such laboratory is to allow the user to “immerse” into and move in a computer-generated virtual world. In the paper, the underlying principles of the system of virtual reality (VR) are described. The selected implementations constructed by the research centers of the world are also presented. The cave automatic virtual environment...
-
Redifining the Space – The Impact of Art Instalation in the Public Space
PublicationThe article presents the outcomes of the ‘Art and design’ - interdisciplinary programme WIRE 2013, and the work of studio regarding the impact of art instalation in the public Space . The subject of the workshop was an ‘Architectural Installation’. The relationship between art and architecture remains a challenging issue today, first and foremost in the domain of architecture, and particularly in art and design schools. To address...
-
The advanced monitoring as a key factor for appropriate optimization and control of full-scale activated sludge systems – case study Debogorze WWTP.
PublicationComputer simulation has become a helpful tool in wastewater treatment systems performance and effectiveness analysis. Advanced monitoring, by using appropriate software, enables to create a mathematical model of a real wastewater treatment plant (WWTP), run a simulation and subsequently interpret results under various conditions. An operation of WWTP is usually controlled by global parameters such as flow, solids retention time,...
-
The Influence of a Photovoltaic Micro-Installation on the Low-Frequency Parameters of Electricity at PCC and Its Impact on the Thermal Characteristics of Selected Devices
PublicationThis manuscript illustrates the measurement results of parameters describing the quality of energy at the PCC (point of common coupling) of a photovoltaic micro-installation that can significantly affect devices in the same power grid. The analyses reflecting heating of selected devices used in domestic installations, which were performed in an isolated laboratory environment, are also indicated. The conducted study aimed at checking...
-
Quality Assurance and Quality Control in the Analytical Chemical Laboratory: A Practical Approach.
PublicationNowe opracowanie książkowe z zakresu QA/QC to praktyczny podręcznik zarówno dla studentów jak i pracowników laboratoriów. Opisano systemu jakości wyników pomiarów analitycznych i poszczególnych jego składników: spójności pomiarowej, niepewności pomiaru, walidacji procedury analitycznej, materiałów odniesienia i badań międzylaboratoryjnych. Opisano i przedstawiono narzędzia statystyczne służące do obliczania parametrów walidacyjnych,...
-
Control of mass concentration of reagents by sound in a gas with nonequilibrium chemical reactions
PublicationThe weakly nonlinear dynamics of a chemically reacting gas is studied. Nonlinear interaction of acoustic and nonacoustic types of motion are considered. We decompose the base equations using the relationships of the gas-dynamic perturbations specific for every type of motion. The governing equation for the mass fraction of a reagent influenced by dominating sound is derived and discussed. The conclusions concern the equilibrium...
-
Results from tests on bolted connection components for evaluation of friction coefficient in various contact conditions
PublicationThe main purpose of the work was the analysis and evaluation of the self-locking quality of a bolted joint covered with Xylan 1070 coating, with comparison to the classic bolts lubricated with Molykote compound during assembly. The second part of the work was the verification of the compliance of the bolts and nuts used in the installation with the ASME B1.1 norm.
-
Oversizing the photovoltaic generator capacity in a micro photovoltaic plant
PublicationA significant part of photovoltaic micro installations in Poland is characterized by photovoltaic generator oversizing in relation to the inverter. The idea of oversizing, however, still raises doubts among some plant owners. In the paper, the energy yield of installation with an oversized and not oversized photovoltaic generator is presented on selected examples, showing the legitimacy of oversizing.
-
Processing of Satellite Data in the Cloud
PublicationThe dynamic development of digital technologies, especially those dedicated to devices generating large data streams, such as all kinds of measurement equipment (temperature and humidity sensors, cameras, radio-telescopes and satellites – Internet of Things) enables more in-depth analysis of the surrounding reality, including better understanding of various natural phenomenon, starting from atomic level reactions, through macroscopic...
-
Combined operation of 900MW power plant with the ORC through the bleed steam extraction point and CO2 recovery system
PublicationThe work presented here is aimed at utylisation of waste heat in the reference supercritical power plant in the manner to produce electricity in ORC installation. The waste heat is available in the form of a stream of hot water at 90 C, recovered from the exhaust gases in the amount of 200MW. Such low enthalpy heat source is rather insufficient to produce a good quality vapour to feed the ORC turbine. Therefore an original approach...
-
The analysis of soil resistance during screw displacement pile installation
PublicationThe analysis of soil resistances during screw displacement pile installation based on model and field tests. The investigations were carried out as a part of research project, financed by the Polish Ministry of Science and Higher Education. A proposal of empirical method for prediction of rotation resistance (torque) during screw auger penetration in non-cohesive subsoil based on CPT result.
-
New concept of drilling auger for displacement pile installation
PublicationIn 2020, a new version of the screw displacement auger for pile installation in soil was developed and patented in Poland. It was named DPDT (Displacement Pile Drilling Tool). The general aim of its development was to reduce the soil resistances to the auger during screwing into the ground while maintaning a good load-bearing capacity for the screw displacement piles. The “DPDT-Auger” prototype was tested as a scaled-down model...
-
Systemy Smart Cities - studium przypadku
PublicationThe paper presents the architecture of an enterprise service bus used in the construction of information systems processing large amounts of data for decision-making needs at the City Hall in Gdańsk. The key concept of processes of bus development involves installation of developing environment, database connection, flow mechanisms and data presentation. The issue was supported by models such as KPI (Key Processes Identifier) and...
-
TEMPERATURE AND RELATIVE HUMIDITY CONTROL IN MASS AND DECAY PREVENTION IN POSTHARVEST HANDLING OF PEACHES
Publication -
Decision Support System to Improve the Effectiveness of Chemical Control Against Cutworms in Sugar Beet
Publication -
Quality Assurance and Quality Control in the Analytical Chemical Laboratory. A practical approach : Second edition
PublicationThe second edition defines the tools used in QA/QC, especially the application of statistical tools during analytical data treatment. Clearly written and logically organized, it takes a generic approach applicable to any field of analysis. The authors begin with the theory behind quality control systems, then detail validation parameter measurements, the use of statistical tests, counting the margin of error, uncertainty estimation,...
-
General concept of functional safety - standarisation and sector aspects
PublicationRozdział poświęcono koncepcji bezpieczeństwa funkcjonalnego. Bezpieczeństwo funkcjonalne jest częścią bezpieczeństwa całkowitego zależną od odpowiedniej odpowiedzi systemów sterowania i/lub zabezpieczeń na sygnały wejściowe podczas wystąpienia stanów nienormalnych maszyny, instalacji lub obiektu podwyższonego ryzyka. Koncepcja bezpieczeństwa funkcjonalnego przedstawiona w normie IEC 51508 stanowi przykład dobrej praktyki inżynierskiej...
-
Koncepcja zdalnego sterowania i monitoringu urządzeń trakcyjnych z wykorzystaniem technologii teleinformatycznych
PublicationAdvancement in wireless communication enables engineers to apply sophisticated and relatively inexpensive technologies in new fields of industry, which were previously designated solely to wire-based solutions. One of those fields is railway transportation system. In effect of a high reliability and safety demands, this area was resistive to new technologies. Nowadays, increased security and reliability of wireless sensor networks...
-
Application of Eco-innovative Technologies of Nutrients Removal in Wastewater – Case Study BARITECH Project
PublicationEco-innovative technologies in wastewater treatment should provide not only stringent standards for the quality of treated wastewater but also ensure maximum recovery of energy and raw materials from wastewater. One of the ways to improve the removal efficiency of nitrogen and phosphorus compounds in existing conventional wastewater treatment plants is pretreatment of reject water generated during the mechanical...
-
Non-Visual Aspects of the Space Performing the Soundscape of the City
PublicationThe relationship between art and architecture remains a challenging issue today, first and foremost in the domain of architecture, and particularly in art and design schools. To address this issue, the Winter School International Research and Education (WIRE) programme was run in the Gazi University Department of Architecture between 2013 and 2014, with the main theme being “Art and Architecture”, and the sub-themes determined...
-
Modeling of luminance distribution in CAVE-type virtual reality systems
PublicationAt present, one of the most advanced virtual reality systems are CAVE-type (Cave Automatic Virtual Environment) installations. Such systems are usually consisted of four, five or six projection screens and in case of six screens arranged in form of a cube. Providing the user with a high level of immersion feeling in such systems is largely dependent of optical properties of the system. The modeling of physical phenomena plays nowadays...
-
Soiling Effect Mitigation Obtained by Applying Transparent Thin-Films on Solar Panels: Comparison of Different Types of Coatings
PublicationDust accumulation on the front cover of solar panels is closely linked to location and orientation of photovoltaic (PV) installation. Its build-up depends on the module tilt angle, frequency of precipitation, humidity, wind strength and velocity, as well as grain size. Additionally, soil composition is determined by solar farm surroundings such as local factories, agricultural crops, and traffic. Over time, molecules of atmospheric...
-
Numerical simulation of screw displacement pile interaction with non-cohesive soil
PublicationA trial numerical simulation of screw displacement pile interaction with non-cohesive subsoil during the transfer of compression load. The simulation was carried out in an axisymmetric system. The technological phases of pile installation in the ground were numerically modelled using equivalent processes which provided similar effects to real technical actions. The results of the numerical calculations were verified by comparing...
-
Modeling of the internal combustion engine cooling system
PublicationThe article concerns computer modelling of processes in cooling systems of internal combustion engines. Modelling objectives and existing commercial programs are presented. It also describes Author’s own method of binding graphs used to describe phenomena in the cooling system of a spark ignition engine. The own model has been verified by tests on the engine dynamometer. An example of using a commercial program for experimental...
-
Super capacitor energy bank MEDCOM UCER-01 in Gdynia trolleybus system
PublicationSince 2001, trolleybus system in Gdynia has been involved in many activities related to the reduction of power consumption, both in terms of implementation and research and development. The installation of the supercapacity energy bank on substation Wielkopolska in 2014 year was one of them. It is the first such big stationary supercapacitor storage system installed in trolleybus supply system in the Middle - Eastern Europe. The...
-
Load-settlement characteristics of piles working in a group
PublicationLoad-settlement characteristic (Q-s) of an axially loaded pile can be empirically determined from a static pile load test or on the basis of calculations using, e.g. transfer functions or numerical methods (FEM). The transfer functions method usually rely on empirical data, i.e. the function parameters are determined on the basis of numerous pile test results. Thus this method takes into account pile installation technology and...